JASC 2621
Service difficulty reports · 623
Reports filed under 2621 · Fire Bottle, Fixed, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UHLA2013011400085Cartridge · misinstalledENGINE FIRE BOTTLE B CARTRIDGES ARE INSTALLED INCORRECTLY. REPLACED ENGINE FIRE BOTTLE B WITH CORRECT CARTRIDGES INSTALLED IAW AMM 26-22-0.SDR UALA2013010900153Fire Bottle · dischargedAPU FIRE BOTTLE PREMATURELY DISCHARGED. REMOVED AND REPLACED, OPS CHECKED GOOD.SDR UALA2013010300032Button · dirtyDURING NR 1 FIRE BOTTLE SQUIB TEST THE RIGHT LIGHT IS INOP. CLEANED ENGINE 1 SQUIB PUSH BUTTON, OPS NORMAL.SDR COZA20121212019Pressure Switch · intermittentDURING AIRCRAFT POWER UP, FOUND CARGO FIRE DISCHARGE LIGHT ON IN COCKPIT. TROUBLESHOT SYSTEM TO INTERMITTENT PRESSURE SWITCH ON THE CARGO COMPARTMENT FIRE BOTTLE.SDR USAA2012112800022Extinguisher · dischargedLAV D FIRE EXTINGUISHER EMPTY FOR WASTE BIN. REMOVED AND REPLACED LAV D WASTE CONTAINER FIRE EXTINGUISHER BOTTLE.SDR USAA2012111300014Fire Bottle · depletedLAV 'A' AND LAV 'D' FIRE BOTTLES ARE EMPTY. REMOVED AND REPLACED LAVS 'A' AND 'D' FIRE BOTTLES WITH SERVICEABLE EXTINGUISHER BOTTLES.SDR USAA2012110800019Fire Bottle · lowFOUND MID LAV FIRE BOTTLE WEIGHT LOW. REMOVED AND REPLACED MID LAV FIRE BOTTLE IAW AIRBUS MAINTENANCE MANUAL 26-25-41-400-001A.SDR UALA2012092405410Disc · improper partAPU FIRE EXTINGUISHER OVER-PRESSURE INDICATOR BLACK-REQUIRES RED. APU FIRE EXT RED DISC IS PRESENT ON INSPECTION.SDR USAA2012081600015Fire Bottle · low pressureFORWARD LAV FIRE EXTINGUISHER NOT IN GREEN BAND. REMOVED AND REPLACED FORWARD LAV FIRE EXTINGUISHER IAW AIRBUS MAINTENANCE MANUAL 26-25-41.SDR USAA2012080200030Fire Bottle · dischargedENGINE NR 2 AGENT 1 INDICATES DISCHARGE OF FIRE BOTTLE. MAINTENANCE REMOVED AND REPLACED FIRE EXTINGUISHING BOTTLE ON NR 2 ENGINE IAW AIRBUS MAINTENANCE MANUAL 26-21-41-000-001-A.SDR FDEA201207312775Fire Bottle · lowENGINE FIRE AGENT LOW, AT GATE AFTER ENGINE SHUTDOWN. REMOVED AND REPLACED NR 3 ENGINE FIRE DISCHARGE BOTTLES IAW MM 26-21-01-4. PERFORMED ALL ADJ/TEST'S PER MM 26-21-06/ 26-21-01. FOUND BRACKET BROKEN ON PNEUMATIC BLEED DUCT CAUSING UNRESTRAINED FLEX DUCTSDR UALA2012070603645Switch · inoperativeFIRE EXTINGUISHER RESET LIGHT INOPERATIVE. REPLACED SWITCH L26503 PER WDM 26-22-11 AND 26-15-12. OPS CHECKED GOOD.SDR UALA2012070303551Fire Bottle · faulty'ENG FIRE EXTING-DISCH' LIGHT OF 'AGENT 1' ILLUMINATED WITHOUT FIRING BOTTLE 1. FOUND CONNECTOR 6WE2 ON BOTTLE NR 1 ENGINE NR 2 LOOSE, SECURED AND CHECKS NORMAL. PROBLEM RECURRED. REPLACED NR 2 ENGINE, NR 1 FIRE BOTTLE PER MM, SYSTEM OPS CHECKED NORMAL. PASDR A6WA201240648Fire Bottle · low pressureCARGO BOTTLE LOW CAUTION MESSAGE. R & R CARGO FIRE BOTTLE REF SUP 10-099. OPS CHECKED GOOD.SDR A6WA201240646Fire Bottle · low pressureRECEIVED CARGO BOTTLE LOW, CAUTION MESSAGE. R & R CARGO LEFT BOTTLE IAW 10-099. OPS CHECKED NORMAL.SDR A6WA201240647Fire Bottle · low pressureCARGO BOTTLE LOW, CAUTION MESSAGE. R & R LT CARGO FIRE BOTTLE IAW AMM 26, OPS CHECKED GOOD.SDR YENA20120630550Fire Bottle · failedFLT 950 MCO-BOS, AIR RETURN TO MCO DUE TO CRG FWD FIRE SYS FAIL MSG CLIMBING THROUGH 18000 (CARGO COMP FIRE EXTING SYS - FWD/AFT). REMOVED AND REPLACED HIGH RATE CARGO FIRE BOTTLE PER AMM 26-23-01. OPS CHECK OK.SDR R61A201206120310Tube · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE FIRE EXTINGUISHER LINE FORWARD OF SPAR 3 FOR RIGHT ENGINE HAS CORROSION. MAINTENANCE REMOVED AND REPLACED FIRE EXTINGUISHER LINE FORWARD OF SPAR 3 FOR RIGHT ENGINE IAW EMB 175 AMM 20-10-13. THE AIRCRAFTSDR R61A201206120309Tube · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE FIRE EXTINGUISHER LINE FORWARD OF SPAR 3 FOR RIGHT ENGINE HAS CORROSION. MAINTENANCE REMOVED AND REPLACED FIRE EXTINGUISHER LINE FORWARD ON SPAR 3 FOR RIGHT ENGINE IAW EMB 175 AMM 20-10-13. THE AIRCRAFTSDR USAA2012061100028Fire Bottle · depletedLAV "A" FIRE BOTTLE INDICATOR SHOWED ZERO PRESSURE. UPON REMOVAL VERIFIED BOTTLE WAS EMPTY BY WEIGHT. REPLACED LAV "A" FIRE BOTTLE IAW AIRBUS MAINTENANCE MANUAL 26-25-41-401.SDR REXA2012061000826Extinguisher · lowCARGO BOTTLE LOW CAUTION MESSAGE IN FLIGHT, EXTINGUISHED JUST BEFORE LANDING. REMOVED AND REPLACED LT, RT CARGO FIRE BOTTLE IAW AMM 26-25-01. OPS CHECKED GOOD. OK FOR SERVICE.SDR MASA2012061134870Extinguisher · dischargedLOW PRESSURE CARGO FIRE BOTTLE DISCHARGED. REMOVED AND REPLACED FIRE EXTINGUISHER CONTAINER. OPS CHECKED NORMAL.SDR MASA2012061134869Extinguisher · dischargedHIGH PRESSURE CARGO FIRE BOTTLE DISCHARGED. REMOVED AND REPLACED FIRE EXTINGUISHER CONTAINER. OPS CHECKED NORMAL.SDR USAA2012052100026Extinguisher · depletedFORWARD LAV TRASH CAN FIRE EXTINGUISHER BOTTLE EMPTY. REMOVED AND REPLACED FIRE EXTINGUISHER BOTTLE AS REQUIRED.SDR ASOA201201462Switch · unserviceableLEFT ENGINE BOTTLE NOT ARMING DURING FIRST FLIGHT OF DAY FIRE WARNING TEST PUSH TO DISCHARGE LIGHT DOESN'T LIGHT UP. CLEANED PBA FOR PUSH LIGHT LT AND RT PUSH TO DISCHARGE SWITCH, INSTALLED A NEW SWITCH ASSY IAW ESPM 20-24-00. OPS CHECK GOOD. (SDR CLOSED)SDR USAA2012022700017Fire Bottle · low pressureMID LAV FIRE EXTINGUISHER BOTTLE GAUGE SHOWING RED. REPLACED MID LAV TRASH BIN FIRE EXTINGUISHER BOTTLE IAW AIRBUS MAINTENANCE MANUAL 26-25-41-401.SDR USAA2012022000024Fire Bottle · lowLAVATORY C TRASH CAN FIRE BOTTLE LOW. REMOVED AND REPLACED LAV C TRASH CAN FIRE BOTTLE IAW AIRBUS MAINTENANCE MANUAL 26-25-41.SDR FDEA201202160599Fire Bottle · dischargedLIGHTNING STRIKE DURING CLIMB. NOSE CONE AREA. COMPLIED WITH LIGHTNING STRIKE INSPECTION IAW AMM 05-53-01-6-0. ENGINE FIRE AGENT LOW LIGHT (NR1) AFTER LIGHTNING STRIKE. DURING CLIMB, ENGINE INDICATIONS REMAINED NORMAL. COMPLIED WITH LIGHTNING STRIKE INSPSDR 2012FA0000112Fire Bottle · leakingNEW FIRE BOTTLE DESIGN FROM MFG WAS INSTALLED A MONTH AGO AND WAS SUPPOSED TO BE A NEWLY DESIGNED EXTINGUISHING CARTRIDGE NOT TO LEAK LIKE THE OLDER STYLE BOTTLES. THE BOTTLE WAS FOUND TO HAVE LEAKED OUT INSIDE THE PYLON AREA. THIS CHEMICAL IS EXTREMELY CORROSSDR UALA2012020900776Fire Bottle · dischargedLAV 'F' FIRE EXTINGUISHER SYSTEM - SMOKE. CREW COMMENTS: DISCHARGED. :MX FOUND THE FIRE BOTTLE IN THE RED BAND, LAV INOP IAW MEL PLACARD 2617M. ^06FEB OPB CQT- :ACCMP'D CHK OF LAV 'F' SMOKE DET SYSTEM. FOUND SMOKE DET SYS OPS NORMAL. LAV IS USEABLE PER MEL SDR FDEA201201120135Fire Bottle · inoperativeALERTED TO "ENG FIRE ALERT LO" ON NR 1 ENGINE. POSSIBLY COINCEDENTAL, BUT ALERT OCCURED WITHIN 10 SECONDS OF STATIC DISCHARGE/LIGHTNING STRIKE. REMOVED AND REPLACED NR 1 FIRE BOTTLES IAW AMM 26-21-01-4, OPS CHECKED IAW AMM 26-21-01-5, INSTALLED NEW FIREX DSDR NOCA12411Fire Bottle · dischargedDURING TROUBLESHOOTING APU FIRE BOTTLE DISCHARGED. REASON FOR DISCHARGE UNKNOWN. ASSIGNED CI 26-06. REMOVED AND REPLACED APU FIRE BOTTLE PER TASK 26-22-02 TEST CHECKS NORMAL.SDR USAA2011121300007Extinguisher · low pressureFORWARD LAV TRASH CAN FIRE EXTINGUISHER BOTTLE GAUGE SHOWS EMPTY. REMOVED AND REPLACED FORWARD LAV TRASH CAN FIRE EXTINGUISHER IAW AIRBUS MAINTENANCE MANUAL 26-25-41-400-001 AND 26-25-41-000-001.SDR CALA2011112100754Fire Bottle · leakingEN ROUTE THE FIRE EX-SEAL BROKE AND DISCHARGED (COCKPIT BOTTLE). REMOVED AND REPLACED COCKPIT HALON FIRE EXTINGUISHER. OK TO CONTINUE.SDR MASA2011111464024Fire Bottle · dischargedE1 FIRE BOTTLE DISCHARGED. REPLACED FIRE BOTTLE.SDR UALA2011110906126Squib · faultyDURING TEST ON JOB8-8401 FIRE EXT BOTTLE SQUIB CHECK, ON STEP 12 TEST2 ENG 4 SQUIB LIGHT DID NOT COME ON. REPLACED NR 4, SYS 'B' SQUIB PER MM.SDR SIMA2011313008Fire Bottle · inoperativeDURING MAINTENANCE INSPECTION FOUND THE BAGGAGE FIRE BOTTLE INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERIVCE. REMOVED AND REPLACED THE BAGGAGE HIGH RATE FIRE BOTTLE IAW AMM 26-23-01. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA201131203Fire Bottle · low pressureON FLIGHT 3820 THE CREW RECEIVED A MESSAGE THAT THE CARGO FIRE EXTINGUISHER BOTTLE WAS LOW. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE CARGO FIRE EXTINGUISHER BOTTLE IAW CRJ 700 AMM 26-25-01-000-801-A01 PERFORMED OPERATIONAL CHECK IAW CRSDR UALA2011101905657Extinguisher · dischargedAFT FIRE EXTINGUISHER AGENT LEVEL LOW. REMOVED AFT HALON BOTTLE.SDR EIAA2011235Squib · no testDURING PREFLIGHT FLIGHT, ENGINEER DISCOVERED FIRE BOTTLE SQUIB 3B WOULD NOT TEST. REMOVED AND REPLACED 3B FIRE BOTTLE SQUIB.SDR UALA2011092805240Guard · improper partCARGO FIRE BOTTLE SWITCH GUARD IS INCORRECT, EVA NO LONGER APPLIES, THE NR 2 GUARD NEEDS TO BE REPLACED. REPLACED GUARD.SDR UALA2011092605194Wire · damagedON TEST SQUIB 1 ON ENG 1 DOES NOT TEST. REPAIRED WIRE 451219DL20 ON SQUIB CONNECTOR 5WE1 IAW ESPM AND PERFORMED OPERATIONAL TEST IAW AMM, TEST OKAY.SDR EIAA2011223Tube · misinstalledNR 3 ENG RT FIRE BOTTLE FAILED TO DISCHARGE DURING ENG FIRE. REPLACED NR 3 ENGINE LT AND RT FIRE BOTTLES, OPS GOOD, SQUIB TEST OK PER MM 26-21-03. THE RIGHT FIRE BOTTLE DISCHARGE TUBE WAS FOUND TO HAVE BEEN INSTALLED WITH ONLY 3/4 OF A THREAD ENGAGED AND HANSDR TRBAWarning Light · malfunctionedTHE AGENT 2 DISCHARGE LIGHT IS ILUMINATED ON FIRE DETECTION 1 AND AGENT 1 IS ON SYS 2. OPS CHECKED SYS GOOD REF AMM 26-12-00, OPT 10000.SDR UALA2011082504557Fire Bottle · dischargedAPU FIRE BOTTLE DISCHARGED. FIRE BOTTLE ACCIDENTALLY DISCHARGED WHILE REPLACING APU FIRE LOOP. NEED FIRE BOTTLE AND SQUIBS REPLACED. NOT AVAILABLE AT LAX. APU IS INOP. REPLACED APU FIRE BOTTLE AND SQUIB PER AMM, OPS CHECKS OKAY FOR SERVICE.SDR AALA20110818DFW07Fire Bottle · dischargedAPU FIRE EXTINGUISHING BOTTLE DISCHARGED WHEN PERFORMING PRESSURE SWITCH OPERATIONAL TEST. REPLACED AUXILIARY POWER UNIT FIRE EXTINGUISHING BOTTLE.SDR WRLA20110806498Fire Bottle · brokenAPU FIREX BOTTLE INADVERTENLY FIRED AT A-6 CHECK. DISCHARGE HEAD AT BOTTLE BROKE RELEASING AGENT INTO AFT ASSY COMPARTMENT NOT TO APU DISCHARGE TUBES AC TT 64151:56 TC 12530.SDR A6WA201140736Fire Bottle · low"CARGO BLT LOW" MESSAGE - RETURN TO DEPARTURE. R & R LT CARGO FIRE BOTTLE IAW 26-25-20. CHECKED GOOD. REMOVED PLACARD AND MEL.SDR SIMA201120105Fire Bottle · unsecureON FLIGHT 4078 THE CREW REPORTED THE LAVATORY FIRE EXTINGUSHER CONTENTS SHOWED TO BE IN THE RED ZONE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LAVATORY FIRE EXTINGUISHER IAW EMB-145 AMM 26-25-01. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR REXA201100436Fire Bottle · low pressureAIR RETURN FOR CARGO FIRE BOTTLE LOW CAUTION MESSAGE. MESSAGE POSTED WHILE CLIMBING THROUGH FL250. CREW DID NOT DECLARE EMERGENCY. MAINTENANCE REMOVED AND REPLACED BOTH CARGO FIRE BOTTLES IAW CRJ AMM 26-25-01, OPS CHECKS GOOD REF TL-203109-2011.
Back to JASC 2621