| 1995 | 8 |
|---|---|
| 1996 | 6 |
| 1997 | 10 |
| 1998 | 8 |
| 1999 | 7 |
| 2000 | 8 |
| 2001 | 11 |
| 2002 | 11 |
| 2003 | 6 |
| 2004 | 9 |
| 2005 | 10 |
| 2006 | 9 |
| 2007 | 2 |
| 2008 | 1 |
| 2009 | 2 |
| 2010 | 1 |
| 2011 | 4 |
| 2012 | 4 |
| 2013 | 1 |
| 2014 | 2 |
| 2015 | 2 |
| 2016 | 3 |
| 2017 | 3 |
| 2018 | 1 |
| 2019 | 3 |
| 2020 | 2 |
| 2022 | 1 |
| 2023 | 2 |
| 2025 | 1 |
SDR SWAA2025032007746Pump · low pressureAFTER FLAPS 5 HYD A SYSTEM LOOW PRESSURE LIGHTS ON BOTH ENG AND ELECTRIC PUMP SHORTLY AFTER LOW PRESSURE LIGHTS ON HYD SYSTEM A CAME ON. SYS A QTY WENT TO 0. WE GOT EXTENDED VECTORS RAN QRH FOR LOSS OF SYSTEM A. RAN NON NORMAL LANDING DATA AND ALTERNATE EXTENDSDR DALA2023042003112Unknown · unknownSHIP 9512 -HYD/DE- THE RIGHT HYDRAULIC SYSTEM EXPERIENCED A COMPLETE LOSS OF FLUID WHILE ON APPROACH FOR LANDING. THE CREW DECLARED AN EMERGENCY WITH ATC AND THE ALTERNATE GEAR EXTENSION PROCEDURES WERE COMPLIED WITH. THE LANDING WAS UNEVENTFUL EXCEPT FOR THE SDR 2023F00067Pump · inoperativeHYDRAULIC SYSTEM "A" PUMP (ELECTRICAL N°2) WITH LOW PRESSURE. CORRECTIVE ACTION: HAS BEEN CHANGED PUMP. IN TEST NO FOUND DISCREPANCIES.