JASC 2620
Service difficulty reports · 703
Reports filed under 2620 · Extinguishing System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2620' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2620' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2017040320347Warning Light · false activationDURING PREFLIGHT, OBSERVED DISCHARGE LIGHT ILLUMINATED ON CARGO FIRE PANEL. ACFT GROUNDED. PERFORMED FIM 26-23 TASK 802. AFTER DISCONNECTING CONNECTOR FROM NR 1 BOTTLE PRESSURE SWITCH, LIGHT EXTINGUISHED. INSPECTED CONNECTOR WITH NO FAULTS FOUND. INSTALLED TSDR I5PA2017032802Discharge Tube · brokenAFT CARGO FIRE BOTTLE NR 2 DISCHARGE LINE BROKEN. REPLACED DISCHARGE LINE TUBE PER AMM 26-23-02. WORK ACCOMPLISHED ON ATS JOB 722361 NRC 00348.SDR IPXA2017030314642Latch · inoperativeFIRE EXTINGUISHER LATCH IN COURIER SECTION WILL NOT CLOSE. ADJUSTED THE QUICK-RELEASE STRAP AND INSTALLED THE FIRE EXTINGUISHER IAW AMM 26-24-01, PB 401, REV 88.SDR ASAA2017022819969Warning Light · false activationDURING PREFLIGHT, A CARGO FIRE DISCHARGED LIGHT ILLUMINATED. ACFT GROUNDED. THE LIGHT WENT OUT ON ITS OWN. ACCOMPLISHED FIM 26-23 TASK 802. DISCHARGED LIGHT REMAINS OFF. VERIFIED NO DISCHARGE INDICATION IN CARGO BAY. OPS CHECKED NORMAL IAW AMM 26-16-00-710-SDR DALA2017021901359Line · no testFOUND THREE FIRE EXTINGUISHER SUPPLY FLEX LINES BAD DURING A EXTINGUISHING LINE LEAK TEST IAW AMM 26-20-01-201. REPLACED THE LINES. (LP9119701)SDR R61A201701220059Extinguisher · inoperativeDURING FLIGHT, CREW RECEIVED A CRG FWD FIRE SYS FAIL MESSAGE. DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE, LANDED WITHOUT INCIDENT. REMOVED AND REPLACED FIRE BOTTLE IAW AMM AND OPS CHECKED GOOD.SDR HALA2016122100557Extinguisher · overpressuredAPU FIRE EXTINGUISHER OVERPRESSURE INDICATION RED DISK FOUND WHITE ON PREFLIGHT INSPECTION. REPLACED APU FIRE EXTINGUISHER INDICATOR DISK WITH RED DISK. IAW AMM 26-22SDR C77A20161219003Warning Light · illuminatedIN FLIGHT THE CREW RECEIVED A CARGO FWD FIRE SYSTEM FAIL EICAS MESSAGE. AN EMERGENCY WAS DECLARED AND THE FLIGHT PERFORMED AN AIR RETURN TO DEPARTURE.SDR UIEA2016120600988Suppression Sys · malfunctionedCARGO FIRE BOTTLE DISCHARGE LIGHT IS ON. TROUBLESHOT IAW FIM TASK 26-23 FAULT TREE 813. RESET DISCHARGE LINE PRESSURE SWITCHES 5661 AND 5662. RETESTED CARGO FIREX SYSTEM IAW AMM 26-23-00. TESTED SATISFACTORY.SDR UIEA2016112200867Extinguisher · corrodedAFT LAVATORY AUTOMATIC FIRE EXTINGUISHER FOR WASTE CAN HAS CORROSION. REPLACED THE FIRE EXTINGUISHER IAW AMM 26-24-01-400-801.SDR UIEA2016112200869Extinguisher · corrodedAUTOMATIC FIRE EXTINGUISHER FOR LAVATORY WASTE CAN CORRODED ALONG SEAM. AFT LAV CENTER LH(<P>REMOVED AND REPLACED AUTOMATIC FIRE EXTINGUISHER FOR LAV WASTE CAN FOR AFT CENTER L/H LAV IAW B767 AMM 26-24-01-400-801</P>)SDR UIEA2016120600977Ground Stud · corrodedAFT CENTER LAV R/S SHELF WHERE AUTOMATIC FIRE EXTINGUISHER MOUNTS TO LAV WASTE CAN GROUND SCREW CORRODED. REMOVED AND REPLACED GROUND SCREW IN AC-4 LAV AUTOMATIC FIRE EXTINGUISHER IAW B767 SRM 51-40-02-060 AND B767 AMM 20-11-00-910-002.</P>)SDR UIEA2016120200964Fire Bottle · dischargedAPU FIRE WARNING AT CRUISE. BOTTLE DISCHARGED.SDR UIEA2016113000938Tube · dentedAFT CARGO BAY FIRE EXTINGUISHER SYSTEM TUBE IS DENTED. REPLACED IAW AMM 26-23-11.SDR SIMA20160929003Button · defectiveCARGO AFT SMOKE WARNING, CARGO AFT & FWD FIRE SYS FAIL, CARGO AFT FIREX LO ARM ADVISORY, CRG FIREX HI DISCH STATUS ON. TAXIING IN TO THE RAMP TO PARK, TRANSFERRED TO NRWC 022-DFW-00205. R&R AFT CARGO FIRE EXTINGUISHING PUSHBUTTON ON FIRE EXTINGUISHER CONTROLSDR VNAA2016091700020Fire Bottle · low pressureAFT CARGO FIRE BOTTLE LOW CAUTION. THE CREW DIVERTED TO NEAREST FIELD AND LANDED WITHOUT INCIDENT. TECHNICIANS REMOVED AND REPLACED THE AFT CARGO FIRE BOTTLE IAW CRJ-200 AMM . OPS CHECK GOOD. AIRCRAFT RELEASED FOR SERVICE.SDR FDEA201608022774Regulator · failedAFT CARGO FIRE EXTINGUISHING DISCHARGE SYSTEM FAILED FUNCTIONAL CHECK. REPLACED AFT CARGO FIRE EXTINGUISHER REGULATOR IAW AMM 26-23-03-4. PERFORMED SYS TEST OF AFT CARGO METERED DISCHARGE LINES IAW AMM 26-23-00-5.SDR UIEA2016062800528Control Panel · defectiveCARGO FIRE PANEL, COCKPIT P8 PANEL, BOTTLE DISCHARGE LIGHT DOES NOT COME ON WHEN TESTED. APU AND FIRE CONTROL PANEL REPLACED IAW AMM 26-22-03.SDR UIEA2016062700484Cap · damagedNOSE WW ON P-40 PANEL LIGHT CAPS OF FIRE BOTTLE ARM LIGHT. BOTTLE DISCHARGE LIGHTS ARE DAMAGED. REPLACE LIGHT CAPS OF FIRE BOTTLE ARMED AND BOTTLE DISCHARGE IAW AMM 26-15-01.SDR UIEA2016062700520Coupling · damagedAFT CARGO TUBING EXTINGUISHER ARMFLEX IN BAD CONDITION. AFT CARGO COMPARTMENT FIRE EXTINGUISHER TUBING ARMFLEX REPLACED IAW AMM.SDR UIEA2016062000440Module · faultyFOUND LOWER CARGO FIRE BOTTLE B, CHANNEL 2 CONNECTOR VOLTAGE ABNORMAL DURING TEST IAW AMM 26-21-01-004-001 AND 26-21-01-404-006, REV 86. REPLACED FIRE MODULE AND CONNECTION CHECK NORMAL IAW AMM 26-21-01-734-305, REV 86 PERFORMED FIRE CONTROL MODULE INSTALLATISDR REXA2016032600506Guard · brokenCARGO COMPARTMENT FIRE EXTINGUISHER LINE GUARD BROKEN WITH MISSING HARDWARE. INSTALLED NEW SERVICEABLE CARGO COMPARTMENT FIRE EXTINGUISHING LINE GUARD WITH NEW SERVICEABLE HARDWARE IAW AMM 26-25-07-400-801.SDR GTIA2016032201508Union · chafedTHE CONNECTOR THAT ATTACHES THE FIRE BOTTLE AND FIRE BOTTLE DISTRIBUTION PIPE BECAMES LOOSE, CONNECTOR NOT SAFETIED AND BACKED OFF FROM THE FIRE BOTTLE, BACK AS FAR AS POSSIBLE, CONTACTING A DRAIN LINE AND CHAFED A HOLE IN THE DRAIN LINE AND VIBRATED AND CUT ISDR P5CA2016022900048Tube · damagedAFT CARGO FOUND FIRE EXT. TUBES PN 453T2620-273 AND PN 453T2620-135 DAMAGED. REPLACED TUBES IAW AMM 26-23-11, REV 116 AND CONV J/C 371-26-20-C1361-001.SDR P5CA2016022900051Tube · damagedAFT CARGO LT AT BS 1197+66, FOUND FIRE EXT TUBE, DAMAGED. REPLACED TUBE IAW AMM 26-23-11, REV 116.SDR UIEA2016020600076Fire Bottle · damagedFOUND MAIN DECK CARGO HALON FIRE EXTINGUISHER DAMAGE AT SWING TAIL RT, LT & TTL 2 EACH. IAW AMM 26-26-01-000-801 REV 85 & AMM 26-26-01-400-801 REV 85 REPLACED MD CARGO HALON FIRE EXTINGUISHER AT SWING TAIL RT & LT, TTL 2 EACH. JOB COMPLETED & COND CHECKED NOSDR FDEA201602010420Line · chafedRIGHT WING LE FIRE SUPPRESSION LINE WS 321, FOUND CHAFED THROUGH FROM SLAT TORQUE TUBE COUPLING NOT SECURED, MISSING BOLTS TO SECURE THE COUPLING. REF N00060, N00061, N00062. R & R RT WING LE FIRE SUPPRESSION LINE AT WS 321 IAW AMM 20-10-09.SDR FDEA201601220282Warning System · activatedFSS DURING PREFLIGHT AT DEPARTURE WAS FULLY OPERATIONAL, AFTER LEVEL OFF IT WAS NOTED THAT POSITION 2, 3, 4, 5, 8, 9 & 11 WERE FAULTED WITH THE MSG ACCESSIBLE DANGEROUS GOODS POSITION INOPERATIVE. WRI 26-24 6635 TO BE FACTED OUT DUE TO SHORT TERM DEACTIVATIONSDR A6WA2016011343456Fire Bottle · emptyLAVATORY FIRE EXTINGUISHER FOUND EMPTY. R & R FIRE BOTTLE. ACFT WAS OUT OF SERVICE AT THE TIME OF DISCOVERY.SDR QXEA2015121100647Fire Bottle · reads lowMASTER WARNING, CHECK FIRE DETECTOR. APU BOTTLE, LOW LIGHT ILLUMINATED AT 25,000 AND -42 DEGREES C. REPLACED APU FIRE BOTTLE IAW AMM TASK 26-23-01-000-801/400-801. OPS TEST GOOD NO FURTHER DEFECTS NOTED. RETURNED TO SERVICE.SDR DXTA2015120306135Warning Light · false activationFIRE BOTTLE LOW INDICATOR CAME ON INFLIGHT AT FL380, STAYED ON THROUGH FL240. REMOVED BOTTLES, WEIGHED BOTTLES, FWD BOTTLE WEIGHED 7.05 POUNDS, LAST CHARGED IN 10 2015 & WEIGHED 7.06 POUNDS. AFT BOTTLE WEIGHED 7.00 POUNDS, LAST CHARGED 3 2014 & WEIGHED 7.06SDR FDEA201512073941Control Panel · faultedFSS PANEL CONTINUOUSLY FAULTS, ARGON PRESSURE, THEN BLINKS BLANK & BACK TO NORMAL EVERY 5 SECONDS. THEN STOPS FOR A FEW MINUTES & FAULTS AGAIN. SERVICED TO 2900 PSI IAW MM 26-00-120. NO LEAKS NOTED IAW 26-00-111. COMPLIED WITH POST MX RTS IAW 26-00-450. SDR GLBA2015111700560Warning System · false activationPILOT REPORTED THAT WHILE IN CRUISE, THE DISCHARGE LIGHT ON THE NR 1 FIRE EXTINGUISHER ILLUMINATED. REPLACED SOFT SPLICE, PN M81714/11-20D, ON WIRE W23B22 IAW EO 13-1900-26-001. OPERATIONAL CHECK OF DISCHARGE INDICATION GOOD.SDR FDEA201507252393Connector · damagedENGINE FIRE AGENT LOW, LEVEL ONE ALERT IN FLIGHT. NR 2 ENGINE AGENT 2 LOW, NO OTHER ADVERSE INDICATIONS. BOTTLE WAS FOUND NOT TO BE DISCHARGED. R & R CONNECTOR P1-1263. R & R BOTH AGENT LOW PRESSURE TO TEST SWITCHES AT REMOTE APU PANEL. SECURED CLAMPS & SDR C77A20150524020Gauge · inaccurateDURING ROUTINE CHECK FOUND AFT LAVATORY EXTINGUISHER READING 0 PSI. R & R AFT LAVATORY WASTE COMPARTMENT FIRE BOTTLE IAW AMM 26-25-01 ON WO 19026412T5. OPERATIONS CHECKED GOOD. PN BA22649-1 & SN 35325.SDR FDEA201505111485Extinguisher · unwanted deployON ACFT POWER UP THE FWD LOWER CARGO NR 1 FIRE COMPARTMENT EXTINGUISHER NR 1 CYLINDER DISCHARGED. REMOVED FWD CARGO FIRE EXT CONTAINER NR 1 IAW MM 26-22-01-4-1.SDR VGCA20150427002Fire Bottle · failedRIGHT ENG ZONE 2 FIRE INDICATION APPEARED. FOLLOWED PRECAUTIONARY ENG SHUTDOWN & FIRE BOTTLES WERE DISCHARGED. WHILE PERFORMING MX, VISUALLY VERIFIED BOTH RT, FWD & RT AFT FIRE BOTTLES FAILED TO DISCHARGE.SDR FDEA201503130920Fire Bottle · low pressureENGINE FIRE AGENT LOW ALERT ON DEU. TROUBLESHOT IAW FIM 26-21-00-2-0. FOUND NR 1 ENGINE FIRE BOTTLE 1 WITH LOW PRESSURE SWITCH BAD. R & R THE NR 1 ENGINE FIRE BOTTLE IAW AMM 26-21-01-4. OPS CHECKED GOOD IAW 26-21-01-5. ACFT OK FOR SERVICE.SDR FDEA201502250597Warning System · activatedDURING CRUISE FLIGHT AT FL 360 WE RECEIVED A FIRE SUPPRESSION SYSTEM DISH GLARE SHIELD LIGHT. AT THE SAME TIME THE JUMPSEATERS IN THE COURIER AREA CONTACTED US & SAID THAT THE FIRE SUPPRESSION SYSTEM DISPLAY INDICATED A RED DISCHARGE BAR IN POSITIONS 1R & 1C.SDR CA150223004Switch · shorted(CAN) DURING SCHEDULED MAINTENANCE, WHEN THE AFT CARGO FIRE BOTTLE TEST BUTTON WAS DEPRESSED, BOTH AFT CARGO FIRE EXTINGUISHERS DISCHARGED. INVESTIGATION FOUND THE Ï¿½PUSH TO DISCHARGEÏ¿½ SWITCH ON THE CARGO FIRE PANEL WAS SHORTED INTERNALLY CAUSING THE BOTTLESDR CA150206005Cartridge · defective(CAN) FLIGHT AIRBORNE, DIVERTED BACK TO DEPARTING STATION DUE FIRE DETECTION WARNING IN THE FWD CARGO HOLD. FIRE SUPPRESSION BOTTLES WERE DEPLOYED. ACFT WAS MEET BY CFR ON THE RNWY. THE FLIGHT LANDED BELOW MAX LANDING WEIGHT. UPDATE, MAYDAY DECLARED. FIRE SDR IPXA2015020485564Pressure Switch · failedNR 3 ENGINE, AGENT 1 WOULD NOT DISCHARGE FIRE BOTTLE, CONFIRMED FAULTY PRESSURE SWITCH. R & R BOTTLE ASSY IAW AMM.SDR CALA2015011993001Control Panel · misinstalledENGINE FIRE HANDLE PANEL INSTALLED UPSIDE DOWN. FIRE HANDLE POSITIONS REVERSED WITH GRAPHICS UPSIDE DOWN. REMOVED & REINSTALLED PANEL TO CORRECT POSITION. NO DISCREPANCIES NOTED WITH WIRE BUNDLES ROUTING. FIRE TESTS NORMAL AFTER REINSTALLATION.SDR HNAA2015011200015Fire Bottle · no testBOTH FORWARD ENGINE FIRE BOTTLES WILL NOT TEST. GAUGE READS ZERO ON FORWARD BOTTLE. MISSING YELLOW DISCHARGE DISC. R & R FIRE BOTTLE AND FORWARD SQUIB IAW WORK CARD 26-20-05X, 26-20-04F AND 26-20-22X. OPS CHECKED GOOD, OK FOR SERVICE.SDR FDEA201411063539Fire Bottle · dischargedMULTIPLE BIRD STRIKES DESCENDING TO 7000 FT. RECEIVED ENGINE FIRE AGENT LOW, AGENT 2 LOW NR 3 ENG, ALERT. NO ADDITIONAL ENG ANOMALIES NOTED. REMOVED NR 3 ENGINE, AND NR 2 FIRE BOTTLE IAW AMM 26-21-01-4. VERIFIED BOTTLE WAS DISCHARGED. CHECKED WIRING FROM FSDR SWAA2014110733899Duct · overheatedCARGO FIRE PANEL DISPLAYS BOTTLE DISCHARGED 2 & MX LIGHTS ILLUMINATED. FOUND DUCT OVERHEATED. R & R SUPPRESSION CONTROL UNIT IAW AMM.SDR AALA20141003007Control Panel · faultyRIGHT ENG FIRE BOTTLE DISCHARGE LIGHT ILLUMINATED. EMER DECLARED FLIGHT DIVERTED & LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED FAULTY LINK CONTROL PANEL & NR 2 FIRE BOTTLE. SYS GND CHECKED NORMAL OPERATION CLOSED.SDR RAIA201409140002Fire Bottle · no testCOCKPIT FIRE BOTTLE FAILED WEIGHT CHECK. MAINTENANCE REPLACED COCKPIT FIRE BOTTLE, OPS CHECKED GOOD.SDR QXEA2014081600680Extinguisher · low pressureCHECK FIRE DETECTOR WARNING LIGHT ILLUMINATED RT AFT BAGGAGE BOTTLE LOW. REPLACED AFT HIGH-RATE FIRE BOTTLE IAW AMM TASKS 26-22-02-000-801 & 26-22-02-400-801. OPS CHECKED GOOD. RETURNED TO SERVICE.SDR FDEA201407312024Cable · damagedFOUND NR 3 ENGINE FIRE HANDLE SHUTOFF CABLE CORRODED & SEVERAL STRANDS BROKEN. REMOVED AND REPLACED NR 3 EMERGENCY SHUTDOWN CABLE IAW MM 76-20-00-5.OPS CHECKED NORMAL IAW MM 76-20-00-5-1.
Back to JASC 2620