JASC 2761
Service difficulty reports · 1,071
Reports filed under 2761 · Drag Control Actuator, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2761' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2761' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2016090655496Actuator · leakingRIGHT WING NR 8 FLIGHT SPOILER ACTUATOR LEAKED. R & R THE ACTUATOR IAW AMM.SDR SIMA20160821003Pcu · faultyINBD FLIGHT SPOILERS, INBD SPOILERONS CAUTIONS POSTED ON FINAL APPROACH. INTERROGATED MDC FOUND RT INBD MFS PCU FAILED PCU JAM. PERFORMED SPOST1 RESET, PERFORMED OPS CHECK IAW ETN-CR-27-093. OPS CHECK GOOD. OPEN TDMI 525T2761 TO R & R R-INBD MFS PCU IN 10 SDR SWAA2016082355061Rod End · brokenLEFT WING NR 4 GROUND SPOILER INBOARD ACTUATOR ROD END BROKEN. R & R NR 4 ACTUATOR IAW AMM.SDR ASMF201610008Pulley · stuckAIRCRAFT RETURNED TO PLATFORM DURING FLIGHT CONTROL CHECK, THE LEFT FLIGHT SPOILER WAS DEPLOYED PARTIALLY AFTER BOTH ENGINES START. MAINTENANCE PERSONNEL CHECKED LEFT SPOILER CONTROL SYSTEM, CABLE GUARDS, CONTROL CABLE PULLEYS AND BRACKETS IAW AMM 27-61-00/601SDR SWAA2016080254464Actuator · stuckRT WING NR 5 INBD GROUND SPOILER ACTUATOR STUCK. R & R ACTUATOR IAW AMM.SDR SWAA2016071853921Actuator · inoperativeRIGHT WING NR 9 INBD FLIGHT SPOILER ACTUATOR INOPERATIVE. R & R ACTUATOR IAW MM.SDR SWAA2016062053014Actuator · out of adjustLEFT WING NR 5 SPOILER OUT OF ADJUST. R & R ACTUATOR IAW AMM.SDR SWAA2016062153098Actuator · out of adjustRIGHT WING NR 8 FLIGHT SPOILER ACTUATOR OUT OF ADJUST. R & R ACTUATOR IAW AMM.SDR SWAA2016062153097Actuator · looseLEFT WING NR 4 SPOILER ACTUATOR LOOSE DURING OPERATION. R & R ACTUATOR IAW AMM.SDR SWAA2016051651851Actuator · leakingLEFT WING NR 3 FLIGHT SPOILER LEAKED. R & R ACTUATOR IAW MM.SDR SIMA20160506002Pcu · failedIN FLIGHT SPOILERONS CAUTION MSG. INITIAL MINOR ROLL ON DEPLOYMENT AFTER CONTROL STABILIZED. R & R LT INBD MFS PCU IAW AMM 27-62-01. OPERATIONS CHECK AND LEAK CHECKED GOOD. NO FURTHER DEFECTS NOTED.SDR AALA20160505003Actuator · faultyAIRCRAFT WAS GNDED. WHEN TOGA WAS PRESSED THE TAKEOFF CONFIGURATION WARNING LIGHT ILLUMINATED & HORN SOUNDED. TAKEOFF REJECTED AT APPROX 20 KNOTS. ACCOMPLISHED FIM TASK 27-62-00 & FOUND GND SPOILER CONTROL VLV BYPASSING. R & R VLV IAW AMM 27-62-41 & AUTO SSDR ASMF201606007Actuator · looseCAPTAIN REPORTED THAT DURING CRUISE, THE ACFT REQUIRED 4 UNITS OF COMPENSATION TO LT FOR MAINTAINING THE ACFT STRAIGHT AND LEVEL. MAINTENANCE PERSONNEL PERFORMED REVISION TO SPOILER IAW AMM 27-61-00, DETECTING THE SPOILER NR 2 SLIGHTLY RAISED; SO THE SPOILER SDR SWAA2016042251223Actuator · leakingRIGHT WING NR 6 FLIGHT SPOILER ACTUATOR EXTERNAL HYD LEAKED. R & R ACTUATOR IAW AMM.SDR SWAA2016042251222Actuator · leakingLEFT WING NR 3 FLIGHT SPOILER ACTUATOR EXTERNAL HYD LEAKED. R & R ACTUATOR IAW AMM.SDR SWAA2016042051143Actuator · leakingRIGHT WING NR 9 FLIGHT SPOILER LEAKED. R & R ACTUATOR IAW AMM.SDR SIMA20160417003Actuator · failedAFTER EXTENDING FLIGHT SPOILERS, OTBD SPOILERONS & OTBD FLIGHT SPOILERS CAUTION MSG. FLIGHT SPOILERS REMAINED EXTENDED WITH FLIGHT CONTROL LEVER RETRACTED. TRANSFERRED TO NRWC 531-ORD-01642 FROM NRWC 531-ORD-01642. R & R RT OTBD MFS SPOILER ACTUATOR IAW AMSDR SWAA2016041150784Actuator · leakingLEFT WING NR 1 GND SPOILER ACTUATOR LEAKED. R & R NR 1 GND SPOILER IAW AMM.SDR SWAA2016040150525Actuator · looseRIGHT WING NR 7 SPOILER INBD ACTUATOR LOOSE AT LOWER ATTACH POINT. R & R ACTUATOR IAW MM.SDR SWAA2016032850256Actuator · looseLEFT WING NR 4 SPOILER ACTUATOR HOUSING PIVOT LOOSE & LEAKING HYD FLUID. R & R NR 4 SPOILER ACTUATOR IAW MM.SDR SIMA20160322003Actuator · malfunctionedOTBD SPOILERONS FAIL MSG. INTERROGATED MDC FOUND LT OTBD MFS PCU JAM. PERFORMED SPOST 1 RESET & OPERATIONS CHECKED IAW ETN-CR-27-093. OPERATIONS CHECKED GOOD. DEFERRED LT OTBD MFS PCU ACTUATOR IAW ETN-CR-27-093. R & R LT OTBD MFS PCU ACTUATOR IAW AMM 27-6SDR SWAA2016032150039Actuator · brokenLEFT WING NR 4 SPOILER, OTBD ACTUATOR BROKEN AT LOWER ATTACH POINT. R & R ACTUATOR IAW MM.SDR SWAA2016021249002Actuator · leakingRIGHT WING NR 8 FLIGHT SPOILER ACTUATOR LEAKED. R & R NR 8 SPOILER ACTUATOR IAW AMM.SDR SWAA2016021148948Actuator · leakingRIGHT WING NR 5 SPOILER, OTBD ACTUATOR LEAKED. R & R NR 5 SPOILER ACTUATOR IAW MM.SDR AALA20160209003Actuator · leakingRIGHT HYD QTY EICAS MSG, QUANTITY LIGHT ON, QUANTITY DECREASED TO .38 RF. SECURED LT ENG & LT ELEC PUMPS TO SAVE FLUID FOR LANDING. FLIGHT DECLARED AN EMER & LANDED WITHOUT FURTHER INCIDENT. R & R NR 1 SPOILER PCA IAW MM 27-61-02. OPERATIONALLY CHECKED GOOSDR CALA2016020800096Actuator · leakingIN FLIGHT RT HYD QTY EICAS LIGHT ON, CHECKING STATUS RT SYS HYD QTY DOWN TO .25. RAN QRH TURNED OFF RT ENG & ELEC PUMPS. FOUND NR 6 SPOILER PCA LEAKING. R & R IAW AMM 27-61-02. OPERATIONS & LEAK CHECKED GOOD. SERVICE RT HYD SYS.SDR R61A201602050115Bushing · corrodedDURING HEAVY CHECK, NR 3 SPOILER TO ACTUATOR ATTACH POINT BUSHING ON SPOILER FRAME IS CORRODED. MAINTENANCE R & R NR 3 SPOILER TO ACTUATOR ATTACH POINT BUSHING ON SPOILER FRAME IAW AMM 20-10-08. PN 170-34140-003, BUSHING.SDR SIMA20160203001Actuator · failedLEFT SPOILER NOT STOWING PROPERLY, IT LAGS BY = 5 SEC, SPOILER LEVER DISAGREE MSG. ACFT YAWED DRASTICALLY TO LT AS WE RECEIVED SPOILER LEVER DISAGREE MSG. R & R LT SPEED BRAKE ACTUATOR IAW AMM 27-62-02. OPERATIONS CHECKED GOOD, LEAK CHECKED GOOD.SDR SIMA20160108001Actuator · failedON DESCENT THE RT INBD SPOILER WOULD NOT STOW & CREW RECEIVED INBD FLIGHT SPOILERS & INBD SPOILERON MSGS. COMPLIED WITH AOM VOL 1 PROCEDURES, DECLARED AN EMER & LANDED WITHOUT INCIDENT. R & R RT INBD MULTIFUNCTION SPOILER ACTUATOR IAW MM 27-62-01. OPERATIONSDR R61A201511250921Bolt · corrodedDURING HEAVY CHECK, WAS REPORTED THAT LT WING NR 3 SPOILER PANEL MOUNTING HARDWARE IS CORRODED. MAINTENANCE R & R LT WING NR 3 SPOILER PANEL MOUNTING HARDWARE IAW AMM 27-64-01.SDR R61A201511250920Bolt · corrodedDURING HEAVY CHECK, LT WING SPOILER NR 3 PCU BOLT, NUT, BUSHING ARE CORRODED. MAINTENANCE R & R LT WING SPOILER NR 3 PCU BOLT, NUT, BUSHING IAW AMM 27-64-01. PN NAS6212-31D, BOLT.SDR R61A201511250911Bolt · corrodedDURING HEAVY CHECK, RT WING NR 4 SPOILER PCU BOLT IS CORRODED. MAINTENANCE R & R RT WING NR 4 SPOILER PCU BOLT IAW AMM 27-65-01, PN NAS6212-31D, BOLT.SDR R61A201511250910Bolt · corrodedDURING HEAVY CHECK, WAS REPORTED THAT LT WING NR 4, NR 5 SPOILER PCU BOLTS, NUTS, BUSHINGS ARE WORN AND CORRODED. MAINTENANCE R & R LT WING NR 4, NR 5 SPOILER PCU BOLTS, NUTS, BUSHINGS IAW AMM 27-64-01, P/N NAS62123-13D, BOLT.SDR R61A201511250909Bolt · corrodedDURING HEAVY CHECK, RT SPOILER NR 5 PCU BOLT IS CORRODED. MAINTENANCE R & R RT SPOILER NR 5 PCU BOLT IAW AMM 27-65-01, PN NAS 6212-31D, BOLT.SDR R61A201511250904Bolt · corrodedDURING HEAVY CHECK, NR 3 SPOILER PCU BOLT IS CORRODED. MAINTENANCE R & R NR 3 SPOILER PCU BOLT IAW AMM 27-65-01, PN NAS6212-31D, BOLT.SDR SWAA2015110945879Actuator · crackedRIGHT WING NR 5 GND SPOILER OTBD ACTUATOR ROD END CRACKED. R & R ACTUATOR IAW AMM.SDR FDEA201510313432Actuator · leakingBLUE RESERVOIR LO LEVEL ECAM WITH ASSOCIATED SPOILERS FAULTS. FOLLOWED ECAM & QRH, RETURNED FOR UNEVENTFUL LANDING. FOUND NR 3 RT SPOILER ACTUATOR, SIDE CAP BLOWN OUT, REQUIRES ACTUATOR PART. R & R NR 3 RT SPOILER ACTUATOR IAW AMM 27-64-14-04. OPERATIONAL SDR ASMF201510032Tube · leakingDURING TRANSIT CHECK, IT WAS DETECTED A HYD LEAK IN THE RT WING INNER. PERFORMED REVISION DETECTING HYD LEAK IN THE PRESS TUBE OF THE SPOILER ACTUATOR NR 9 IAW AMM 29-10-00, SO THE PRESS TUBE WAS REPLACED IAW AMM 20-10-51-401, TESTED CORRECT.SDR UIEA2015092700555Warning System · false activationREJECTED TAKEOFF AT 60KTS DUE TO CONFIG SPOILER EICAS WARNING. CUT OUT INSPECTION OF SPOILERS & CARRIED OUT OPERATIONS CHECK OF SPOILERS IAW AMM 27-61-00-715-001 & ALL SATISFACTORY.SDR CA150928004Link · broken(CAN) DURING REPLACEMENT OF RT INBD GROUND SPOILER ACTUATOR OUTPUT LINK (SCHED MAINTENANCE), FOUND THE CENTRAL FITTING WITH ONE BORE BROKEN.SDR CA150916009Actuator · leaking(CAN) SEPT 15,2015 AFTER LANDING MASTER CAUTION ILLUMINATED, HYD SYS A WENT TO 0. COMPLETED LOSS OF HYD FLUID SYS A CHECK LIST. SHUTDOWN NR 1 AFTER APPROXIMATELY 2 MINUTES. ON WALK AROUND, FOUND FLUID COMING OUT OF THE OTBD GROUND SPOILER ON THE RT WING. THE SDR FDEA201509042801Actuator · leakingDURING CLIMB OUT GOT AN EICAS RT HYD QTY, FOLLOWED SEVERAL MINUTES LATER BY RT HYD PRIME PUMP EICAS. BOTH SYS PRESS & QTY WENT ZERO. DEBRIEFED ENG DRIVEN HYD PUMP WAS NOT SHUT DOWN UNTIL AFTER ZERO PRESS WAS INDICATED. CASE DRAIN FILTER NEEDS TO BE REMOVED SDR REXA2015082900839Pcu · malfunctionedOUTBOARD SPOILERONS & OTBD SPOILERS CAUTION MSG. LT OTBD SPOILERON DEPLOYED & YELLOW COLOR ON DISPLAY. RT OTBD SPOILERON WHITE COLOR ON DISPLAY. R & R ON LT WING LT OTBD SPOILER PCU. OPERATIONAL TEST & LEAK CHECK GOOD IAW AMM 27-62-01-400-801.SDR ASMF201509002Motor · failedDURING TRANSIT CHECK, IT WAS DETECTED MSG IN EICAS & STATUS OF FLIGHT CONTROLS & SPOILERS WERE NOT FOLLOWED THE COMMAND. PERFORMED REVISION AT FLIGHT CONTROLS SYS IAW DMC B787-A-27-61-18-00A-720A-A, DETECTING THE SPOILER ELEC MOTOR UNIT POSITIONS 4, 5, 10 & 1SDR CA150710008Actuator · failed(CAN) ACFT RETURNED TO THE GATE DUE TO LOSS OF THE NR 1 HYD SYSTEM WITH AN ASSOCIATED ISO CAUTION LIGHT. MAINTENANCE REPLACED THE LT INBD SPOILER ACTUATOR DUE TO END CAP SEPARATION FROM ACTUATOR HOUSING.SDR CALA2015070694051Pca · faultedSPOILERS MSG ON UPPER EICAS INFLIGHT WHEN EXTENDING FULL FLAPS SET AT 15 DEG. REF WD 27-61-13 TO 18 SPOILERS PCA'S RESISTANCE CHECK OK. PER PREVIOUS PCA NR 2 FAULTED. ACCOMPLISHED SPOILERS PCA NR 2 & 11 RVDT PHASE SYNC VOLTMETER IAW MM 27- 61-00 P 500 PROCESDR CALA2015062994028Pca · faultyUNCOMMANDED ROLL TO THE RT WITH THE RT SYS HYD SELECTED OFF. INSTALLED NR 11 SPOILER PCA IAW AMM 27-61-02. OPERATIONS CHECKED OK.SDR CA150625001Actuator · fractured(CAN) ON TAKEOFF, FLIGHT CREW HEARD A BANG, BUT CONTINUED ON. DURING CLIMB UPON FLAP RETRACTION, FLAPS REMAINED AT 5 & HYD SYS NR 1 FLUID LEVEL WAS OBSERVED DOWN TO 1 QUART. FLIGHT CREW DECLARED AN EMER & LANDED TO A NEARBY AIRPORT WITHOUT FURTHER INCIDENT. SDR DBCA201505200005Actuator · out of adjustDURING APPROACH, THE AIRBRAKE INDICATOR CHANGED FROM SHUT TO OPEN. CREW VERIFIED AIRBRAKES WERE STOWED & LANDED UNEVENTFULLY. CONTACTED LOCAL MX FOR SUPPORT. ADJUSTED RIGGING ON RT AIRBRAKE ACTUATOR. OPERATIONS CHECKED GOOD.SDR CA150422002Actuator · failed(CAN) THE ACFT RETURNED TO THE GATE AS THE LT OTBD SPOILER DID NOT DEPLOY DURING THE FLIGHT CONTROL CHECK. IT WAS ALSO NOTED THAT THE NR 2 HYDRAULIC QTY WAS DROPPING. AT THE GATE, A FLUID LEAK WAS OBSERVED FROM THE LT WING. MAINTENANCE FOUND THE LT OTBD ROL
Back to JASC 2761