SDR 2007UALA00485O-Ring · deterioratedLOW BOTTLE PRESSURE. REPLACED SLIDE. A/C RETURNED TO SERVICE. SLIDE PROBLEM ROOT CAUSE: FOUND FILLER VALVE LEAKING CAUSING LOW BOTTLE PRESSURE. SUSPECT O-RING DETERIORATION LEAD TO LEAKAGE.SDR 2007UALA00484O-Ring · misinstalledLOW BOTTLE PRESSURE. REPLACED SLIDE. A/C READY FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: FOUND LOOSE LOCK NUT ON CONNECTION TO PRESSURE BOTTLE. SUSPECT IMPROPER TORQUING DURING RESTORATION.SDR 2007UALA00459Pin · bindsFWD RIGHT MED EMERGENCY EVACUATION SLIDE INFLATION BOTTLE SAFETY PIN INSERTION WAS EXTREMELY HARD. [SUP 05-16-07] FWD RT EMERGENCY SLIDE WAS REPLACED. IT WAS LATER DETERMINED THAT THE INFLATION BOTTLE REGULATOR VALVE WAS OUT OF POSITION, WHICH WAS CAUSING THSDR SWAA070862Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR ZZDA070215137Slide · unwanted deployA/C CLEANERS DEPLOYED R1 SLIDE BY OPENING DOOR. REMOVED AND REPLACED R1 DOOR SLIDE IAW AMM 25-66-01 SHELF LIFE EXP 4-30-09, HYDRO STATIC TEST DATE 07-05.SDR DHL2007364007Mechanism · contaminatedLEFT MAIN DOOR SLIDE WARNING LIGHT FLASHING IN FLIGHT WITH SLIDE ARMED AND NO DOORS LIGHT ILLUMINATED. REMOVED ICE DEBRIS FROM LT DOOR SLIDE ARMING MECHANISIM. OPS CK GOOD IAW AMM 52-10-30.SDR 2007UALA00483Bottle · low pressureLOW BOTTLE PRESSURE. LEAKING AROUND THREADS ON GAUGE, TEFLON TAPE PULLED AWAY FROM THREADS ON GAUGE. RESEALED W/TEFLON TAPE AROUND GAUGE THREADS.SDR 2007UALA00465Hose · kinkedRIGHT OVERWING SLIDE INFLATION HOSE KINKED NEAR REGULATOR END. [SUP 05-16-07] REPLACED OVERWING SLIDE INFLATION BOTTLE. INSTALLATION ERROR FROM PREVIOUS REPLACEMENT.SDR 2007UALA00462O-Ring · failedLEFT OFF-WING SLIDE CYLINDER HAS LOW BOTTLE PRESSURE AND WHITE INDICATOR IS NOT IN THE ARM INDICATOR WINDOW. REPLACED CYLINDER PER MM 25-65-02. A/C READY FOR SERVICE. SUSPECT O'RINGS LEAKING DUE TO HARDENING.SDR 2007UALA00457O-Ring · failedFLIGHT ATTENDANT REPORTS DOOR 4L SLIDE PRESSURE LOWER THAN 2000 PSI. SLIDE ASSY PRESSURE CHECKS NORMAL RANGE. SLIDE PROBLEM ROOT CAUSE: LEAKING O'RINGS HARDENED BY TIME IN POSITION & COLD.SDR SWAA070804Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070803Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA070814Slide · out of adjustDURING SCHEDULED 12Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070806Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AMTA200700101Bottle · unserviceableRT EMERGENCY ESCAPE TEST LT IS ILLUMINATING (DIM) AT ALL TIMES. REPLACED RT EMER ESCAPE BOTTLE IAW AMM 25-65-02. CHECKS NORMAL. (K)SDR SWAA070750Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA070753Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2007UALA00433Fastener · looseVELCRO LOOSE 2R SLIDE. UNDETERMINED CAUSE. SECURED VELCRO.SDR SWAA070736Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR AALA20070311Slide · inoperativeLAS - RAMP SERVICE FOUND SLIDE PACK AT LEFT SERVICE DOOR BROKEN AND ON GROUND. CATERING DROPPED SLIDE WHEN SERVICING AIRCRAFT. SLIDE DID NOT DEPLOY. REPLACED SLIDE FOR LEFT SERVICE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2007UALA00393Slide · low pressureTHE 4R DOOR SLIDE PRESSURE READS LOW. REPLACED DOOR SLIDE.SDR SWAA070719Girt Bar · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA070720Girt Bar · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA070705Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070711Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA00434Slide · faultyFOUND AT PTP PANEL TEST LEFT INTER EXTERNAL FAULTS. [SUP 05-16-07] REPLACED THE LT OVERWING SLIDE ASSEMBLY. AT OVERHAUL, DETERMINED THAT THE PACK BOARD WAS FAULTY.SDR 2007UALA00373Squib · failedRIGHT OVERWING INTEGRATOR SQUIB FAILED SQUIB TEST. TROUBLESHOT SYSTEM TO BAD TIME DELAY RELAY (M1) ON RIGHT OFF-WING EXCAPE SYSTEM MODULE. REPLACED RELAY 10167-2001BT PER MM 25-65-00 AND 25-65-12 AND OPS CHECK GOOD. SLIDE PROBLEM ROOT CAUSE: RELAY DIRTY & SDR 2007UALA00372Slide · lowNR 1 LEFT MED DOOR SLIDE INFLATION CYLINDER NEEDLE IS JUST OUT OF GREEN BAND ON THE LOW SIDE. LAST OVERHAUL DATE IS APR05. REPLACED SLIDE.SDR 2007UALA00371Linkage · out of adjustDOOR 2R FAILS ARM-DISARM CHECK. ADJUSTED LINKAGE BETWEEN SELECTOR LEVER AND GIRT BAR MECH. ADJUSTED PUSH ROD AND GIRT BAR CARRIER, NO COMPONENTS REPLACED.SDR 2007UALA00364Indicator · reads lowTHE 1L SLIDE PACK NEEDLE READS LOW. ALLOWED INFLATION CYLINDER TEMP TO STABILIZE. PRESSURE GAUGE NEEDLE IS WITHIN LIMITS. REPLACED MED 1L SLIDE. ALL SAFETY PINS WERE REMOVED AND STOWED.SDR 2007UALA00362Slide · looseRIGHT NR 2 SERVICE DOOR SLIDE FOUND PARTIALLY UNLACED. REMOVED R-2 DOOR SLIDE AND REINSTALLED SLIDE RELEASE CABLES PER MM 25-66-00. THEN, REINSTALLED SLIDE. A/C OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT VIBRATION AND OPEN/CLOSE CYCLE LOOSENED LACINGSDR 2007UALA00355Proximity Switch · inoperativeDOOR 2L SLIDE DOES NOT INDICATE AN ARMED IND WHEN ARMED. RECYCLED 2 TIMES, NO LUCK. [SUP 05-08-07] FAULTY PROXIMITY SWITCH. REPLACED SWITCH AND ADJUSTED TO PROPER CLEARANCE.SDR SWAA070666Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR SWAA070670Girt Bar · crackedDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CRACKED. REMOVED AND REPLACED AFT GIRT BAR FITTING PER MM.SDR 2007UALA00356Cover · out of positionSLIDE COVER AT DOOR 2L FELL OFF DOOR. [SUP 05-08-07] REPLACED SLIDE COVER.SDR 2007UALA00353Proximity Switch · out of adjustLEFT AFT SLIDE INDICATION INOP ON DOOR-OXY SYSTEM ECAM PAGE - DOOR-OXY. [SUP 05-08-07] OUT OF ADJUSTMENT PROXIMITY SWITCH.SDR UPS07849138Girt Bar · stiffINSPECTION TYPE:N/A THE EMERGENCY ESCAPE SLIDE GIRT BAR IS VERY DIFFICULT TO ENGAGE & DISENGAGE. REPACKED EMERGENCY ESCAPE SLIDE IN ITS CONTAINER. GIRT BAR STOWS OK.SDR SWAA070654Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070641Slide · low pressureL2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA070642Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA00336Lever · faultyDOOR 1R DISARM LEVER HARD TO DISARM. CREW REPORTS LEVER MOVED FORCEFULLY TO DISARM AND HEARD UNUSUAL NOISE, DOOR APPEARS TO BE DISARMED. CLEANED DEBRIS AND ICE FROM GIRT BAR SENSOR AREA. ARM LEVER NOW NORMAL. NO COMPONENTS REPLACED.SDR 2007UALA00335Line · exposedDOOR 2L SLIDE MOORING LINE PARTLY EXPOSED. PUT MOORING LINE BACK INTO VELCRO LINER.SDR F3LA200700022Control Cable · stuckDURING C-3 CHECK, INSPECTION REPORTED RT FLEXIBLE CONTROL CABLE FOR OVERWING SLIDE INFLATION BOTTLES WOULD NOT RETRACT. REPLACED RT FLEXIBLE CONTROL CABLE FOR OVERWING SLIDE INFLATION BOTTLE IAW AMM 25-62-43-000-001, AMM 25-62-43-400-001, MM 25-23-43, PB 401,SDR MWEA070027Slide · detachedDOOR SLIDE FORWARD ENTRY DOOR DISCONNECTED FROM HANGER. REINSTALLED FORWARD ENTRY DOOR SLIDE.SDR ASAA0741443Cable · misroutedEVAC SLIDE NEW FROM STOCK INFLATION CABLE MISROUTED AT GIRT FROM MANUFACTURES OVERAHUL. REROUTED INFLATION CABLE PRIOR TO INSTALLATION.SDR SWAA070629Slide · out of adjustDURING SCHEDULED SPV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR F3LA200700021Reservoir · damagedDURING C-3 CHECK, INSPECTION REPORTED CABLE END ON LT OVERWING EMERGENCY SLIDE INFLATION BOTTLE BROKEN OFF. REPLACED LT INFLATION RESERVOIR OVER-WING ESCAPE SLIDE IAW AMM 25-62-46-000-001 AND 25-62-46-400-001. CONNECTED LT OVERWING ESCAPE SLIDE CABLE IAW 25-6SDR MWEA070042Cable · detachedFORWARD ENTRANCE DOOR ESCAPE SLIDE CABLE DETACHED. RESECURED LOWER LATCH FOR FORWARD ENTRANCE DOOR SLIDE.SDR 2007UALA00330Light · inoperativeEMERGENCY LIGHTS INOP AT SEATS 17G, 9F FWD LT & 2F AFT LT. REPLACED EEL LIGHT ASSY'S AT SEATS 17G, 9F-FWD LT, & SEAT 2F-AFT LT. ALL POSITIONS OP CHECKED GOOD.SDR 0700529620Slide · inoperativeLOCAL VENDOR AT SYR ATTEMPTED TO STOW TAIL CONE RELEASE HANDLE AND INADVERTENTLY JETTISONED THE TAIL CONE. SEE LP NR 3832775. THE TAIL CONE EMERGENCY ESCAPE SLIDE DID NOT DEPLOY AND DID NOT INFLATE. NO OBVIOUS REASON FOR FAILURE OF THE SLIDE TO DEPLOY AS DE
Back to JASC 2565