Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA060300Slide · malfunctionedEMERGENCY ESCAPE SLIDE WOULD NOT ARM. CHECKED RAILS AND HANDLE FOR OBSTRUCTIONS, NONE FOUND. OPERATED DOOR AND SLIDE, OPS CHECKED GOOD.SDR SWAA064542Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR XXUA20061135Slide Raft · reads lowDURING DAILY SERVICE CHECK, FOUND L2 DOOR SLIDE PRESSURE LOW. REMOVED AND REPLACED DOOR SLIDE AS PER MM 25-66-01.SDR SA06088Bottle · dischargedDEN - WHILE AT THE GATE, A -CIDS- CAUTION LIGHT CAME ON. MAINTENANCE PERFORMED A BITE CHECK OF THE CIDS SYSTEM AND DETERMINED THAT THE LEFT, OVERWING, EMERGENCY EXIT SLIDE BOTTLE INDICATED IN THE RED BAND. THE AIRCRAFT WAS MAINTENANCE FERRIED TO PHL AND THE SDR 2006UALA02253O-Ring · leakingLOW BOTTLE PRESSURE GAUGE O-RING AND PACKING BACK LEAKING. REPLACED O-RING AND PACK IN BACKING.SDR 2006UALA02282Girt Bar · misinstalledLEFT NR 2 ENTRY DOOR SLIDE GIRT BAR INSTALL REVERSED. REMOVED SLIDE ASSY, GIRT BAR AND REINSTALLED. APPEARS TO BE INSTALLATION ERROR.SDR 2006UALA02254O-Ring · leakingLOW BOTTLE PRESSURE. SLIDE REPLACED, A/C RETURNED TO SERVICE. FILL VALVE O-RING LEAKING. REPLACED FILL VALVE O-RING.SDR 2006UALA02238Slide · unwanted deployAIRCRAFT ARRIVED FOR C-CHECK MAINTENANCE AND IT WAS FOUND TO HAVE THE RT OVERWING SLIDE PARTIALLY DEPLOYED. SLIDE STILL IN COMPARTMENT. SLIDE REPLACED.SDR SWAA064515Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06M48711Light · inoperativeINSPECTION TYPE:N/A L1 DOOR SLIDE ARMING LIGHT INOP. REPLACED BATTERY & REPLACED LIGHT BULBS. OPS TESTED, WORKING FINE. DEFERRAL CLOSED AND PLACARD REMOVED.SDR 2006UALA02227Aspirator · unserviceableBAD ASPIRATOR. CAUSE UNKNOWN. REPLACED ASPIRATOR. THIS WAS BETWEEN SENSING TUBE AND JET PLATE ASSEMBLY.SDR SWAA064481Latch · looseL1 DOOR EVACUATION SLIDE GIRT BAR LATCH ROLL PIN LOOSE. REMOVED AND REPLACED GIRT BAR LATCH ASSY.SDR SWAA064496Slide · looseR1 DOOR EVACUATION SLIDE LOOSE. REPOSITIONED SLIDE ASSY PER MM.SDR SWAA064475Slide · dislodgedL1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE ASSY PER MM.SDR NOCA20306Bulb · inoperativeR-4 DOOR SLIDE INDICATOR LIGHT INOP. RELAMPED R-4 DOOR SLIDE INDICATOR LIGHT. OPS CHECKS NORMAL, SYSTEM CHECKS NORMAL AS PER AMM 25-66-01.SDR 2006UALA02207Slide · reads lowDOOR 2L SLIDE PRESSURE LOW. DOOR 2L SLIDE PRESS LOW. REPLACED NR 2L SLIDE RAFT.SDR USAASA06085Girt Bar · faultedPHL - THE L4 DOOR EMERGENCY ESCAPE SLIDE GIRT BAR ARMED INDICATOR WAS FOUND BROKEN DURING REPLACEMENT OF THE SLIDE. MAINTENANCE REPLACED THE EMERGENCY ESCAPE SLIDE GIRT BAR. OK FOR SERVICE.SDR 2006UALA02202O-Ring · leakingLOW BOTTLE PRESSURE. FUSIBLE PLUG O-RING LEAKING. REPLACED O-RING.SDR 2006UALA02203Aspirator · leakingSLIDE ASPIRATOR LEAKING.SDR 2006UALA02200Aspirator · unserviceableDAMAGED SLIDE ASPIRATOR. REPLACED SLIDE. OK FOR RETURN TO SERVICE.SDR 2006UALA02196Cover · dislodgedSLIDE COVER AT 2L COMES OFF. REPLACED 2 LEFT SLIDE RAFT.SDR SA06083Girt Bar · malfunctionedPHL - THE RETAINING BAR CLIP FOR THE MAIN CABIN DOOR SLIDE DID NOT APPEAR TO WORK PROPERLY. MAINTENANCE FOUND THE RETAINING BAR CLIP STICKING. THE SPRING WAS INPSECTED OK. CLEANED AND LUBED THE CLIP AREA. THE RETAINING BAR CLIP FUNCTIONALLY CHECKS OK.SDR 2006UALA02180Regulator · leakingLOW BOTTLE REGULATOR ASSEMBLY LEAKING FROM INSIDE. REPLACED WITH NEW REGULATOR. REPLACED SLIDE. RETURNED TO SERVICE.SDR SWAA064372Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064369Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064368Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064362Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007FA0000756Life Raft · partial inflateTHE LIFE RAFT VACUUM BAG INFLATED DUE TO CYLINDER LEAKAGE BETWEEN THE CYLINDER HEAD AND LIFE RAFT CYLINDER. THE AC WAS CRUISING AT 40,000 FT WHEN THE PILOT HEAR A LOUD POP. UPON INVESTIGATION, THE PILOT HAD DISCOVERED THE LIFE RAFT HAD AN UNCOMMANDED INFLATISDR SWAA064359Slide · low pressureDURING SCHEDULED A1 CHECK, L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 06FDEA03974Lanyard · disconnectedCABIN: SLIDE/RAFT AT R1 DOOR FOUND FIRING LANYAND DISCONNECTED WITH QUICK-DISCONNECT WHEN DOOR INTERIOR LWR COVER REMOVED FOR REPAIR. RECONNECTED R1 DOOR SLIDE/RAFT FIRING LANYAND AS PER AMM 25-61-06-4.SDR 06FDEA03973Lanyard · disconnectedCABIN: SLIDE/RAFT AT L1 DOOR FOUND FIRING LANYAND DISCONNECTED WITH QUICK-DISCONNECT WHEN DOOR INTERIOR LWR COVER REMOVED FOR REPAIR. RECONNECTED L1 DOOR SLIDE/RAFT FIRING LANYAND AS PER AMM 25-61-06-4.SDR SWAA064347Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA02174Light · faultyEMERGENCY LIGHT TEST FAULTING EXT LOAD FAULT EMERGENCY LIGHT. REPLACED SLIDE. REPLACED EPSU. EMERGENCY RIGHT OPS CHECKS OK.SDR SWAA064339Hook · looseDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. REMOVED AND REPLACED FWD GIRT BAR HOOK PER MM.SDR SWAA064338Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064326Slide · out of adjustDURING SCHEDULED SPV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064315Mount · corrodedDURING SCHEDULED 18Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR MOUNT CORRODED. REMOVED AND REPLACED AFT GIRT BAR MOUNT PER SRM.SDR 2006UALA02181Slide · inoperativeLEFT OVERWING SLIDE SYSTEM INOPERATIVE.SDR 2006UALA02163Bearing · damagedBEARINGS DAMAGED. REPLACED SLIDE. OK FOR RETURN TO SERVICE.TOO MUCH TENSION ON TENSION ROD OF SLIDE, CAUSING BEARINGS TO DETERIORATE AND CRACK OVER TIME. REPLACED BEARINGS.SDR 0602393303Slide · faultyDURING TEST OF THE EMERGENCY LIGHT SYSTEM THE ESCAPE SLIDE LIGHT DOOR NR 4 RIGHT FAULTED. REMOVED AND REPLACED ESPU AND DID NOT FIX THE FAULT. REMOVED AND REPLACED ESCAPE SLIDE AND TESTED OK.SDR SWAA064277Slide · out of positionEVAC SLIDES OUT OF POSITION. REPOSITIONED EVAC SLIDES PER MM.SDR SWAA064275Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR NOCA19006Hose · kinkedLEFT HAND OVERWING SLIDE HAS KINKED HOSE. REMOVED AND REPLACED HOSE ASSY.SDR SWAA064272Girt Bar · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED AFT GIRT BAR FITTING PER SRM.SDR SWAA064271Girt Bar · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED FWD GIRT BAR FITTING PER SRM.SDR SWAA064264Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA064262Slide · out of adjustDURING SCHEDULED PAE CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06248513Slide · dislodgedFOUND DOOR SLIDE ON FLOOR. RE-INSTALLED ESCAPE SLIDE PER 25-60-14-2.SDR 2006UALA02155Bottle · lowFOUND LOW BOTTLE PRESSURE. REPLACED SLIDE. AIRCRAFT RETURNED TO SERVICE.SDR F3LA200600158Cable · brokenDURING C-3 CHECK, INSPECTION REPORTED RT EMERGENCY EXIT SLIDE INFLATION CABLE BROKEN. REPLACED RESERVOIR IAW AMM 25-62-46.
Back to JASC 2565