Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023033100934Light · crackedEY SEAT ROW 34DEF EMERGENCY LIGHT FOUND CRACKED.AFTER MOD NEW PO S IS 33DEF REF HAECO NON-ROUTINE NO.9408842 - ORIGINATED BY EMP V903178 SPEC NO.B767-33-3-7000 PERFORMED BY EMP V903178 REPLACE SEAT ROW 33DEF EPL LIGHT AND OP S CHECKED,THE RESULT FOUND ''SATIS'SDR AALA202304140641Diode · faultyAIRCRAFT WAS NOT GROUNDED: ON APPROACH TRAILING EDGE FLAP EXTENDED ON SCHEDULE (30DEG) LEADING EDGE DEVICES SHOWED NO "LE FLAPS TRANSIT" OR "LE FLAPS EXT" AT ANY TIME. AIRCRAFT DIVERTED TO JFK AND DECLARED AN EMERGENCY. **SUPPLEMENTAL REPORT FOR AALA2023033106SDR AALA202304144019Diode · looseAIRCRAFT WAS NOT GROUNDED: ON APPROACH TRAILING EDGE FLAP EXTENDED ON SCHEDULE (30DEG) LEADING EDGE DEVICES SHOWED NO "LE FLAPS TRANSIT" OR "LE FLAPS EXT" AT ANY TIME. AIRCRAFT DIVERTED TO JFK AND DECLARED AN EMERGENCY. **SUPPLEMENTAL REPORT FOR AALA2023033106SDR AALA202303310641Unknown · unknownAIRCRAFT WAS NOT GROUNDED: ON APPROACH TRAILING EDGE FLAP EXTENDED ON SCHEDULE (30DEG) LEADING EDGE DEVICES SHOWED NO "LE FLAPS TRANSIT" OR "LE FLAPS EXT" AT ANY TIME. AIRCRAFT DIVERTED TO JFK AND DECLARED AN EMERGENCY. **SUPPLEMENTAL REPORT REQUIRED** (OPEN)SDR CALA2023033100933Lamp · inoperativeDOOR 2R EXTERIOR EMERGENCY SLIDE LIGHT INOPERATIVE REFER HAECO NON-ROUTINE NO.9450736 - ORIGINATED BY EMP V903172, SPEC NO.B777-33-3-7019 PERFORMED BY EMP V903172 ON HAECO NON-ROUTINE LP9450736 REPLACED THE NO.2 DOOR RIGHT EMERGENCY SLIDE LIGHT LAMP BULB AND OSDR CALA2023032900918Panel · inoperativeFWD ATTENDANT PANEL EMERGENCY LIGHT SWITCH GUIDE FOUND WEAK REF HAECO NON-ROUTINE NO.9407346 - ORIGINATED BY EMP V903178 SPEC NO . MULT-33-3-0004 PERFORMED BY EMP V903178 REPLACED FWD ATTENDANT PANEL EMERGENCY LIGHT SWITCH GUIDE AND CONDITION CHECKED,THE RESULSDR DXTA2023032883310Unknown · unknownEMERGENCY LIGHTS FLICKER INFLIGHT AND REMAIN ON WITH THE SWITCH SET TO ARM. R/R FWD AND AFT EMERGENCY LIGHT BATTERY PACKS IAW PHENOM 300 AMM 33-52-01. OPS CHECK OK.SDR UIEA2023032300279Lamp · unknownEMERGENCY LIGHT INERTIA REEL LT FOUND INOP(<P>LAMP REPLACED AND OPERATION TEST NORMAL </P>)SDR CALA2023032700888Bulb · inoperativeTHE G5 FWD L/H CEILING PANEL EMERGENCY LT INOP, REFER TO N0110 REPLACED THE G5 FWD L/H CEILING PANEL EMERGENCY LT BULB, THE TES T RESULT IS NORMAL AS PER AMM 33-51-05 R138.SDR CALA2023032700887Bulb · inoperativeSEAT 1A CEILING EMERGENCY LIGHT INOP, REFER TO N0109 REPLACED SEAT 1A CEILING EMERGENCY LIGHT BULB, THE TEST RESULT I S NORMAL AS PER AMM 33-51-05 R138, WORK ACCOMPLISHED BY V913662SDR CALA2023032400860Connector · damagedCEILING PANEL EMERGENCY LIGHT CONNECTORS DAMAGE AT 2A-3A,5A,7A, 9A,2L,4L,6L,8L REF HAECO NON-ROUTINE NO:9407991 - ORIGINATED BY EMP V905488, EA 4420-03294 REV OP 001. PERFORMED BY EMP V9407991,REPLACED CEILING PANEL EMEGENCY LIGHT CONNECTORS AT 2A-3A,5A,7A,9A,SDR CALA2023032400859Connector · crackedCEILING PANEL EMERGENCY LIGHT CONNECTORS DAMAGE AT 17AB,19AB,30A B,19LK,27LK,30LK,32LK REF HAECO NON-ROUTINE NO:9408796 - ORIGINA TED BY EMP V905488,EA 4420-03294 REV C OP 001. PERFORMED BY EMP V905488,REPLACED CEILING PANEL EMERGENCY LIGHT CONNECTORS AT 17AB,SDR CALA2023032400858Light · unknownSEAT 37D EMERGENCY LIGHT INOP, REFER TO BSH N0107 REPLACED THE 37D EMER LT ASSY AS PER AAMM 33-51-10 R138 INSTALLA TION TEST TRANSFER TO N0545, WORK ACCOMPLISHED V913662SDR CALA2023032400842Lens · unknownEXTERIOR LIGHT OPERATIONAL CHECK {B767-33-3-0008} - RIGHT OUTBOARD LOGO LIGHT & BOTH LEFT LOGO LIGHTS ARE OUT. REQUEST ITEM TO BE PLACED ON MEL 3345A. ITEM PLACED ON MEL 3345A. LOGO LIGHTS INOP COVER. CLEANED OUTER LOGO LIGHT ASSEMBLY ON LEFT STABILIZER AND ASSDR CALA2023032200820Battery Pack · inoperativeL2 DOOR EXIT SIGN INOP (REF. AAR NR 99960646) REPLACED L2 DOOR EXIT SIGN AND BATTERY PACK M1673 IAW B737 AMM33-51-01-960-801 & 33-51-06-960-805, TEST GOOD (WORKACCOMPLISHED BY V936916 AND AAR QC A-78 V768499) SDR#1031695SDR WX0A2023032231739Epsu · unknownEPSU BATTERY (13WL) FAILED SYST. TEST REQS REPLACEMENT / R/R EPSU BATTERY (13WL) IAW AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A, OPS CHECK GOOD."SDR CALA2023032000806Battery Pack · inoperativeR2 FWD ESCAPE INTERIOR OVERWING LIGHT INOP (REF. AAR NR 9960647).SDR CALA2023032000802Battery · failedB777-33-3-7019 CABIN EMER LT DEEP CYCLE CAPACITY TEST FOUND R2 DR (M33097) BATTERY FAIL. TRANSFER REF NON - ROUTINE WO.1578450 AND ORIG BY V897794 R2 DR BATTERY (M33097) REPLACED AND TEST NORMAL AS PER AMM23-51-06 WORK ACCOMP BY MECH V920572 AND INSP BY V92699SDR CALA2023032000801Battery · failedB777-33-3-7019 CABIN EMER LT DEEP CYCLE CAPACITY TEST FOUND L5 DR (M33407) BATTERY FAIL TRANSFER REF NON - ROUTINE WO.1578459 AND ORIG BY V897794 L5 DR BATTERY (M33407) REPLACED AND TEST NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V920572 AND INSP BY V926996SDR JJBA20230320025Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS INOPERATIVE. DETERMINED FAULT TO BE BAD BATT 1 AND 4. REMOVED AND REPLACED BOTH BATTERIES. OPS CHECK SAT
BATTERY PACK #4 PN: ABS-2013-1A SN 61249 TSN 3920.06 CSN: 3300 TIME SINCE: 3198.54SDR CALA2023031500763Battery · failedB777-33-3-7019 DR L1 EMER LT BATTERY M33093 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.1483007 AND ORIG BY V898181 DR L1 M33093 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V898181 AND INSP BY V896992 IDT APPROVED BY HX0855SDR CALA2023031500762Battery · failedB777-33-3-7019 DR R2 M33098 EMER LT BATTERY DEEP CYCLE FAIL. TRANSFER REF NON - ROUTINE WO.1549655 AND ORIG BY V898181 DR R2 M33098 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HXSDR CALA2023031500761Battery · failedB777-33-3-7019 DR R4 EMER LT BATTERY M33408 TEST FAILED TRANSFER REF NON - ROUTINE WO.1563384 AND ORIG BY V898181 DR R4 EMER LT BATTERY M33408 REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V898181 AND INSP BY V896992 IDT APPROVED BY HX08554SDR CALA2023031500760Battery · failedB777-33-3-7019 DR R2 M33097 EMER LT BATTERY DEEP CYCLE FAIL TRANSFER REF NON - ROUTINE WO.1549666 AND ORIG BY V898181 DR R2 M33097 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HX0SDR CALA2023031500759Battery · failedB777-33-3-7019 DR L2 EMER LT BATTERY M33099 DEEP CYCLE FAIL TRANSFER REF NON - ROUTINE WO.1549668 AND ORIG BY V898181 DR L2 EMER LT BATTERY M33099 REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HX0SDR CALA2023031500758Battery · failedB777-33-3-7019 DR L2 M33096 EMER LT BATTERY DEEP CYCLE FAIL TRANSFER REF NON - ROUTINE WO.1549678 AND ORIG BY V898181 DR L2 M33096 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HX0SDR CALA2023031500757Charger · inoperativeB767-33-3-7000 - ZONE A SEAT 1-3 EEPL INOP TRANSFER REF HXWO 1594233 AND ORIGINATED BY EMP V920570 EMER LT PWR SUPPLY (M9043) REPLACED AND TESTED NORMAL AS PER AMM33-51-07 , EMER LT OP TEST CARRIED OUT AND FOUND NORMAL AS PER AMM33-51-00 WORK ACCOMPLISHED BY MSDR CALA2023031500756Battery · failedB777-33-3-7019 DR L3 EMER LT BATTERY M33400 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.1482995 AND ORIG BY V898181 DR L3 EMER LT BATTERY M33400 REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V898181 AND INSP BY V896992 IDT APPROVED BY HX0855SDR CALA2023031500741Battery · failedB777-33-3-7019 DR R3 EMER LT BATTERY M33401 CAPACITY LOW. TRANSFER REF NON - ROUTINE WO.1483013 AND ORIG BY V898181 DR R3 EMER LT BATTERY M33401 REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V898181 AND INSP BY V896992 IDT APPROVED BY HX085SDR CALA2023031500740Battery Pack · dischargedEMERGENCY POWER PACK, M1669, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK, BATTERY DISCHARGES IN LESS THAN 8 MINS. (REF. AAR NR 99962695). REMOVED AND INSTALLED NEW BATTERY PACK M1669 IAW B737 AMM 33-51-06-960-805, TEST OK (WORK ACCOMPLISHED BY V936248 & AAR QCA-SDR CALA2023031500739Battery Pack · failedEMERGENCY POWER PACK, M1674, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK, BATTERY DISCHARGES IN LESS THAN 12 MINS. (REF. AAR NR 99962693).V REMOVED AND REPLACED A NEW EMERGENCY POWER PACK IAW B737 AMM33-51-06-960-805 TEST PASS (WORK ACCOMPLISHED BY V942723 & AARSDR CALA2023031500738Battery Pack · dischargedEMERGENCY POWER PACK, M1672, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK, BATTERY DISCHARGES IN LESS THAN 7 MINS. (REF. AAR NR 99962696). REMOVED AND INSTALLED NEW BATTERY PACK (M1672) IAW B737 AMM33-51-06-960-805, TEST GOOD (WORK ACCOMPLISHED BY V936248 & AAR QSDR CALA2023031500737Battery Pack · failedEMERGENCY POWER PACK, M1675, FAILS EMERGENCY LIGHTING FUNCTIONAL CHECK, BATTERY DISCHARGES IN LESS THAN 10 MINS. (REF. AAR NR 99962694). REMOVED AND INSTALLED NEW BATTERY PACK M1675 IAW B737 AMM 33-51-06-960-805 TEST GOOD (WORK ACCOMPLISHED BY V936248 & AAR SDR GTIA2023031437042Epsu · no testREF DMI # 2857337-1 "EMER LIGHT BITE TEST FAILED"-R/R FWD 10WL EPSU IAW AMM 33-51-38. NO HELPSDR GTIA2023031437040Battery · fault messageDURING TASKCARD 335100-03-1 "CHECK BATTERY CAPACITY" EPSU BATTERY FWD L (10WL) + EMER R (12WL) FAULTED.-R+R THE BATTERY OF THE EPSU IAW AMM 33-51-38. PERFORMED BITE CHK IAW AMM 33-51-00. BITE CHK GOOD AT THIS TIME. PERFORMED CIDS POWER-UP TEST IAW AMM 23-73-00SDR CALA2023031300724Lamp · inoperativeRIGHT AFT OVERWING EXTERIOR EMERGENCY EXIT LIGHT INOP. RE-LAMPED OVERWING LIGHT REF MM 33-51-04. OPS CK OK. PARTS USED: 767,QTY :1SDR CALA2023031300723Battery Pack · no testEMERGENCY LIGHT BATTERY PACK AT DOOR 4R FAILED OPERATIONAL CHECK REF SIAEC N/R ELE0068 POWER SUPPLY BATTERY PACK AT DOOR 4R (M33401) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0068SDR CALA2023031300722Unknown · unknownEMER EXIT LTS ON ROW 32 - ROW 35 REPLACED BATTERY PACK AND POWER SUPPLY M2626 AND OPS CK REF AMM 33-51-06-960-805 TESTS GOOD ADD EMP:U117464 ACP IDT INSPECTION OF EMERGENCY PATH LIGHTING OPERATION. CKS OK.SDR CALA2023031300730Battery Pack · no testEMERGENCY LIGHT POWER SUPPLY BATTERY PACK AT DOOR 4L FAILED OPER ATIONAL TEST. REF SIAEC N/R ELE0070 POWER SUPPLY BATTERY PACK AT DOOR 4L (M33400) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0070SDR CALA2023031300729Battery Pack · no testEMERGENCY LIGHT POWER SUPPLY BATTERY PACK AT DOOR 4R FAILED OPER ATIONAL CHECK. REF SIAEC N/R ELE0069 POWER SUPPLY BATTERY PACK AT DOOR 4R (M33404) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0069SDR CALA2023031300728Battery Pack · no testEMERGENCY LIGHT BATTERY PAK AT DOOR 3L FAILED OPERATIONAL CHECK. REF SIAEC N/R ELE0067 POWER SUPPLY BATTERY PACK AT DOOR 3L (M33303) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0068SDR ASAA2023031042308Unknown · unknownTHE "EXIT SALIDA" SIGN OVER THE OVER WING EXIT FELL OFF. GROUNDED - YES. REINSTALLED OVERWING EXIT " EMERG" SIGN " OPS CHECKS OK.SDR ASAA2023031042305Unknown · unknownDOOR L2 EXIT SIGN FELL OFF. GROUNDED - YES. RESECURED EXIT SIGN COVER,OP CK NORMAL,NO DEFECTS NOTED. IAW B737-800 AMM 33-51-01.SDR 2023F00079Unknown · unknownABOUT 30 MINUTES AFTER TAKEOFF FROM GILA REGIONAL WITH A INTERFACILITY TRANSFER THE COCKPIT STARTED TO SMELL STRONGLY LIKE BURNING PLASTIC/RUBBER. NO SMOKE WAS PRESENT AND INSTRUMENTS AND WARNING LIGHT PANEL WAS NORMAL WITH NO INDICATIONS OF A PROBLEM BESIDES SDR GTIA2023031037027Battery · inoperativeEPSU - EMERGENCY POWER SUPPLY UNIT 11WL INOP - SDR REQUIRED.-SDR 2824488-2 GENERATED FOR EPSU AT POSITION 11WL. NO FURTHER ACTION REQUIRED. REFERENCE AEROMAN NR 2023-47432 ON W/O 2013 74 / 1.SDR CALA2023031000680Lamp · inoperativeB767-33-3-7000 - SEAT 44A EMER AISLE LIGHT INOP TRANSFER REF HXWO 1594230 AND ORIGINATED BY EMP V920570 SEAT 44A EMER AISLE LT LAMP REPLACED , LT ASSY RE-SECURED AND OP TEST CARRIED OUT AND FOUND NORMAL AS PER AMM33-51-05 WORK ACCOMPLISHED BY MECHANIC V920570 SDR CALA2023031000679Lamp · inoperativeB767-33-3-7000 SEAT 5A , 35AB , 27LK EMER LOWERED CEILING LT INOP TRANSFER REF HXWO 1490749 AND ORIGINATED BY EMP V920571 SEAT 5A , 35AB , 27LK EMER AISLE LT LAMP REPLACED & TESTED NORMAL AS PER AMM33-51-05 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V8SDR CALA2023031000678Power Supply · inoperativeB767-33-3-7000 - EMER LIGHT POWER SUPPLY (M1209) INOP TRANSFER REF HXWO 1497793 AND ORIGINATED BY EMP V920570 EMER LT PWR SUPPLY M1209 REPLACED & TESTED NORMAL AS PER AMM33-51-07 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V898561 IDT INSPECTED BY HX206SDR CALA2023031000677Power Supply · inoperativeB767-33-3-7000 - EMER LIGHT POWER SUPPLY (M737) INOP TRANSFER REF HXWO 1497707 AND ORIGINATED BY EMP V920570 EMER LT PWR SUPPLY M737 REPLACED AND TESTED NORMAL AS PER AMM33-51-07 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V898561 IDT INSPECTED BY HX206SDR CALA2023031000676Lamp · brokenB767-33-3-7000 - SEAT 32KL EMER AISLE LIGHT INOP TRANSFER REF HXWO 1497705 AND ORIGINATED BY EMP V920570 SEAT 32KL EMER AISLE LT LAMP REPLACED AND TESTED NORMAL AS PER AMM33-51-05 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V898561
Back to JASC 3300