duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS06848782Slide · looseINSPECTION TYPE:N/A EMERGENCY ESCAPE SLIDE & GIRT BAR LOOSE AND CANISTER OPENED. REPLACED DAMAGED & MISSING ATTACHMENT HARDWARE, RESEALED CANISTER AND SECURED GIRT BAR.SDR UPS06148773Warning Light · inoperativeCREW REPORTS ON PREFLIGHT, EVAC. SLIDE WARNING LIGHT INOP, BUZZER OK. PERFORMED T/S. FOUND IND 7WN AT FAULT. PER ASM 52-73-00 SCHEM 02 PAGE 103. REMOVED CLEANED AND REINSTALLED CANNON PLUG ON ASPSU 7WN.SDR UPS06848768Slide · dislodgedEMERGENCY EXIT SLIDE COMING OUT OF BOX. REPACKED SLIDE IN BOX AND SECURED ON ENTRY DOOR.SDR USAASA06093Cylinder · faultyDCA - THE LEFT SIDE, OVERWING ESCAPE SLIDE BOTTLE CABLE CONNECTION WAS FOUND FAULTY. MAINTENANCE REPLACED THE LEFT SIDE, OVERWING ESCAPE SLIDE BOTTLE. OK FOR SERVICE.SDR USAASA06092Slide · malfunctionedDCA - THE RIGHT HAND, OVERWING EMERGENCY ESCAPE SLIDE WAS ACTIVATED, BUT DID NOT FULLY DEPLOY. MAINTENANCE REPLACED THE RIGHT HAND, OVERWING EMERGENCY ESCAPE SLIDE AND SLIDE BOTTLE. OK FOR SERVICE.SDR ABXA060315Cam · obstructedL1 DOOR SLIDE WOULD NOT ARM. FOUND A PIECE OF DOOR GUARD IN THE CAM AREA, REMOVED FOD. DOOR SLIDE ARMED AS REQUIRED IAW B767 MM.SDR AALA20071786Slide · dislodgedDEL - RIGHT NUMBER TWO EMERGENCY EXIT DOOR SLIDE FELL OUT OF PACK WHEN DOOR OPENED WITH HANDLE IN DISARM POSITION. DID NOT DEPLOY. REPLACED RIGHT NUMBER TWO EMERGENCY EXIT DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR SWAA064952Slide · dislodgedL1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE ASSY PER MM.SDR UPS06248764Slide · dislodgedESCAPE SLIDE FELL OUT OF HOUSING. REINSTALLED ESCAPE SLIDE.SDR UPS06848762Slide · brokenEMERGENCY ESCAPE SLIDE FELL OUT OF CONTAINER. SLIDE LANYARD TANG BROKEN. REMOVED AND REPLACED EVAC SLIDE CONTAINER IAW 25-60-01.SDR SWAA064884Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064890Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064881Fitting · looseDURING SCHEDULED 22Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING LOOSE. SECURED FITTING PER SRM.SDR SWAA064880Fitting · looseDURING SCHEDULED 22Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING LOOSE. SECURED FITTING PER SRM.SDR UPS06M48747Light · inoperativeLEFT CREW ENTRY DOOR SLIDE LIGHT DOES NOT TEST. REMOVED AND REPLACED EVAC SLIDE PRESS IND, PRESS TO TEST SWITCH AND BATTERY PACK. OPS CHECK GOOD.SDR SWAA064850Slide · dislodgedL2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA064858Slide · low pressureDURING SCHEDULED A1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA064856Cable · misroutedDURING SCHEDULED MV2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA064855Cable · misroutedDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR UPS06848741Slide · out of positionINSPECTION TYPE: PFLT DURING CREW PREFLIGHT EMERGENCY SLIDE BECAME DISLODGED FROM CONTAINER. REINSTALLED SLIDE.SDR 2006UALA02350Slide · underservicedDOOR 1 RIGHT SLIDE INSTALLATION. *S/D* DOOR 1 RT SLIDE INSTALLED ON PTT SEQUENCE NUMBER 5152004. NECESSARY TO RECHECK DOOR 1 RIGHT SLIDE FOR ELECTRICAL HARNESS ROUTING. REROUTED DOOR 1 RIGHT SLIDE ELECTRICAL HARNESS AND CONNECTED. SLIDE OPS TESTS GOOD.SDR UPS06148774Slide · will not armSLIDE WILL NOT ARM. FOUND BURR ON GIRT BAR, REMOVED BURR CLEANED; LUBED SLIDER. OPS CKS GOOD PER M/M 52-10-30-06. THIS CLEARS M339296.SDR 2006UALA02335Light · inoperativeSLIDE LIGHT ABOVE DR 1L INOP. LAMP WAS FUSED. REPLACED LAMP AND OPS CHECK NORMAL.SDR SWAA064838Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR USAASB06121Reflector · corrodedPHL - MAINTENANCE REPORTED THE LEFT FORWARD EXTERIOR EMERGENCY ESCAPE SLIDE LIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE REFLECTOR ASSEMBLY. OPERATIONAL CHECK GOOD.SDR SWAA064814Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064802Cable · misroutedDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA064742Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR A25005Slide · unwanted deployRT UPPER DECK ESCAPE SLIDE ACCIDENTALLY DEPLOYED DURING OPERATION OF THE DOOR.SDR A25005CGNSlide · unwanted deployRIGHT UPPER DECK ESCAPE SLIDE ACCIDENTALLY DEPLOYED DURING OPERATION OF THE DOOR.SDR SWAA064686Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2006UALA02305Slide · no testDOOR 1L EVACUATION SLIDE FAILED TO FULLY DEPLOY DURING SLIDE OPERATIONAL CHECK. DOOR 1L EVACUATION SLIDE FAILED TO FULLY DEPLOY DURING SLIDE OPERATIONAL CHECK. SLIDE SHIPPED TO SFO FOR EG EVALUATION. SUSPECT SLIDE PACKING PROBLEMS NEW SLIDE INSTALLED. A/CSDR 2006UALA02296Slide · unserviceablePASSENGER DOOR 2L ESCAPE SLIDE RAFT RELEASE STRAP NOT ROUTED THROUGH GIRT BAR. RELEASE STRAP AND SURVIVAL KIT LANYARD NOT VELCROED TO EACH OTHER. REPLACED 2L SLIDE-RAFT.SDR 2006UALA02298Slide · faultyTEST OF EMERGENCY LIGHTS FAILED WITH -EXT LOADS AFT L-. REPLACED AFT RIGHT SLIDE.SDR 2006UALA02295Slide · unserviceablePASSENGER DOOR 2R ESCAPE SLIDE RAFT RELEASE STRAP NOT ROUTED THROUGH GIRT BAR. RELEASE STRAP AND SURVIVAL KIT LANYARD NOT VELCROED TO EACH OTHER, MOORING LINE LOOSE IN GIRT AND NOT ATTACHED TO GIRT BAR, ELECTRICAL HARNESS LOOSE (NOT SECURED UNDER VELCRO) AND SDR 2006UALA02316O-Ring · damagedLOW BOTTLE. REPLACED BACKUP O-RING AND O-RING.SDR 2006UALA02297Bracket · brokenTHE 1 LT MED SLIDE PACK SUPPORT BRACKET BROKEN. REPLACED SLIDE PACK ASSEMBLY.SDR 2006UALA02294Slide · unserviceablePASSENGER DOOR 1L ESCAPE SLIDE RAFT RELEASE STRAP NOT ROUTED THROUGH GIRT BAR. RELEASE STRAP AND SURVIVAL KIT LANYARD NOT VELCROED TOGETHER, PARACHUTE PIN NOT SECURED WITH NYLON THREAD (IT IS SECURED WITH A LACING CORD WHICH LOOKS LIKE IT WILL NOT BREAK EASILSDR 2006UALA02289Sensor · faultyDOOR 4 RIGHT ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT STAYS ON WITH DOOR DISARMED. CLEANED SENSOR AND REROUTE WIRE. LIGHTS OFF WITH DOOR DISARM.SDR SWAA064641Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2006UALA02286Slide · unwanted deployCREW REPORTED DOOR 2R SLIDE BLOWN. REPLACED DOOR 2R SLIDE.SDR 2006UALA02285Slide · faultyEMERGENCY LIGHT TEST FAULTS EXT LOADS FWD LEFT. UNBOLTED SLIDE, CLEANED CONNECTOR, REINSTALLED SLIDE. TEST PASSED.SDR UPS06248725Slide · out of positionINSPECTION TYPE: N/A MAIN ENTRY DOOR ESCAPE SLIDE FALLS OUT OF ITS CONTAINER WHEN DOOR IS MOVED. FOUND COMPARTMENTAL COVER LATCH CABLE DISCONNECTED. REPAIRED IAW 25-60-14-2. OPS CK GOOD.SDR SWAA064604Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064602Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2006UALA02284Slide · mismanufacturedNR 2 RIGHT MED SLIDE CAME IN WITHOUT THE POWER CABLE HOOKED UP. ELECTRICAL POWER CABLE CONNECTED.SDR 2006UALA02283Bracket · brokenFWD RIGHT MED EMERGENCY SLIDE PACK DOOR SUPPORT BRACKET BROKEN. REPLACED FORWARD RT DOOR SLIDE.SDR 2006UALA02256O-Ring · leakingLOW BOTTLE PRESSURE. *S/D* LEAKAGE FOUND THROUGH GAUGE BACKUP O-RING AND THE SECOND O-RING. REPLACED BACKUP O-RING & SECOND O-RING.SDR SWAA064554Cable · frayedDURING SCHEDULED 12Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED EVAC SLIDE CABLE PER MM.SDR SWAA064551Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.
Back to JASC 2565