SDR UIEA2021072601630Line · leakingFOUND PUDDLE OF OIL IN RIGHT ENGINE COWL AND OIL DRIPPING FROM ENGINE(<P>FOUND ENGINE HYDRALIC LEAK,TIGHT AND TORQUE HYD LINE FROM PYLON TO ENG IAW AMM 71-00-00. SERVICED R HYD IAW AMM 12-00-00 NO LEAK AT THIS TIME. A/C OK TO RELEASE</P>)SDR AALA202107262361Manifold · leakingAIRCRAFT WAS GROUNDED: FLIGHT CREW DECLARED AN EMERGENCY INTO PHX DUE TO A YELLOW HYDRAULIC SYSTEM RESERVOIR LOW LEVEL ECAM MESSAGE. THE AIRCRAFT LANDED SAFELY AND TAXIED TO THE GATE WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND THE YELLOW HYDRAULIC SYSTEM HIGHSDR V6NA2021072401B-Nut · crackedON APPROACH TO DAL, SELECTED FLAPS 20 AND GEAR DOWN. WHILE FLAPS AND GEAR WERE MOVING ENCOUNTERED HYDRAULIC PRESSURE LOSS. DECLARED EMERGENCY AND DIVERTED TO LONGER RUNWAY AT DFW. UPON LANDING EMERGENCY BRAKE AIR WAS UTILIZED. PASSENGERS DEPLANED AND ROUTED TOSDR WX0A2021072373790Hose · leaking(EMERGENCY DECLARED) HYD G RSVR LO LVL ECAM AFTER LANDING GEAR EXTENDED. / REMOVED & REPLACED LEFT MLG DOOR ACTUATOR HYDRAULIC FLEX HOSE , IAW 32-31-39. LEAK CHECK GOOD. AIRCRAFT OK FOR SERVICE."SDR IPXA2021072271955Pressure Switch · leakingINSPECTION TYPE:N/A**DIVERSION** NO EMERG** AC LANDED WITHOUT INCIDENT** ABOUT AN HOUR INTO FLT NOTICED BLUE HYD QTY DECREASING. AT THE RED DOT ECAM "BLUE HYD LO QTY " MSG. C/W ECAM AND AOM PROCEDURES FOR THE LO QTY AND THE BLUE HYD LO PRESSURE.FOUND YAW DAMPESDR FDIA202107260001Line · splitA HYDRAULIC LINE FAILED AT A FOUR POINT UNION IN THE AFT SERVICE AREA, AT OR NEAR THE TIME OF ROTATION. THIS CAUSED A TOTAL LOSES OF HYDRAULIC PRESSURE SYSTEM WIDE. AIRCRAFT COMPLETED TAKEOFF AND CLIMBED TO PATTERN ALTITUDE AND COMPLETED A NORMAL APPROACH AND SDR 1AZA20210728001Housing · failedTHE LEFT SIDE HYDRAULIC SYSTEM FILTER BOWL ASSEMBLY SEPARATED FROM THE UPPER FILTER HOUSING DUE TO A FAILURE IN THE THREAD PORTION OF THE FILTER BOWL. NO STRESS ON THE BOWL COULD BE DETECTED AND THE REASON FOR THE FAILURE REMIANS UNKNOWN. FAILURE OF THE BOWLSDR R61A2021072100581Hose · failedHYDRAULIC SYSTEM 2 LOW PRESSURE WHEN ON SHORT FINAL (GEAR, FLAPS IN LANDING CONFIGURATION). DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R RH MLG HOSE ON DOWN LOCK ACTUATOR. NO LEAKS NOTED.SDR R61A2021072000580Hose · failedHYDRAULIC SYSTEM 2 LOW PRESSURE WHEN ON SHORT FINAL (GEAR, FLAPS IN LANDING CONFIGURATION). DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R RH MLG HOSE ON DOWN LOCK ACTUATOR. NO LEAKS NOTED.SDR SWAA2021071995838Hydraulic System · failedREF LP 0273117E TOTAL LOSS OF HYDRAULIC SYSTEM B. FLUSHED HYDRAULIC SYSTEM B. REPLACED ALL HYDRAULIC SYSTEM B FILTERS REF AMM 29-11-00REF AMM 29-11-00 REPLACE B SYSTEM HYDRAULIC CASE DRAIN FILTER ELEMENTS AT FIRST SCHEDULED MAINTENANCE OPPORTUNITY FOLLOWING SDR DXTA2021071945380Line · leakingHYDRAULIC LINE: HYDRAULIC FLUID LEAKING NEAR LEFT MAIN BRAKE. HIGH PITCH SQUEAKING HEARD WHEN LEFT BRAKE WAS ACTUATED PRIOR TO HYDRAULIC LEAK DISCOVERY. //SIGNOFF// CLEANED OFF ALL HYDRAULIC FLUID AROUND BRAKES AND TIRES AND WHEELWELL FOUND LOOSE HYDRAULIC LINSDR WX0A2021071973771Line · leakingLOSS OF YELLOW HYRAULIC FLUID AND ASSOCIATED RESERVOIR LOW LEVEL ECAM. / FOUND ENG 2 YEL HYD PRESS SW LINE PN -AE-720334-1 LEAKING. REPLACED LINE AND RESERVICED YEL HYD IAW AMM 29-13-49 PB 401 CONF 06. VERIFIED YEL HYD PUMP NOT CAVITATED IAW AMM 29-00-00-280-0SDR SWAA2021080200750Line · leakingAT BEGINNING OF DSECENT; NO 2 ENGINE HYDRAULIC PUMP PRESSURE FLICKERED; THEN EVENTUALLY CAME ON STEADY. HYDRAULIC B-SYSTEM QTY WAS 0. DID QRH PROCEDURE TO SECURE ENG DRIVEN PUMP; THEN ELECTRIC PUMP ; LOW PRESSURE LIGHT ILLUMINATED. RAN QRH FOR B-SYSTEM HYDRAULSDR 9JLA2021072914421Fitting · leakingTHE FLIGHT CREW REPORTED THAT DURING POST FLIGHT CHECKS IT WAS NOTED HYDRAULIC LEAKAGE FROM THE LEFT MAIN LANDING GEAR BRAKE AREA. THE MAINTENANCE VENDOR DETERMINED THE LEAKAGE OCCURRED AT THE NO1 BRAKE BLEED FITTING. THE AREA WAS CLEANED AS REQUIRED AND THE BSDR AALA202107197545Pressure Switch · inoperativeAIRCRAFT WAS GROUNDED: GREEN HYDRAULIC PRESSURE LOW CAUTION 7 MINUTES FROM LANDING. CREW DECLARED EMERGENCY. WAS NOT ABLE TO TAXI DUE TO NOSE WHEEL STEERING UNAVAILABLE. UPON ARRIVAL, FOUND GREEN SYSTEM QUANTITY ABOVE MINIMUM GAGEABLE LEVEL. LEAK WAS FOUND ATSDR DALA2021071604034Ram Air Turb · no testSHIP 3328 RAT FAILS TO AUTO DEPLOY DURING TEST. CORRECTIVE ACTION: FAILED VOLTAGE CHECK AT CONNECTOR 11JR-B. REMOVED AND REPLACED HSMU AND PERFORMED SUCCESSFUL OPERATIONAL TEST. (1876515)SDR B4VR2021081900001Line · leakingPILOT SQUAWK: LANDING GEAR FAILURE. USED EMERGENCY GEAR EXTEND. AFTER TAKEOFF, WE GOT 3 RED WHEN WE PUT THE GEAR UP. WE TRIED AGAIN AND IT WENT UP. FAILED WHEN WE TRIED TO PUT GEAR DOWN. CAS MESSAGE: HYDRAULIC PUMP ON, GEAR SYS. CORRECTIVE ACTION. REPLACED HYDSDR CJPA2021072600021Line · failedABOUT 20 MILES FROM LANDING, ATC ISSUED INSTRUCTIONS TO SLOW TO 190 KTS. I USED THE AIRBRAKES TO SLOW, AND WHEN RETRACTING THE AIRBRAKES, THE PM NOTICED THE #2 HYD PUMP WARNING LIGHT FLICKER, ACCOMPANIED BY LOW PRESSURE AND NEAR ZERO QUANTITY. THERE WAS STILL SDR CALA2021071401100Line · leakingECAM CAUTION MESSAGE - B RSVR LO LVL MESSAGE INOP - HYD HYD B SYS LO LVL UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. INVESTIGATE AND CONTACT TOMC 847-700-9980 UPDATED MAA CODE EFS USING VENDOR MAA SCREEN PLEASESDR SWAA2021071592651Line · leakingLOSS OF HYDRAULIC SYS B (PRESSURELINE FROM BSYSTEM ELECTRIC PUMP TO FILTER LEAKING) / HYDRAULIC FLEXIBLE LINE FOUND LEAKING R/H SIDE W/W P/N AS116-08-0294, IPC REF 29-11-21-11 STEM 90. REMOVED & REPLACED FLEXIBLE HOSE INSTALLATION FOR INTERIM REPAIR PROCEDURE SDR AALA202107133821Bypass Valve · leakingAIRCRAFT WAS GROUNDED: GREEN HYDRAULIC RESERVOIR LOW LEVEL, GREEN ENGINE 1 PUMP LOW PRESSURE, GREEN SYSTEM LOW PRESSURE, YELLOW HYDRAULIC PUMP OVERHEAT WHEN GREEN SYSTEM FAILED. AN EMERGENCY WAS DECLARED, AND THE AIRCRAFT RETURNED TO PHX. THE CREW PERFORMED A SDR F3LA2021071200053Fitting · leakingHYD. Y RSVR LO LVL. R&R HYD. YELLOW PRESSURE LINE FITTING AND LINE AT ENG #2 REF. AMM 29-13-49-400-812-A. PERFORMED MIN. IDLE LEAK CHECK IS OK. REF. NON ROUTINE #123083.SDR FDEA202107101720O-Ring · leakingON DESCENT INTO MEM RECEIVED ECAM YELLOW SYS PUMP LO PRESS. DETERMINED YELLOW SYS LOW QUANTITY. COMPLIED WITH ECAM/QRH. UPON INVESTIGATION OF HYDRAULIC LEAK, FOUND YELLOW SYS ISOLATION VALVE BLOCK LEAKING. FOUND O-RINGS FROM VALVE BLOCK PLUGS TORN. REPLASDR F3LA2021071200054Fitting · crackedLP156984 ITEM 1, DISCREPANCY: GREEN HYDRAULIC SYSTEM LO PRESSURE. AIR TURN BACK TO DENVER. CORRECTIVE ACTION: FOUND PRESSURE FITTING LEAKING IN #1 ENGINE PYLON. REPLACED FITTING AND HYD LINE, DUE TO BOTH NEEDING TO BE REPLACED AS A SET PER THE IPC (SDR 2021F00236Hydraulic System · leaking09.07.2021 01:43 A HYDRAULIC LEAK IN THE ELEVATOR FEEL COMPUTER. DURING TRANSIT CHECK, A HYDRAULIC LEAK WAS DETECTED IN THE EMPENNAGE AREA AND FEEL DIFFERENTIAL PRESSURE LIGHT TURNED ON. MAINTENANCE PERSONNEL PERFORMED REVISION AT ELEVATOR, DETECTING A HYDRAUSDR GTIA2021071235863Connector · looseFUME ODOR ON DECENT FROM FL190 TO 16000 LASTED 2 MINUTES COCKPIT ONLY-FOUND HYDRAULIC CONNECTIONS LOOSE ON AFT CARGO DOOR MANUAL SELECTOR VALVE. TORQUED TO CARRECT VALUE IAW AMM 52-36-15 OPS CHECKS GOOD NO LEAKS NOTED AT THIS TIME.SDR DBCA2021071270002Pressure Valve · failedAFTER TAKE-OFF LANDING GEAR WOULD NOT RETRACT. CREW DECLARED AN EMERGENCY AND RETURNED TO CHS. MAINTENANCE TROUBLESHOT TO DEFECTIVE HYDRAULIC PRESSURE REGULATING VALVE. PRESSURE REGULATING VALVE WAS REPLACED WITH AN OVERHAULED UNIT. PERFORMED MULTIPLE EXTENSDR DALA2021071203885Line · leakingSHIP 1805 -ATB- DUE TO RMLG DOOR OPEN INDICATION WITH LANDING GEAR SELECTED "UP". CORRECTIVE ACTION: C/W OVER WEIGHT LANDING INSPECTION. FOUND HYDRAULIC LINE LEAK AT GEAR OPERATED SEQUENCE VALVE. REPLACED LINE, GEAR OPERATED AND DOOR OPERATED SEQUENCE VALVES. SDR 2021F00235Filter · leaking07.07.2021 15:44 BY AHM ALERT 29-0041-R091 AT RIGHT HYDRAULIC RESERVOIR LEVEL. IN ACCORDANCE WITH AHM ALERT 29-0041-R091 OF REMOTE DIAGNOSTIC GE/CFM SYSTEM AT MEX ON RIGHT HYDRAULIC RESERVOIR LEVEL LOW AND ALERT 29-0044-S860 BY POSSIBLE SLOW LEAK DETECTED IN TSDR AALA202107080547Warning Message · false activationAIRCRAFT WAS GROUNDED: DURING INITIAL CLIMB YELLOW HYDRAULIC RESERVOIR OVER HEAT ECAM MESSAGE OCCURRED. CREW ACCOMPLISHED ECAM NON-NORMAL PROCEDURE BUT THE OVERHEAT CONDITION PERSISTED SO THE CREW SHUT DOWN THE YELLOW HYDRAULIC PUMPS AND THE OVER HEAT CONDITIOSDR DALA2021070703774O-Ring · failedSHIP 3251 HYD G SYSTEM LOW LEVEL. QRH 13.13 EXTENDED AND 14.18 LDG GEAR GRAVITY EXTENSION. STOPPED ON RWY 34L SLC. TOWED TO GATE EMERGENCY DELIVERED. CORRECTIVE ACTION: FOUND BAD O-RING LEAKING ON FLT CONTRL PRESS SWITCH (10CE2). R/R O-RING ON FCPS (10CE2) PERSDR DXTA2021070744810Line · shearedAPPROXIMATELY 10 TO 15 MINUTES AFTER DEPARTURE WE GOT A HYD PRESS LOW- R ANNUNCIATOR. FOLLOWED SHORTLY AFTER BY THE HYD VOLUME LOW ANNUNCIATOR THIS WAS FOLLOWED SHORTLY BY THE HYD PRESS LOW R-L ANNUNCIATOR. WE COMPLIED WITH BOTH CHECKLISTS. WE BLEW THE GEAR DOSDR AALA202107073896Check Valve · leakingAIRCRAFT WAS GROUNDED: ECAM WARNING FOR GREEN HYDRAULIC RESERVOIR LOW LEVEL AND #1 ENGINE GREEN HYDRAULIC PUMP LOW PRESSURE. CREW ACCOMPLISHED QRH PROCEDURES, DECLARED AN EMERGENCY AND RETURNED TO CLT. DURING APPROACH INTO CLT TURNED PUMP ON, 3000 PSI. GREEN SDR DALA2021070503703Structure · corrodedCORROSION ON UPPER CENTER TANK SKIN AT PULLEY SUPPORT ANGLE AT STA. 745 LBL 25-34. BLENDED AND REMOVED ALL CORROSION REF B717 SRM 57-10-01-1A. UT THICKNESS INSPECTED AND MAPPED ON 1/2" GRID PER NDTSPM PART 04-00-00 TO 04-00-09. ORIGINAL THICKNESS IS .252. LOWESDR DALA2021062903531Flex Line · leakingSHIP 3317 "HYD Y ENG 2 PUMP LO PR" "Y SYS LOW PR". CORRECTIVE ACTION: REMOVED FLEX LINE FROM Y PRES LINE FROM FIREWALL FOR PRES SENSE. LINE OBSTRUCTED. REPLACED CASE DRAIN FILTER. INSTALLED FLEX LINE. REPLACED YELLOW HP FILTER AND Y ENG PRESSURE SWITCH. (73504SDR CALA2021062800987Drain · leakingENG 1 HYD LOW PRESS LIGHT ON IN FLIGHT QUAN DROPED TO 0 FOUND HYD LEAK COMING FROM RETURN FILTER CASE & CLAM FOUND RETURN FILTER CASE BEND FOUND LEAK COMMING FROM THE FILTER CASE DRAIN ASSY. REPLACED CAS E AS PER AMM 29-11-61 PB401. PRECAUTIONARY REPLACED EDP SDR DALA2021062903532Relief Valve · faultedSHIP 3320 -HYD- CREW PERFORMED ALTERNATE GEAR EXTENSION DUE TO GREEN HYDRAULIC RSVR LOW ECAM MESSAGE AFTER TAKEOFF. CORRECTIVE ACTION: FOUND PRESSURE RELIEF VALVE 5001JM1 BLEEDING THE RESERVOIR PRESSURE. REPLACED BLEED VALVE.(7762866)SDR CALA2021062300943Filter · leakingLEAK AND OPS CHECK DUE ON LEFT SYSTEM HYDRALIC DUE TO FILTERS BEING CHANGED. LEAK AND OPS CHECKED LEFT HYDRAULIC FILTER.OPS HECKED GOODSDR AALA202106259007Filter · cloggedAIRCRAFT WAS GROUNDED: AT TOP OF DESCENT, GREEN HYDRAULIC RESERVOIR OVER HEAT INDICATION ON ECAM HYDRAULIC PAGE. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED AT MYR SAFELY WITHOUT FURTHER INCIDENT. ACCOMPLISHED TSM 29-11-00, FOUND LEFT ENGINE THRUST REVESDR QXEA2021062200304Hydraulic System · failed#2 HYDRAULIC SYSTEM FAILURE AFTER REACHING CRUISE ALTITUDE/ DECLARED EMERGENCY AND RETURNED TO FIELD. LANDING UNEVENTFUL. AIRCRAFT OUT OF SERVICE FOR REPAIRS.SDR DALA2021062203377O-Ring · leakingSHIP 8137 - DIV - TO MCI DUE TO NUMBER 2 HYDRAULIC QUANTITY WENT TO ZERO FOLLOWED BY LOW / PRESSURE CAUTION. CORRECTIVE ACTION: REPLACED THE O-RING ON NUMBER 4 MULTI-FUNCTION SPOILER / ACTUATOR RETURN FITTING. REPLACED THE ENGINE DRIVEN PUMP AND CASE DRAIN FILSDR UIEA2021061901384Shutoff Valve · failedFLT CONTROL VALVES CAUTION MESSAGE. REMOVED AND REPLACED FLIGHT CONTROL HYD SHUT-OFF MODULE, OPS CHECK OF ALL FLIGHT CONTROL SHUT OFF VALVES GOOD PER AMM 27-13-00 AND 27-23-00. REPLACED THE NR 1 WING HYD SHUT OFF VALVE PER AMM 27-13-01.SDR ASMF2021071400107Line · leaking21.06.2021 15:30 HYDRAULIC LEAK IN TAIL CONE. DURING TRANSIT CHECK, A HYDRAULIC LEAK WAS DETECTED IN TAIL CONE. MAINTENANCE PERSONNEL PERFORMED REVISION DETECTING HYDRAULIC LEAK AT ELEVATOR FEEL COMPUTER LINE; SO THE ELEVATOR FEEL COMPUTER LINE WAS TIGHTENED SDR WX0A2021062173745Switch · faulted(EMERGENCY DECLARED) CLIMBING THROUGH FL 270 WE RECEIVE HYD Y RESVR LO LVL ECAM. ECAM LED UT TO SHUTDOWN PUT PUMP AND ENG 2 PUMP / FOUND YELLOW HYD RSVR LOW LEVEL SWITCH WITH LOW VOLTAGE. REMOVED AND REPLACED LOW LEVEL SWITCH IAW TSM 29-13-00-810-801-A AND ASDR SWAA2021062186152Filter · leakingLOSS SYSTEM B HYDRAULIC FLUID INFLT BOTH LOW PRESS LIGHTS ILLUMINATED ELEC 1B ENG 2 ; / FOUND FLAP FLOW LIMITER FUSE LEAKING. R/R EDP AND EDMP CASE DRAIN FILTERS FOR B SYS; REPLACED B SYS RETURN FILTER. FOUND NO EVIDENCE OF DEBRIS OR METALIC PARTICLES; RESERVISDR AALA202106219033Drain Valve · inoperativeAIRCRAFT WAS GROUNDED: COMPLETE LOSS OF CENTER HYDRAULIC SYSTEM FLUID QUANTITY CAUSING LOSS OF CENTER HYDRAULIC SYSTEM OCCURRED SHORTLY AFTER TAKEOFF. CAPTAIN STATED THEY WOULD DECLARE AN EMERGENCY ON ARRIVAL AND CONTINUE TO MIA. FLIGHT LANDED WITHOUT FURTHERSDR AALA202106219032Filter · inoperativeAIRCRAFT WAS GROUNDED: COMPLETE LOSS OF CENTER HYDRAULIC SYSTEM FLUID QUANTITY CAUSING LOSS OF CENTER HYDRAULIC SYSTEM OCCURRED SHORTLY AFTER TAKEOFF. CAPTAIN STATED THEY WOULD DECLARE AN EMERGENCY ON ARRIVAL AND CONTINUE TO MIA. FLIGHT LANDED WITHOUT FURTHERSDR AALA202106179025Check Valve · openAIRCRAFT WAS GROUNDED: ON CLIMB OUT YELLOW HYDRAULIC RESERVOIR OVERHEAT WARNING OCCURRED, AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHX WHERE IT LANDED SAFELY WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED HYDRAULIC CHECK VALVE 3083GM AND ACCOMPLISDR CALA2021061500882Packing · leakingHYD Y ENG2 RSVR LOW LVL FOUND PTU MANIFOLD LEAKING AT QUICK DISCONNECT FITTING 3701 GM, UPON REMOVAL FOUND FAILED PACKING REMOVED AND REPLACED PACKING REF AMM 29-13-15-400-001-A OPS CHECK NORMAL IAW AMM 29-23-00-710-002-A.SDR AALA202106189028Packing · leakingAIRCRAFT WAS GROUNDED: SYSTEM A HYDRAULIC FLUID LOSS, FLIGHT DECLARED EMERGENCY AND DIVERTED TO IAH. REPLACED PACKING AT PRESSURE SWITCH AND MODULE INTERFACE IAW AMM 29-31-12-401, LEAK AND OPS CHECK GOOD.
Back to JASC 2910