What it covers
The component which filters sediment from the hydraulic fluid in the auxiliary system. Typical parts are seal, gasket, housing, element, and packing, etc.
Service difficulty reports · 20
Reports filed under 2922, newest first.
| 1995 | 1 |
|---|---|
| 1996 | 1 |
| 1998 | 1 |
| 2001 | 3 |
| 2002 | 2 |
| 2003 | 1 |
| 2004 | 1 |
| 2007 | 2 |
| 2009 | 1 |
| 2011 | 4 |
| 2012 | 2 |
| 2025 | 1 |
SDR SWAA2025032007747Filter · low pressureAFTER FLAPS 5 HYD A SYSTEM LOW PRESSURE LIGHTS ON BOTH ENG AND ELECTRIC PUMP SHORTLY AFTER LOW PRESSURE LIGHTS ON HYD SYSTEM A CAME ON. SYS A QTY WENT TO 0. WE GOT EXTENDED VECTORS RAN QRH FOR LOSS OF SYSTEM A. RAN NON NORMAL LANDING DATA AND ALTERNATE EXTENDESDR UALA2012080704250Power Unit · leakingYELLOW-GREEN PTU LEAKING. REPLACED GREEN-YELLOW PTU. BLED SYSTEM AND CHECKED FOR LEAKS. CHECKED OK. OPS CHECK ACCOMPLISHED ON SMC 18.SDR UALA2012010600133Pump · underservicedRAT HYD PUMP IS UNDERSERVICED. REPLACED RAT PUMP.