Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA043541Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED R1 DOOR EVAC SLIDE PER MM.SDR SWAA043532Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA043538Hook · corrodedDURING SCHEDULED 1/2D CHECK, FOUND L1 DOOR EVAC SLIDE GIRT BAR AFT HOOK, CORRODED. REMOVED AND REPLACED GIRT BAR HOOK PER MM.SDR 2004UALA01188O-Ring · leaking90 DEGREE ELBOW TUBE ASSEMBLY LEADING WHERE FITTING GOES ON TO THE REGULATOR VALVE AS O-RING. DATA THE SDR DESCRIBES AN AIR LEAK AT THE INTERFACE BETWEEN THE SLIDE BOTTLE REGULATOR ASSEMBLY AND THE 90 DEGREE ELBOW TUBE LEADING TO THE PRESSURE GUAGE. REPLACEDSDR 2004UALA01185Slide · deployedSLIDE RECEIVED DEPLOYED. LWR LT SIDE INFLATION CHAMBER BLOWN OUT GREATER THAN 36 INCHES LONG. SLIDE RECEIVED IN SHIPPING CRATE W/O PACKBOARD OR VALISE COVER. SLIDE WAS INADVERTANTLY DEPLOYED. FINDINGS METER INDICATED SLIDE DEPLOYMENT WAS NORMAL AND SLIDE WSDR SWAA043519Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R1 AND R2 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED R1 AND R2 DOOR EVAC SLIDES PER MM.SDR SWAA043518Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR SWAA043517Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA043516Hook · looseDURING SCHEDULED C2 CHECK, FOUND L1 DOOR EVAC SLIDE GIRT BAR FWD HOOK LOOSE. REMOVED AND REPLACED L1 DOOR FWD HOOK PER SRM.SDR SWAA043515Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA043514Hook · shearedDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EVAC SLIDE AFT GIRT BAR HOOK RIVET SHEARED. REMOVED AND REPLACED L1 DOOR AFT GIRT BAR HOOK RIVET PER SRM.SDR 04UALA01181Slide · unserviceableDURING OVERHAUL OF DOOR TWO LEFT SLIDE THE MOORING LINE WAS FOUND TO BE PACKED IN BETWEEN GIRT HALVES. THE INFLATION CABLE WAS NOT RUN IN CABLE GUIDE BUT RUN THROUGH LACING GROMMET INSTEAD, THE SLIDE WAS FOLDED INSTEAD OF ROLLED AND WAS PACKED OVER BOTTLE ANSDR 2004UALA01182Slide · tornDEPLOYED SLIDE, FOUND TEAR IN FLOOR. SLIDE LEAKS IN INFLATABLE AND AT ASPIRATOR FLAPS. SLIDE SENT TO OEM (GOODRICH) FOR REPAIR. REPLACED GIRT AND ASPIRATOR.SDR 2004UALA01181Bulb · burned out6 BULBS BURNED OUT. MOORING LINE NOT IN POCKET, PLACED IN BETWEEN GIRT HALVES. HOSE WAS TAPED OVER SWIVEL 6 INCES FROM MAT DOWN HOSE. INFLATION CABLE NOT RUN IN CABLE GUIDE AND RAN THROUGH LACING GROMMET, THEREFORE SLIDE WOULD NOT HAVE FIRED, WAS 10 INCHES SDR 2004UALA01180Line · out of positionMOORING LINE LOOP UNDER LOWER LACING COVER. SLIDE REPACKED WITH MOORING LINE LOOP INSTALLED ON TOP OF LACING.SDR SWAA043508Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR SWAA043507Slide · out of adjustDURING SCHEDULED MV1 CHECK, FOUND L2 DOOR EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED L2 DOOR EVAC SLIDE PER MM.SDR SWAA043504Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND L1 DOOR EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED AFT GIRT BAR FITTING PER SRM.SDR 2004UALA01177Light · damagedDURING OVERHAUL EMERGENCY EXIT SLIDE LIGHT WERE FOUND TO BE DAMAGED. SUPPLEMENTAL DATA UPDATE THE LIGHT ASSEMBLY WAS REPLACED.SDR GTIA040861Slide · failedFTW - FOUND L1 DOOR SLIDE FAILED TO DEPLOY. REPLACED L1 DOOR SLIDE. (M)SDR 2004UALA01179Slide · oversizedSLIDE TOO LARGE, AS MEASURED WITH TEMPLATE. SLIDE WAS PACKED INCORRECTLY AT OVERHAUL. WHEN SLIDE INSTALLATION WAS ATTEMPTED, IT WAS REJECTED DUE TO BEING OVERSIZE. SLIDE WAS NOT INSTALLED ON A/C. SLIDE WAS REPACKED PER AIR CRUISER CMM 25-66-01 AND MADE SERSDR 2004UALA01176Packboard · crackedPACKBOARD CRACKED IN 2 PLACES. SLIDE/RAFT WAS REMOVED FROM AIRCRAFT AT NORMAL MAINTENANCE INTERVAL. PACKBOARD CRACKS WERE OBSERVED DURING SLIDE/RAFT OVERHAUL. CRACKS WERE MINOR AND WOULD NOT HAVE AFFECTED PERFORMANCE OF THE SLIDE/RAFT. IT IS POSSIBLE CRACKSDR 2004UALA01175Aspirator · damagedASPIRATOR HAS DAMAGED FLAPPER VALVE. FAILED AIR RETENTION TEST DUE TO LEAKING OF VALVE. SUPPLEMENTAL DATA UPDATE SLIDE/RAFT WAS REMOVED FROM AIRCRAFT AT NORMAL MAINTENANCE INTERVAL. DISCREPANT ASPIRATOR WAS OBSERVED DURING SLIDE/RAFT OVERHAUL AIR RETENTION SDR SWAA043487Slide · out of adjustDURING SCHEDULED RON, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR SWAA043499Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR 2004UALA01169Fitting · stuckDOOR 1L AFT GIRT BAR ATTACH FITTING IS STUCK OPEN AND WILL NOT SPRING BACK TO CLOSED OR LOCKED POSITION. REMOVED DEBRIS TRAPPED IN THE INTERFACE AND LUBED GIRT BAR.SDR SWAA043471Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR AWXA200401353Slide · delaminatedPHX - EES - DURING 4-DAY CHECK THE LOWER AFT CORNER OF THE RT OVERWING SLIDE WAS FOUND DELAMINATED. MAINTENANCE REMOVED AND REPLACED THE RT OVERWING SLIDE ASSEMBLY IAW T/C R1A25301.SDR EM04023Girt Bar · detachedFLIGHT 1625, DFW TO PIT - LEFT PASSENGER DOOR GIRT BAR OUT OF CLIPS, UNABLE TO CLOSE DOOR. THE EMERGENCY SLIDE DID NOT DEPLOY. MAINTENANCE, REATTACHED GIRT BAR AND PERFORMED OPERATIONAL CHECK OF THE DOOR.SDR SWAA043454Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR UPS04143553Warning System · false activationEVACUATION SLIDE WARNINIG SYSTEM RED LIGHT INOP ASSOCIATED WARNING BUZZER. RESET C/B (SLIDE ARM AND WARNING) LIGHT, OPS CK GOOD THIS CLEARS M292019 PLACARD REMOVED.SDR AWXA200401341Slide · faultyPHX - EEL / EES - FLT 0005 - DURING FLIGHT, EMERGENCY ESCAPE PATH LIGHTS AT SEAT ROWS 13, 17, 19, AND 24 ILLUMINATED. MAINTENANCE REMOVED AND REPLACED THE L-2 DOOR SLIDE ASSEMBLY IAW T/C R1C25304, OPERATIONAL CHECK OF EMERGENCY LIGHTING AND SLIDE WAS GOOD.SDR SWAA043446Cable · misroutedDURING SCHEDULED SERVICE CHECK, FOUND L2 DOOR EVAC SLIDE GIRT BAR CABLE MISROUTED. REROUTED CABLE PER MM.SDR 0402129760Strap · missingA LINE CHECK INSPECTION FOUND THE AFT EVACUATION SLIDE MISSING THE DEPLOYMENT STRAPS. MAINTENANCE INSTALLED THE STRAPS PER ROUTINE WORK CARD 2560-4064M, STEP 3G, RII INSPECTION REQUIRED AND COMPLIED WITH. AIRCRAFT RETURNED TO SERVICE.SDR MALA040848Girt Bar · corrodedDURING C-CHECK INSPECTION IN YYC, FWD SERVICE DOOR GIRT BAR FITTINGS & FLOOR SUPPORT PLATE FROM FRAME 15-18 IS CORRODED. MAINTENANCE REPLACED FITTINGS & SILL PLATES IAW SRM 51-42-00, 51-43-00, 51-23-00. AIRCRAFT RETURNED TO SERVICE 11/23/04.SDR UPS04843540Slide · deployedMAIN CABIN EXIT EMERGENCY SLIDE DEPLOYED. REPLACED SLIDE IAW 25-60-00 SECURITY CK GOOD, THIS CLEARS M291801.SDR SWAA043432Hook · looseDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EVACUATION SLIDE GIRT BAR STOW HOOK LOOSE. SECURED GIRT BAR STOW HOOK PER MM.SDR SWAA043431Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EVACUATION SLIDE OUT OF ADJUST. RE-ADJUSTED SLIDE ASSY PER MM.SDR SWAA043424Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EVACUATION SLIDE OUT OF ADJUST. RE-ADJUSTED SLIDE ASSY PER MM.SDR P9RA20040050Slide · deployedAFTER PUSH BACK IN CCS. GROUND CREW REPORTED DEBRIS UNDER R1 DOOR AND REQUESTED CREW TO OPEN THE DOOR. CREW MEMBER FAILED TO DISARM THE DOOR CAUSING THE SLIDE TO INFLATE. SLIDE REPLACED PER MM.SDR SWAA043423Clip · looseDURING SCHEDULED 1/4D CHECK, FOUND L1 DOOR EVACUATION SLIDE GIRT BAR STOW HOOK CLIPS LOOSE. SECURED STOW HOOK CLIPS PER MM.SDR SWAA043418Cable · misroutedDURING SCHEDULED SERVICE CHECK, FOUND BOTH AFT DOOR EVACUATION SLIDE RELEASE CABLES MISROUTED. REROUTED CABLES PER MM.SDR SWAA043417Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R1 DOOR EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA043612Hook · looseDURING SPV, FOUND R1 DOOR EVAC SLIDE GIRT BAR AFT HOOK LOOSE. REMOVED AND REPLACED R1 DOOR EVAC SLIDE GIRT HOOK FASTENER PER MM.SDR AWXA200401307Slide · leakingDURING INSPECTION FOUND R-2 DOOR SLIDE PRESSURE LOW. MX R/R R-2 DOOR SLIDE IAW T/C R1C25001. CONFIRMED REASON FOR REMOVAL FINDING RESERVOIR ASSEMBLY LEAKING AT THE RUPTURE DISC. REPLACED RUPTURE DISC AND RE-SERVICED RESERVOIR, LEAK CHECK GOOD PER CMM.SDR SWAA043400Bracket · corrodedDURING SCHEDULED 1/2D CHECK, FOUND BOTH L1 DOOR EVACUATION SLIDE GIRT BAR FLOOR ATTACH BRACKETS CORRODED. REMOVED AND REPLACED BRACKETS PER SRM.SDR SWAA043398Slide · looseDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EVACUATION SLIDE OUT OF ADJUST. RE-ADJUSTED SLIDE PER MM.SDR SWAA043396Slide · looseL1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR SWAA043394Slide · looseR1 DOOR EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE ASSY PER MM.SDR SWAA043388Slide · looseR1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.
Back to JASC 2565