JASC 2621
Service difficulty reports · 623
Reports filed under 2621 · Fire Bottle, Fixed, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MASA2011062403082Fire Bottle · low pressureCARGO BOTTLE LOW CAUTION. R2 CARGO BOTTLE.SDR MASA2011061302995Fire Bottle · no testNR 1 FIRE BOTTLE WILL NOT TEST. R2 NR 1 ENGINE FIRE BOTTLE.SDR MASA2011060702954Fire Bottle · low pressureCARGO BOTTLE LOW CAUTION. R2 CARGO BOTTLE AND PERFORMED LEAK CHECKS OF BLEED SYSTEM.SDR VNAA2011060600025Warning System · false activationCREW REPORTED CARGO BOTTLE LOW CAS MESSAGE CAME ON AT FL260 EN ROUTE FROM CLT TO XNA. CAS MESSAGE WENT OUT ON DESCENT ABOUT FL210 TO FL200. CREW DIVERTED TO TYS AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED CARGO FIRE BOTTLES, FOUND BOTTLES TO BE FULL SDR MASA2011060102913Fire Bottle · dischargedLEFT ENG FIRE BOTTLE EXTINGUISHED. R2 LEFT ENG BOTTLE.SDR USAA2011051691854Fire Bottle · dischargedFLT 1503 - CLT-ATL - DIVERSION / FIRE INDICATION - CARGO SMOKE DISCHARGE LIGHTS ILLUMINATED, "BOTH" IN FLIGHT. REMOVED AND REPLACED FIRE EXTINGUISHER BOTTLE IN FORWARD CARGO COMPARTMENT PER AMM 26-23-41. PERFORMED FUNCTIONAL TEST AND NO DEFECTS WERE NOTED.SDR UALA2011050902245Cartridge · faultyAPU AUTO SHUTDOWN WITH APU BTL DISCHARGE LIGHT. REPLACED APU FIRE EXTINGUISHER BOTTLE AND DISCHARGE CARTRIDGE PER MM. UNIT CHECKS OKAY AT THIS TIME.SDR MASA2011042802526Light · malfunctionedNR 1 ENG BOTTLE PUSH TO DISCHARGE LIGHT NOT ILLUMINATE. CYCLED POWER TO FIRE EXT AND RESET CONNECTOR ON BOTTLE.SDR MASA2011042202480Spring · inoperativeLAVATORY FIRE EXTINGUISHER SYS CONSDIERED INOP. R & R FLAPPER SPRING.SDR MASA2011042202479Fire Bottle · inoperativeLAV FIRE EXT CONSIDERED INOP. REMOVED AND REPLACED SPRING.SDR MASA2011042002456Fire Bottle · low pressureCARGO BOTTLE LOW CAUTION. R2 AFT CARGO FIRE BOTTLE & SQUIB ASSY.SDR MASA2011042002454Fire Bottle · defectiveAFT CARGO SQUIB CAUTION. R2 AFT CARGO FIRE BOTTLE & SQUIB ASSY.SDR R61A20110089Fire Bottle · failedCREW REPORTED E-1 AND E-2 FIREXBTL A FAIL MSG IN FLIGHT, EMERGENCY WAS DECLARED BY ATC AND EMERGENCY VEHICLES WERE DISPATCHED. THE A/C LANDED WITHOUT INCIDENT AT DCA. MAINTENANCE REMOVED AND REPLACED E-1 & E-2 FIRE BOTTLE A PER EMB AMM, OPS CHECK GOOD.SDR UALA2011041201766Switch · faultyEXTINGUISHER 1 BTL LT WILL STAY LIT WHEN TESTED. RPL NR 1 CARGO BTL DISCHARGE SWITCH, ACP TEST FROM BOTTLE TO SWITCH, TESTED GOOD PER MM. (PART# 563-3386)SDR UALA2011040101577Fire Bottle · dischargedAPU INOP DUE TO APU BOTTLE DISCHARGE LIGHT ON. REPLACED APU FIRE EXT BOTTLE PER MM.SDR CA110321018Extinguisher · empty(CAN) DURING BASIC INSPECTION FOUND NR 1 FIRE EXTINGUISHER AT ZERO.SDR UALA2011031001159Fire Bottle · dischargedNR 1 ENG FIRE EXTINGUSHING BOTTLE EICAS MESSAGE AND BOTTLE ENG NR 1 INDICATING LIGHT ILLUMINATED. FOUND NR 1 FIRE BOTTLE DISCHARGED. REPLACED NR 1 FIRE BOTTLE PER MM. OPS CHECKED AND TESTED FIRE BOTTLE SYSTEM PER MM.SDR VNAA2011030900004Fire Bottle · low pressureCREW REPORTED APU FIRE MESSAGE, APU BOTTLE LOW AND APU AUTOMATICALLY SHUT DOWN ON TAXI OUT AT DCA. NO VISIBLE SMOKE OR FIRE. MESSAGE EXTINGUISHED. CREW FOLLOWED QRH AND RETURNED TO THE GATE. MAINTENANCE INSPECTED APU COMPARTMENT AND FOUND NO VISUAL SIGNS OSDR CA110308009Extinguisher · contaminated(CAN) DURING A PREFLIGHT INSPECTION, THE ENGINE FIRE EXTINGUISHER WAS FOUND WITH ZERO PRESSURE. DURING REMOVAL OF THE EXTINGUISHER, WATER WAS FOUND IN THE MANIFOLD.SDR UALA2011012500410Switch · inoperativeNR1 BOTTLE DISCHARGE LIGHT WON'T STAY ON. REPLACED NR 1 BOTTLE DISCHARGE SWITCH. DISCHARGE LIGHT NOW STEADY IN TEST.SDR UALA2011011400235Bottle · low pressureBOTTLE 1A CARGO STATUS MESSAGE DISPLAYED (MM MESSAGE 26-40010). FOUND CARGO FIRE EXT BOTTLE 1A WITH LOW PRESSURE INDICATION. NEEDS BOTTLE REPLACEMENT. MEL PROCEDURES COMPLIED WITH INCLUDING LLCR AREA DEACTIVATION. LLCR AREA MUST NOT BE USED.SDR IPXA11564457Support · crackedINSPECTION TYPE:C1, TAIL COMPARTMENT, APU FIRE BOTTLE MOUNTING SUPPORT TRAY CRACKED AT SEVERAL HOLES. REPLACED IAW SRM & DWG.SDR SIMA201100302Fire Bottle · dischargedDURING PREFLIGHT INSPECTION FOR FLIGHT 3650 THE FLIGHT ATTENDANT DISCOVERED THE LAVATORY FIRE EXTINGUISHER BOTTLE INDICATOR IN THE RED ARC. THE FIRE EXTINGUISHER BOTTLE APPEARED TO HAVE BEEN DISCHARGED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPSDR 2010FA0001165Fire Bottle · leakingDURING A L1/L2 INSP THE GALLEY AND LAVATORY TRASH BIN FIRE EXTINGUISHER BOTTLES WERE REMOVED FOR A WEIGHT CHECK. A VISUAL INSP REVEALED THAT BOTH BOTTLES WERE EMPTY, THE PLUGS THAT ARE NORMALLY SOLDERED IN THE DISCHARGE TUBES HAD MIGRATED PARTIALLY OUT AND RELSDR CA101015009Seal · failedCREW REPORTED SEAL ON THE HALON FIRE EXTINGUISHER IN THE COCKPIT FAILED ON PUSHBACK DISCHARGING THE EXTINGUISHING AGENT. ACFT RETURNED TO GATE AND BOTTLE WAS REPLACED. OPERATOR HAS EXPERIENCED SIMILAR INCIDENTS IN THE PAST. REF SDR 20070809003 AND SDR 200708SDR MYWA100109Fire Bottle · unserviceableETOPS SIGNIFICANT SYSTEM: APU FIRE BOTTLE NOT SERVICABLE.SDR MASA2010092101014Fire Bottle · low pressureCARGO BOTTLE LOW IN FLIGHT, CREW DECLARED EMERGENCY AND DIVERTED. MX REPLACED LEFT FIREX BOTTLE.SDR QXEA2010091700542Fire Bottle · malfunctionedMASTER CAUTION CHECK FIRE DETECT BOTTLE LOW APU INTERMITTENT ON APPROACH AND AFTER LANDING, EVENT MARKER PRESSED. R & R APU FIRE EXTINGUISHER BOTTLE IAW AMM TASKS 25-23-01-000-801/ 400-801. SYS TESTED GOOD. RETURNED TO SERVICE.SDR DXTA2010091304235Fire Bottle · dischargedNR 1 ENGINE FIRE BOTTLE INADVERTENTLY DISCHARGED IN FLIGHT. IT`S THE MIDDLE BOTTLE IN THE AFT SERVICE COMPARTMENT. CHECKED CARTRIDGE FIRING CIRCUIT FOR VOLTAGE AND FOUND NONE. REPLACED THE LT FIRE EXTINGUISHER AND ENGINE EXTINGUISHER CARTRIDGES. CONDUCTED TSDR UALA2010090303249Fire Bottle · out of toleranceBOTTLE 2A CARGO, BOTTLE 2B CARGO, AND BOTTLE 2C CARGO STATUS MESSAGES DISPLAYED ON LOWER EICAS. ACCOMPLISHED GROUND TEST 26 CARGO SQUIB TEST, TEST FAIL. CIRCUIT OPEN. REF MAT MAINT MSG FAULTS 26 -40100, 26-40110, 26-40120, REPLACED ELMS P310 I-O CARD M24406A7,SDR AALA20100902MIA01Fire Bottle · faultedMIA - CREW REPORTED AFTER TAKEOFF FORWARD CARGO FIRE DETECTION AGENT DISCHARGE LIGHT ILLUMINATED. FLIGHT RETURNED MIA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED FORWARD CARGO FIRE BOTTLE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR A6WA201040668Fire Bottle · low pressureCARGO BOTTLE LO MSG IN FLT. C/W QRH- DIVERTED. LANDED AT 37500 WEIGHT. CFR REPORTS NO FIRE/SMOKE- PLACARD AND PLACED ON MEL. R & R LT FIRE BOTTLE IAW AMM 26-25-01. OPS CK GOOD REMOVED PLACARD. REMOVED FROM MEL.SDR MASA2010082000900Fire Bottle · low pressureCARGO FIRE BOTTLE LOW PRESSURE CAUTION MESSAGE. MX R2 CARGO FIRE BOTTLE.SDR HALA2010071600308Warning System · false activationBTB: SMOKE FWD CARGO BOTTLE 1&2 FAULT / AFT CARGO BOTTLE 1&2 FAULT. RESET SDF1 & SDF2. OK FOR SERVICE. SDF SYSTEM TEST OKAY.SDR UALA2010062302212Fire Bottle · underservicedFWD PIT FIRE BOTTLE 'A' IS UNDERSERVICED. REPLACED "A" BOTTLE.SDR UALA2010052801845Squib · underservicedCARGO FIRE EXT BOTTLE 2 AFT SQUIB UNDERSERVICED. REPLACED SQUIB IAW MM.SDR EIAA2010041Fire Bottle · defectiveDURING COCKPIT TEST FOUND NR 1 ENGINE LEFT FIRE BOTTLE SQUIB INTERMITTENTLY DOESN'T TEST. REMOVED AND REPLACED NR 1 ENG FIRE BOTTLE IAW MM 26-21-03, TEST OK.SDR UALA2010042901438Safety Wire · missingAFT HALON FIRE EXTINGUISHER SAFETYWIRE MISSING. MX COMPLIED WITH MEL PLACARD 2624 A. BOTTLE REMOVED FROM THE ACFT AND ROUTED FOR SHIPMENT BACK TO AN OPERATOR STATION. INSTALLED HALON FIRE EXTINGUISHER.SDR ASOA201000543Fire Bottle · lowCARGO BOTTLE LOW ILLUMINATED. REMAINED ON 10 TO 15 MIN. AND THEN EXTINGUISHED. (EMERGENCY DECLARED) (CARGO COMPARTMENT FIRE EXTINGUISHING SYSTEM) R & R LRD CARGO FIRE BOTTLE IAW AMM 26-25-01. OPS CHK GOOD. (CLOSED)SDR UALA2010041301251Extinguisher · defectivePRIOR TO DEPARTURE STATUS MESSAGE 26043 - APU BOTTLE LOW PRESSURE DISPLAYED. DEFERRED IAW MEL. APU NOT TO BE USED. BASED ON AHM, THIS IS 1ST HIT. MAY NEED BOTTLE PCN 635 -1090. REPLACED BOTTLE.SDR SIMA201006702Fire Bottle · malfunctionedON FLIGHT 3892 THE CREW REPORTED, RECEIVED A MESSAGE THAT NR 1 ENGINE FIRE BOTTLE WAS INOPERABLE. THE CREW ELECTED TO RETURN TO MIA. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. RESET SYSTEM. NO PARTS REMOVED OR REPLACED. SDR UHLA2010020400004Fire Bottle · faultyIN CRUISE FLIGHT AT FL370 RECEIVED EICAS MESSAGE "CRG AFT FIRE DET FAIL". FWD CRG FIRE EXT SYS ALREADY ON MEL. QRH REQUIRES LANDING AT NEAREST SUITABLE AIRPORT, INFORMED ATC AND DECLARED AN EMERGENCY AFTER REQUESTING A LANDING IN STL. LANDING UNEVENTFUL. MSDR FDEA200911194048Fire Bottle · lowENG FIRE AGNT LO ALERT AND ENG 2 AGT 1 LOW LIGHT DURING CRUISE FOUND NR 2 ENG 1 FIRE BOTTLE LOW PRESS SWITCH BAD, REPLACED NR 2 ENG NR1 FIRE BOTTLE, LIGHT EXT. CHECKS OKSDR R61A20090077Fire Bottle · faultyCREW REPORTED ENG 2 FIREX BTL A FAIL AND ENG 1 FIREX BTL A FAIL MSG ON AND OFF THROUGHOUT FLIGHT TO MKE. MAINTENANCE WAS DISPATCHED TO AIRCRAFT TO TROUBLESHOOT. MTX REMOVED AND REPLACED FIRE EXTINGUISHING BOTTLE A, AND PERFORMED OPS CHECKS EMB AMM. A/C WAS SDR UALA2009082502635Control Module · faultyENG AND APU FIRE CONTROL MODULE WILL NOT TEST NR 2 ENG AND APU SQUIB. REPLACED APU AND APU FIRE CONTROL MODULE, TESTED GOOD.SDR UALA2009082502658Extinguisher · dischargedLOWER FLIGHT CREW REST FIRE BOTTLE EXTINGUISHED INADVERTENTLY BY SECURITY AGENT, ASSOCIATED WITH STATUS MESSAGE: "BOTTLE CREW REST LOWER". REPLACED LLAR MODULE FIRE EXTINGUISHING BOTTLE. ALL TESTS PASSED.SDR YENA20090825100Fire Bottle · faultyFLT 87, JFK-SLC, ENGINE 2 AGENT 2 DISCHARGE LIGHT ILLUMINATED DURING TAXI IN. REMOVED AND REPLACED NR 2 ENGINE, NR 2 BOTTLE PER AMM 26-21-00-05, OPERATION CHECK NORMAL. AIRCRAFT OK FOR SERVICE. P/N OFF 34100005-1, S/N OFF 47689D1, P/N ON 34100005-1, S/N ON SDR C2XA09TY220Fire Bottle · dischargedLAV FIRE BOTTLE READS ZERO. REMOVED AND REPLACED LAV FIRE BOTTLE.SDR REXA200900074Fire Bottle · dischargedJAN/MEM ON APPROACH INTO MEM RECEIVED CARGO BOTTLE LOW CAUTION MESSAGE, QRH FOLLOWED DECLARED EMERGENCY, LANDED WITHOUT INCIDENT CFR, INSPECTED AIRCRAFT NO FIRE OR SMOKE FOUND. TAXIED TO GATE. MAINTENANCE REMOVED AND REPLACED CARGO STANDBY BOTTLE IAW AMM.SDR COMA2009062950165Fire Bottle · lowON CLIMBOUT FROM CHS RECEIVED CARGO BOTTLE LOW MSG. EMERGENCY DECLARED, A/C RETURNED TO CHS LANDED SAFELY. REMOVED AND REPLACED NR 1 CARGO FIRE EXTINGUISHER BOTTLE.
Back to JASC 2621