Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA075347Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075329Hook · looseDURING SCHEDULED 16Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED HOOK PER SRM.SDR SWAA075314Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AALA20072024Slide · failedMSY - AFT GALLEY SERVICE DOOR SLIDE DISLODGED BY AIRCRAFT CLEANERS. DID NOT DEPLOY. REPLACED AFT GALLEY SERVICE DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR SWAA075275Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ASAA0742154Container · lack of lubeR1 DOOR EMERGENCY SLIDE TWISTED 90 DEGS DURING DEPLOYMENT AND USE DURING TEST BY FLIGHT CREW. LUBRICATED THE SLIDE CONTAINER LOWER FLAP HINGE (SHELF ASSY) WHICH WAS FOUND TO BE STIFF. SLIDE THEN DEPLOYED PROPERLY.SDR XXUA200700041Slide · reads lowDURING DAILY CHECK, FOUND R4 DOOR SLIDE PRESSURE LOW.SDR XXUA200700040Slide · reads lowDURING DAILY CHECK, FOUND LEFT EMERGENCY DOOR SLIDE PRESSURE LOW.SDR SWAA075238Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075241Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075256Fitting · corrodedDURING SCHEDULED 8Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR ASAA0742151Latch · misinstalledFLIGHT ATTENDANT UNABLE TO ARM L2 DOOR. FOUND LATCH ASSY INSTALLED INCORRECTLY. PROPERLY INSTALLED LATCH ASSY. (REF MM25 61 35 PG 209 & MM SUPP 25 61 35)SDR NOCA15907Slide · unwanted deployDOOR SLIDE 2L BLOWN ADVERTENTLY BY FLT ATTENDANT. THE 2L SLIDE PREVIOUSLY REMOVED REF PG 39524 ITEM 1M PAD 76. INSTALLED 2L SLIDE PER JOB CARD 25-029-01 AND AMM 25-66-01. OK FOR SERVICE.SDR DLM88071546Support · corrodedCORROSION ON AFT SLIDE SUPPORT AT L2. REPLACED SUPPORT PER SRM DWG 9930612.SDR DLM88071545Support · corrodedCORROSION ON FWD SLIDE SUPPORT AT L2 DOOR. REPLACED SUPPORT PER SRM 51-30-50, 51-10-4.SDR SWAA075213Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA04323Bottle · reads lowDOOR 2R SLIDE BOTTLE PRESSURE LOW. SERVICED DOOR ACCUMULATOR AS NEEDED. NO REPEATS SINCE ORIGINAL.SDR SWAA075182Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075183Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075184Cable · frayedDURING SCHEDULED C4 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR SWAA075196Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UHLA200710231Slide · mismanufacturedDURING A SCHEDULED OPS CHECK OF L1 DOOR AND SLIDE THE SLIDE EXTENDED INVERTED (COMPLETELY UPSIDE DOWN) WHICH CAUSED MINOR DAMAGE BENEATH L1 DOOR OPENING. THE FUSELAGE DAMAGE WAS ADDRESSED WITH AN IC2007-170/07425. THE SLIDE VENDOR HAS BEEN CONTACTED AND AN ISDR SWAA075158Bracket · looseDURING SCHEDULED MV1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR BRACKET LOOSE. ADJUSTED BRACKET PER MM.SDR SWAA075157Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT. INSTALLED EVAC SLIDE PER MM.SDR 2007UALA04327Slide · dislodgedDOOR 1L SLIDE FELL OUT OF CASING. SUSPECT SLIDE IMPROPERLY INSTALLED. REPLACED L1 DOOR SLIDE ASSEMBLY IAW MM-25-61-35. AC OK FOR SERVICE.SDR F3LA200700299Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON L1 DOOR GIRT BAR FITTING AFT BLANKING PLATE. REMOVED AND REPLACED L1 DOOR AFT GIRT BAR BLANKING PLATE IAW AMM 53-11-31-PB401.SDR F3LA200700298Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON L2 DOOR GIRT BAR FITTING BLANKING PLATE. REMOVED AND REPLACED L2 DOOR BLANKING PLATE IAW AMM 53-11-31-PB401.SDR 2007UALA04306Window · missingAFT GALLEY DOOR SLIDE COVER IS MISSING BOTTLE PRESSURE VIEWING WINDOW. SUSPECT CREW OR PASSENGER DISLODGED WINDOW. REMOVED SLIDE, INSTALLED NEW WINDOW & REINSTALLED SLIDE. AC OK FOR SERVICESDR SWAA075142Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075132Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075131Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075134Hook · looseDURING SCHEDULED BRDG CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED HOOK PER SRM.SDR SWAA075119Slide · unwanted deployDURING SCHEDULED RON CHECK, L1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA075122Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075120Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS07850941Slide · out of positionINSPECTION TYPE:N/A ESCAPE SLIDE NOT PROPERLY STOWED. REPACK ESCAPE SLIDE, OK FOR SERVICE.SDR F3LA200700300Blanking Plate · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON R2 DOOR FWD AND AFT GIRT BAR PADS. REMOVED AND REPLACED FWD AND AFT R2 DOOR GIRT BAR BLANKING PLATES IAW AMM 52-13-31-PB401 AND 52-13-31-400-007.SDR F3LA200700296Web · corrodedDURING C4/S1 CHECK, INSPECTION REPORTED CORROSION AT FWD CARGO COMPARTMENT FLOOR WEB NUTPLATES, RT SIDE WHERE TRANSITION PANEL AND FLOOR MEET, BETWEEN FR 28 AND FR 29. REMOVED AND REPLACED CORRODED TRANSITION STRIP IAW SRM 51-42-11 AND 51-44-11.SDR AMTA200700555Light · inoperativeDURING PRE FLIGHT 4L DOOR SLIDETEST LIGHT WOULD NOT PRESS TO TEST. RELAMP SLIDEPACK PRESSURE INDICATOR. OPS CHECK NORMAL IAW 25-61-01. (M)SDR AMTA200700554Slide · no testDURING PREFLIGHT, DOOR SLIDE TEST LIGHT WOULD NOT PRESS TO TEST. RELAMPED SLIDEPACK PRESSURE INDICATOR. OPS CHECK NORMAL IAW 25-61-01. (M)SDR ABXA070348Girt Bar · malfunctionedMAIN ENTRY DOOR SLIDE WOULD NOT ARM. FOUND GIRT BAR LOCK PANEL NOT TURNING. INSTALLED BUSTLE. OPERATED EMERGENCY ESCAPE SLIDE IAW B767 AMM 25-66-01-4-10. OPS CHECKED GOOD.SDR SWAA075101Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075102Slide · out of adjustDURING SCHEDULED BRDG CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR DLM88071544Support · corrodedCORROSION RT AFT SLIDE SUPPORT AT R1 DOOR. REPLACED SUPPORT PER SRM 51-30-1, 51-10-4.SDR DLM88071543Support · corrodedCORROSION ON FWD SLIDE SUPPORT AT R1, REPLACE SUPPORT PER SRM 51-30-1, 51-10-4.SDR 2007UALA04253Slide · faultyDOOR 1L SLIDE ASSY AFT ATTACH FITTING BROKEN. REPLACED DOOR 1L SLIDE ASSY.SDR SWAA075081Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA04209Power Supply · faultyAFTER REPLACING SLIDE AT DOOR 1L EMERGENCY TEST FAULTED EPSU BATTERY L. REPLACED BATTERY AT 1L AND GOT EPSU UNIT L. 10-26-07 FOUND FAULTY EPSU. REPLACED EPSU- NO REPEATS SINCE ORIGINAL.SDR SWAA075062Slide · out of adjustDURING SCHEDULED A2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF AJDJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA075063Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.
Back to JASC 2565