Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA043713Hook · looseDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EVACUATION SLIDE GIRT BAR AFT STOW CLIP HOOK LOOSE. INSTALLED CLIP HOOK FASTENER PER MM.SDR SWAA043712Slide · out of adjustR1 DOOR EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR SWAA043711Slide · out of adjustL1 DOOR EVACUATION SLIDE OUT OF ADJUST. REINSTALLED SLIDE ASSY PER MM.SDR CA041222018Actuator · mismanufactured(CAN) SLIDE ACTUATOR MANUFACTURED TO INCORRECT LIMITS. SLIDE ACTUATOR WILL NOT FIT ONTO BETA SWITCH BRACKET P/N C6E1060-3. GROOVE FOR SLIDE ON A C6E1017-29 IS .1300 +/- .0005. GROOVE ON SLIDE FROM J.A.S. PDM C6E1017-29 IS .1200 +/- .0005. TRACK ON BETA SWITCHSDR 2004UALA01246O-Ring · leakingLOW BOTTLE PRESSURE. PRESSURE LEAKING AT SHAFT O-RING. REPLACED SHAFT O-RING, BACK-UP O-RING, BALL SEAT, GAGE ADPATER O-RING.SDR AALA20041244Girt Bar · misinstalledDFW - FOUND RIGHT NR 2 SLIDE GIRT BAR INSTALLED UPSIDE DOWN. REPLACED SLIDE FOR RIGHT NUMBER 2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR SWAA043706Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR SWAA043701Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA043700Slide · out of adjustDURING SCHEDULED C2CHECK, FOUND R2 AND L2 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED R2 AND L2 DOOR EVAC SLIDES PER MM.SDR 2004UALA01241Slide · leakingON LOWER TUBE, BOTH SUPPORT LEGS AT THE FRONT END ON UPPER SIDE, OPPOSITE ASPIRATOR, LEAKING. LEAKING ON MITERED CORNER AT BUMPER TUBE ON ASPIRATOR SIDE IN FRONT. SLIDE FAILED AIR RETENTION TEST. LEAKAGE WAS FOUND AT SEAMS. POROSITY WAS FOUND NEAR SEAMS. SDR 2004UALA01238Aspirator · damagedLOWER CHAMBER ASPIRATOR (60322-105) CRUSHED AND RENDERED UNREPAIRABLE. PACKBOARD DAMAGED AT BOTH OUTBOARD CORNERS AND BOTTOM SHAFT SUPPORTS DAMAGED FROM SERVICE HANDLING. ASPIRATORS APPEAR DAMAGED FROM LAST PACKING. REPLACED THE ASPIRATORS AND PACKBOARD.SDR P9RA20040057Slide · unlatchedCCS GATE, L4 DOOR INADVERTANTLY OPENED IN THE ARMED POSITION. SLIDE DID NOT INFLATE AS CREW MEMBER REACTED AND HELD DOOR TOWARDS THE CLOSED POSITION. THE SLIDE DID SEPARATE FROM THE DOOR. POWER ASSIST BOTTLE DISCHARGED. MAINTENANCE REINSTALLED L4 DOOR SLIDSDR SWAA043658Slide · out of adjustL2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR P9RA20040056Bolt · backed outMAINTENANCE ENTRY L4 DOOR ARMED CONDITION INDICATOR INOPERATIVE. PLACED ON MEL 25-66-4. MAINTENANCE ENTRY 12/19/2004. REFERENCE MEL 25-66-4. REINSTALLED BOLT IN CONTROL ROD MECHANISM. BOLT HAD BACKED OUT OF NUTPLATE. OPS CHECKED NORMAL AND REMOVED MEL.SDR SWAA043656Slide · out of adjustL2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR UPS04143612Switch · dirtyHAD TO CYCLE THE ESCAPE SLIDE ARMING LEVER SEVERAL TIMES TO INDICATED PROPER SLIDE, ARMED AND DISARM ON ECAM DOOR GAGE. ITEM DEFERRED ON M293373 PER MEL 52-30-04 PLACARD INSTALLED. T/S FOUND ESCAPE SLIDE SWITCH 13WN STICKING. CLEANED SWITCH. SYSTEM OPS CK SDR TSAA0425082Slide · deployedDURING GROUND MAINTENANCE, GROUND CREW INADVERTENTLY DEPLOYED THE FORWARD SERVICE DOOR ESCAPE SLIDE. NO INJURIES. REMOVED AND REPLACED THE FORWARD SERVICE DOOR SLIDE IN ACCORDANCE WITH MM 25-61-200.SDR SWAA043663Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA043661Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA043654Slide · out of adjustL2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR 2004UALA01226Aspirator · misinstalledCRACKED UPPER TUBE ASPIRATOR. ASPIRATOR DAMAGED DUE TO IMPROPER PACKING DURING PREVIOUS OVERHAUL. REPLACED ASPIRATOR.SDR SWAA043643Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR 2005F00007Lanyard · misroutedDTW - FOUND R1 DOOR SLIDE PULL HANDLE, INSPECT PULL HANDLE ROUTING. INSPECTED AND CORRECTED PULL LANYARD ON R1 DOOR SLIDE. NO OTHER DEFECTS NOTED. (M)SDR 2004UALA01230Relay · failedLEFT SQUIB ON NR 1 ESCAPE SLIDE WILL NOT TEST. REPLACED RELAYS K3, K4, K5, & K6 ON M1135 MODULE ABOVE LEFT AFT OVERWING DOOR PER WIRING DIAGRAM 25-65-11 AND PERFORMED REPETITIVE ITERATIONS OF SQUIB TEST. ALL CHECKS GOOD.SDR 2004UALA01228Aspirator · dentedLOW BOTTLE PRESSURE. FOUND DURING ASPIRATOR INSPECTION THAT BOTH ASPIRATORS HAD DENTED BARRELS. LOW BOTTLE PRESSURE: CYLINDER ASSEMBLY TEMPERATURE WAS STABILIZED AND GAGE NEEDLE WAS OBSERVED IN CENTER OF GREEN BAND. CYLINDER ASSEMBLY WAS LEAK CHECKED. NO LESDR 2004UALA01227Bottle · dischargedESCAPE SLIDE HAS A LOW BOTTLE. CYLINDER ASSEMBLY GAUGE ADAPTER FITTING O-RING LEAKING. REPLACED O-RING.SDR SWAA043639Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA043638Cable · frayedDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EVAC SLIDE GIRT BAR CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR SWAA043634Slide · out of adjustR2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR SWAA043633Slide · out of adjustL2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR 2004UALA01215Fitting · leakingLOW BOTTLE PRESSURE. CHARGE FILL FITTING LEAKING. REPLACED BOTTLE AND VALVE.SDR 2004UALA01217Girt Bar · damagedSLIDE WOULD NOT ARM BY GIRT. INSPECTION SHOWS GIRT WAS OPERATIONAL. THE PACKBOARD CAME IN WITH MAJOR DAMAGE. GIRT WAS CHECKED FOR CORRECT POSITIONING AND LENGTH PER P-11886 PACKING MANUAL. SLIDE HAS NO RECENT HISTORY OF GIRT REPAIR. NO CAUSE FOR REPORTED SDR SWAA043628Cable · misroutedDURING SCHEDULED C1 CHECK, FOUND L2 AND R2 DOOR EVAC SLIDE GIRT BAR CABLES MISROUTED. REROUTED R2 AND L2 DOOR EVAC SLIDE GIRT BAR CABLES PER MM.SDR SWAA043625Slide · out of adjustR2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR SWAA043624Fitting · looseAFT SERVICE DOOR EVAC SLIDE FWD GIRT BAR FITTING LOOSE. REINSTALLED SCREWS PER MM.SDR ASAA0480598Lanyard · disconnectedLAX - PREFLIGHT CHECK, AFT SERVICE L-2 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)SDR ASAA0480597Lanyard · disconnectedSEA - PREFLIGHT CHECK, AFT SERVICE DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)SDR GTIA040860Lanyard · disconnectedDTW - FOUND L1 DOOR EVAC SLIDE DEPLOYMENT LANYARD DISCONNECTED FROM SLIDE ASSY. REMOVED AND REPLACED L1 DOOR EVAC SLIDE. (M)SDR UPS04143603Slide · lowDOOR SLIDE IS MARGINAL (LOW). REMOVED AND REPLACED DUAL ESCAPE SLIDE IAW MM 25-61-21-4.SDR P9RA20040052Bulb · inoperativeDTW GATE, L2 SLIDE ARM LIGHT FAILS TO ILLUMINATE WHEN DOOR ARMED. RELAMPED L2 SLIDE ARM LIGHT IAW MM.SDR P9RA20040054Bulb · inoperativeIN MAINTENANCE LAS, SLIDE ARM LIGHTS AT R2 AND R3 DOORS INOPERATIVE. RELAMPED EMERGENCY SLIDE ARM LIGHTS IAW MM.SDR SWAA043601Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR VW3R200400004Girt Bar · mislocatedGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PAD RIDES UP ON CAVITY RIDGE OF GIRT BAR.SDR AMTA200401484Proximity Sensor · malfunctioned1R SLIDE LIGHT DOES NOT EXTINGUISH WHEN DOOR IS DISARMED. REMOVED AND REPLACED 1R DOOR FWD SLIDE ARM PROX SENSOR IAW AMM. OPS CHECKED GOOD. OK FOR SERVICE.SDR 2004UALA01203Slide · deployedDURING SERVICING, CATERERS REPORTED THAT THE DOOR 1R WAS OPEN AND HAD THE SLIDE PARTIALLY DEPLOYED. THE DOOR WAS NOT DISARMED. CAUSE IS UNKNOWN. A SLIDE COMPARTMENT (CLAMSHELL) LATCH WAS FOUND OPENED DURING INSPECTION. WHETHER THE LATCH WAS OPENED WHILE ISDR BB04093Girt Bar · unserviceablePHL, THE L4 DOOR WOULD NOT ARM. MAINTENANCE REPLACED THE GIRT BAR.SDR AMTA200401476Girt Bar · out of positionUNABLE TO ARM L -1 DOOR. REPOSITIONED GIRT BAR AFTER REMOVING DEBRIS. OPS CHECK NORMALLY. ARMED SEVERAL TIMES. OK FOR SERVICE IAW MM 52-11-25/501.SDR SWAA043559Cable · misroutedDURING SCHEDULED 1/4D CHECK, FOUND R2 DOOR EVAC SLIDE CABLE MISROUTED. REROUTED CABLE PER MM.SDR SWAA043547Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND FWD ENTRY DOOR EVAC SLIDE FWD AND AFT GIRT BAR FLOOR FITTINGS BRACKETS, CORRODED. REMOVED AND REPLACED FWD AND AFT GIRT BAR FITTINGS PER SRM.SDR SWAA043543Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.
Back to JASC 2565