JASC 2621
Service difficulty reports · 623
Reports filed under 2621 · Fire Bottle, Fixed, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA01751Fire Bottle · failedNEWLY REPLACED AFT DUMP FIRE BOTTLE FAILED TEST. REPLACED DUMP BOTTLE. AC OK FORE SERVICE.SDR SWIA200819395Extinguisher · dischargedRIGHT ENGINE FIRE BOTTLE DISCHARGED. REPLACED FIRE BOTTLE IAW CRJ 200 MM 26-21-07.
SDR SWIA200819378Extinguisher · low pressureFLT 6151 - RECEIVED AN "ENG BOT LO 1" EICAS CAUTION MESSAGE. REPLACED LEFT ENGINE FIRE BOTTLE IAW CRJ 700 MM 26-21-07. MESSAGE EXTINGUISHED.
SDR 2008UALA01478Bottle · faultyAPU BOTTLE DISCHARGE LIGHT ILLUMINATED. AFTER TROUBLE SHOOTING SYSTEM FOUND FIRE EXTINGUISHING BOTTLE FAULTY. REPLACED APU FIRE EXTINGUISHING BOTTLE IAW MM 26-22-11. AC OK FOR SERVICE.SDR 2008UALA01301Fire Bottle · blownNR 1 ENG NR 1 BOTTLE INADVERTENTLY BLOWN DURING HMV VISIT. ACCIDENTAL DEPLOYMENT OF FIRE BOTTLE. REPLACED BOTTLE AND CLEANED AREA.SDR WGEA200800035Fire Bottle · leakingRIGHT ENGINE FIRE BOTTLE LEAKING. REMOVED ENGINE COWLINGS AND PYLON PANELS, RIGHT SIDE FOR ACCESS. REMOVED RIGHT FIRE BOTTLE IAW EA500 AMM 26-20-10. INSTALLED A NEW RIGHT ENGINE FIRE BOTTLE IAW EA500 AMM 26-20-10. RE INSTALLED ENGINE COWLINGS AND PYLON PANSDR 2008UALA00978Light · looseNR 2 CARGO FIRE BOTTLE DISCHARGE LIGHT INOP. INDICATOR LIGHT LOOSE. SECURED LIGHT ASSY, GROUND CHECKS OK.SDR FDKA200802066Warning Message · activatedFDM 6177 PNS. BAG EXTINGUISH BOTTLE MESSAGE IN FLIGHT. MX INSPECTED AND OPS GOOD.SDR WGEA200800029Fire Bottle · leakingNR 2 ENGINE FIRE BOTTLE IS LEAKING, IT WAS LEAKING WHEN DISCONNECTED FOR 300 HOUR, NO EXTERNAL LEAK ON ENGINE. REMOVED AND REPLACED WITH NEW RIGHT PHOSTREX BOTTLE IAW EA500 AMM 26-20-10. INSPECTED ENGINE AND UPPER AND LOWER COWL FOR ANY PHOSTREX RESIDUE AND SDR 2008UALA00296Extinguisher · low pressureTHREE SVC CHECK FOUND 18GH DOGHOUSE HALON 1211 FIRE EXTINGUISHER PRESSURE LOW. REPLACED HALON EXTINGUISHER. AC OK FOR SERVICE.SDR WGEA200800004Cartridge · leakingLT ENGINE FIRE EXTINGUISHER CARTRIDGE PRESSURE IN RED BAND. EVIDENCE OF LEAKAGE INSIDE COWLINGS AND ON NUMEROUS PARTS OF THE ENGINE. SUPPLEMENTAL INFORMATION- REMOVED AND REPLACED LT ENGINE PYLON FIRE EXTINGUISHER CARTRIDGE IAW MM 26-20-00 REV NR 11 FIRE SUPPRSDR 2008UALA00056Light · inoperativePER CREW, FIRE BOTTLE SQUIB TEST LIGHT DOES NOT ILLUMINATE. REPLACED CAP ASSY AS PRECAUTIONARY. TEST NORMAL. ENGINE DISCHARGE LIGHT ON PEDESTAL DOES NOT NORMALLY WORK WITH FIRE WARNING TEST.SDR 2007UALA05382Squib · faultyFIRE SQUIB PANEL LIGHT FAILS TO ILLUM TEST SW 1 ENG 4. REPLACED BOTTLE A SQUIB REF MM26 -21-04 TEST OK. AC OK FOR SERVICE.SDR 2007UALA05280Squib · failedCARGO FIRE EXT SYS TEST FAILED. REPLACED SQUIB, BOTTLE B FWD SQUIB. PER MM26-23-02.SQUIB TEST NORMAL. AC OK FOR SERVICE.
SDR 2007UALA05232Switch · inoperativeNR 2 CARGO FIRE BOTTLE DISCHARGE LIGHT IS BURNED OUT. REPLACED NR 2 CARGO FIRE SWITCH ASSY. OPS CHECKED NORMALLY.
SDR SWIA200718958Printed Ckt Board · faultyFLT 6435 - RECEIVED A "CARGO BOTTLE LO" CAUTION MESSAGE. REPLACED PCB NR 2 IN JB2 AND PCB NR 2 IN JB3 AS WELL AS BOTH AFT AND FORWARD CARGO BOTTLES PER AMM 26-25-01, PN 446518-1, SN/OFF 12097, PN 446518-1 SN/OFF 12000, PN 473919-1, SN/OFF 0499A PN 473920-1, SSDR C2XA07ON037Extinguisher · dischargedFLT 7756 - LAX TO LAX - DURING GROUND HANDLING BY TOWING CREW BOTH BAGGAGE FIRE BOTTLES WERE DISCHARGED. MX AT LAX REMOVED AND REPLACED BOTH FIRE BOTTLE AND AIRCRAFT WAS RETURN FOR SERVICE IN AIRWORTHY CONDITIONS.SDR 2007UALA04733Fire Bottle · reads lowAPU FIRE BOTTLE PRESSURE LOW.
SDR 2007UALA04421Metering Valve · leakingCARGO FIRE BOTTLE 2 ARMED LIGHT INOP WITH BOTH BITE AND LIGHTS TEST. FOUND LEAKING SQUIB. REPLACED FIRE BOTTLE AND METERING VALVE. NO LEAKS, NO REPEATS.SDR 2007UALA04404Fire Bottle · low pressureFWD ENGINE FIRE BOTTLE PRESSURE AT LIMIT. REPLACED BOTTLE OF FWD ENG SYS.
SDR UALA08111304351AModule · faultyNR 2 FIRE HANDLE DOES NOT ILLUMINATE DURING FIRE TEST. *S/D* NR 2 ENG FIRE TEST INOP BOTH "A" AND "B" TEST FAIL. FOUND TERM LUG (CORE B-LOOP) UPPER RT BAD, REPLACED SAME. CTR CORE OF DET TO SHELL, A RES INFINITE, B 20 MEG, SHOULD BE MIN OF 40 MEG, REPLACEDSDR AALA20071998Extinguisher · dischargedRDU INFLIGHT T1256/20OCT MIA TO LGA - CARGO FIRE EXTINGUISHER DISCHARGE LIGHT ILLUMINATED IN FLIGHT. REPLACED CARGO COMPARTMENT FIRE EXTINGUISHER BOTTLE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2007UALA04160Extinguisher · low pressureRT WING "B" EXTINGUISHER BOTTLE LOW PRESS LIGHT ON, VERIFIED BOTTLE LOW. REPLACED "B" EXTINGUISHER BOTTLE (RT WING) AND RELATED SQUIBS. REF. MM 26-21-03 AC OK FOR SERVICE.
SDR FDKA200710530Grommet · tornFDM 6053 TPA (0341 PHX LCL) - NR 2 ENGINE FIRE BOTTLE T-HANDLE GROMMET TORN. MX REPAIRED.SDR SWIA200718761Fire Bottle · lowFLT 5818 - CARGO BTL LOW CAUTION MESSAGE INFLIGHT. DIVERTED TO MLI. REMOVED AND REPLACED BOTH CARGO FIRE BOTTLES IAW AMM 26-25-01.SDR VNAA0709015Fire Bottle · lowCREW REPORTED A CARGO BOTTLE LOW CAS MESSAGE IN FLIGHT. CREW ELECTED TO DIVERT AND LAND IN LYH WITHOUT INCIDENT. MAINTENANCE MEL'D THE CARGO FIRE BOTTLE PER MEL 26-25-01 -C-. AIRCRAFT WAS RELEASED FOR SERVICE.SDR 2007UALA03751Metering Valve · malfunctionedTHE 1ST BOTTLE DISCHARGE LIGHT IS ILLUMINATED ON CARGO DETECTOR SUPPRESSION PANEL. FOUND NR 1 BOTTLE DISCHARGED AND LINE PRESSURIZED TO THE DIVERTER VALVE. REPLACED NR 1 FIRE BOTTLE AND METERING VALVE. ALL TESTED NORMAL AFTER MTC.SDR 2007UALA03624Fire Bottle · dischargedDURING PANEL REPLACEMENT FOR POP SPILL FOUND 1ST BOTTLE FOR CARGO FIRE BOTTLE DISCHARGE LIGHT ON. OPENED PANEL IN FWD PIT AND FOUND BOTTLE DISCHARGED. REPLACED BOTH CARGO FIRE BOTTLES, DIVERTER VALVE, METERING VALVE, SQUIBS AND FILTERS.SDR 2007UALA03591Fire Bottle · low pressureLEFT ENGINE (FORWARD) FIRE BOTTLE LOW PSI, READS 700 PSI.SDR COMA0760556Fire Bottle · lowFLIGHT 5570 - CARGO BOTTLE LOW MESSAGE ILLUMINATED IN FLIGHT TO GSO. AIRCRAFT DIVERTED TO IAD AND LANDED SAFELY. REMOVED AND REPLACED CARGO FIRE BOTTLE.SDR A6WA200740501Fire Bottle · lowCARGO BOTTLE LOW MESSAGE. COMPLIED WITH QRH, MESSAGE CLEARED DESCENT. FIRE DEPARTMENT INSPECTION FOUND NO EVIDENCE OF HEAT. PLACED ON MEL. REMOVED AND REPLACED LT FIRE BOTTLE, OPS CHECK GOOD IAW 26-20-00 REMOVED OFF MEL.SDR VNAA0708004Fire Bottle · dischargedCREW REPORTED A CARGO BOTTLE LOW CAUTION MESSAGE ON CLIMBOUT OF CLT. CREW ELECTED TO RETURN TO CLT AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND DEFERRED THE CARGO FIRE EXTINGUISHING SYSTEM PER MEL 26-25-01. MAINTENANCE REMOVED AND REPLACED THE CARSDR 2007UALA03095Fire Bottle · dischargedFWD LAV GARBAGE CAN FIRE EXTINGUISHER BOTTLE EMPTY. 09-07-07 REPLACED FIRE BOTTLESDR 2007UALA02992Fire Bottle · dischargedAPU FIRE BOTTLE DISCHARGE LIGHT ILLUMINATED ON OVERHEAD PANEL. 09-07-07 INADVERTANT DISCHARGE ON APU FIRE BOTTLE CAUSED INDICATION. REPLACED FIRE BOTTLE AND SQUIB, RESET INDICATION.SDR 2007FA0000712Squib · groundedDURING COMPLETION OF THE INITIAL 200 HOUR PHASE 1 INSPECTION, THE RT ENGINE FIRE BOTTLE SQUIB WAS FOUND TO BE IN A GROUNDED CONDITION. THE TERMINALS WERE WIRED TOGETHER WITH SAFETY WIRE AND A TAG THAT STATED (DISCONNECT AT INSTALLATION, THE AIRCRAFT SQUIB WIRSDR CHQA200700034Extinguisher · inoperativeFLIGHT 3052 - SAV-LGA - WHILE AT FL370, THE BAGGAGE FIRE EXTINGUISHER BUTTON LIT UP, NO EICAS OR AWU WARNING/MESSAGES DISPLAYED. UPON PRESSING THE BAGGAGE FIRE EXTINGUISHER BUTTON, THE BAGG SMOKE EICAS MESSAGE APPEARED BRIEFLY THEN DISAPPEARED 15-20 SECONDS LSDR 2007UALA02450Fire Bottle · lowCREW REPORTS, THE APU FIRE EXTINGUISHER PRESSURE IS AT OR NEAR 300 PSIG (LOW). [07-27-07] REPLACED APU FIRE EXTINGUISHER BOTTLE.SDR CA070627003Squib · inoperative(CAN) WHILE PERFORMING ANOTHER MAINTENANCE TASK IT WAS DISCOVERED THAT THE LOWER (FWD) FIRE BOTTLE SQUIBS WERE NOT INSTALLED IN THE CORRECT POSITION. BOTH FIRE BOTTLES CONTAIN A SQUIB FOR THE LT AND RT ENGINES, THE LOWER NR 1 BOTTLE IS FOR THE FIRST SHOT AND SDR 2007UALA01781Extinguisher · dischargedBOTH FWD AND AFT PIT FIRE BOTTLES HAVE BEEN DISCHARGED, CONDITION FOUND UPON ARRIVAL. REMOVED AND REPLACED FWD & AFT PIT FIRE BOTTLES. ALSO, REPLACED THE METERING VALVE, DIVERTER AND FILTERS.SDR FDKA200705252Bottle · blownFDM 6127 FLL-MCO (0410 PHX LCL). CARGO BOTTLE BLOWN. MX REMOVED AND REPLACED CARGO FIRE BOTTLES.SDR C2XA07CL042Fire Bottle · intermittentCLE FLIGHT 2409 THE CREW REPORTED A BAG SMOKE DETECT INDICATION ON THE ECIAS, ALSO A BAG FIRE BOTTLE FAIL MESSAGE. THE AIRCRAFT DIVERTED TO CLEVELAND AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE BAG FIRE BOTTLES. OPERATIONAL CHECKS WESDR 2007UALA01384Bottle · no testON PREFLT, THE CARGO FIRE EXT BOTTLE 1 AND 2 ARMED LIGHTS DON`T COME ON WHEN PANEL TESTED OR WHEN CARGO PIT ARMED SW IS PLACED IN FWD OR AFT CARGO POSITIONS. REPLACED 1 AND 2 CARGO BOTTLES, DIVERTER VALVE, FILTERS AND METERING VALVE.REF.SDR MASA200700176Extinguisher · lowASH 7110 ORD - APU BOTTLE LOW CAUTION MESSAGE AND APU SQUIB CAUTION MESSAGE. MX DEFERED THE APU FIRE EXTINGUISHING SYSTEM AND APU.SDR SIMA200707803Guard · failedON LANDING ROLL OUT, CREW PUSH LEFT FIRE ARM PBA, LEFT ENGINE SHUT DOWN. REMOVED AND REPLACED LEFT FIRE PUSH BUTTON LIGHT GUARD IAW CRJ AMM 31-14-01. OPERATIONAL CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR 2007UALA00727Squib · faultyAFT CARGO FIRE BOTTLE A FWD SQUIB TEST BAD. REPLACED SQUIB AND TESTED PER MMOV 26-23-02 . TESTED OK FOR SERVICE. SUSPECT INTERNAL DETERIORATION OF SQUIB.SDR 2007UALA00675Extinguisher · misinstalledNR 1 ENGINE FWD FIRE EXTINGUISHER BOTTLE SAFETY RELIEF VALVE FOUND WITH A METAL CAP STILL INSTALLED. [SUP 05-27-07] REMOVED METAL CAP AND REINSTALLED FIRE EXTINGUISHER BOTTLE. AT THE PREVIOUS C-CHECK ON 9/13/2005, THE NR 1 ENGINE FWD BOTTLE WAS ACCIDENTALLY SDR 2007UALA00251Fire Bottle · obstructedNR 2 ENGINE FIREX DISCHARGE LINE 4 EA OPENINGS ALL CAPPED WITH FLEX HOSE AND PLUG TEST EQUIPMENT. FIREX LINE IS DIRECTLY ABOVE ENGINE FAN CASE. TEST EQUIPMENT WAS FOUND DURING OPEN UP. [SUP 05-16-07] THE INSTALLED CAPS, FLEX HOSE AND TEST EQUIPMENT ARE USESDR COMA0660715Fire Bottle · dischargedFLIGHT 5249 - CARGO BOTTLE LOW MESSAGE RECEIVED INFLIGHT. DECLARED EMERGENCY AND LANDED CVG WITHOUT INCIDENT. REPLACED BOTH CARGO FIRE BOTTLES. NO FURTHER DEFECTS.SDR AALA20061159Fire Bottle · inoperativeDFW - AFT CARGO FIRE WARNING LIGHT ILLUMINATED AND AURAL WARNING SOUNDED. DISCHARGED BOTTLE NUMBER ONE. AFTER 15 MINUTES DISCHARGED BOTTLE NUMBER 2. PRESSING TEST BUTTON PRIOR TO DISCHARGE TURNED ON FAULT LIGHT. NO OTHER INDICATION OF FIRE. LANDED DFW WITSDR A6WA200640385Fire Bottle · dischargedDURING SERVICE CHECK, FOUND ENGINE FIRE BOTTLES NR 1 AND NR 2 DISCHARGED. REMOVED AND REPLACED FIRE BOTTLES NR 1 AND NR 2 IAW CRJ 26-21-07. OPS CHECK GOOD. (K)
Back to JASC 2621