Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA072775Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2007UALA01746Bottle · unserviceableLOW BOTTLE PRESSURESDR AALA20070993Slide · inoperativePVG - DURING AIRCRAFT SERVICING LEFT NUMBER FOUR DOOR SLIDE WAS DISLODGED FROM BUSTLE HOUSING AND BACKBOARD. SLIDE DID NOT DEPLOY. SUSPECT HOUSING STRUCK BY CATERING EQUIPMENT. REPLACED LEFT NUMBER FOUR DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2007UALA01736Bottle · low pressureCREW REPORT: DOOR 1R SLIDE PRESSURE READS LOW 1200.SDR 2007UALA01734Slide · faultyL-1 DOOR HARD TO ARM AND DISARM. [06-20-07] REMOVED AND REPLACED SLIDE DUE TO SKIRTING MATERIAL INTERFERING WITH GIRT BAR,SDR 2007UALA01722Valve · leakingLOW BOTTLE PRESSURE. THERE WAS A SMALL LEAK IN THE FILLER VALVE. REPLACED WITH NEW FILLER VALVE. REPLACED BOTTLE WITH A STOCK BOTTLE AND REPAIRED THE OLD BOTTLE AND PUT BACK IN STOCK.SDR ZZDA070529172Slide · low pressureR1 DOOR SLIDE GAUGE IS IN THE RED. REMOVED AND REPLACED R-1 DOOR SLIDE REF B717 AMM 25-61.SDR SWAA072725Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA072726Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072691Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01665Cover · debondedDOOR 1L PLASTIC CLEAR COVER OVER THE ESCAPE SLIDE PRESS GAUGE IS DISBONDED. [07-03-07] REPLACED SLIDE ASSEMBLY.SDR 2007UALA01656Bottle · reads lowDOOR ASSIST BOTTLE PRESSURE AT DOOR 1L READS ZERO.SDR DL757070669Lanyard · looseFOUND LT OVERWING SLIDE PACK PARTIALLY DEPLOYED DURING ROUTINE DEACTIVATION OF EMEGENCY ESCAPE SYSTEM. LANYARD WAS PULLED FREE FROM SLIDE PACK. C/W OPN 7809 NR 1L ESCAPE DOOR SLIDE REPLACEMENT REF RC 650-651.SDR 2007UALA01687Slide · defectiveRIGHT OVERWING SLIDE TRIGGER HITTING ON AFT SUPPORT WHEN CLOSING DOOR. [07-10-07] REPLACED SLIDE BECAUSE RT OVERWING SLIDE FABRIC BINDING AT UPPER AFT AREA WHEN CLOSING SLIDE DOOR. ROOT CAUSE IS SUSPECTED SLIDE CAME PARTIALLY UNPACKED THROUGH MULTIPLE DOOR SDR 2007UALA01681Slide · unsecureDOOR SLIDE 1L FELL OUT ON TO AIR STAIR DUE TO NOT BEING DISARMED. [06-20-07] REMOVED AND REPLACED DOOR 1 LT SLIDE AND EMERGENCY POWER RESERVOIR.SDR SWAA072684Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072680Slide · out of adjustDURING SCHEDULED A2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072674Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS07849861Slide · unsecureTHE FWD ENTRY EMERGENCY EXIT SLIDE IS SLIPPING OUT OF THE RETAINING COMPARTMENT. REPACKED FWD ENTRY EMERGENCY ESCAPE SLIDE IAW MM 25-60-01-2.SDR UPS07849859Slide · unsecureINSPECTION TYPE:N/A THE FWD ENTRY DOOR EMERGENCY SLIDE IS SLIPPING OUT OF ITS CONTAINER. FWD ENTRY DOOR SLIDE RESECURED IAW DC8 AMM 25-60-01-2.SDR 2007UALA01672Pin · pulledDOOR L2 SLIDE, PIN IS PULLED OUT OF STITCHING. [06-20-07] REPLACED A FAILED SLIDE.SDR SWAA072669Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA072670Slide · low pressureDURING SCHEDULED SERVICE CHECK, L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR UPS07849863Gauge · out of positionINSPECTION TYPE:N/A ENTRY DOOR SLIDE PRESSURE GAUGE NOT VISIBLE. REPOSITIONED SLIDE SO PRESSURE GAUGE CAN BE READ.SDR UPS07849860Slide · dislodgedSLIDE FELL OUT OF CONTAINER WHEN OPENING EXIT DOOR. REINSTALLED SLIDE IAW MM 25-60-01-2.SDR 2007UALA01641Slide · looseRIGHT OFFWING ESCAPE SLIDE DOOR LOOSE ON AFT END WHEN CLOSED AND LATCHED. [06-20-07] SHIMMED EMERGENCY ESCAPE SLIDE DOOR TO FIT TIGHT. CHECKED FIT AND FAIR WITH FUSE AND FOUND OK.SDR 2007UALA01640Cylinder · out of toleranceLEFT OFFWING SLIDE INFLATION CYLINDER EXCEEDS LIFE LIMIT. [06-20-07] REPLACED LT OFF WING SLIDE CYLINDER.SDR SWAA072653Slide · out of adjustDURING SCHEDULED SERVICE CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072650Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072649Slide · out of adjustDURING SCHEDULED RON CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072638Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072623Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA072641Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072639Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072628Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072640Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072626Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR F3LA200700119Girt Bar · corrodedDURING C-3 CHECK, INSPECTION REPORTED L2 FWD GIRT BAR FITTING AND HARDWARE CORRODED. REPLACED GIRT BAR BLANKING PLATE IAW 52-13-31-400-007.SDR F3LA200700118Girt Bar · corrodedDURING C-3 CHECK, INSPECTION REPORTED R2 FWD GIRT BAR FITTING AND HARDWARE CORRODED. REPLACED GIRT BAR BLANKING PLATE IAW AMM 52-13-31-400-007.SDR 2007UALA01601Slide · unsecureDOOR 1L SLIDE PACK APPEARS TO BE HANGING OUT TOO MUCH. [SUP 05-29-07] REMOVED AND READJUSTED SLIDE PACK. REINSTALLED.SDR 2007UALA01591Bottle · reads lowLOW BOTTLE PRESSURE. WATER TESTED FOR 10 MINUTES AND NO LEAK WAS FOUND. REPLACED WITH A STOCK BOTTLE AND TOPPED OFF OLD BOTTLE AND PUT BACK IN STOCK.SDR SWAA072584Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072610Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072597Girt Bar · corrodedDURING SCHEDULED 22Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA072596Girt Bar · corrodedDURING SCHEDULED 22Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA072576Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072580Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA072647Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01594Gauge · leakingDOOR 2L SLIDE-RAFT BOTTLE PRESSURE IS REPORTED TO BE AT BOTTOM OF GREEN BAND. [06-15-07] THE GAUGE WAS LEAKING OUT OF THE CENTER SHAFT. REMOVED & REPLACED GAUGE. PERFORMED SECURITY CHECK PER MM & AIRCRAFT OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE WAS WEASDR DLM90070579Lanyard · out of adjustWHEN TAILCONE INADVERTENTLY DEPLOYED SLIDE DID NOT DEPLOY. FOUND THAT ONE OF THE FLOOR MOUNTED ATTACH POINTS FOR THE LANYARD WAS INCORRECTLY ADJUSTED. ADJUSTED ATTACH POINT AS REQUIRED.
Back to JASC 2565