Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA05242Slide · faultyEMERGENCY LIGHT AT DOOR 1L IS INOP. INTERNAL ELECTRICAL FAULT (SLIDE 1L). REPLACED DOOR SLIDE 1L, OPS CHECKED NORMAL.SDR SWAA076450Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF DOOR WHEN OPENED. SLIDE DID NOT DEPLOY. REMOVED AND REPLACED SLIDE PER MM.SDR 2007UALA05246Slide · low pressureDOOR 4L SLIDE PRESSURE IS ON LOW END OF GREEN BAND. REPLACED SLIDE ASSY.
SDR 2007UALA05221Slide · brokenNR 1 LT DOOR SLIDE BROKEN. REPLACED SLIDE ASSY.SDR 2008FA0000005Cable · wrong partINCORRECT PULL HANDLE CABLE (FIRING CABLE) DEPLOYMENT CABLE WAS SECURED WITH TAPE WHICH HINDERED DEPLOYMENT OF SLIDE. INCORRECT HANDLE AND CABLE ASSEMBLY FITTED. CABLE NOT THREADED TROUGH GROMMET DUE TO INCORRECT FIRING CABLE ASSEMBLY. CMM 25-61-10, STEPS 2SDR SWAA076386Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SA07084Cable · brokenDCA - THE LEFT HAND, OVERWING SLIDE CYLINDER ASSEMBLY HAS A BROKEN CABLE END. MAINTENANCE REPLACED THE LEFT HAND, OVERWING SLIDE CYLINDER ASSEMBLY. OK FOR SERVICE.SDR 2007UALA05185Slide · faultyRIGHT OVERWING SLIDE AFT AREA, ARM CAM OF SLIDE HITTING STOP BLOCK FITTING.SDR 2007UALA05184Slide · faultyLEFT OVERWING SLIDE AFT AREA, ARM CAM OF SLIDE HITTING STOP BLOCK FITTING.SDR 2007UALA05183Cylinder · defectiveRIGHT OVERWING ESCAPE SLIDE CYLINDER DEPLOYMENT CABLE BALL IS BELOW SPRING FORCE RETAINER.SDR SWAA076375Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA076373Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076366Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076359Slide · frayedDURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE GIRT SKIRT FRAYED. REMOVED AND REPLACED VAC SLIDE PER MM.SDR SWAA076345Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA076344Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076335Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076380Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR UPS07151310Warning Light · inoperativeSLIDE ARMED WARNING LIGHT ON ENTRY DOOR DOES NOT ILLUMINATE WHEN TESTED. DEFERRED LIGHT ASSY PER MEL 52-73-01-1. OK TO CONTINUE. REF AMM A300 52-10-11-05 ADJ/TEST RECONNECTED FWD ENTRY DOOR SLIDE ARM CONTROL BOX. OPS CHKS OF FWD ENTRY DOOR ARM CONTROL NORMALSDR SWAA076299Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA076291Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076328Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA076247Hook · looseR1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. SECURED HOOK PER MM.SDR 2007UALA05097Lanyard · out of positionDOOR 1R UNABLE TO ARM SLIDE. FOUND GIRT BAR LANYARD INTERFERENCE. REPOSITIONED GIRT BAR LANYARD. DOOR FUNCTIONS NORMALLY.SDR SA07083Lanyard · misroutedPIT - THE RIGHT HAND, FORWARD AND LEFT HAND AFT DOOR SLIDES HAVE IMPROPERLY ROUTED LANYARDS. MAINTENANCE ROUTED THE LANYARDS PROPERLY. OK FOR SERVICE.SDR SWAA076239Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076236Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076199Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR F3LA200700406Release Cable · inoperativeDURING C4/S1 CHECK, INSPECTION REPORTED RT OVERWING EXIT SLIDE RELEASE CABLE WOULD NOT RETRACT. REMOVED AND REPLACED RT OVERWING SLIDE RELEASE CABLE IAW AMM 25-62-43-PB401.SDR F3LA200700377Release Cable · inoperativeDURING C4/S1 CHECK, INSPECTION REPORTED LT OVERWING EMERGENCY EXIT SLIDE RELEASE CABLE WOULD NOT RETRACT. REMOVED AND REPLACED LT OVERWING EXIT SLIDE RELEASE CABLE IAW AMM 25-62-43-000-001. COMPLETED ADJUSTMENT AND OPERATIONAL CHECK OF SLIDE RELEASE CABLE IASDR DL76G071608Bottle · emptyLEFT OVERWING SLIDE BOTTLE FOUND EMPTY DURING ROUTINE CHECK BOTTLE REPLACED.SDR SWAA076167Slide · reads lowL2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA076172Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SB07106Bottle · low pressurePIT - MAINTENANCE REPORTED THE AFT LEFT ENTRY DOOR EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE WAS LOW. MAINTENANCE REMOVED AND REPLACED THE SLIDE ASSEMBLY PER MM 25-61-35.SDR MWE2008F00008Slide · inoperativeTAILCONE SLIDE PRESSURE AT (0). REMOVED AND REPLACED TAILCONE SLIDE. (K)
SDR UPS07851311Slide · dislodgedENTRY DOOR OPENED FROM OUTSIDE A/C BY LOAD SUP. SLIDE FELL OUT OF PACK, DID NOT INFLATE. REINSTALLED SLIDE AS REQUIRED IAW MM 25-60-01-2SDR F3LA200700367Hook · damagedDURING C-5 CHECK, INSPECTION REPORTED UPON INSTALLATION OF R2 DOOR SLIDE, OPEN/CLOSE HANDLE COULD BE OPERATED BEFORE DOOR WAS IN HOLE. REMOVED AND REPLACED HOOK ON DOOR LOCKING MECHANISM AND PERFORMED OPS CHECK AND RIG CHECK IAW AMM 52-13-21-400-001.SDR SWAA076075Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA076067Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS07M51271Slide · low pressureINSPECTION TYPE:N/A CREW PREFLIGHT - RIGHT (R1) DOOR SLIDE LOW PRESSURE. REMOVED AND REPLACED R1 DOOR SLIDE. REF MM 25-61-15-4.SDR 2007UALA05006Disc · rupturedL1 DOOR SLIDE HAS A LOW BOTTLE. FOUND RUPTURE DISC LEAKING. REPLACED RUPTURE DISC, SERVICED SYSTEM TO PROPER OPERATING LEVEL.SDR SWAA076078Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR DLM88071589Slide · unwanted deployR1 DOOR SLIDE WAY DEPLOYED WHEN DOOR WAS OPENED BY GATE GROMMET. THE DOOR WAS UNLATCHED AND THE GIRT BAR WAS NOT LOCKED IN THE CLIPS. GIRT/SLIDE WAS HANGING ON THE LOWER DOOR FRAME CUT OUT. REMOVED AND REPLACED R1 DOOR SLIDE PER OP 7035.SDR SWAA076031Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076027Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA076017Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR EIA2007206Slide · disconnectedRT EMERGENCY DOOR SLIDE PACK INFLATION BOTTLE DEPLOYMENT CABLE DETACHED. DEPLOYMENT CABLE RE-ATTACHED IAW 25-60-00.SDR 2007UALA04969Aspirator · leakingLEAKING ASPIRATOR.
SDR 2007UALA04962Switch · unknownSLIDE LIGHT AT DOOR 1R INOP. REARMED TARGET SWITCH AND SYSTEM OPERATES/TESTS NORMALLY.SDR SWAA076022Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.
Back to JASC 2565