SDR UALA2009051801394Extinguisher · out of toleranceAFT LAV NR 136 FIRE EXT NEEDLE NOT IN GREEN. LAV INOP. DOOR LOCKED CLOSED. EXTINGUISHER REPLACED BY BA24320A1.SDR UALA2009013000329Extinguisher · leakingDOOR 4R WATER EXTINGUISHER HAS EVIDENCE OF LEAKING. CLEANED DOGHOUSE STORAGE AND REPLACED EXT.SDR UALA2009012600264Extinguisher · leakingFWD GALLEY WATER FIRE EXT LEAKING. REPLACED WATER FIRE EXTINGUISHER.SDR UALA2009010900089Bracket · bentFIRE EXT IN ROW 26ABC WILL NOT REMAIN IN BRACKET AND IS LOOSE ON FLOOR. BRACKET APPEARS BENT. SECURED FIRE BOTTLE.SDR UALA2009010500034Extinguisher · unserviceableREPLACED FIRE EXT ROW 24.SDR MASA2008111400772Bracket · brokenASH FLT 7211 ORD-EWR. AFT FIRE EXTINGUISHER HOLDER BROKEN. MX RE-SECURED THE FIRE EXTINGUISHER TO THE BRACKET.SDR 2008UALA06248Fire Bottle · unsecureAFT LAV WALL FIRE EXTINGUISHER FELL OUT OF BRACKET. SECURED BOTTLE.SDR 2008UALA03875Safety Wire · missingCREW REPORT: WATER EXTINGUISHER DOES NOT HAVE SAFETY WIRE. *S/D* FOUND SEAL BROKEN. REPLACED FIRE EXTINGUISHER. AC OK FOR SERVICE.SDR SWIA200819781Extinguisher · dischargedLAVATORY TRASH FIRE EXTINGUISHING BOTTLE IS DISCHARGED. (FLT 2778) REMOVED AND REPLACED THE LAVATORY TRASH FIRE BOTTLE AS NEEDED PER MM 26-26-01.SDR 2008UALA02459Relay · failedAPU FIRE EXTINGUISHING CIRCUIT CHECK FAILS. FOUND FLIGHT GROUND RELAY 43WF FAILING. FLIGHT GROUND RELAY 43WF REPLACED, OPS TESTED SYSTEM NORMAL.SDR 2008UALA01842Extinguisher · dislodgedREINSTALL COCKPIT FIRE EXTINGUISHER FELL OFF BRACKET. REINSTALLED BOTTLE IN HANGER ASSY. AC OK FOR SERVICESDR 2008UALA01811Seal · brokenFA REPORTED DOOR 4R WATER FIRE EXTINGUISHER SEAL BROKEN.SDR 2008UALA01672Extinguisher · faultyTRASH CAN EXTINGUISHER AT LAV 4R DISCHARGED WITH NO SIGN OF FIRE.SDR HALA0800426Bottle · dischargedON OVERNIGHT CK, FOUND PORTABLE FIREX AT R2 DOOR, EQUIP NR E48, WITH NEEDLE IN THE RECHARGE BAND. REMOVED AND REPLACED AFT RT PORTABLE FIRE EXTINGUISHER.
SDR 2008UALA00971Fire Bottle · malfunctionedDURING 3SVC CHECK FOUND CARGO FIRE SYSTEM 1ST BOTTLE DISCHARGE LIGHT ON. REPLACED NR 1 CARGO FIRE BOTTLE PER MM 26-23-01 AND GROUND CHECKED OK. REPLACED DUCT ASSY AND LEAK CHECKED GOOD. ACFT OK FOR SERVICE.SDR 2008UALA00291Extinguisher · leakingWATER FIRE EXTINGUISHER LEAKING FLUID. SUSPECT FAULTY EXTINGUISHING RELEASE VALVE. REPLACED AFT WATER FIRE EXTINGUISHER. ACFT OK FOR SERVICE.SDR 2007UALA05175Extinguisher · low pressureFWD GALLEY HALON FIRE EXTINGUISHER PRESSURE APPEARS LOW. REPLACED HALON EXTINGUISHER IN FWD GALLEY.SDR MASA200700718Extinguisher · dischargedASH FLT 7400 HSV-IAD, LAV FIRE EXTINGUISHER HAD NO CHARGE. REMOVED AND REPLACED FIRE EXTINGUISHER.SDR 2007UALA04336Extinguisher · leakingHALON FIRE EXTINGUSHER STARTED LEAKING IN COCKPIT. SUSPECT FAULTY RELEASE VALVE. REPLACED COCKPIT HALON FIRE EXTINGUISHER. AC OK FOR SERVICE.SDR CA071003020Seal · failed(CAN) ON SEPTEMBER 30, 2007 THE FLIGHT CREW REPORTED THAT THE PORTABLE FLIGHT DECK FIRE EXTINGUISHER PARTIALLY DISCHARGED DURING CRUISE ON A/C 803. THE FIRE EXTINGUISHER WAS REPLACED WITH NO FURTHER ACTION REQUIRED.SDR 2007UALA03410Warning Light · illuminatedAPU BOTTLE DISCHARGE LIGHT IS ILLUMINATED. ACCOMPLISHED TROUBLESHOOTING ON ONE OF THE THREE LARGE CONNECTORS AFT LEFT SIDE OF GEAR TO CHECK FOR ANY SHORTING OF PIN 2-3; RECHECKED VOLTAGE AT SQUIB ON APU BOTTLE. THE PROGNOSIS IS ON A BAD CONNECTOR WITHSDR CA070809003Extinguisher · leaking(CAN) FLIGHT DECK FIRE EXTINGUISHER LEAKED IN CRUISE. CAPTAIN AND F/O HEARD A HISSING SOUND COMING FROM THE FIRE EXTINGUISHER BEHIND AND LEFT OF THE F/O. CAPTAIN AND F/O DONNED O2 AND ASSESSED THE SITUATION IE; FEELING THE LEAK NEAR THE EXTINGUISHER`S NECK. SDR 2007UALA02887Extinguisher · reads lowLAV F FIRE EXTINGUISHER SYSTEM, SMOKE. CHECKED DETECTOR-OK, REPLACED LAV FIREXT.SDR 2007UALA02809Extinguisher · reads lowFIRE EXTINGUISHER PSI IN COCKPIT LOW. LOSS OF PRESSURE IN BOTTLE (FIREXT) REPLACED HALON FIRE EXT IN COCKPIT.SDR 2007UALA02169Extinguisher · unserviceableWATER EXTINGUISHER-DOOR 1R MISSING SAFETY WIRE. [07-20-07] REPLACED EXTINGUISHER WITH SERVICABLE ONE. AIRCRAFT OK FOR RETURN TO SERVICE.SUSPECT SAFETY WIRE SNAGGED BY PASSENGER SERVICE EQUIPMENT AND BROKEN OFF.SDR 2007UALA01973Extinguisher · low pressureCOCKPIT FIRE EXTINGUISHER BELOW GREEN BAND. REPLACED THE FLIGHT DECK FIRE EXTINGUISHER.SDR CA070809004Extinguisher · failed(CAN) FOUND A FLIGHT DECK FIRE EXTINGUISHER THAT WAS REMOVED FROM THE AIRPLANE FOR LOSS OF PRESSURE. BOTTLE WAS FOUND COMPLETELY EMPTY AND THE TOP WAS LOOSE. YOU COULD SPIN THE TOP RIGHT OFF. STRIP REPORT REQUESTED FROM REPAIR FACILITY FOR INFORMATION. THIS RESDR 2007UALA01909Extinguisher · reads lowAFT LAV FIRE EXTINGUSHER IN RED BAND. REPLACED LAV AUTO FIREX.SDR 2007UALA01218Cartridge · dischargedAFT WATER FIRE BOTTLE CO-2 CARTRIDGE FOUND EMPTY BUT BOTTLE FULL OF WATER. [06-22-07] REPLACED FIRE EXTINGUISHER ASSEMBLY.SDR NOCA08307Fire Bottle · dischargedAPU FIRE BOTTLE ACCIDENTALLY DISCHARGED IN LEJ. REMOVED AND REPLACED APU FIRE BOTTLE IAW AMM 26-22-02. SYSTEM CHECKS NORMAL.SDR 2006UALA01742O-Ring · leakingCOCKPIT HALON FIRE EXTINGUISHER DISCHARGED THROUGH THE RUBBER O-RING MOUNTED BETWEEN THE DISCHARGE HANDLE AND BOTTLE WHILE SAFETY PIN REMAINED INSTALLED. GAUGE READS FULL AND THE NEEDLE REMAINS IN GREEN BAND BUT BOTTLE CONFIRMED EMPTY. O-RING FOUND DISLODGEDSDR 2006UALA01698Extinguisher · leakingCOCKPIT HALON FIRE EXTINGUISHER STARTED LEAKING AT SEAL ON TOP. BOTTLE NOW MOSTLY EMPTY. REPLACED COCKPIT HALON FIRE EXTINGUISHER BOTTLE.SDR UPS06247313Extinguisher · unserviceableMAIN PORTABLE FIRE EXTINGUISHER NEEDLE IS OUT OF GRN BAND. REMOVED AND REPLACED PORTABLE FIRE EXTINGUISHER BY LAV DOOR. OK FOR SERVICE.SDR CA060608008Extinguisher · leakingTHE A/C WAS AT CRUISE WHEN A HISSING SOUND WAS HEARD. IT WAS DETERMINED TO BE LEAKAGE FROM THE PORTABLE FIRE EXTINGUISHER IN THE FLIGHT DECK. THE HISS CHANGED TO A LOUD WHISTLE AS IT INCREASED. THE CAPTAIN GRABBED THE TOP OF THE EXTINGUISHER AND TWISTED IT SDR 2006FA0000716Extinguisher · explodedA NEW 1.25 LB EXTINGUISHER MODEL 344, SN W-968052 CLASSIFICATION 2-B; C WAS INSTALLED IN THE AIRCRAFT ON MARCH 6, 2006. IT WAS REMOVED OVERNIGHT AND REINSTALLED AT 8:50 AM ON MARCH 7, 2006. AS THE HELICOPTER WAS STARTING, THE END EXPLODED OUT OF THE EXTINGUISDR AWXA200600204Extinguisher · emptyPHX - EMERGENCY EQUIPMENT, CREW REPORTED THAT THE LAV D FIRE EXTINGUISHER WAS FOUND EMPTY; THE INDICATOR WAS IN THE RED BAND. MAINTENANCE INSPECTED AND FOUND NO SIGN OF DISCHARGE. REMOVED AND REPLACED THE LAV D FIRE EXTINGUISHER.SDR 2005FA0001528Extinguisher · incorrectREMOVING HAND HELD FIRE EXTINGUISHER FROM THE COCKPIT FOR ROUTINE INSPECTION IT WAS NOTED THAT THE HANDLE DID NOT APPEAR TO BE CORRECT. FURTHER INSPECTION SHOWED THAT THERE ARE TABS ON THE LOWER HANDLE THAT WOULD HAVE PREVENTED THE EXTINGUISHER FROM DISCHARGISDR MALA050817Extinguisher · brokenDURING INSPECTION, FOUND LAV FIRE EXTINGUISHER BROKEN AND DISCHARGED. INSTALLED NEW FIRE EXTINGUISHER IN LAV POSITION IAW SF 340 AMM CH 26 AS REQUIRED.SDR F05006Seal · missingTHE CREW REPORTED FWD CABIN FIRE EXTINGUISHER SEAL MISSING. MAINTENANCE REPLACED THE FIRE EXTINGUISHER.SDR 09212005AFire Bottle · lowCOCKPIT FIRE EXTINGUISHER PRESSURE IS INDICATING LOW. REMOVED AND REPLACED COCKPIT FIRE EXTINGUISHER.SDR 2005FA0000846Fire Bottle · dischargedTHIS FIRE BOTTLE HAS 1 YEAR ON IT AND THE PRESSURE HAS DROPED TO 20 PSI. THIS IS THE SECOND FIRE BOTTLE THAT DID NOT MAKE IT TO 5 YEARS. OVERHAULED BY KELLY AEROSPACE. (QUALITY OF WORKMANSHIP AND OR PARTS)? THIS NEVER HAS BEEN A PROBLEM.SDR CA050524001Extinguisher · leakingENGINE FIRE EXTINGUISHER RECEIVED EMPTY FROM CUSTOMER FOR INVESTIGATION AS TO CAUSE OF DEPLETION. INSPECTION OF THE BOTTLE CONFIRMED THAT UNIT EMPTY BUT HAD NOT BEEN ACTIVATED. FOUND EXTINGUISHER LEAKING THROUGH THE TCPS VENT HOLE. EXTINGUISHER MANUFACTURED SDR DHL2005763002Extinguisher · dischargedENTRYWAY FIRE EXTINGISHER GAUGE IN THE RECHARGE ZONE. REMOVED AND REPLACED FIRE EXTINGISHER BOTTLE IAW MM 26-22-00.SDR 2005FA0000200Fire Bottle · dischargedPORTABLE FIRE EXT NOZZLE WAS FOUND TO BE LOOSE AND BOTTLE COMPLETELY DISCHARGED. REMOVED NOZZLE FROM BOTTLE AND FOUND NOZZLE AND BOTTLE THREADS CORRODED. ALSO, NOZZLE TO BOTTLE O-RING SEAL DETERIORATED. POSSIBLE CAUSE OF DEFECT COULD BE IMPROPER TORQUE VALUSDR DLM88040624Extinguisher · leakingAFT WATER FIRE EXTINGUISHER LEAKING. REPLACED SAME.SDR 2004FA0000514Fire Bottle · mismarkedDURING THE LT FIRE BOTTLE WEIGHT CHECK, THE INSPECTOR NOTICED THE COLOR OF THE CABLE MARKER TIES AND THE HEAT SHRINK SLEEVES FOR THE LT BOTTLE, DID NOT MATCH THE COLOR OF THE DECALS ON THE PLUMBING, EVEN THOUGH THE NOMENCLATURE ON THE TIES IS CORRECT. ASC WASSDR DL733040090Extinguisher · dischargedPORTABLE FIRE EXTINGUISHER PRESSURE LOW. REPLACED SAME.SDR ERAA094438Extinguisher · inoperativeUNIT HAS LOW PRESSURE, BARE METAL SHOWING, ID PLATE IS DAMAGED, WARNING LABEL IS DAMAGED, PRESSURE GUAGE IS 50 PSI OUT OF CALIBRATION. ACTION TAKEN: CLEANED, INSEPCTED, HYDROTESTED IAW CFR 49 180.205, BEAD BLAST AND PAINTED, OVERHAULED, REPLACED GUAGE, INSTALSDR AMCR200300007Extinguisher · leakingDURING BASIC INSPECTION, TECHNICIAN FOUND THE COCKPIT FIRE EXTINGUISHER PRESSURE GAUGE TO BE READING AT VERY BOTTOM OF GREEN RANGE. FURTHER INSPECTION REVEALED THE GAUGE TO BE LOOSE, AND SLIGHTLY TWISTING GAUGE CAUSED THE BOTTLE TO LEAK.SDR UPS03541349Extinguisher · mismarkedFIRE EXTINGUISHER ON FLIGHT DECK HAS NO HYDROSTATIC OR MANUFACTURE DATE. REMOVED AND REPLACED FIRE EXT.