Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200700007Girt Bar · corrodedDURING C-3 CHECK, INSPECTION REPORTED GIRT BAR PLATES ON FWD AND AFT L2 DOOR CORRODED. REPLACED FWD AND AFT L2 DOOR GIRT BAR PLATES PER AMM 52-13-31. RIGGED AND SEALED GIRT BAR LATCHES PER AMM 52-13-00-820-001.SDR SWAA070072Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA00062O-Ring · unserviceableLOW BOTTLE, LEAKING AROUND GAUGE O-RING. REPLACED O-RING. REPLACED SLIDE. A/C RETURNED TO SERVICE. ROOT CAUSE SUSPECTED TO BE GAUGE OVER TORQUED DURING INSTALLATION WITH RESULTING DAMAGE TO O-RING.SDR F3LA200700004Girt Bar · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION IN FWD GIRT BAR FITTING FASTENER HOLES ON L2 DOOR FRAME SILL. REMOVED CORROSION IAW SRM 53-41-14, FIG 101. FABRICATED REPAIR DOUBLER PER EA A9-54R-11722, STEP 5.SDR SWAA070060Slide · out of adjustDURING SCHEDULED 12Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA070059Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS07148834Lever · bindingMAIN ENTRANCE DOOR (CREW DOOR) SLIDE ARMING LEVER BINDS WHEN UNLOCKING, SEVERAL ATTEMPTS TO UNLOCK WERE NEEDED TO DISARM THE SLIDE. PERFORMED LUBRICATION ON THE SLIDE ARM/DISARM MECHANISM.SDR SWAA070044Slide · dislodgedR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SA07001Bottle · reads lowPHX - A CIDS WARNING WAS GENERATED ON THE FORWARD FLIGHT ATTENDANT'S PANEL FOR THE LEFT OVERWING SLIDE INFLATION BOTTLE. MAINTENANCE REPLACED THE LEFT OVERWING SLIDE INFLATION BOTTLE. OK FOR SERVICE.SDR ASAA0741352Slide · twistedDURING R1 DOOR SLIDE DEPLOY TEST THE SLIDE TWISTED UPON DEPLOYMENT. REPLACED R1 DOOR EVAC SLIDE.SDR 2007UALA00025O-Ring · leakingLOW BOTTLE PRESSURE. FOUND A LEAKING FUSIBLE PLUG O-RING. REPLACED O-RING.SDR UPS07148858Arming Lever · jammedCABIN DOOR SLIDE ARMING HANDLE JAMMING WHEN DISARMING. CHECKED DOOR SLIDE ARMING SYSTEM IAW MM 25-61-04. FOUND NO ABNORMALS.SDR AMTA200700004Proximity Switch · unknownSLIDE LIGHT OFF WITH BAR ENGAGED. REPLACED NR 4 LT DOOR AFT GIRT BAR PROX SWITCH IAW AMM 25-66-11-2. SLIDE LIGHT OPS CHECK NORMAL. (K)SDR 2007UALA00023Light · inoperativeDOOR 2L SLIDE ARMED LIGHT WILL NOT ILLUMINATE. REPLACED LAMP.SDR 2007UALA00018Slide · faultyEMERGENCY LIGHT TEST PER 3SV HAS FAULT, EXT LOADS FWD L FAULT. REPLACED DOOR 1R SLIDE.SDR SWAA070005Slide · unserviceableR1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA070002Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR USAASA07003Slide · faultyPHL - AFTER AN ACCIDENTAL SLIDE DEPLOYMENT OF THE L3 DOOR, THE SLIDE DID NOT RELEASE WHEN THE DITCH HANDLE WAS PULLED AND THE DOOR ASSIST BOTTLE DID NOT DISCHARGE DURING DOOR OPENING. MAINTENANCE REPLACED THE SLIDE AND THE DOOR ASSIST BOTTLE. OK FOR SERVICE.SDR 2007UALA00033Slide · unserviceableDOOR 1L PRESSURE BOTTLE OUT OF GREEN.SDR 2007UALA00024Bottle · lowDOOR 1L PRESSURE BOTTLE OUT OF THE GREEN. REPLACED DOOR 1L SLIDE.SDR 2006UALA02437Bottle · leakingLOW BOTTLE PRESSURE. BOTTLE LEAKING AROUND GLASS ON GAUGE. REPLACED GAUGESDR SWAA065113Slide · out of adjustDURING SCHEDULED MV2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ASAA0741356Slide · twistedDURING R1 DOOR SLIDE DEPLOY TEST THE SLIDE TWISTED UPON DEPLOYMENT. REPLACED R1 DOOR EVAC SLIDE.SDR 2006UALA02432Piston · unserviceableLOW BOTTLE PRESSURE. SLIDE REPLACED. A/C RETURNED TO SERVICE. BOTTLE LEAKING AROUND ONE OF THE O-RINGS ON PISTON. REPLACED O-RINGS ON PISTON. SUSPECT O-RING PINCHED DURING INSTALLATION.SDR 2006UALA02428O-Ring · unserviceableLOW BOTTLE PRESSURE. SLIDE REPLACED. A/C RETURNED TO SERVICE. BOTTLE LEAKING AROUND THE SHAFT. REPLACED WITH NEW SHAFT, BACK O-RING AND SHAFT O-RING. SUSPECT O-RING CRUSHED BY SIDE LOAD WHILE IN SERVICE.SDR SWAA065082Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA065080Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA065077Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR NOCA23106Slide · dischargedL-4 DOOR SLIDE NEEDLE IN RED. REMOVED AND REPLACED L-4 SLIDE PER MM 25-66-01, INFO RECORDED ON PL 755-0612-04. OPS CHECKS OKAY.SDR SWAA065035Hook · looseDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. SECURED GIRT BAR HOOK PER MM.SDR SWAA065034Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06M48796Slide · failedINSPECTION TYPE:N/A DURING TEST, FIRED THE TWO FORWARD EXIT DOOR SLIDES. WHEN DOOR 1R WAS FIRED, THE EMERGENCY PNEUMATIC BOTTLE FIRED ITS CONTENTS INTO THE AIR MOTOR (AS DESIGNED), BUT THE DRIVE CHAIN TO LIFT THE DOOR WAS NOT FITTED. REPLACED R1 DOOR AFT DRUSDR UPS06848791Slide · unwanted deployINSPECTION TYPE:N/A EMERGENCY ESCAPE SLIDE DEPLOYED INADVERTENTLY. DEFERRAL M340403 ASSIGNED. CLEARED MEL 52-7-4 M340403. INSPECTED AND REINSTALLED ORIGINAL DOOR SLIDE IAW AMM 25-60-01 & CHECKS OK.SDR SWAA065014Hook · looseDURING SCHEDULED 10Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. REMOVED AND REPLACED AFT GIRT BAR HOOK PER SRM.SDR SWAA065011Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA065010Hook · looseR1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. SECURED AFT GIRT BAR HOOK PER SRM.SDR SWAA065009Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064997Cable · misroutedDURING SCHEDULED C3 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA064992Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064991Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064990Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR UPS06148790Light · inoperativeINSPECTION TYPE:N/A DOOR SLIDE ARMING LIGHT INOP. INSPECT BATTERY PACK AND CONNECTOR. PERFORMED TEST PER MM 52-73-04 PARA D. OPS CHECK NORMAL. NO DEFECTS NOTED.SDR SWAA064985Slide · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA064984Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064983Slide · out of adjustDURING SCHEDULED 8Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06148779Girt Bar · bindingINSPECTION TYPE:N/A DOOR ARMING LEVER STIFF AND SEEMS TO BIND SLIGHTLY. CLEANED DEBRIS FROM GIRT BAR LATCHES. CHECKS GOOD.SDR 2006UALA02377Fitting · inoperativeFOUND MED 2L EMERGENCY SLIDE GIRT BAR AFT ATTACH POINT TO AC INOPERABLE, SPRING POSSIBLY BROKEN. REPLACED AFT FLOOR FITTING.SDR AALA20061270Slide · dislodgedAS PASSENGERS WERE DEPLANING CATERING OPENED RIGHT NUMBER TWO DOOR AND SLIDE FELL OUT OF PACK AND ON TO CATERING TRUCK. DOOR WAS DISARMED. SLIDE DID NOT DEPLOY. REPLACED SLIDE FOR RIGHT NUMBER TWO DOOR AT ORD ON 15 DEC 2006. SYSTEM GROUND CHECKED NORMAL OPESDR 2006UALA02375Cylinder · low pressureLOW PRESSURE ON CYLINDER. WATER BATHED FOR 1 HOUR AND FOUND NO LEAKS. REPLACED VALVE AND REBUILT VALVE.SDR SWAA064959Slide · out of adjustR2 DOOR EVACUATION SLIDE OUT OF POSITION. REPOSITIONED R2 DOOR SLIDE ASSY PER MM.
Back to JASC 2565