Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA070604Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA00315Cable · faultyFLIGHT ATTENDANTS REPORT DOOR 4 RIGHT IS FROZEN AND WILL NOT DISARM. DOOR 4R UNABLE TO DISARM. RAISED TEMP IN AC TO THAW DOOR ARMING CABLE. CYCLED DOOR AND ARM DISARM LEVER NUMEROUS TIMES. APPLIED ICE RELEASE TO DOOR AND GIRT BAR MECH. PROBLEM REPEATED IN DSDR 2007UALA00305Lifter · wornFOUND DOOR 4R AND 4L AFT GIRT BAR LIFTERS HAVE WORN AREAS.SDR 2007UALA00304Lifter · wornFOUND DOOR 4L AND 4R FWD GIRT BAR LIFTERS HAVE WORN AREAS. WEAR OUT OF LIMITS, REPLACED LIFTER.SDR 2007UALA00299Girt Bar · out of positionFOUND PASSENGER DOOR L1 SLIDE GIRT IS NOT PROPERLY STOWED ON THE SLIDE. REPACKED GIRT BAR MATERIAL.SDR F3LA200700015Girt Bar · corrodedDURING C-3 CHECK, INSPECTION REPORTED R2 AFT GIRT BAR PLATE CORRODED. REPLACED R2 DOOR AFT GIRT BAR PLATE IAW MM 52-13-31. REPLACED R2 DOOR AFT GIRT BAR FITTING BLANKING PLATE IAW AMM 52-13-31400-007.SDR F3LA200700014Girt Bar · corrodedDURING C-3 CHECK, INSPECTION REPORTED R2 FWD GIRT BAR PLATE CORRODED. REPLACED R2 DOOR FWD GIRT BAR PLATE IAW MM 52-13-31. REPLACED R2 DOOR FWD GIRT FITTING BLANKING PLATE IAW MM 52-13-31.SDR F3LA200700013Girt Bar · corrodedDURING C-3 CHECK, INSPECTION REPORTED L2 FWD GIRT BAR PLATE CORRODED. REPLACED L2 DOOR GIRT BAR PLATE IAW AMM 52-13-31. REPLACED L2 DOOR GIRT BAR BLANKING PLATE IAW AMM 52-13-31-400-007.SDR MWEA070026Slide · low pressureAFT EVACUATION SLIDE PRESSURE IS LOW AT 1500 PSI. REMOVED AND REPLACED AFT SLIDE.SDR F3LA200700012Plate · corrodedDURING C-3 CHECK, INSPECTION REPORTED L2 AFT GIRT BAR PLATE CORRODED. REPLACED L2 DOOR GIRT BAR PLATE PER MM 52-13-31. REPLACED L2 DOOR GIRT BAR FITTING BLANKING PLATE PER AMM 52-13-31-400-007.SDR 2007UALA00287Cylinder · out of toleranceRIGHT & LEFT OFFWING SLIDE CYLINDERS ARE OUT OF TOLERANCE. RT OFFWING SLIDE CYLINDER LIMIT OVERDUE, DATE OF MANUFACTURE 4-92. CYLINDER NOT OUT OF DATE DOD, 26JAN07, BUT WILL NOT HAVE 20 MONTHS REMAINING. REPLACED CYLINDER. OPS CHECK SQUIB TEST FOR NORMAL RSDR 2007UALA00285Aspirator · leakingASPIRATOR LEAKING. SLIDE REPLACED. A/C OK FOR SERVICE. LEAKING ASPIRATOR ATTRIBUTED TO CUTTING OF METAL BELLOWS BY ACCIDENTAL IMPACT OR CRUSH WHILE PACKING.SDR 2007UALA00284Seal · leakingLEAKING ASPIRATOR IN RIGHT OVER-WING ESCAPE SLIDE. SLIDE REPLACED. A/C OK FOR SERVICE. LEAKING ASPIRATOR ATTRIBUTED TO SEAL LEAK AT THE BASE OF METAL BELLOWS.SDR F3LA200700011Cylinder Damper · failedWHILE PERFORMING OPS TEST OF SLIDE DEPLOYMENT PER TC 25830-1, L1 DOOR ASSIST BOTTLE DID NOT FULLY OPEN DOOR TO DEPLOY SLIDE. REPLACED L1 DOOR CYLINDER DAMPER ASSY IAW MM 52-11-14-000-001 AND 52-11-14-400-001, PARA 4 A-D AND 5 A-C. SERVICED AND PERFORMED PRESSDR SWAA070496Hook · looseDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED GIRT BAR HOOK PER MM.SDR SWAA070494Plate · corrodedDURING SCHEDULED 18Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FLOOR ATTACH PLATE CORRODED. REMOVED AND REPLACED ATTACH PLATE PER SRM.SDR UPS07149072Pin · stuckUNABLE TO REINSTALL DOOR SLIDE SAFETY PIN AFTER THE SLIDE LEVER WAS MOVED TO DISARM POSITION. CYCLED SLIDE LEVER SEVERAL TIMES. INSERTED PIN IN DISARM POSITION SATISFACTORILY EACH TIME. OK TO CONTINUE.SDR UPS07849040Girt Bar · damagedGIRT BAR DIFFICULT TO ARM, NOT ENOUGH MATERIAL TO PULL BAR INTO PLACE. ADJ EVAC SLIDE IN CONTAINER. GIRT BAR OPERATIONAL NORMAL, REF MM 25-60-01-2.SDR SA07007Girt Bar · detachedDEN - THE FORWARD LEFT MAIN ENTRY DOOR EMERGENCY ESCAPE SLIDE GIRT BAR WAS FOUND DETACHED. MAINTENANCE SECURED THE GIRT BAR. OPERATIONALLY CHECKED OK.SDR 2007UALA00258Slide · unwanted deployDOOR 1L SLIDE MAY BE PARTIALLY DEPLOYED. REINSTALLED SLIDE PACK IN CONTAINER.SDR 2007UALA00252Cable · misroutedDOOR 2R DOOR SLIDE GIRT BAR INFLATION CABLE ROUTED INCORRECTLY. GIRT BAR INFLATION CABLE ROUTED INCORRECTLY. ROUTED CABLE CORRECTLY.SDR SWAA070463Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA00246Light · inoperativeDOOR 2R SLIDE GIRT BAR ENGAGEMENT LIGHT INOP. CLEANED SOCKET, ARMED AND DISARMED DOOR 2R SEVERAL TIMES AND LIGHT FUNCTIONED NORMALLY. THE DISCREPANCY IS ATTRIBUTED TO SHORTING OF CONNECTION DUE TO ACCUMULATION OF DIRT. THERE WAS NO NEED TO CHANGE ANY PARTSDR 2007UALA00231Hose · crushedRIGHT OVERWING ESCAPE SLIDE UPPER PRESSURE HOSE FOUND COLLAPSED INSIDE PANEL 196ER. HOSE REPLACED AND NEW 8130-3 ISSUED. SAME SLIDE REINSTALLED. OK FOR RETURN TO SERVICE. SUSPECT PANEL INSTALLATION CRUSHED HOSE.SDR 2007UALA00224O-Ring · leakingDOOR 4 RIGHT SLIDE BOTTLE PRESSURE OUT OF GREEN BAND. REPLACED SLIDE ASSY. A/C RETURNED TO SERVICE. SUSPECT O-RING LEAK AT BOTTLE CONNECTION.SDR SWAA070435Slide · inoperativeL1 DOOR EMERGENCY EVAC SLIDE INOP. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA00226Harness · buckledSLIDE ASSY HARNESS BUCKLES AT DOOR 1L WILL NOT LATCH SLIDE PACK CORRECTLY ONTO DOOR ASSY. REPLACED SLIDE ASSY HARNESS AS WELL AS SLIDE ASSY. CAUSE OF FAILURE NOT ESTABLISHED AT THE TIME.SDR SWAA070411Slide · low pressureDURING SCHEDULED MV1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA00215Slide · unserviceableFOUND SLIDE TUBE BLOWN. CAUSE UNKNOWN. REPLACED SLIDE.SDR AALA20070184Slide · inoperativeMIA - LEFT NUMBER ONE DOOR SLIDE FELL OUT OF HOUSING WHEN DOOR OPENED. UNSUCCESSFUL DEPLOYMENT. FOUND DEBRIS AT GIRT BAR. CLEARED DEBRIS FROM GIRT BAR AREA AND REINSTALLED LEFT NUMBER ONE DOOR SLIDE AND POWER ASSIST BOTTLE. SYSTEM GROUND CHECKED NORMAL OPESDR 2007UALA00200Latch · crackedRT OVERWING SLIDE COMPARTMENT DOOR LATCH (NR4 AFT), SLIDER IS CRACKED, SPLIT ALONG FWD, OUTBD, AND AFT EDGES. DID NOT PASS INTEGRATOR TORQUE TEST. REMOVED AND REPLACED LATCH PER MM 25-65-09 AND OPS TEST GOOD. SUSPECT SLIDER HAD MANUFACTURING FLAW.SDR SWAA070372Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070359Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA070338Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070339Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS07149031Slide · inoperativeINSPECTION TYPE:N/A ESCAPE SLIDE INOP. M342678 D/D 1/26/07. INSTALLED SERVICEABLE ESCAPE SLIDE WITH REF TO MM 25-61-21-04. THIS CLEARS M342678.SDR 2007UALA00172Aspirator · unserviceableBOTH ASPIRATORS LEAKING. SLIDE REPLACED. A/C RETURNED TO SERVICE. DAMAGE TO ONE ASPIRATOR CAUSED DURING PACKING. OTHER ASPIRATOR SHOWED IMPROPER ASSEMBLY OF ASPIRATOR'S JET PLATE DURING INITIAL FABRICATION.SDR SWAA070326Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AALA20070161Slide · unknownMIA - AFTER LANDING, CREW RECEIVED A LEFT WING SLIDE EICAS MESSAGE MOMENTARILY. REPLACED LEFT OVERWING SLIDE PACK ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR MWEA070006Slide · unsecureAFT GALLEY DOOR SLIDE PACK CAME UNFASTENED. REINSTALLED AFT GALLEY DOOR SLIDE.SDR AWXA200700111Slide · no testLAS - EE - EMERGENCY EXIT LIGHT TEST FAILED FOR LEFT AFT EXT LOAD FAULT (STEP 6 OF T/C I8M05334). MX REMOVED AND REPLACED AFT RT CABIN DOOR SLIDE ASSY PER T/C R1C25305. MX PERFORMED EMERG EXIT LIGHT TEST PER STEP 6 OF T/C I8M05334. OPS CHECK WAS GOOD.SDR SWAA070307Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070305Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070304Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070303Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 07FDEA00151Slide · lowR1 DOOR ESCAPE SLIDE PRESSURE INDICATOR NOT IN GREEN BAND REMOVED AND REPLACED R1 DOOR ESCAPE SLIDE IAW A310-300 AMM 25-61-22-4-01 AND A310 - 300 AMM 52-10-00-3.SDR 2007UALA00155Girt Bar · out of adjustL-2 CABIN DOOR, ARM HANDLE HARD TO ENGAGE. ADJUSTED GIRT BAR MECHANISM WHICH FIXED THE DISCREPANCY. NO COMPONENTS NEEDED TO BE REPLACED.SDR 2007UALA00150Light · no testEMERGENCY LIGHT TEST FAILED LEFT FWD DOOR SLIDE. FAULT READS EXT LOAD FWD LEFT. REPLACED DOOR 1L SLIDE PACK. EMERGENCY LIGHT TEST OK.SDR SWAA070301Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA00160Light · inoperativeFOUND EMERGENCY LIGHT INOP, DOOR 2R SLIDE ILLUMINATED. REPLACED EMERG LT ASSY. OP CHECKS OK.
Back to JASC 2565