Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023030900663None · missingEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - EMER PATHWAY LIGHTS AT SEATS 1ABC, 12ABC,20ABC & 23ABC INOP OR LENS MISSING. RELAMPED AND REPLACED LENS REF AMM TASK 33-51-11-960-801 OPS CHECKED GOOD. VERIFIED CORRECT LENS INSTALLATION AND OPS SDR CALA2023030900661Lamp · burnedB767-33-3-7000 - LH SLIDE LIGHT (L396) EMER LT INOP TRANSFER REF HXWO 1490734 AND ORIGINATED BY EMP V920571 LH SLIDE LT (L396) LAMP AND LENS ASSY REPLACED & TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V898561 IDT INSPECTSDR UIEA2023030900235Battery · noneFOUND EMERGENCY BATTERY (M5169) FUNCTION FAIL(<P>1. IAW AMM 33-51-04-902-001-001 REV107 REPLACED EMEREGENCY LIGHT POWER SUPPLY (M5169) BATTERY 2. IAW AMM 33-51-04-902-001-001 REV 107 PERFORMED POWER SUPPLY BATTERY INSTALLATION TEST AND THE RESULT WAS SATISFACTSDR CALA2023030900675Light · noneGALLEY NO.5 LEFT SIDE AFT FLOOR PROXIMITY LIGHT MALFUNCTION REF HAECO NON-ROUTINE NO.9450205 - ORIGINATED BY EMP V903217 SPEC NO .B787-33-3-0002. PERFORMED BY EMP V903194, IDT BY EMP V903217. REPLACED GALLEY NO.5 LH SIDE AFT FLOOR PROXIMITY LT AND FUNCTION TESSDR CALA2023030900674Sign · nonePASSENGER ENTRY DOOR 1L FWD LOWER EXIT SIGN LIGHT INOPERATION REF HAECO NON-ROUTINE NO.9450196 - ORIGINATED BY EMP V903194 SPE C NO.B787-33-3-0002. PERFORMED BY EMP V903194, IDT BY EMP V903217. REPLACED PASSENGER ENTRY DR 1L FWD LWR EXIT SIGN AND CONDITIONAL CSDR CALA2023030900673A/C Pack · nonePASSENGER SEAT 1D FWD EMERGENCY LIGHT MISSING REF HAECO NON-ROUT INE NO.9450180 - ORIGINATED BY EMP V903194 SPEC NO.B787-33-3-000 2. PERFORMED BY EMP V903194, IDT BY EMP V903217. INSTALLED SEAT 1D FWD EMERGENCY LT AND CONDITIONAL CHK ''NORMAL'' AND FUNCTION TESDR CALA2023030900672Light · nonePASSENGER SEAT 1D AFT EMERGENCY LIGHT MISSING REF HAECO NON-ROUT INE NO.9450181 - ORIGINATED BY EMP V903194 SPEC NO.B787-33-3-000 2. PERFORMED BY EMP V903194, IDT BY EMP V903217. INSTALLED SEAT 1D AFT EMERGENCY LT AND CONDITIONAL CHK ''NORMAL'' AND FUNCTION TESDR CALA2023030900660None · failedFOUND PAX SEAT 33DG-38DG EMERGENCY FLOOR PROXIMITY LIGHTS NOT IL LUMINATE WITH CMCF EXISTING FAULT MESSAGE: 33-11726 CLASS 26- DO OR 3 LH FWD SEAT REMOTE WELS CONTROL UNIT LAMP DRIVER POWER CIRC UIT IS FAILED. PERFORMED BY EMP V903179, PERFORMED T/S FOUND PAX SDR CALA2023030900659Lamp · burnedB767-33-3-7000 - LH O/WING ESCAPE LIGHT (L642) FWD SIDE INOP TRANSFER REF HXWO 1490756 AND ORIGINATED BY EMP V920571 LH O/WING ESCAPE LT (L642) LAMP REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V898561 IDT INSDR CALA2023030900652Lamp · burnedB767-33-3-7000 - DOOR 1L EMER LIGHT (L313) INOP TRANSFER REF HXWO 1497654 AND ORIGINATED BY EMP V920570 DOOR 1L EMER DOOR LT (L313) LAMP REPLACED AND TESTED NORMAL AS PER AMM33-51-03 WORK ACCOMPLISHED BY MECHANIC V920570 INSPECTED BY V898561SDR UIEA2023030700202Lamp · noneLEFT EXTERIOR LIGHT NEAR TO AFT FAIRING EMERGENCY LIGHT INOP(<P>RELAMPED EMERGENCY EXIT LIGHT NEAR TO AFT FAIRING IAW AMM 33-51-06. OPS CHECKS GOOD</P>)SDR SWAA2023030711829Sign · looseCABIN CEILING OVERWING EMERGENCY EXIT SIGN IS LOOSE<[01] RE-SECURED CABIN CEILING OVERWING EMERGENCY EXIT SIGN; PER AMM 33-51-01SDR CALA2023030600628Terminal · damagedOVERWING HATCH EXIT SIGN DIM AT L322 AND L297 REF HAECO NON-ROUT INE NO.:9407719,ORIGINATED BY EMP V905488,SPEC NO.:B767-33-3-700 0. PERFORMED BY EMP V905488,PERFORMED WIRING CHECK FOUND L297 LIGHT TERMINAL POOR CONDITION,REPLACED L297 TERMINAL AND INSTALLATIOSDR CALA2023030300598None · missingLFT LDG LT MISSING2 WIRES HANGING REPLACED LEFT LANDING LIGHT ASSY REF AMM 33-42-11 TESTS PASS PARTS USED: 31-3341-9-9001,QTY :1 ADD EMP:U102066 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1779896 SN OFF 1729 IPC REFERENCE # 33-42-05-01 LIGHT, RETRACTA OFF 31SDR CALA2023030300601None · damagedCEILING PANEL EMERGENCY LIGHT CONNECTOR DAMAGE AT FWD ZONE R/H NO.2,AFT ZONE R/H NO.4,AFT ZONE R/H NO.9,AFT ZONE L/H NO.9 CEILI NG PANEL,1A-10A,1L-10L CEILING PANEL REF HAECO NON-ROUTINE NO.: 9404868,ORIGINATED BY EMP V905488,EA 2500-12986 OP001. PERFORMED BY SDR QXEA2023030200032None · noneEXIT IDENTIFIER LIGHT ON FORWARD LAVATORY AFT WALL IS INOPERATIVE. REMOVED AND REPLACED #6 FUSE ON EMERGENCY LIGHT POWER UNIT #2 PER DIEHL CMM 33-50-01.SDR UIEA2023022300176Power Supply · noneM5169 EMER LT BATTERY PACK CAPACITY TEST FAILED(<P>M5169 EMER LT POWER SUPPLY REPLACED AND INSTALLATION TEST NORMAL IAW AMM 33-51-04 REV 106, 15 NOV 2022</P>)SDR CALA2023030100589Battery · failedB777-33-3-7019 DR R2 EMER LIGHT BATTERY M33098 CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1462757 AND ORIGINATOR V898181. DR R2 EMER LIGHT BATTERY M33098 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK SDR CALA2023030100587Battery · failedB777-33-3-7019 DR L2 EMER BATTERY M33096 CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1462768 AND ORIGINATOR V898181. DR L2 EMER LIGHT BATTERY M33096 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK ACCOMPSDR CALA2023030100586Battery · failedB777-33-3-7019 AFT CREW REST L/H EMER LIGHT BATTERY M33143 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462794 AND ORIGINATOR V898181. AFT CREW REST EMER LIGHT BATTERY M33143 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPSDR CALA2023030100584Battery · failedB777-33-3-7019 DR L4 EMER LIGHT BATTERY M33405 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462800 AND ORIGINATOR V934240. DR L4 EMER LIGHT BATTERY M33405 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK ACCOMPLSDR CALA2023030100583Battery · failedB777-33-3-7019 DR R3 EMER LIGHT BATTERY M33305 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462812 AND ORIGINATOR V898181. DR R3 EMER LIGHT BATTERY M33305 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V89695SDR CALA2023030100582Charger · failedB777-33-3-7019 DR R4 EMER LT CHARGER M33401 TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1462818 AND ORIGINATOR V898181 DR R4 EMER LT BATTERY CHARGER M33401 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958 SDR CALA2023030100581Battery · failedB777-33-3-7019 DR R4 EMER LIGHT BATTERY M33401 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462826 AND ORIGINATOR V898181. DR R4 EMER LIGHT BATTERY M33401 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED WORK ACCOMPLISDR CALA2023030100572Battery Pack · inoperativeEMERGENCY LIGHTS AT BIN 30 AND 32ABC FAIL TO COME ON. REF TO PEMCO NR 13359.0119 REMOVED AND REPLACED EMERGENCY LIGHTS PACK AT M1670 IAW B737 AMM 33-51-06-960-805, OPS CHECK GOOD FOR EMERGENCY EXIT LIGHTS AT OVERHEAD BINS 30 ABC AND 32 ABC. WORK PERFORMED BY VSDR UIEA2023030100195None · noneEXIT LIGHT ASSY AT L4 BROKEN.(<P>REMOVED AND REPLACED EXIT LIGHT ASSY AT L4 PER B767 AMM 33-51-01</P>)SDR CALA2023022700556Battery Pack · failedOVERHEAD ATTENDANT REST (OHAR) EMERGENCY LIGHT DO NOT COME ON DU RING OPERATIONAL CHECK (T/S) B777-33-3-7028 REMOVED AND REPLACED EMERGENCY POWER SUPPLY AT OHAR OPS CHECK GO OD ALL IAW B777 AMM TASK 33-51-06-960-803 COMPLETED ON ST NON RO UTINE 97224SDR WX0A2023022731739Epsu · noneRIGHT OVERWING EMERGENCY LIGHTS AND EXIT SIGN INOP ON BATTERY POWER. / PERFORMED EPSU BITE TEST~FAILS 12WL AT RT EXIT. REMOVED AND REPLACED 12WL EPSU AND TESTS OK (BITE TEST OK AND LIGHTS ILLUMINATE WITH POWER OFF). REF AMM 33-51-38-000-001-A AND 33-51-38-400-SDR CALA2023022200517Battery · noneB777-33-3-7019, SEAT 22A TO SEAT 37A CEILING EMER LT BATTERY , PACK CAPACITY CHECK FAIL (M33400, DOOR 3L). TRANSFER NR WO.1482076 AND ORIGINATED BY V907894.SDR CALA2023022200516Battery · noneB777-33-3-7019, DOOR 3L & 3R MASTER CALL LT/ EXIT SIGN EMER LT. BATTERY PACK CAPACITY CHECK FAIL (M33406, DOOR 3L). TRANSFER NR WO.1482089 AND ORIGINATED BY V907894.SDR CALA2023022200514Battery · noneB777-33-3-7019, SEAT 46L TO SEAT 51L CEILING EMER LT BATTERY. PACK CAPACITY CHECK FAILED (M33409, DOOR 4R). TRANSFER NR WO.1482100 AND ORIGINATED BY V907894.SDR CALA2023022200506Battery · failedB777-33-3-7019, SEAT 10L TO SEAT 20L CEILING EMER LT BATTERY PACK CAPACITY CHECK FAIL(M33098, DOOR 2R). TRANSFER NR WO.1482050 AND ORIGINATED BY V907894.SDR CALA2023022200505Charger · failedB777-33-3-7019, DOOR 3L & 3R MASTER CALL LT/ EXIT SIGN EMER LT BATTERY PACK CAPACITY CHECK FAIL (M33406, DOOR 3L). TRANSFER NR WO.1482089 AND ORIGINATED BY V907894.SDR WX0A2023022031735None · noneLEFT/RIGHT OVERWING EMERGENCY EXIT LIGHT HAS 1 LAMP EACH INOP (FAR AFT) / REMOVED AND REPLACED 1EA LAMP L/H, R/H OVERWING AFT EMERGENCY EXIT LIGHT IAW AMM 33-51-15-000-001-A. AND 33-51-15-400-001-A. PERFORMED OPS CHECK. OPS CHECK GOOD."SDR CALA2023021300409Battery Pack · failedRH AFT OVERWING EMERGENCY LIGHT FAILED EMERGENCY LIGHTING SYSTEM -FUNCTIONAL CHECK (REF AAR NR 99957255)SDR IPXA2023021290912Battery · no testINSPECTION TYPE:C14FOUND EMERGENCY LIGHT POWER SUPPLY DEEP CYCLING TEST FAIL.1.I.A.W AMM 33-51-07-022-001 AND 33-51-07-422-012 REV.138.01 REPLACED EMERGENCY LIGHT POWER SUPPLY AT COCKPIT. 2.I.A.W AMM 33-51-07-422-012 REV.138.01 PERFORMED BATTERY PACK TEST,RESUSDR UIEA2023021300111Lamp · noneEMERGENCY LIGHT BY L 1 DOOR INOP.(<P>RELAMPED OPS CHECK NORMAL IAW AMM 33-51-00</P>)SDR GTIA2023020136965Epsu · no testEPSU- EMERGENCY SUPPLY UNIT 13WL FAILED TEST, SDR REQUIRED.-SDR 2907402-1 GENERATED FOR EPSU AT POSITION 13WL. NO FURTHER ACTION REQUIRED. REFERENCE AEROMAN NON ROUTINE 2022-648758 ON W/O 2022-481/1SDR WX0A2023021031728Epsu · noneEPSU (12WL) AND EPSU (13WL) FAIL BITE CHECK REF AMM 33-51-00-710-001 / REMOVED AND REPLACED EPSU (12WL) AND (13WL) REF AMM 33-51-38-000-001-A AND AMM 33-51-38-400-001-A OPS CHECK GOOD,"SDR WX0A2023020831727Epsu · noneDURING ESPU BAT CAP TEST, EPSU BAT (12WL) FAIL / REMOVED AND REPLACED ESPU BAT (12WL) IAW AMM 33-51-38-400-002-A OPS CHECK GOOD"SDR WX0A2023020831726Epsu · noneDURING WEEKLY CHECK, FOUND EMERGENCY BATTERY FAULTING AT EPSU [11WL] EMER L / R/R EPSU BATTERY 11WL IAW AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A"SDR CALA2023020100310None · noneWHILE T/S R1 DOOR EMERGENCY LIGHT, L1 DOOR EMERGENCY LIGHT BECAME INOP. R/R CORRESPONDING BATTERY CHARGER POWER SUPPLY IRW WITH 33-51-06. ALL OPS CHK NORMAL. PARTS USED: 29-3351-3-0031,QTY :1SDR CALA2023020100308None · noneFWD EMERGENCY BATTERY FAILED CAPACITY TEST. R+R FWD EMERGENCY LIGHT BATTERY REF 33-51-38. OPS CHECK GOOD.SDR CALA2023020100307Light · failedRH OVERWING EMERGENCY BATTERY FAILED CAPACITY TEST. R+R RH OVERWING EMERGENCY LIGHT REF 33-51-38. OPS CHECK GOOD. SUPPOSED TO READ EMERGENCY LIGHT BATTERY.SDR CALA2023020100306None · failedFWD EMERGENCY LIGHTS BATTERY FAILED CAPACITY TEST. R+R FWD EMERGENCY LIGHT BATTERY REF 33-51-38. OPS TEST GOOD. PARTS USED: 18-3351-3-0001,QTY :1SDR CALA2023020100305Battery · failedLH OVER WING EMERGENCY LIGHTS BATTERY FAILED CAPACITY TEST. R+R RH OVERWING EMERGENCY LIGHT BATTERY REF 33-51-38. OPS TEST GOOD.SDR CALA2023020100303Battery · noneCABIN EMERGENCY LIGHTS OPERATIONAL CHECK: {A3NB-33-3-6012} - TEST FAULTS EPSU BATTERY AFT L RPLD EPSU 13WL AND OPS CK CK NORMAL REF AMM 33-51-38-000-001-A AND AMM 33-51-00-710-001-ASDR CALA2023020100297None · failedCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - LEFT PASSENGER CABIN EMERGENCY LIGHTS BATTERY FAILED CAPACITY TEST. REMOVED AND REPLACED LEFT EMERGENCY LIGHT BATTERY IAW AMM 33-51-38SDR CALA2023020900374Power Supply · inoperativeB767-33-3-7000 - EMER PWR SUPPLY M739 INOP TRANSFER REF. NON-ROUTINE WO.1376535 & ORIGINATED BY EMP V920570 EMER PWR SUPPLY M739 REPLACED AND TESTED NORMAL PER AMM 33-51-07 WORK ACCOMPLISHED BY MECHANIC V920571 INSPECTED BY V897802SDR DALA2022120607846Light · none3L SLIDE LIGHT INOP. CORRECTIVE ACTION: OPS CKD SLIDE LIGHT. OPS NML. (9816114)
Back to JASC 3300