SDR SWI2023F00300Unknown · corrodedBELOW AFT BAGGAGE BAY FLOOR, AFT WATER DRAIN SURROUND CORROSION (C-CHECK RO 8/31/2023) REMOVED AND INSTALLED NEW CHANNEL REF CRJ 700 SRM 51-42-06-001-001-A01, CRJ700 SRM 51-45-00-001-001-A01, DWG-670-43255 REV-C. DWG MM670-43200 REV N , OPS CHECK GOOD,Jun 22, 2023 · N738SK · Cndair CL6002C10SDR DALA2022071404881Control Unit · inoperativeSHIP 3143 - DIV - TO MIA DUE TO FLIGHT CREW REPORT OF AIRFRAME VIBRATION FELT IN AFT FUSELAGE. VIBRATIONS LESSENED AT LOWER SPEEDS AND STOPPED AT 250KTS. CORRECTIVE ACTION: FOUND AFT DRAIN MAST HEATER C/B POPPED AND HEAVY ICE BUILDUP ON MAST. PLACED SYSTEM ON Jul 13, 2022 · N343NB · Airbus A319114SDR VNAA2018012511101Heater · defectiveAFTER PUSHBACK THE FA REPORTED TO THE CREW A BURNING SMELL IN THE GALLEY AREA. THE CREW RETURNED THE AIRCRAFT TO THE GATE FOR MAINTENANCE. GALLEY FAN IS SUSPECT AND THE AIRCRAFT IS CURRENTLY WAITING ON A MAINTENANCE INSPECTION. NO EMERGENCY. INSP GALLEY ,CABJan 25, 2018 · N549NN · Cndair CL6002D24SDR DALA2016022301310Drain Mast · corrodedELECTRONIC EQUIPMENT COMPARTMENT A LOWER DRAIN MAST IS CORRODED, FWD OF 218 BULKHEAD BETWEEN S27-S28R. VERIFIED DRAIN MAST DOUBLER WAS OUT OF LIMITS BY VISUAL INSPECTION. ZERO THICKNESS REMAINING. REMOVED 2 EA INTERCOSTALS TO GAIN ACCESS REMOVED DRAIN MAST ANFeb 21, 2016 · N894AT · Boeing 717200SDR CALA2013101692105Drain Mast · damagedHOT WATER DRAIN MAST DAMAGE AFT FUSELAGE. AFT DRAIN MAST DAMAGE FOUND ON ARRIVAL. REPLACED AFT DRAIN MAST ASSEMBLY.Oct 15, 2013 · N813UA · Airbus A319131SDR UALA2013053003752Shroud · crackedAFT DRAIN MAST OUTER SHROUD CRACK.May 29, 2013 · N815UA · Airbus A319131SDR UALA2013050903253Anti-Ice System · inoperativeAFT WASTE WATER DRAIN MAST HEATING SYSTEM(S) INOPERATIVE. SAMC COMMENTS: CIDS LIGHT ILLUMINATED.May 9, 2013 · N433UA · Airbus A320232SDR UALA2013043003007Heater · failedAFT DRAIN MAST FAILED ON CIDS. BITE TEST FAILED HEATER ELEMENT. REPLACED AFT DRAIN MAST HEATER IAW AMM 30-71-51-000-001. TESTS OK. NO ACTIVE FAULTS.Apr 28, 2013 · N453UA · Airbus A320232SDR SWIA201332724Ground Stud · corrodedGALLEY LINE HEATERS CIRCUIT BREAKER POPPED. INSPECTED GALLEY DRAIN MAST GROUND AND FOUND GROUND STUD N3525 SEVERELY CORRODED THROUGH RIB FS 333.0 AT THE 6 O'CLOCK POSITION. LEVEL 2 CORROSION. (SERVICE) REPLACED AFFECTED FRAME AT FS 333.0 BETWEEN STRS 25R AJan 31, 2013 · N962SW · Cndair CL6002B19SDR CA120928001Heater · failed(CAN) AFT GALLEY WATER TANK HEATING ELEMENT STAYED ON AND CAUSED THE SURROUNDING INSULATION BLANKET TO BURN AND CREATED SMOKE IN CABIN OF ACFT WHICH CAUSED A FLIGHT DIVERSION.Sep 21, 2012 · Cndair CL6012A12SDR UALA2012031301650Hose · brokenWATER AND ICE FOUND IN FWD CARGO PIT BELLY, UPON INSPECTING FOUND DRAIN LINE WITH HOLE FOR FWD DRAIN MAST SYSTEM. DF FWD DRAIN MAST IAW MEL. PCN 192-1608 IT4354-458. HOSE ASSY. DUE TO CREW REFUSAL OF AIRCRAFT WITH DF680, DF683. REMOVED BROKEN HOSE IN DRAIMar 13, 2012 · N771UA · Boeing 777222SDR UALA2012022701158Tape · burnedPLUMBING INSTALLATION SECT 43 DRAIN HOSE FOR B119 HEATER TAPE BURNED. REPLACED HEATER TAPE, OPS CHECK GOOD.Feb 25, 2012 · N641UA · Boeing 767322SDR UALA2012022701154Tape · burnedSECTION 43 DRAIN HOSE FOR B119 HEATER TAPE IS BURNED. ON NR 3811N01354 INSP 868 RMV AND RPL HEATER TAPE BN9 PLUMBING SEC 43 DRAIN HOSE IAW B767-300, OPS CHK GOOD.Feb 25, 2012 · N641UA · Boeing 767322SDR UALA2011110706020Tape · damagedTWO HEATER TAPES AROUND WATER SUPPLY LINE BURNT AND ARCING AT STA 808 - 1087. INSTALLED NEW HEATER TAPE, OPS CHECKS GOOD.Nov 6, 2011 · N643UA · Boeing 767322SDR ZKFR2011131600002Heater · inoperativeGALLEY DRAIN INOPERATIVE AT SINK AND COFFEE MAKER. FOUND HEATED DRAIN LINE IS NOT HEATING UP.Oct 16, 2011 · N78KN · Hawbee 4000SDR DXTA2011033004532Heater · inoperativeFUEL TRANSFER VALVE FROZEN INFLIGHT AT FL380. WORKS OK ON GROUND. REPLACED INOPERATIVE GALLEY DRAIN TUBE AND HEATER ASSY IAW MM 28-10-00. OPS TESTED GOOD.Mar 29, 2011 · N833QS · Raythn HAWKER800XPSDR UALA2011012800475Heater · faultedLAV TANK PRECHARGE IN TUBES HEAT BLANKETS B212 AND B213 WIRES ARC TUBES. REMOVED LAV TANKS. SENSORS ARE CORRODED. REPLACED B212 AND B213 WASTE TANK SVCE FITTING HEATERS REF WD AND SSM.Jan 28, 2011 · N676UA · Boeing 767322SDR ASOA201000432Drain Mast · inoperativeSMELL OF SMOKE/ELECTRICAL IN GALLEY. REMOVED AND REPLACED FWD HEATED DRAIN MAST IAW AMM 38-32-11, OPS CHECK GOOD. DMIL CLEARED, PLACARD REMOVED. R & R FWD HEATED DRAIN MAST IAW AMM 38-32-11, OPS CHECK GOOD. DMIL CLEARED, PLACARD REMOVED.Mar 26, 2010 · N317CA · Cndair CL6002C10SDR CA100119002Deice System · failed(CAN) UPON RETURN FROM FLIGHT, HEATED DRAIN MAST WAS COVERED OVER WITH ICE INDICATING THAT IT WAS NOT FUNCTIONING IN FLIGHT. WHEN THE ACFT WAS PLACED IN THE HANGAR, ELECTRICAL POWER APPLIED AND THE SKIN REMAINED BELOW 45 DEG AND ALLOWED ELECTRICAL CURRENT TO Jan 18, 2010 · Cndair CL604SDR USAA20091113BA061Unknown · malfunctionedPHL - CIDS PANEL DISPLAYS WASTE WATER ICE PROTECTION INOP - MAINT REQUIRED. TROUBLESHOT, FOUND IPCU 16DS FAULTED ON BITE CHECK. IPCU 16DS CONTROLS 3L/3R AND 4L/4R DOOR SLIDE ATTACH HEATERS - SLIDE LOCKING MECHANISM ICE PROTECTION INOP. CHECKED ALL FUSES. NNov 12, 2009 · N280AY · Airbus A330243SDR DJFA2009037Element · burnedDURING TROUBLESHOOTING OF AN UNRELATED DISCREPANCY, MX SMELLED BURNING ODOR. UPON FURTHER INSP, MX FOUND THE GALLEY DRAIN MAST ON FIRE. THE FIRE WAS EXTINGUISHED. MX FOUND THE FIBERGLASS HEATING ELEMENT HAD OVERHEATED AND CAUGHT ON FIRE. MX REPLACED THE HEOct 4, 2009 · N700LX · Cessna 750SDR DXTA2009090903780Heater · overtempFORWARD GALLEY DRAIN HEATER OVER TEMPED MELTING GROMMET AND DISCOLORING FILLET FAIRING. REMOVED & REPLACED DRAIN HEATER IAW MM 38-30-02. OPS & DRAIN CHECKS GOOD.Sep 3, 2009 · N903QS · Cessna 750SDR CA080623006Heat Tape · burned(CAN) DURING THE 96 MONTH INSPECTION ON ACFT BURNED HEAT TAPE PART NR 3043-10 AND 3043-15 WAS DISCOVERED. THIS TAPE WAS INSTALLED UNDER A DRAWING NR 34-260W011 ON THE AFT WATER SYSTEM LINES (AFT CABIN). THE SURROUNDING INSULATION AND AFFECTED PIPING WAS DEEPLYJun 20, 2008 · Cndair CL604SDR DLM90080718Heater · shortedWASTE OVBD VENT TEE HEATER SHORTED OUT AND BURNT A 3 INCH HOLE IN THE TEE THEN THE A/C COULD NOT PRESSURIZE WITH 1 PACK.May 10, 2008 · N908DA · Doug MD9030SDR 2008UALA00389Drain Mast · shortedAFTER T/O CABIN CREW IN AFT GALLEY SMELLED ELEC BURN SMELL. AFT GALLEY ODOR DISSIPATED IN A COUPLE MINUTES. NOTICED AFT GALLEY DRAIN C/B POPPED OVERHEAD PNL. GALLEY DRAIN MAST SHORTED. REPLACED GALLEY DRAIN MAST, OPS CHECKED NORMAL.Jan 23, 2008 · N810UA · Airbus A319131SDR CA080805004Heat Tape · burned(CAN) THE AFT WATER SUPPLY HEATER TAPE OVERHEATED AND BURNED. INVESTIGATION REVEALED WATER HEATER WAS RUNNING WITHOUT TEMP REGULATION. HEATER WAS REPLACED.Sep 1, 2007 · Cndair CL6002B19SDR ZZDA070123131Drain Mast · damagedAIRCRAFT LEFT TAXI WAY NOSE GEAR STUCK IN MUD. DRAIN MAST DAMAGED. REPLACED DRAIN MAST PER 717 AMM CHAPTER 30-72-02 REV 27 DATED 01/01/07.Jan 23, 2007 · N956AT · Boeing 717200SDR CA041216002Connector · burned(CAN) FOLLOWING A DISCREPANCY WITH THE LAVATORY DRAINING, MAINTENANCE FOUND THE HEATER ASSY FOR STATIC VENTILATION (REAR DRAIN MAST) NOT WORKING. ONE OF THE 2 CONNECTORS AT THE HEATER WAS FOUND BURNED. THE INSULATION BLANKET AROUND THE HEATER WAS FOUND CARBDec 13, 2004 · Fokker F28MK0100SDR AALA20040571Tape · burnedAFW - HEATER TAPE FOR WATER OR DRAIN LINE WAS BURNT IN HALF. INSULATION WRAPPER WAS SLIGHTLY CHARRED. WATER AND DRAIN LINE ARE WRAPPED TOGETHER WITH 2 RIBBONS (PART NUMBER 304311040280 MFR COX AND COMPANY), AREA WAS .5 INCH BY 16 INCHES AT AFT CARGO AT STATIApr 30, 2004 · N381AN · Boeing 767323SDR CA031218005Ribbon Heater · burned(CAN) DURING THE CURRENT MAINT VISIT ON VA704 A BURNED HEATER TAPE HAS BEEN DISCOVERED. THE 7.1 FOOT LONG DRAIN LINE ELEMENT IS THE HEATER B193 (COX P/N 3051-01 MODEL 110-7.1-71) LOCATED AT BSTA 1560, WL 174, RBL 62. IN THIS CASE, HEATER AND PROTECTIVE TAPE EXDec 4, 2003 · Boeing 767233SDR 02FDEA00518Heater · sparksSPARK FOUND EMITTING FROM THE FORWARD WASTE DRAIN HEATER AT FORWARD AVIONICS COMPARTMENT SIDE, WHEN POWER SWITCHED ON.Jul 23, 2002 · N608FE · Doug MD11SDR DLM88020225Heater · shortedSMOKE REPORTED ON APPROACH TO ATL IN AFT LT LAV. FOUND AFT LT LAV WATERLINE HEATER SHORTED CAUSING TEFLON TAPE TO MELT. REPLACED HEATER.Feb 24, 2002 · N949DL · Doug MD88SDR MWEA020130Circuit Breaker · faultySHORTLY AFTER TAKEOFF, NR 2 PFD AND NR 2 ND FAILED FOLLOWED BY SYMBOL GENERATOR NR 2 CB OPENING. FOUND PROBLEM CAUSED BY INOP FORWARD DRAIN MAST HEATER. DRIED MOISTURE AND REPLACED SYMBOL GENERATOR. REPLACED FORWARD GALLEY MAST CIRCUIT BREAKER B1-509.Feb 16, 2002 · N812ME · Doug DC981SDR MWEA011407Heater · malfunctionedAIRCRAFT WAS PARKED ON TAXI-WAY AWAITING GATE. AFTER 10 MINUTES, THE FORWARD WATER SYSTEM FREEZE PROTECTION SYSTEM C/B POPPED. TWO MINUTES THEREAFTER, THE F/A'S NOTICED A LIGHT SMOKE IN CABIN, EVACUATION CHECKLIST WAS PERFORMED. AIRCRAFT WAS EVACUATED VIA TOct 17, 2001 · N807ME · Doug DC981SDR 2001F00204Drain Mast · overtempPTK - FLT 1647 - AFT WATER SYSTEM DRAIN MAST HEATER SHOWS SIGNS OF OVERHEATING. DRAIN MAST HEATER ELEMENT OVERTEMP. REPLACED DRAIN MAST ASSEMBLY WITH NEW UNIT. (M)Jul 19, 2001 · N940DC · Gulstm GIVSDR 99UAL900211Heat Tape · failedFLIGHT ATTENDANT REPORTED SMOKE IN CABIN/COCKPIT AREA, NOTIFIED MAINTENANCE. *S/D* HEATER TAPE B109 FAILED CAUSING INSULATION ON FORWARD GALLEY CHILLER DUCT TO IGNITE. 767 ENGINEERING ISSUED CALLOUT TO INSPECT 767 AIRCRAFT WITH THIS HEATER TAPE CONFIGURATIONApr 14, 1999 · N618UA · Boeing 767222SDR ASAA9780111Heating Element · burnedOAK - AFTER ARRIVAL AT GATE OF FLT 102, CREW REPORTED SMOKE IN THE RT AFT LAVATORY. FOUND POTABLE WATER LINE HEATING ELEMENT BURNED UNDER RT AFT LAVATORY SINK. SECURED ELEMENT, PULLED AND COLLARED AFFECTED CIRCUIT BREAKER'S AND SHUT OFF WATER TO SINK. REPLAJun 8, 1997 · N954AS · Doug DC982SDR DLL15961655Switch Panel · failedON GROUND, WASTE/WATER PANEL AFT 1 AND AFT 2 SWITCH LIGHT SHORTED OUT CAUSING FLAME AND SMOKE. USED HALON BOTTLE, SWITCH 217201153 FAULTED. REPLACED PANEL (P/N 3170001240).Jul 9, 1996 · N752DA · Lkheed 10113853SDR USAA950302Line · dirtyCLT - FLT NR 0275 - CREW REPORTED FUMES IN COCKPIT. OXYGEN MASKS WERE USED AND AN EMERGENCY WAS DECLARED. MAINTENANCE CLEANED THE ANTI-ICE FLUID LINE AND ELBOW AT SOLENOID, FIRST OFFICERS SIDES. OPERATIONS CHECKED GOOD. (W)Apr 1, 1995 · N972VJ · Doug DC931
Back to JASC 3070