Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101920447Light · intermittentELECTRICAL BURNING ODOR AROUND ROW 15C. RAN SMOKE FIRE FUMES CHECKLIST. ODOR PERSISTED. CONDITIONAL INSPECTION (EC0500-01055A) IAW 05-51-56/201 AND AMM 05-51-56-940-801-C1. LT & RT RECIRC FAN FILTERS REPLACED IAW AMM 21-25-02-004-001-002 & 21-25-02-404-008-00SDR CALA2026100720183Battery Pack · no testBATTERY CAPACITY CHECK FAILED. EMERGENCY LIGHT BATTERY PACK M33424, REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.SDR IPXA2026092532696Battery Pack · unknownEMERGENCY LIGHT BATTERY PACK IN SPARE BULB COMPARTMENT MISSING DUE DATE PLACARD. REMOVED AND REPLACED BATTERY PACK ASSY WITH NEW DUE DATE STICKER PER AMM 33-51-07. OPS CHECKS NORMAL.SDR CALA2026092419777Switch · intermittentNO SMOKING AND EMERGENCY EXIT SIGNS NOT WORKING PROPERLY IN AUTO. COMPLIED WITH DDP COMPLIED WITH DDP DM WORK WITH MEL LP 3349297. SUSPECT ISSUES RELATED. PERFORMED OPS TEST FOR EMERGENCY LIGHTS IAW AMM 33-51-00-710-804-A. FOUND NO SMOKING SWITCH 190RH INTSDR KCSA2026070337Ballast · inoperativeOPBC L STATUS MSG. PERFORMED FIM 23-93 TASK 844 IAW FIM. MSG CLEARED. SYSTEM OP’S NORMAL.SDR R61A2026063000183Battery · no testEMERGENCY LIGHT BATTERY FAILED FUNCTIONAL CHECK. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY.SDR CALA2026050716065Battery · no testL4 DOOR, M33407 EMER LIGHT BATTERY CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR SWIA2026040875681Ballast · burnedELECTRICAL BURNING SMELL IN BACK MID WAY THRU CABIN, NO SMOKE (FLIGHT 4055). TROUBLESHOT "ELECTRICAL BURNING SMELL IN BACK MID WAY THRU CABIN, NO SMOKE" IN REF TO CRJ 900 FIM 21-22-00. FOUND SIDEWALL LIGHT BALLAST AT SEAT 9AB TO HAVE A BURNT RESISTOR CAUSINGSDR CALA2026040715186Ballast · failedFLT ATTENDANTS REPORTED SMELL OF PLASTIC BURN IN B ZONE GALLEY UNABLE TO GET DEBRIEFED BY PILOTS. FA WORKING MID GALLEY AREA WAS DEBRIEFED. HER STATEMENT WAS PLASTIC/ELECTRIC SMELL WAS LOCALIZED IN THE L2 DOOR ONLY. (LIGHT ABOVE L2 DOOR). SHE STATED NO SMELL ISDR CALA2026040315059Light · illuminatedFWD ENTRY DOOR LIGHT IN OVRHEAD CAME ON DURING LANDING. ITEM PLACED ON MEL, INDICATION ONLY. REF FIM 52-10 TSK 801 & WDM 52-71-11-4. PARTS UPDATED. FOLLOWING FIM 52-10 TASK 801 PERFORMED ADJUSTMENT OF FWD ENTRY DOOR INDICATION SENSOR (S199) IAW AMM 52-71-11-SDR YENA2026022300230Lamp · burnedFLT # 1371 LGA-FLL. "SMOKY SMELL IN AFT GALLY ON ARR F3 REPORTED AFTER LIGHTS TURNS OFF SMELL WENT AWAY.; INSPECTED AND FOUND NO SMOKEY SMELL FROM AFT GALLEY LIGHTS OPERATING FOUND AFT DOOR L2 ENTRY DOOR LAMP BURNT. REMOVED AND REPLACED BOTH BALLAST UNIT & LASDR DALA2026011400339Light · burned outC/B FWD MAINT LT POWER 1 TRIPPED. T/S FOUND BREAKER CDC3-4-10 POPPING FOUND OXYGEN MAINT LIGHT BURNED OUT AND CHARRED. R/R OXYGEN MAINT LIGHT PER A220 AMP 33-32 -15. PERFORMED OPS CHECK. OPS CHECK NORMAL AT THIS TIME. (LP# 8195376)SDR CALA2026010612691Switch · faultedLAV E EMERGENCY LIGHT STUCK ON UPON ARRIVAL TO AC FA REPORTS LAV E CALL LIGHT COULD NOT BE EXTINGUISHED. FOUND CALL SWITCH STICKING WHEN PRESSED. REPLACED LAV E CALL SWITCH. LIGHT AND SWITCH BOTH OPERATE NORMALLY AT THIS TIME. REF AMM 33-27-00-960-802SDR CALA2025111811314Light · no discrepancyAFT FA EMERGENCY CALL LIGHT FLICKERED ON/OFF. TESTED AFT FA EMERGENCY CALL LIGHT, LIGHT NOT FLICKERING. NO DEFECT NOTED.SDR N6WA2025111203Ballast · failedSMOKE/FUMES COMING FROM 1C OVERHEAD BIN (AIRCRAFT IS IN SBM) (CLIMB PASSING THRU 220, NO MEDICAL ATTENTION REQUIRED). DEFERRED BALLAST AT 1CD IAW MEL 33-21-01A CAT C OCN 70095855SDR SWIA2025102000019Ballast · failedON DECENT PASSENGERS MENTIONED A BURNT ORDER. CONFIRMED BY THE FLIGHT ATTENDANT. PASSENGERS IN ROW 16 COMPLAINED THAT THE FLOOR WAS €ŒREALLY HOT€? AT THE SAME TIME. AFTER DEPLANING THE SMELL REMAINED. (FLIGHT 6468) APON ARRIVAL TO ACFT COULD SMELL A SLIGHTSDR DXTA2025101305257Power Supply · defectiveTHE LIGHTS WERE FLASHING ALL OVER THE COCKPIT, AND LATER THERE WAS A BURNING ELECTRICAL SMELL. WE SHUT DOWN THE AIRPLANE QUICKLY. CORRECTIVE ACTION: GAINED ACCESS TO AIRCRAFT, REVIEWED FOOTAGE OF DISCREPANCY AND SPOKE WITH MCC ABOUT ISSUE. MCC STATED LIKELY TSDR CALA2025100609615Guard · brokenFLIGHT DECK EMERGENCY LIGHT SWITCH GUARD ON P5 PANEL BROKEN. IPC 33-51-00-02 ITEM 15 REPLACED EMERGENCY LIGHT SWITCH GUARD REF IPC 33-51-00-02 ITEM 15. PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHTS REF 33-51-00AMM. OPS CHECK GOOD.PARTS USED: 29-3351-3-0037,SDR CALA2025090908674Contact · shortedGATE RETURN, WHEN SETTING TAKE OFF PWR ADIRU LIGHTS ILLUMINATED , MCP FLICKERED FOLLOWED WITH NUMEROUS WARNING LIGHTS ILLUMINATED ON THE OVERHEAD PANEL. TOMC ADVISED GATE RETURN MCP ALL LIGHTS ON. ALSO NUMBERS FLASHING 8 ON DISPLAY WINDOWS. FIRE PANEL SHOWING SDR CALA2025090508495Cids · faultedEMER EXIT SIGN ON OVER WING AND OVER MCD STAYS ILLUMINATED ALL OTHER LTS REMAIN EXTIGUISHED TURNED OFF EMEGENCY LIGHT SWITCH AND PERFORMED FULL CIDS SYSTEM RESET. EMERGENCY LIGHTS EXTINGUISHED. CYCLED SWITCH IN ALL POSITIONS 3 TIMES. ALL EMERGENCY LIGHTS NOW OSDR HNAA2025082500580Control Module · odorLH SIDEWALL LIGHTS AFT OF 2A INOP. WITH ELECTRICAL BURNING SMELL. R & R CONTROL MODULE ASY IAW AMM 33-21-01 OPS CHECK IAW AMM 33-21-01A/C OK FOR SERVICE.SDR ASAA2025082160364Control Panel · detachedMASTER CALL LIGHT PANEL IN FWD GALLEY CEILING FELL OFF. GROUNDED - YES. REPLACED MASTER CALL/EXIT SING LIGHT ASSY REF CMM 33-51-01. OPS CHECKS GOOD. INT CLEARD. PLACARD REMOVED.SDR CALA2025081807872Lens · faultedEMERGENCY LIGHT 4R INOPERATIVE, EMERGENCY LIGHT AT DOOR 4R CHECKED NORMAL, ACTUAL DISCREPANCY WAS RJ DOOR LAVATORY CALL LIGHT STUCK, REPLACED CALL LIGHT LENS OPS CHECK NORMAL AT THIS TIME.SDR WX0A2025072532513Battery · no test(AIRCRAFT NOT GROUNDED) BATTERY FAULT INDICATION DURING EPSU BITE TEST / REMOVED AND REPLACED EPSU BATTERIES, REF WO519197"SDR CALA2025060605325Ballast · odorSUSPICIOUS ODOR REPORTED DURING INITIAL CLIMB BY B ZONE FAS. DIS APATED CREW DEBRIEF: CAPT STATED SMELL APPEARED DURING CLIMB BUT DISSIPATED. THEY LEVELED OFF AT FL300 FOR AN HOUR THEN CLIMMBED AGAIN TO FL330, SMELL BRIEFLY CAME BACK AND LEFT AGAIN. PER FA'S, SDR CALA2025053005121Power Supply · failedEMERGENCY LIGHT BATTERY PACK FOR SEATS 22ABC TO 30ABC FLOOR PROXIMITY LIGHTS IS WEAK. SUPPORT TASK NSA EMX NR 00053 COMPLETED SDR BATTERY PACK DIDNT FIX THE ISSUE REFRENCE LP # 5010177 REMOVED AND REPLACED EMERGENCY POWER SUPPLY-BATTERY PACK AT M167 0 IAW AMM SDR CALA2024120303012Battery · no testDR 3R M33401 EMER LIGHT BATTERY TEST FAIL. EMER LIGHT BATTERY REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2024111102821Battery Pack · no testB777-33-3-7019 CABIN - R/H DOOR NO.4 EMERGENCY LIGHT BATTERY PACK (M33408) CAPACITY CHECK FAILED. R/H DR4 EMERGENCY LT BATTERY PACK (M33408) REPLACED AND TEST NORMAL AS PER AMM 33-51-00.SDR CALA2024082900509Battery · no testDR 2R O/H FWD (M33097) BATTERY FND TEST FAILED TRANSFER REF NON - ROUTINE WO.3676780 AND ORIG BY V926672 DR 2R O/H FWD (M33097) BATTERY AND EMER PWR SUPPLY REPLACED AND TEST NORMAL IAW AMM33-51-06 WORK ACCOMP BY MECH V926672 AND INSP BY V924743 IDT APPROVED BYSDR CALA2024081200402Control Panel · unserviceableSMOKE AND FUMES IN FD WHEN TAKING RWY. AIRCRAFT BACK TO STAND AS SMIKE IN THE COCKPIT NOTICED - FOUND C B N6 OVERHEAD PANEL POPPED, WITH STRONG ELECTRICAL SMELL IN THE COCKPIT.SMELL NOTICED COMING OUT THE L BOTTOM OVHD PANEL, NEAR L RUNWAY TURNOFF LIGHT CTL SWSDR DALA2024071607191Lamp · inoperative(LOG 5310886) 5 EMERGENCY ESCAPE HATCH HANDLE LAMPS INOPERATIVE. RELAMPED DISCREPANT EMERGENCY ESCAPE HATCH HANDLE LIGHTS PER B737 AMM 33-51.SDR CALA2024053101650Battery Pack · dischargedEMERGENCY EPSU BATTERY AFT L FAILS OPERATIONAL CHECK. REF TO PEMCO NR 15402.0026 REMOVED AND REPLACED EPSU BATTERY AT 13WL IAW A319 AMM 33-51-38- 000-002-A AND A319 AMM 33-51-38-400-002-A. OPERATIONAL TEST GOOD IAW A319 AMM 33-51-00-710-001-ASDR CALA2024052001537Light · inoperativeENTRY LIGHT DOES NOT TURN ON FWD CABIN OHD STWG CREW REPORTED FWD CEILING LIGHTS DON''T GO TO BRIGHT, PLACARDED PLACARDED FWD CABIN CEILING LIGHTS NOT GOING TO BRIGHT PER MEL NUMBERS. THX DM CEING LIGHTS INOP PER MEL 3302B 3302B APPROVED *DM* IF UNABLE TO RESOSDR CALA2024041901149Battery Pack · no testDR 2L M33099 EMER LIGHT BATTERY CHARGER TEST FAIL - TRANSFER REFER NON-ROUTINE WO.3041425 - AND ORIGINATED BY EMP DR 2L M33099 EMER LIGHT BATT CHARGER REPLACED AND TESTED NORMAL I.A.W AMM33-51-06 ATTACHED FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED BY MECH AND INSPESDR CALA2024041901145Battery Pack · no testB777-33-3-7019 - DR 4L M33407 EMER LIGHT BATTERY TEST FAIL TRANSFER REFER - NONROUTINE WO.3041433 AND ORIGINATED BY. DR 4L M33407 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACHED FORM 44-0008 ITEM 1 TO 2.SDR YENA2024041100515Cids · warning messageFLT#34, CDG-BOS. (ETOPS) 'CIDS CAUTION ON FAP ( FLIGHT ATTENDANT PANEL (FAP) 10) OTHER FUNCTIONS (ON FAP) ) PAX CALL LIGHT SEAT 6 RIGHT,' (SUPPLEMENTAL INFORMATION TO FOLLOW)SDR CALA2024031800766Battery Pack · no testB777-33-3-7019 - DR L3 M33406 EMER LIGHT BATTERY TEST FAIL TRANSFER REFER NON-ROUTINE WO.2913795 AND ORIGINATED BY DR L3 M33406 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 ATTACH FORM 44-0008 ITEM 1TO 2.SDR UIEA2024030100140Lamp · brokenFOUND EMERGENCY LIGHTS L5735, L1853 AND L1854 LAMP BROKEN(<P>EMERGENCY LIGHTS L5735, L1853 AND L1854 LAMP REPLACED AND TEST IS NORMAL IAW AMM 33-51-00</P>)SDR CALA2024022600532Battery Pack · no testALL EMERGENCY LIGHT BATTERY PACKS FAILED CAPACITY TEST. (M02816 REF TO PEMCO NR 14647.0043. REMOVED AND REPLACED BATTERY PACK LOCATION M02816, IAW B737 AMM 33-51-06-960-805. OPS CHECK OK.SDR CALA2024011500110Battery Pack · dischargedCTR PAX SEAT 30 TO 37 FLOOR PROXIMITY EMER LT FOUND DIM (BAT EQ#M732) TRANSFER REF. NON-ROUTINE HX NRC WO.2709101 AND CABIN EMER LT BAT PACK EQ#M732 REPLACED AND INSTALLATION TEST ATTACHED FORM 44.0008 ITEM 1-2 ACCOMPLISHED WORK ACCOMPLISHED CARRIED OUT RESULSDR CALA2023122603735Battery Pack · no testCABIN DOOR L4 EMER LT POWER PACK M33407 CAPACITY CHK FAIL REF HX NR WO.2594346, CABIN L4 EMER LT BATTERY PACK M33407 REPLACED AND INSTALLATION T EST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06.SDR CALA2023121303635Lens · wrong partF/A SAYS EMER EXIT SIGN OVER ROW 1 - DOES NOTHAVE REQUIRED ARROW S REMOVED AND REPLACED CABIN ROW 1 OVERHEAD EXIT LENS .REF ASM 33-51-01-15G. INSPECTED LIGHT SHADE, CK''D INSTALLATION AND SECURITY REF GMM 09-10-05.SDR CALA2023120103525Battery Pack · failedREMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACKS AT MULTIPLE LOCATIONS IAW AMM 33-51-06. OPS CHECK GOOD. REF TO PEMCO NR 14390.0028 (S/N 249215) REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACKS AT MUTIPLE LOCATIONS IAW B737 AMM 33-51-06. OPS TEST GOOD. (S/SDR IPXA2023112058316Unknown · unknownEMER PWR TST FAIL FOLLOWED FIM 24-30-03-00 AND PERFORMED THE OPS TEST OF THE BATTERIES IAW AMM 24-34-02. TEST OK.SDR DALA2023110709175Unknown · unknownSHIP 1606 LEFT CABIN READING/CALL LIGHTS STROBING ON/OFF. METAL SMELL AROUND ROW 20. DISAPATED AFTER POWER REMOVED. CORRECTIVE ACTION: CAN'T DUPLICATE FAULT. INSPECTED PSU AND LED LIGHT CONNECTORS. NO FAULTS. OK FOR SERVICE PER B767 AMM 33-25. (5057804)SDR KCSA202311021131Cover · brokenMDSS BLUE LIGHT COVER IS BROKENSDR CALA2023103003226Battery Pack · dischargedEMER LT BATTERY PACK (M33099) AT DR 2L FOUND CAPACITY FUNCTIONAL CHECK FAIL REF HX NR WO.2295826, ORIG BY V920586 EMER LT BATTERY PACK AT DR 2L REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 (M33099)SDR DALA2023101608496Unknown · unknownSHIP 3314 DOOR 604 CABIN PRESSURE LIGHT COVER NOT ATTACHED. CORRECTIVE ACTION: REINSTALLED COVER. (0019533)SDR DALA2023091107427Unknown · unknownSHIP 3360 OVERHEAD PANEL EXT LIGHT TO ANN LIGHT THAT SECTION OF THE INTEGRAL LIGHT FELL DOWN. CORRECTIVE ACTION: ADJUSTED. (4556434)SDR CALA2023082502636Module · faultyMACH TRIM FAIL LIGHT DOES NOT ILLUMINATE WITH MASTER LIGHT TEST. PERFORMED BITE LIBRARY TEST 33 MACH TRIM IAW AMM TRIM FAIL LIGHT ILLUMINATES. APPLIED MEL 3316Z REQUESTING APPROVED BY TOMC. 22-11-00-740-801 ON CHANNEL A AND B OPERATIONAL TEST GOOD MACH RELIEF.
Back to JASC 3300