Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA072539Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01577Lamp · inoperativeCREW REPORT: DOOR 3L SLIDE LIGHT WON`T ILLUM WITH DOOR ARMED. [06-20-07] SLIDE LIGHT RELAMPED.SDR 2007UALA01557Cover · unsecureCREW REPORT: 2 RT DOOR HANDLE COVER SEPARATED FROM A-C. [06-26-07] RESECURED SLIDE COVER.SDR SWAA072516Slide · low pressureDURING SCHEDULED BRDG CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA072515Slide · out of adjustDURING SCHEDULED MV3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01553Slide · low pressureDOOR 2R SLIDE PRESSURE OUT OF LIMITS. [06-14-07] THERE WAS A SMALL LEAK AT THE SHAFT O-RING. REPLACED NR 2 RT SLIDE.SDR SWAA072511Slide · out of adjustDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SB07040Slide · no testPHL - THE FORWARD RIGHT HAND SERVICE DOOR EMERGENCY ESCAPE SLIDE FAILED THE ANNUAL OPERATIONAL TEST WHEN IT TWISTED DURING DEPLOYMENT. MAINTENANCE REPLACED THE SLIDE. INSPECTED OK FOR SERVICE.SDR 2007UALA01538Line · wornNR 1 MED SLIDE MOORING LINE WORN THRU 80 PERCENT. [06-26-07] REPLACED NR 1 SLIDE.SDR SWAA072426Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072413Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072436Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072416Hook · looseR1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED GIRT BAR HOOK PER MM.SDR SWAA072441Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AMTA200700236Slide · no testL-3 DOOR SLIDE FAILED TO DEPLOY ON TEST (AUTO AND MANUAL). REINSTALLED SLIDE SN CC213 FOR EVACUATION TEST IAW AMM-25-61-01. (K)SDR AMTA200700237Slide · no testR4 DOOR SLIDE FAILED TO DEPLOY ON TEST (AUTO AND MANUAL). REINSTALLED SLIDE SN 004456 FOR EVACUATION TEST IAW MM 25-61-01. (K) REPLACED SLIDE IAW MM 25-61-01. (K)SDR AWXA200700645Slide · damagedSAL - EES - BC-4 CHECK - THE R1 DOOR EMERGENCY ESCAPE SLIDE WAS FOUND TO BE EXPANDED/PARTIALLY INFLATED DURING A VISUAL INSPECTION OF THE SLIDE. THE R1 DOOR EMERGENCY ESCAPE SLIDE WAS REPLACED IAW AWA TASK CARD R1C25311.SDR AWXA200700644Slide · damagedSAL - EES - BC-4 CHECK - THE R2 DOOR EMERGENCY ESCAPE SLIDE WAS FOUND TO BE EXPANDED/PARTIALLY INFLATED DURING A VISUAL INSPECTION OF THE SLIDE. THE R2 DOOR EMERGENCY ESCAPE SLIDE WAS REPLACED IAW AWA TASK CARD R1C25311.SDR AWXA200700643Slide · damagedSAL - EES - BC-4 CHECK - THE L1 DOOR EMERGENCY ESCAPE SLIDE WAS FOUND TO BE EXPANDED/PARTIALLY INFLATED DURING A VISUAL INSPECTION OF THE SLIDE. THE L1 DOOR EMERGENCY ESCAPE SLIDE WAS REPLACED IAW AWA TASK CARD R1C25311.SDR 2007UALA01513Slide · low pressureLOW BOTTLE PRESSURE. [SUP 06-06-07] NO LEAK FOUND, WATER TESTED FOR 15 MIN. TOPPED OFF BOTTLE PRESSURE AND LET SIT FOR 24 HOURS.SDR SWAA072412Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072411Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01508Lanyard · misroutedTHE 2L WILL NOT ARM. [SUP 06-06-07] REROUTED LANYARD CHORD AND THAT APPEARED TO FIX THE PROBLEM.SDR SWAA072403Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA072404Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA01495Cover · looseDOOR 1R SLIDE COVER LOOSE. [SUP 05-29-07] SECURED COVER.SDR 2007UALA01493Slide · out of position2R DOOR SLIDE COMING OUT OF SLIDE PACK. [06-14-07] REPLACED SLIDE.SDR SWAA072387Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072388Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR MWEA070116Bottle · low pressureTAIL CONE EVACUATION SLIDE BOTTLE PRESSURE GAUGE NOT IN THE GREEN BAND. REMOVED AND REPLACED TAIL CONE SLIDE ASSEMBLY.SDR 2007UALA01482Cylinder · low pressurePRESSURE IN CYLINDER NOT IN LIMITS. NO LEAK WAS FOUND. REPLACED WITH ANOTHER BOTTLE.SDR 2007UALA01466Bottle · reads lowEMERGENCY ESCAPE LIGHT REMAINED EXTINGUISHED DURING SLIDE SQUIB TEST 2 ON SIDE 5 (05=L, 06=R). [SUP 06-06-07] FOUND LEFT OVERWING EVAC SLIDE BOTTLE PRESS LOW. ACCOMPLISHED A ONE TIME RECHARGE. SQUIB TEST OK. CYLINDER REPLACED AT FIRST MAINT STATION WHERE PSDR 2007UALA01457Slide · looseDOOR 1L SLIDE PACK APPEARS TO BE LOOSE. REPLACED SLIDE ASSY.SDR SWAA072364Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA072355Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072357Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ZZDA070509161Fitting · missingL1 DOOR SLIDE PACK MISSING A CLIP. REMOVED AND REPLACED L1 DOOR SLIDE ASSY REF AM/M 25-61.SDR 2007UALA01467Girt Bar · stiffDOOR 3R DOOR ARM DISARM SWITCH VERY STIFF AND DIFFICULT TO USE. [SUP 06-06-07] REMOVED SLIDE LUBED MECHANISM TO ALLEVIATE THE STIFFNESS CONDITION.SDR 2007UALA01450Disk · rupturedLOW BOTTLE PRESSURE. LEAKING THROUGH RUPTURE DISK. REPLACED RUPTURE DISK.SDR UPS07149777Slide · unwanted deployINSPECTION TYPE:N/A SLIDE DEPLOYED WHEN CLOSING MAIN CARGO DOOR PRIOR TO BLOCKOUT. INSTALLED NEW SLIDE IAW M/M 25-61-21-04. SERVICED FWD DOOR DAMPER AND EMERGENCY OPERATION CYLINDER IAW M/M 52-10-14-03. THIS CLEARS M-350038.SDR SWAA072349Slide · out of adjustDURING SCHEDULED MV3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01419Bulb · faultyNUMBER 1 SQUIB TEST FAILURE FOR LEFT EMERGENCY ESCAPE SLIDE. CLEANED AND RELAMPED BULB. [SUP 06-06-07] CLEANED AND RELAMPED BULB. ACCOMPLISHED SQUIB TEST SEVERAL TIMES ON P61 PANEL. TESTED OK.SDR CALA0700229Slide · low pressureINSPECTION FOUND THE R-1 DOOR SLIDE HAD LOW PRESSURE. THE SLIDE WAS REMOVED AND REPLACED IAW MM 25-66-01.SDR SWAA072351Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA072260Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072259Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. REINSTALLED EVAC SLIDE PER MM.SDR SWAA072244Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA072247Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS07849749Slide · missingINSPECTION TYPE:N/A ESCAPE SLIDE NOT IN DOOR. INSTALLED ESCAPE SLIDE ON DOOR IAW MM 25-60-01-2.SDR 2007UALA01392Bottle · low pressureLOW BOTTLE PRESSURE. [SUP 05-16-07] SMALL PIN HOLE LEAK AROUND FILLER VALVE AND BAD O-RING. REPLACED O-RING AND FITTING CHARGE.
Back to JASC 2565