SDR 2013FA0000359Pump · failedENGINE WOULD NOT START. FUEL PUMP PRESSURE ON PFD SHOWS "0" PSI.SDR UALA2013060703975None · noneLEFT HAND TANK INBD FUELING VALVE INOP CLOSED. TRANSFERRED FUEL TANK TO TANK SEVERAL TIMES. OBSERVED NORMAL OPERATION OF LT INBD FILL VALVE.SDR UALA2013060303827Impeller · failedLEFT AFT FUEL BOOST PUMP EICAS, FLT DIVERTED. REPLACED BOOST PUMP MOTOR IMPELLER IAW MM, OPS CHECKED OK.SDR SWAA2013052216329Pump · faultyON TAKEOFF BOTH FORE AND AFT NR 1 FUEL PUMP LOW PRESSURE LIGHTS ILLUMINATED WITH CORRESPONDING MASTER CAUTION LIGHTS. LIGHTS WENT OUT APPROX. 1 MINUTE AFTER DECK ANGLE REDUCED. NR 1 TANK AFT PUMP LIGHT ILLUMINATED IN CRUISE FLIGHT. COMPLIED WITH QRH AND OPESDR 2013FA0000257Pump · failedWHILE IN FLT, WHEN ELEC FUEL PUMP IS TURNED ON ENGINE RPM DECREASES BECAUSE OF RICH MIXTURE. GROUND CHECKS SHOWED FUEL PUMP PRESSURE TO HIGH. R2 ELEC FUEL PUMP.SDR 2013FA0000271Fuel Filter · leakingACFT LOW PRESSURE FUEL PUMP ASSY LEAKED. THE ASSY IS BRAND NEW OUT OF THE BOX AND HAS A SLOW DRIP OF ABOUT 1 DRIP EVERY 5 TO 10 MIN. THE DRIP APPEARS TO BE LEAKING FROM THE FILTER ASSY ATTACHED TO THE BOTTOM OF THE PUMP. A NEW FILTER ATTACHED TO THE BOTTOSDR UALA2013042602946Pump · failedN.3 FWD FUEL BOOST PUMP FAILED MM TEST, MANDATED BY EQ6283. NR 3 FWD FUEL BOOST PUMP REPLACED PER AMM.SDR CA130425005Pump · failed(CAN) FUEL PRESSURE FLUCUATING IN FLIGHT WITH NR 1 BOOST PUMP RUNNING. PILOT SELECTED NR 2 BOOST PUMP FUEL PRESSURE STABILIZED. MAINTENANCE FOUND NR 1 BOOST PUMP MOTOR UNSERVICEABLE.SDR UALA2013042502901Pump · no testNR 3 FWD FUEL BOOST PUMP FAILED. MM TEST 28-22- 00 PG601. NR 3 FWD FUEL BOOST PUMP REPLACED PER AMM.SDR UALA2013041802659Pump · faultedFUEL CONFIGURATION LIGHT AT 2.6 OUT OF BALANCE. FOLLOWED QRH PROCEDURE AND REBALANCED. TROUBLESHOT IAW SERVICE TIP 28-11-94. NO DISCREPANCIES NOTED. REMOVED AND REPLACED RIGHT CTR OVERRIDE FUEL PUMP IAW AMM, OPS AND LEAK CHECKED GOOD.SDR UALA2013041802657Pump · unknownCENTER FUEL PUMP PRESSURE LIGHT DOES NOT ILLIMINATE ON EICAS, BUT SHOWS ON OVERHEAD PUMP SWITCHES. TURNED ON OTHER MAIN BOOST PUMPS, CENTER FUEL BOOST PUMPS TEST NORMALLY.SDR UALA2013041202514Relay · faultedRT CENTER PUMP NOT SHUTTING DOWN AFTER TANK IS DRY, REPLACED RELAY 46QA IAW ASM 28-21-04.SDR ALGA0409201329919Cartridge · cloggedABOUT 10 MILES OFF OF BEACH LINE, THE BOOST PUMP CAME ON. PILOT TURNED ACFT AROUND AND RETURNED TO BASE. REPLACED LT BOOST PUMP CARTRIDGE.SDR UALA2013040902383Warning Light · false activationNR 2 FWD OVERRIDE PUMP OPERATING WHEN IT SHOULD BE OFF. OPS CHECKED NR 2 FWD OVERRIDE PUMP, REF AMM 28-31-01. CYCLED BOOST PUMP SWITCH OFF & ON, NO FAULTS FOUND.SDR UALA2013040102066Pump · failedFUEL IMBALANCE. RETURNED TO FIELD. AFTER INPUT MONITORING TEST POINTED TOWARDS PRESSURE SWITCH ON NR 3 FWD OVRD PUMP. REPLACED PUMP, OPS CHECKED GOOD.SDR UALA2013031801628Pump · failedLEFT CENTER FUEL PUMP CIRCUIT BREAKER TRIPPED. REPLACED LT CENTER FUEL OVRD PUMP.SDR ASAA2013031394159Warning Light · false activationLEFT CENTER TANK FUEL BOOST PUMP LOW PRESSURE LIGHT ILLUMINATED IN FLIGHT IN CRUISE AT 33,000 FT. MASTER CAUTION ALSO ILLUMINATED. 16, 800 LBS IN CENTER TANK. PERFORMED CENTER TANK BOOST PUMP AUTO SHUTOFF FUNCTIONAL TEST IAW MM 28-22-00, OPS CHECKED GOOD. SDR COZR20130311003Pump · failedINSTALLED FOUR O/H FUEL BOOST PUMPS, IN SAME POSITION. EACH BOOST PUMP WOULD OPERATE WHEN INITIALLY POWERED UP, THEN FAIL TO OPERATE ON SUBSEQUENT ATTEMPTS. INSTALLATION OF FIFTH OVER HAULED UNIT OPS CHECKED NORMAL WITH NO SUBSEQUENT FAILURES.SDR TRBA20130307001Pump · corrodedDURING MX, INSPECTION CORROSION WAS FOUND ON LT WING FUEL ELECTRICAL PUMP CUT-OUT HOLES.SDR FQAR1303021301302Pump · wornENGINE OPERATED AT LOWER POWER SETTINGS ONLY. ENGINE DIED AT HALF TO FULL THROTTLE. FOUND ELECTRIC FUEL PUMP TO BE INOPERATIVE. UPON FURTHER INVESTIGATION FOUND THAT VALVE SEATS IN THE ELECTRIC FUEL PUMP HAD WORN ALLOWING THE VALVES TO WEDGE INTO THE SEAT. SDR AALA20130301024Pump · inoperativeORD - INFLIGHT ORD-DFW CREW REPORTED FUEL WAS NOT BURNING OUT OF CENTER TANK AND WING TANKS WERE DECREASING AND CENTER FUEL PRESSURE LOW LIGHT WAS ON. FLIGHT DIVERTED ORD LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED BOTH CENTER TANK BOSDR ASMF201303020Pump · leakingDURING TRANSIT CHECK, A FUEL LEAK WAS DETECTED. MAINTENANCE PERSONNEL DETECTED THE FUEL PUMP SEAL DAMAGED ON RT ENGINE, FUEL PUMP WAS REPLACED IAW AMM 73-11-01 AND TESTED IAW AMM 71-00-00, ALL CORRECT.SDR AALA20130216004Pump · inoperativeMSY - INFLIGHT MCO-DFW. CREW REPORTED CENTER TANK FUEL WILL NOT FEED. FLIGHT DIVERTED MSY LANDED WITHOUT INCIDENT. REPLACED CENTER TANK FUEL BOOST PUMP. SYSTEM GROUND CHECK NORMAL OPERATION.SDR ASAA2013020393813Relay · failedLEFT CENTER BOOST PUMP AUTO SHUTOFF INOPERATIVE. DUPLICATED DEFECT. FOUND R936 LT AUTO SHUTOFF 115V AC RELAY FAILED. REPLACED R936 RELAY REF WDM28-23-11. ACCOMP CENTER TANK BOOST PUMP AUTO SHUTOFF FUNCTIONAL TEST REF MM28-22-00, OPS TEST NORMAL.SDR ERAA20130005Pump · corrodedEXTERNAL SURFACE OF BOTH FUEL PUMPS HAVE SURFACE CORROSION. REPAIRED BY BLENDING OUT CORROSION REF BOMBARDIER RD 8-57-1907.SDR ASAA2013012893777Pump · malfunctionedCENTER TANK LT BOOST PUMP LOW PRESSURE LIGHT ON. REPLACED LT CENTER TANK BOOST PUMP REF MM 28-22-41. OPS AND LEAK CHECKED GOOD.SDR AALA20130124012Pump · inoperativeDFW INFLIGHT MIA-SEA. CREW REPORTED LEFT CENTER FUEL BOOST PUMP LOW PRESSURE LIGHT ILLUMINATED IN FLIGHT. FLIGHT DIVERTED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED LEFT FUEL PUMP OVERRIDE MOTOR IMPELLER. SYSTEM GROUND CHECK NORSDR RYNA2013012200002Pump · failedLEFT AFT BOOST PUMP FAILED INFLIGHT. PLACED ON MEL 28-22-1 CAT C DDD 1 FEB 2013. ISSUED DMI 3025. SUPPLEMENTAL REPORT TO FOLLOW.SDR AALA20130116005Bonding Strap · corrodedLEFT WING NUMBER 1 FUEL BOOST PUMP, UPPER BOND STRAP HAS CORROSION. REPAIRED PER EA B737-57-027879.SDR CA130115001Fuel Bowl · leaking(CAN) TOP CASTING OF FUEL BOWL ASSY FOUND TO BE LEAKING FROM FORWARD FITTING HOLE FROM THE THREADS, AREA AROUND NOTICED TO HAVE FUEL STAINING PRESENT UPON INSPECTION, TOP CASTING REPLACED NEW, LEAK CHECK COMPLETED UPON NEW CAST, PN 0756039-6. INSTALLATION SERSDR ASAA2013011093661Relay · inoperativeRIGHT FWD FUEL PUMP LOW PRESSURE ANNUNCIATOR ILLUMINATED ON GROUND WITH PUMP SWITCH ON AND 6000 LBS IN TANK. FOUND R21 RELAY INOPERATIVE. R & R R21 RELAY IAW WDM 28-23-11. OPS TESTED, GROUND FAULT INTERRUPTED CIRCUIT FOR RT FWD BOOST PUMP IAW MM 28-22-41-720SDR CA130114008Nozzle · failed(CAN) DURING PUSH BACK A FUEL LEAK ON THE RT WING CAUSED THE PUSH BACK TO BE STOPPED. FIRE DEPARTMENT WAS CALLED TO THE ACFT. ACFT WAS TOWED BACK TO THE GATE AND MAINTENANCE IS INVESTIGATING THE CAUSE OF THE FUEL LEAK. FLT WILL RE DEPART WITH A DIFFERENT ACFSDR CA130110003Pump · noisy(CAN) DURING ACFT START SEQUENCE, WHILE PRIMING THE ENGINE THE PUMP MADE A SQUEALING NOISE AND WHEN THE ENGINE WAS STARTED THE AUXILIARY FUEL PUMP WARNING LIGHT CAME ON. ACFT CONTINUED TO RUN ON THE GROUND USING ONLY THE MECHANICAL FUEL PUMP. AFTER THE ENGINSDR UALA2013010700084Cover · unsecureRIGHT CENTER FUEL PUMP SWITCH WILL NOT TURN OFF. SECURED OVERHEAD PANEL COVER PLATE TO FUEL SWITCHES. OPS OK.SDR 2013FA0000016Thrust Washer · wrong partDURING O/H OF PUMP, THRUST WASHER FOUND WITHOUT DETE CODE. THE THRUST WASHER AFFECTED BY AD 2001-12-21, AD2001-12-21 REQUIRED REPLACEMENT OF AFFECTED THRUST WASHERS WITH 24 MONTHS OF EFFECTIVE DATE WHICH WAS 7/26/2001.SDR CA121217005Pump · failed(CAN) FUEL EMERGENCY DECLARED ON APPROACH. CENTER TANK FUEL SYS WOULD NOT SCAVENGE WITH 900 KGS, FUEL TRAPPED IN CENTER TANK. MINIMUM FUEL WAS 7.1 INCLUDING CENTER TANK TRAPPED FUEL, LANDED WITH 6.9 FOB. ASR TO FOLLOW IAW L4880810 CENTER TANK SCAVENGE BURNEDSDR TRBA20121126005Pump · corrodedDURING MX INS FOUND THE RT WING ELECTRIC FUEL PUMP WITH CORROSION AROUND FASTENERS (BOLT). THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING ELECTRIC FUEL PUMP AROUND FASTENER (BOLT) NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNEDSDR TRBA20121126001Pump · corrodedDURING MX INSPECTION, FOUND THE LT WING ELECTRIC FUEL PUMP WITH CORROSION AROUND FASTENERS (BOLT). THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING ELECTRIC FUEL PUMP IAW SRM 51-21-42. NO MATERIAL REMOVED.SDR ASAA2012112393345Pump · low pressureNR 2 AFT LOW PRESSURE LIGHT ILLUMINATED ON GROUND WITH PUMP SWITCH ON. VERIFIED DISCREPANCY. REPLACED NR 2 AFT BOOST PUMP IMPELLER IAW AMM 28-22-41. NR 2 AFT BOOST PUMP OPS NORMAL IAW AMM 28-22-41. NO FUEL LEAKS NOTED. GROUND VERIFICATION GOOD.SDR CA121127004Pump · failed(CAN) AUXILIARY FUEL PUMP FAILED ON START UP FOLLOWING 100 HOUR INSPECTION OF THE AIRCRAFT. AUXILIARY FUEL PUMP REPLACED.SDR UALA2012112106737Relay · faultyCTR R FUEL PUMP EICAS WILL NOT DISPLAY FOR GROUND CHECK PER AFM. REPLACED K10871, RIGHT OVERRIDE PUMP SO TIME DELAY RELAY. SYSTEM OPS CHECKED OKAY.SDR 2012FA0000802Screw · looseFUEL PRESSURE READING DROPPED BELOW .5 PSI CAUSING ENGINE MONITOR TO ISSUE WARNING AFTER 550 HOURS OPERATION ON FUEL PUMP. UPON CHECKING FUEL PUMP, FOUND SCREWS ON BOTTOM OF MECHANICAL FUEL PUMP TO BE ONLY A LITTLE TIGHTER THAN FINGER TIGHT AND THEY HAD BEEN SDR UIEA2012110300510Pump · failedLT FWD BOOST PUMP LOW PRESSURE LIGHT ILLUMINATED WITH LT FWD FUEL PUMP EICAS MESSAGE. REPLACED LT FWD BOOST PUMP WITH REPAIRED UNIT IAW AMM 28-22-03, LEAK AND OPS CHECKED GOOD.SDR UALA2012102506122Unknown · malfunctionedFUEL PUMP CENTER R RIGHT CENTER (OVERRIDE) FUEL PUMP SWITCHED ON AND PUMP OUTPUT PRESSURE LOW. STATUS CREW COMMENTS: FUEL PUMP CENTER R STATUS MSG. DEFERRED RT CTR FUEL PUMP PER MEL. RESET CB TO PUMP AND ACP TEST REF MM. PUMP OPERATED NORMAL AND ALL MSG'S CSDR CA121025011Pump · noisy(CAN) FUEL PUMP MAKING NOISE DURING GROUND RUN. FUEL PUMP REPLACED.SDR UIEA2012101200465Switch · inoperativeLEFT AFT BOOST PUMP SWITCH INOPERATIVE. REPLACED PUSH SWITCH ASSY IAW AMM 33-13-00, OPS CHECKED GOOD.SDR CA121012011Pump · inoperative(CAN) AUXILIARY FUEL WARNING LIGHT ON. AUXILIARY FUEL PUMP FOUND INOPERATIVE AND REPLACED.SDR UALA2012100405631Pump · faultyAS PREVIOUS MRM FUEL CONFIG LIGHT ON 3 HOURS INTO FLIGHT WITH 1400LBS MORE FUEL IN LEFT WING TANK. REMOVED AND REPLACED CENTER RIGHT OVERRIDE PUMP IAW AMM, NO LEAKS NOTED.SDR 2012F00196Sleeve · damagedVISUAL INSPECTION OF THE FUEL TANK BOOST PUMP WIRING IAW SB 767-28A0053, REV 03. DURING THE INSPECTION, BOTH OUTER SLEEVES GOING TO FWD LEFT AND AFT LEFT MAIN FUEL BOOST PUMPS WERE FOUND TO HAVE HOLES AND SPLIT DOWN THE SIDES AT A FEW POINTS.SDR UIEA2012092200440Warning Light · false activationDURING CRUISE FLIGHT, LEFT FORWARD FUEL BOOST PUMP LIGHT ILLUMINATED. TURNED PUMP OFF IAW QRH. OPS CHECK OF LT FORWARD BOOST PUMP SATISFACTORY. OK FOR SERVICE, REF AMM 28-22-00.
Back to JASC 2822