JASC 2622
Service difficulty reports · 355
Reports filed under 2622 · Fire Bottle, Portable, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2622' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2622' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM90030897Extinguisher · leakingFD POSITION H2O PORTABLE FIRE EXTINGUISHER LEAKING FLUID. DAL LEAD SEAL INTACT WITH NO EVIDENCE OF ACTIVATION OR TAMPERING. CARTRIDGE CKS OK. REPLACED SAME.SDR AMTA200300473Extinguisher · dischargedPORTABLE HALON FIRE EXTNIGUISHER FROM LEFT FORWRAD OVERHEAD BIN DISCHARGED IN FLIGHT INTO THE MIDDLE OVEN IN THE FORWARD GALLEY. DUE TO SMOKE FROM PAPER IN OVEN. REPLACED PORTABLE HALON FIRE EXTINGUISHER, LEFT FORWARD OVERHEAD, SECURED OK FOR SERVICE. NO DEFSDR CA021104007Extinguisher · loose(CAN) AT LAST FLIGHT OF THE DAY, PILOT NOTICED PRESSURE VERY LOW ON REAR CABIN HAND FIRE EXTINGUISHER AND REPORTED SNAG. UPON REMOVAL, MAINTENANCE PERSONNEL FOUND UNIT VERY LIGHT, AND PRESSURE ZERO. THE Q.A.CHECKED: BOTTLE LOOSELY UNSCREWED FROM HEAD. NOTE: SESDR AUS20021328O-Ring · failed(AUS) HAND HELD FIRE EXTINGUISHER CYLINDER TO DISCHARGE HEAD O-RING SEAL FAILED. LOSS OF FIRE EXTINGUISHING FLUID.SDR DL76G021218Fire Bottle · leakingFOUND WATER FIRE EXTINGUISHER IN FWD CABIN HAD LEAKED ALL OF THE WATER OUT. REPLACED BOTTLE.SDR KBMA115471Extinguisher · inoperativeFIRE EXTINGUISHER CHARGE DECREASED INTO RED ZONE. INSTALLED SERVICEABLE EXTINGUISHER.SDR SWIA200110041Fire Bottle · dischargedFIRE EXTINGUISHER UNDER THE FLIGHT ATTENDANT SEAT IS SHOWING EMPTY. REPLACED FIRE EXTINGUISHER UNDER THE FA'S SEAT WITH SERVICEABLE UNIT. P/N ON: 1211 S/N ON: W070425 S/N OFF: V-877583SDR AC2A072830Extinguisher · dischargedFIRE EXTINGUISHER HAD LOW WEIGHT. REPLACED WITH NEW FIRE EXTINGUISHER.SDR UPS01835706Extinguisher · leakingINSPECTION TYPE:N/A PORTABLE FIRE EXTINGUISHER LEAKING NEEDS RECHARGE. REMOVED AND REPLACED FIRE EXTINGUISHER IN COURIER AREA.SDR UPS01235092Fire Bottle · lowINSPECTION TYPE:N/A, PORTABLE CARGO COMP FIRE EXTINGUISHER BELOW LIMITS. REMOVED AND REPLACED FIRE BOTTLE.SDR 20000721SH039Extinguisher · leakingFIRE EXTINGUISHER, BELL PN 40000, TRADE NAME ''RIGHT-OUT''TM IS STANDARD EQUIPMENT FROM THE BELL FACTORY. THIS ONE LEAKED DOWN ON A FLIGHT TO THE REPAIR STATION. AIRCRAFT TT 38.8 HOURS. THE HELICOPTER WAS DELIVERED IN MAY, 2000, AT 16.0 HRS. HAPPENED DURINSDR 20000721SH014Extinguisher · leakingFIRE EXTINGUISHER, BELL PN 40000, TRADE NAME ''RIGHT-OUT'' TM, IS STANDARD EQUIPMENT FROM THE BELL FACTORY. SHIP CAME IN FOR AN ANNUAL INSPECTION. THE FIRE EXTINGUISHER WEIGHT WAS FOUND 56 GRAMS LIGHT AND UNAIRWORTHY. (X)SDR 20000817SH029Fire Bottle · dischargedINSTALLED NEW PORTABLE FIRE EXTINGUISHER IN AFT CABIN POSITION. AFTER ABOUT A WEEK IN SERVICE, THE FIRE EXTINGUISHER WAS FOUND DISCHARGED DURING A PRE-FLIGHT INSPECTION. THE FIRE EXTINGUISHER WAS REPLACED WITH A NEW UNIT, SAME PART NUMBER. THIS FIRE EXTINGUSDR 20000721SH013Extinguisher · leakingFIRE EXTINGUISHER, BELL P/N 40000, TRADE NAME ''RIGHT-OUT'' TM IS STANDARD EQUIPMENT FROM THE BELL FACTORY. THE NEW OWNER PICKED UP NEW HELICOPTER AT THE COMPLETION CENTER. ON THE FLIGHT TO HOME BASE, THE FIRE EXTINGUISER SLOWLY DISCHARGED IN-FLIGHT. ESTIMSDR CA000320034Fire Extinguisher · discharged(CAN) THE CREW REPORTED THAT THE PORTABLE FIRE EXTINGUISHER DISCHARGED SOME CHEMICAL BY ITSELF. IT WAS NOTED THE EXTINGUISHER WAS PROPERLY STORED AND PIN INSTALLED. THE EXTINGUISHER WAS SENT TO THE OVERHAUL AGENCY WHO REPORTED THE UNIT WAS IN PROPER CONDITIOSDR JBXA0000144Fire Bottle · leakingON TAXI OUT, HEARD LOUD HISS AND COCKPIT STARTED TO FILL WITH SMOKE. TURNED PACKS OFF AND SMOKE STOPPED. FOUND FLIGHT DECK FIRE EXTINGUISHER LEAKING. REMOVED AND REPLACED FLIGHT DECK FIRE EXTTIGUISHER IAW AMM 26-24-01.SDR DL757992838Extinguisher · leakingFWD H2O EXTINGUISHER USED, SEAL BROKEN. FOUND SEAL BROKEN ON H2O EXTINGUISHER AND EXTINGUISHER LEAKING. BOTTLE WAS NOT USED. REPLACED H2O EXTINGUISHER. (P/N 267701883) (S/N DL2591) OFF, (S/N DL2207).SDR HEED065798Fire Extinguish · dischargedFIRE EXTINGUISHER GAUGE INDICATES LOW CHARGE. REPLACED UNIT.SDR DL757991134Extinguisher · depletedLAV AFT LEFT H2O EXTINGUISHER USED, CONT NR C05229076. REPORTED VIA ACARS AND DISPATCHER TO MTC. F/A SUSPECTED PASSENGER SMOKING IN AFT LEFT LAVATORY AND USED H2O BOTTLE. REPLACED H2O EXTINGUISHER AND SMOKE DETECTOR.SDR 99ZZZX2132Fire Extinguish · misoverhauledOWNER/OPERATOR SENT IN A FIRE EXTINGUISHER UNIT FOR HYDROSTATIC RETEST AND OVERHAUL. AFTER THE RECEIVING PROCESS, THE UNIT WAS ROUTED TO THE PRODUCTION DEPARTMENT. AFTER UNIT HAD BEEN PROPERLY DUMPED OF ITS CONTENTS, THE TECH THEN PROCEEDED TO TEAR DOWN UNITSDR 99ZZZX1911Fire Extinguish · malfunctionedDURING RECEIVNG INSPECTION OF FIRE EXTINGUISHER, PN 895240-01, THE INSPECTOR NOTED DAMAGE TO THE MAIN OUTLET DISC. INSPECTION BY WALTER KIDDE ENGINEERING CONFIRMED A CARTRIDGE HAD BEEN FIRED, BUT FAILED TO RUPTURE DISC. THE CARTRIDGE WAS NOT AVAILABLE FOR INSDR DL757990002Fire Ext · reqd serviceFIRST CLASS HALON FIRE EXT OUT OF GREEN BAND. REPLACED HALON BOTTLE.SDR MALA976254Fire Bottle · dischargedDURING INSPECTION CREW NOTED GALLEY FIRE EXTINGUISHER DISCHARGED. MAINTENANCE REPLACED FIRE EXTINGUISHER.SDR 98ZZZX4492Nozzle · mismanufacturedRECEIVED NEW HALON 1211, 2-1/2 POUND PORTABLE FIRE EXTINGHUISHER CLASS 1-A-5B-C FROM AVIATION PARTS SUPPLY HOUSE. REPAIR STATION INCOMING INSPECTION REVEALED NOZZLE MISSING FROM FIRING HEAD. SUPPLIER WAS NOTIFIED AND THEIR ENTIRE STOCK OF THESE EXTINGHISHERSSDR 99ZZZX185Cartridge · corrodedUPON DISASSEMBLY OF THIS WALTER KIDDE FIRE EXTINGUISHER, AN OVERLAND AVIATION CARTRIDGE (P/N 1386) WAS FOUND INSTALLED. ALSO NAME PLATE (P/N 242779), TURN LABEL (P/N 211759), CAUTION AND INSTRUCTIONS DECALS DO NOT APPEAR TO BE OF ORIGINAL EQUIPMENT MANUFACTURSDR 98ZZZX2041Extinguisher · failedDURING AN ANNUAL INSPECTION, THE CABIN PORTABLE FIRE EXTINGUISHER DISTRIBUTED UNDER PIPER P/N: 459-887, FAILED WEIGHT CHECK. BOTTLE DOES NOT HAVE A PRESSURE GAUGE. SEVERAL OTHER BOTTLES HAVE BEEN FOUND IN THIS CONDITION. SUSPECT TOP/NOZZLE ASSY LOOSENS ANDSDR HEEA0013958Fire Extinguishe · defectivePRESSURE AND WEIGHT ARE LOW.SDR 97UAL900823Handle · brokenLEAD SEAL BROKEN ON WATER FIRE EXTINGUISHER. *S/D* CHARGE HANDLE WAS FOUND FROZEN OPEN WITH CORROSION. REPLACED BOTTLE.SDR VTZA97620Extinguisher · missingFLT 6371 - EWR-IAD - DURING TAXI, AIRCRAFT RETURNED TO GATE DUE TO FORWARD FIRE EXTINGUISHER MISSING RED SAFETY TAB. MAINTENANCE FERRIED AIRCRAFT TO IAD. MAINTENANCE INSPECTED AND REMOVED AND REPLACED FWD FIRE EXTINGUISHER, OPS CHECK OK. AIRCRAFT WAS RELEASSDR MALA975650Bracket · brokenFLT 3266 - ON TAXI OUT OF GATE, THE FIRE EXTINGUISHER MOUNTING BRACKET IN FLIGHT COMPARTMENT BROKE. MAINTENANCE REPLACED COCKPIT FIRE EXTINGUISHER MOUNTING BRACKET. OPS CHECK GOOD. (M)SDR CA970909009Fire Bottle · new installation(CAN) HALON TYPE FIRE EXTINGUISHER ORGINALLY INSTALLED CANNOT BE SERVICED. NEW INSTALLATION IS A 2-1/2 POUND DRY CHEMICAL EXTINGUISHER. THE NEW FIRE EXTINGUSIHER HAS A LARGER DIAMETER. IN ORDER TO CORRECTLY INSTALL THE NEW EXTINGUISHER, THE HOLDING BRACKET MSDR 97ZZZX4196Extinguisher · inoperativeFIRE EXTINGUISHER WAS RECEIVED INTO SHOP AS CONDITION UNKNOWN. NO TAG. UPON DISASSEMBLY, THE FOLLOWING DISCREPANCIES WERE NOTED, RENDERING UNIT INOPERATIVE. AGENT REMOVED NOT HALON 1301 AS SPECIFIED. ADDITIONAL COPPER DISK INSTALLED UNDER SAFETY PLUG. (PLSDR 97ZZZX4195Extinguisher · inoperativeFIRE EXTINGUISHER WAS RECEIVED INTO SHOP AS CONDITION UNKNOWN. NO TAG. UPON DISASSEMBLY, THE FOLLOWING DISCREPANCIES WERE NOTED, RENDERING UNIT INOPERATIVE. AGENT REMOVED NOT HALON 1301 AS SPECIFIED. ONLY TRACE OF AGENT IN CONTAINER. GAUGE READING 100 PSISDR 97ZZZX4194Extinguisher · inoperativeFIRE EXTINGUISHER WAS RECEIVED INTO SHOP AS CONDITION UNKNOWN. NO TAG. UPON DISASSEMBLY, THE FOLLOWING DISCREPANCIES WERE NOTED, RENDERING UNIT INOPERATIVE. AGENT REMOVED NOT HALCON 1301 AS SPECIFICED. ADDITIONAL DISK INSTALLED UNDER RUPTURED DISK, NOT O.ESDR 97ZZZX4193Extinguisher · inoperableFIRE EXTINGUISHER WAS RECEIVED INTO SHOP AS CONDITION UNKNOWN, NO TAG. UPON DISASSEMBLY, THE FOLLOWING DISCREPANCIES WERE NOTED RENDERING UNIT INOPERABLE. AGENT REMOVED NOT HALON 1301 AS SPECIFIED. ADDITIONAL COPPER DISK INSTALLED UNDER RUPTURED DISK, NOT OSDR DLM11971415Fire Bottle · low pressFIRE EXTINGUISHER BOTTLE AT 4L LOW PRESS. REPL BOTTLE.SDR 97ZZZX2896Extinguisher · defectiveFIRE EXTINGUISHER RECEIVED FOR OVERHAUL. WHEN A FUNCTIONAL TEST WAS PERFORMED PRIOR TO OVERHAUL, A STRANGE VIBRATION OR THUMP WAS FELT WHEN THE CO2 CARTRIDGE WAS DISCARDED INTO THE EXTINGUISHER. WHEN THE DISCHARGE LEVER WAS PUSHED, NO EXTINGUISHING AGENT WASSDR CA970603021Extinguisher · failed(CAN) PASSENGER DEPOSITED LIT CIGARETTE INTO WASHROOM WASTE BIN CAUSING A MINI FIRE. FIRE EXTINGUISHED AND BIN EMPTIED. CONTINENTAL MAINTENANCE PERSONNEL CALLED TO INSPECT WASHROOM WASTE BIN CONTAINER. BIN EMPTIED AND EXTINGUISHED WITH WATER. WASTE BIN FIRE EXSDR AU970591Extinguisher · faulty(AUS) FITMENT OF FIRE EXTINGUISHER NOT ENTERED IN LOG BOOKSSDR AU971112Extinguisher · wrong part(AUS) UNAPPROVED TYPE OF DRY POWDER FIRE EXTINGUISHER FITTED. UNAPPROVED PART.SDR 9708365505Fire Ext · activatedDURING CRUISE FLIGHT, SMOKE WAS REPORTED IN THE TRASH CAN AT LAV 3L. FIRE WAS PUT OUT WITH A PORTABLE WATER FIRE EXTINGUISHER. ON INSPECTION OF LAV 3L, NO INDICATION OF FIRE WAS NOTED. OVERHEAT TEMPERATURE INDICATOR CHECKED OK, NO SMOKE MARKS WERE FOUND IN SDR DLM11962557Fire Bottle · low chargeHALON FIRE BOTTLE AT 4L IS LOW.SDR C2XA96IA208Fire Bottle · under weightIAH - DURING C-CHECK INSPECTION, THE TOILET TRASH COMPARTMENT FIRE BOTTLE WAS FOUND TO BE UNDER WEIGHT. MAINTENANCE REMOVED AND REPLACED THE FIRE BOTTLE, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR HEEA967368Extinguisher · defectiveEXTINGUISHER LABEL NOT LEGIBLE.SDR DLL13960845Halon Fire Bott · dischargedHALON FIRE BOTTLE ON CAPTS SIDE, USED IN LOWER GALLEY, SMALL FOOD TRAY FIRE. REPLACED HALON BOTTLE, INSPECTED OVENS AND ALL CHECK NORMAL. SUSPECT PART OF FOOD WRAPPER INADVERTENLY LEFT ON TRAY.SDR DL757960618Fire Bottle · low pressFIRST CLASS HALON FIRE EXTIGUISHER HAS LOW PRESSURE. REPLACED BOTTLE.SDR COMA9630061Fire Ext · corrodedCABIN FIRE EXTINGUISHER HANDLE IS HARD TO ROTATE. CLEANED AND REASSEMBLED FIRE EXTINGUISHER AND RETURNED TO SERVICE. PART TOTAL CYCLES, 22,156.SDR DL757960271Fire Bottle · emptyDURING LAYOVER, FOUND FWD CABIN HALO FIRE BOTTLE EMPTY. REPLACED BOTTLE.SDR USAASB96014Extinguisher · leakingFLT NR 1974 - CLT - AFT WATER FIRE EXTINGUISHER SEAL MISSING AND IS LEAKING. MAINTENANCE REPLACED EXTINGUISHER. (M)SDR DL757960028Fire Bottle · leakingF/C HALON FIRE BOTTLE LEAKING EXTINGUISHING AGENT.
Back to JASC 2622