What was found
CAPTAIN REPORTED THAT DURING CRUISE, THE ACFT REQUIRED 4 UNITS OF COMPENSATION TO LT FOR MAINTAINING THE ACFT STRAIGHT AND LEVEL. MAINTENANCE PERSONNEL PERFORMED REVISION TO SPOILER IAW AMM 27-61-00, DETECTING THE SPOILER NR 2 SLIGHTLY RAISED; SO THE SPOILER OPS TEST WAS PERFORMED IAW AMM 27-61-00, NO DETECTING FAILURE. DURING OVERNIGHT CHECK AND AS PRECAUTIONARY ACTION, THE LATERAL CONTROL SYSTEM INSPECTION WAS PERFORMED IAW AMM 27-62-00, DETECTING A LOOSE ROD END FROM RT WING OTBD GROUND SPOILER ACTUATOR OF PANEL 12; SO THE OTBD GROUND SPOILER ACTUATOR WAS REPLACED IAW AMM 27-62-94, TESTED CORRECT.