Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA064249Girt Bar · crackedDURING SCHEDULED 12Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CRACKED. REMOVED AND REPLACED GIRT BAR FITTING PER MM.SDR SWAA064237Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR F3LA200600151Bottle · brokenDURING C-3 CHECK, INSPECTION REPORTED RT. OVERWING RESERVOIR INFLATION CABLE IN AFT PIT HAD TIP BROKEN OFF THAT HOOKS TO THE FLEX RELEASE CABLE. REPLACED OVERWING SLIDE BOTTLE IN RT AFT PIT IAW AMM 25-62-46-400-001.SDR UPS06848493Indicator · out of positionESCAPE SLIDE PRESSURE GAUGE CAN NOT BE SEEN. REPACKED CHUTE. CK'S OK.SDR UPS06148441Warning Light · inoperativeEVACUATION SLIDE WARNING LIGHT INOP. RELAMPED EVACUATION SLIDE WARNING LIGHT. DEFERRED SAME UNDER MEL 52-73-01-1. TRANSFERED TO DMI LOG UNDER M336982. RESET CONNECTOR 70 WN-A ON THE AUTONOMOUS STANDBY POWER SUPPLY PER AMM 52-73-01. NOTE: AMB 3-52-05-004. TSDR WRLA2006101Slide · no testDURING 4C CHECK IN TPE, L4 DOOR SLIDE DEPLOYMENT FAILED DURING TESTING. REMOVED AND REPLACED SLIDE PER AMMSDR 2006UALA02123Gauge · dislodgedLT AFT MAIN ENTRY DOOR EVACUATION ESCAPE SLIDE GAUGE DISLODGED AND OUT OF VIEW CAN NOT VERIFY BOTTLE PRESSURE UNLESS COVERING IS REMOVED. REPLACED WITH SERVICEABLE EVACUATION ESCAPE SLIDE.SDR 2006UALA02109Aspirator · leakingASPIRATOR LEAKING BETWEEN HOUSING ASSEMBLY AND NAME PLATE. REPLACED EVAC SLIDE. RETURNED TO SERVICE.SDR UPS06848400Indicator · obstructedESCAPE SLIDE GAUGE UNREADABLE. DEFERRED M336910. REMOVED & REPLACED CONTAINER COVER ASSY. REINSTALLED LIFE RAFT W/REF TO MM 25-60-01-2. OPS CK NORMAL. THIS CLEARS M336910.SDR SWAA064188Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064187Hook · looseDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED FWD GIRT BAR HOOK PER MM.SDR SWAA064182Hook · looseDURING SCHEDULED 18Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED FWD GIRT BAR HOOK PER SRM.SDR SWAA064181Hook · looseDURING SCHEDULED 18Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. SECURED AFT GIRT BAR HOOK PER SRM.SDR SWAA064180Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064179Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA02104Valve · unserviceableLOW BOTTLE PRESSURE. *S/D* FILL VALVE WAS LEAKING. REPLACED WITH A NEW FILL VALVE.SDR 2006UALA02113Girt Bar · damagedDOOR 1L SLIDE GIRT BAR HUNG UP ON DOOR FRAME AND CAME APART ON ARRIVAL. REPLACE DOOR 1L FWD GIRT BAR LIFTER ACCT FOUND BROKEN AT ARRIVAL. REMOVED AND REPLACED FWD GIRT BAR LIFTER AND TESTED NORMALSDR 2006UALA02112Bar · brokenLT OVER WING SLIDE TENSION BAR HOLD-DOWNS BROKEN. LT OVER WING SLIDE TENSION BAR HOLD-DOWNS BROKEN. (NYLON HOOKS) REPLACED SLIDE . RETURNED TO SERVICE.SDR SWAA064175Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064173Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA02097Aspirator · leakingASPIRATOR LEAKING BETWEEN SENSING TUBE AND BARREL. SLIDE REPLACED. RETURNED TO SERVICE AFTER VISIT.SDR 2006UALA02103Indicator · failedSLIDE LIGHT INOP DOOR 1R. CHECKED GIRT BAR SWITCH AREA TO BE FREE OF DEBRIS AND THAT SWITCHES ARE SECURE. THE ROOT CAUSE LIES IN A BLOWN LT SLIDE LIGHT INDICATOR ASSY. REPLACED SLIDE LIGHT ASSY.SDR 2006UALA02100Lanyard · misroutedREROUTE SURVIVAL KIT LANYARD ON DOOR 2L SLIDE RAFT. REROUTED LANYARD.SDR UPS06M48371Light · inoperativeLEFT SLIDE INFLATION CYLINDER LOW PRESSURE SWITCH LIGHT WILL NOT TEST TIGHTENED BAYONET CONNECTOR. DLS NORMAL WHEN PRESS TO TEST.SDR SWAA064163Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064162Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064161Cable · misroutedDURING SCHEDULED A2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR 2006UALA02098Cable · unsecureDURING ACP OF EQ5495 FOUND SLIDE BALL END CABLES UNSECURED AND IMPROPERLY PACKED. *S/D* REPLACED SLIDE ASSEMBLY. AIRCRAFT RETURNED TO SERVICE.SDR SWAA064153Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR NOCA18106Slide · unwanted deployF/A DEPLOYED DOOR L4 SLIDE BY ACCIDENT, SLIDE STARTED TO UNRAVEL BUT BOTTLE DID NOT BLOW. REMOVED AND REPLACED DOOR L4 SLIDE ASSY PER MM 25-66-01. REMOVED AND REPLACED DOOR L4 DOOR ASSIST BOTTLE PER MM 52-11-30, OPS CHECKS NORMAL.SDR AWXA200601844Slide · no testPHX - EES - EMERGENCY LIGHTS TEST FAILED, EXTERNAL LIGHTS FAULT. REPLACED R1 AND L1 DOOR SLIDES IAW TASK CARD M1C25301. OPS CHECK WAS GOOD. SLIDE, ESCAPE FWD R1.SDR SWAA064149Fitting · corrodedDURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER MM.SDR UPS06M48356Light · weakL1 DOOR ESCAPE SLIDE/RAFT REMOTE PRESS INDICATOR LIGHT VERY DIM. REPLACED LOW PRESS INDICATION SYSTEM BATTERIES. TESTED IAW 25-61-04- 5.SDR UPS06848359Slide · dislodgedESCAPE SLIDE FELL OUT OF CABIN EXIT DOOR. REINSTALLED ESCAPE SLIDE PER DC8 AMM REF 25-60-01-2.SDR 2006UALA02086Valve · unserviceableLOW BOTTLE PRESSURE. FILL VALVE INTERNAL PARTS FAULTY. REPLACED WITH NEW FILL VALVE. SDR 2006UALA1986 IS THE ORIGINAL GRIP FOR THIS SLIDE.SDR 2006UALA02085Valve · unserviceableLOW BOTTLE PRESSURE. SHOP FINDINGS: LEAKING AROUND FILL VALVE O-RING. REPLACED FILTER VALVE AND FILL VALVE O-RING.SDR YENA200684Girt Bar · failedON C4.01 CHECK. WHILE PERFORMING JOB CARD 521000-04-1 POSITION 841 TASK CARD. THE TELESCOPING END OF THE GIRT BAR DOES NOT DECREASE IN LENGTH WHEN THE TRIGGER IS PUSHED AT PASSENGER/CREW DOOR. REPLACED GIRT BAR AT PASSENGER/CREW DOOR 841 IAW AMM 25-62-44 PASDR SWAA064123Fitting · looseDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING LOOSE. SECURED GIRT BAR FITTING PER MM.SDR SWAA064121Bracket · looseR2 DOOR EVACUATION SLIDE GIRT BAR STOW HOOK BRACKETS LOOSE. SECURED BRACKETS PER MM.SDR ASAA0681140Slide · failedDURING CATERING, THE L 2 DOOR SLIDE PACK FELL OUT OF SLIDE CASE AND WOULD NOT DEPLOY. FOR MORE INFO NEED TO NOTIFY INFLT SERVICE FOR DETAILS. CLARIFICATION OF CIRCUMSTANCES SURROUNDING THIS INCIDENT HAS BEEN REQUESTED FROM LINE MAINTENANCE AND IT IS INTENDEDSDR SWAA064107Girt Bar · looseDURING SCHEDULED 22Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED FWD GIRT BAR HOOK PER SRM.SDR SWAA064098Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06M48325Switch · inoperativeL1 DOOR SLIDE SWITCH INOP DEFERRED PER MEL 25-61-2. DMP 25-61-2. C/W DOOR SLIDE BOTTLE PRESSURE. VERIFIED IN THE GREEN BAND PRIOR TO DEP FROM PVG. PLACARD INSTALLED. RELAMPED. OPS CHECK GOOD IAW 33-00-00. PLACARD FOR M336276 REMOVED.SDR 2006UALA02047Adapter · unserviceableLOW PRESSURE CYLINDER. PRESSURE GAUGE ADAPTER THREADS FOUND LEAKING. REPLACED PRESSURE GAUGE ADAPTER.SDR 2006UALA02084Valve · unserviceableLOW BOTTLE PRESSURE.SDR 2006UALA02046Valve · unserviceableLOW BOTTLE PRESSURE. A ONE-HOUR WATER BATH TEST WAS DONE TO THE VALVE AND IT DID NOT SHOW ANY LEAKS. VALVE WAS DISMANTLED AND ALL O-RINGS WERE IN GOOD CONDITION, NO EVIDENCE OF CAUSE. REPLACED VALVE AND BOTTLE.SDR AMTA200600626Slide · dislodgedON DOOR OPENING IN HNL 1L SLIDE CAME OUT OF ITS CASE. REINSTALLED SLIDE PER MM 25-66-01-4. OPS CHECK NORMAL. (M)SDR 2006UALA02044Girt Bar · defectiveDEFECTIVE GIRT BAR.SDR SWAA064080Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064078Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.
Back to JASC 2565