What it covers
The system that is used for prevention of ice in water supply and drain lines.
Service difficulty reports · 39
Reports filed under 3070, newest first.
| 1995 | 1 |
|---|---|
| 1996 | 1 |
| 1997 | 1 |
| 1999 | 1 |
| 2001 | 2 |
| 2002 | 3 |
| 2003 | 1 |
| 2004 | 2 |
| 2007 | 2 |
| 2008 | 3 |
| 2009 | 3 |
| 2010 | 2 |
| 2011 | 4 |
| 2012 | 4 |
| 2013 | 5 |
| 2016 | 1 |
| 2018 | 1 |
| 2022 | 1 |
| 2023 | 1 |
SDR SWI2023F00300Unknown · corrodedBELOW AFT BAGGAGE BAY FLOOR, AFT WATER DRAIN SURROUND CORROSION (C-CHECK RO 8/31/2023) REMOVED AND INSTALLED NEW CHANNEL REF CRJ 700 SRM 51-42-06-001-001-A01, CRJ700 SRM 51-45-00-001-001-A01, DWG-670-43255 REV-C. DWG MM670-43200 REV N , OPS CHECK GOOD,SDR DALA2022071404881Control Unit · inoperativeSHIP 3143 - DIV - TO MIA DUE TO FLIGHT CREW REPORT OF AIRFRAME VIBRATION FELT IN AFT FUSELAGE. VIBRATIONS LESSENED AT LOWER SPEEDS AND STOPPED AT 250KTS. CORRECTIVE ACTION: FOUND AFT DRAIN MAST HEATER C/B POPPED AND HEAVY ICE BUILDUP ON MAST. PLACED SYSTEM ON SDR VNAA2018012511101Heater · defectiveAFTER PUSHBACK THE FA REPORTED TO THE CREW A BURNING SMELL IN THE GALLEY AREA. THE CREW RETURNED THE AIRCRAFT TO THE GATE FOR MAINTENANCE. GALLEY FAN IS SUSPECT AND THE AIRCRAFT IS CURRENTLY WAITING ON A MAINTENANCE INSPECTION. NO EMERGENCY. INSP GALLEY ,CAB