JASC 3320

Service difficulty reports · 2,972

Reports filed under 3320 · Passenger Compartment Lighting, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3320'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA201703209014Ballast · inoperativeAIRCRAFT WAS NOT GROUNDED. RIGHT OVERWING EMERGENCY EXIT LIGHT ON UPPER AFT SIDE WALL IS INOPERATIVE. REMOVED AND REPLACED 15F EXIT DOOR SIDEWALL LIGHT BALLAST IAW AMM 33-21-00. OPERATIONAL CHECK GOOD.Mar 13, 2017 · N946AN · Boeing 737823SDR SWAA2017030112207Ballast · odorFLIGHT ATTENDANTS REPORTED A FAINT BURNING ODOR AFT OF ROW 23. R & R AFT ENTRY LIGHT BALLAST IAW MMM.Feb 28, 2017 · N385SW · Boeing 7373H4SDR HNAA2017022700067Holder · burnedSEAT 13AC OVERHEAD BIN LIGHT SMOKE. CABIN OVERHEAD LIGHTS AND CIRCUIT BREAKERS S1,S2 AND R2 DEACTIVATED.COLLARD CIRCUIT BREAKERS. LOWERED BINS AT 12 AND 11AC. REMOVED AND REPLACED BALLAST AND LAMP HOLDER. SPLICED WIRES IAW MM 20-45-07. SECURED BINS, RESET Feb 27, 2017 · N337EN · Dhav DHC8311SDR DXTA2017022206374Light · meltedDURING DESCENT, THERE WAS SMOKE COMING FROM THE LEFT CIRCUIT PANEL. AN EMERGENCY DESCENT WAS PERFORMED AND ELECTRICAL FIRE OR SMOKE CHECKLIST G1 WAS INITIATED AND COMPLETED. INSPECTED THE AIRCRAFT FOR SOURCE OF SMOKE AND FOUND AISLE LIGHTS ON LEFT SIDE MELTEFeb 22, 2017 · N686QS · Cessna 560XLSDR REXA2017022000256Sign · false activationSEAT BELT CHIMED ON ITS OWN WITHOUT MOVING THE SEAT BELT SIGN SWITCH. THE FA IS REPORTED A SLIGHT ODOR OF HOT ELECTRICAL. UNABLE TO DUPLICATE. INSPECTED ALL CABIN PSU'S & LIGHTING, NO FAULTS NOTED. OPS TESTED GOOD IAW AMM 33-24-01 & 25-28-01 & 23-31-17.Feb 20, 2017 · N309PQ · Cndair CL6002D24SDR A6WA2017021544789Ballast · failedBURNING PLASTIC ODOR IN CABIN. BECAME STRONGER IN THE BACK OF THE AIRCRAFT. SMOKE ALARM DID NOT SOUND, NO ELECTRICAL SYSTEMS, LIGHTS, ALARMS APPEARED TO BE ERRATIC. SHUT DOWN ENTIRE AIRCRAFT PENDING MX CHECK. R & R BOTH LIGHT BALLASTS AT ROW 13A/C IAW AMM 13-Feb 10, 2017 · N410AW · Cndair CL6002B19SDR WX0A073228Bulb · failedELECTRICAL BURNING ODOR COMING FROM OVERHEAD BIN AREA OF SEATS 35 &36 DEF. TROUBLESHOOT USING CABIN ODOR, SMOKE WORK CARD 21-059-002. FOUND BAD BULB AT SEATS 35 &36 DEF. REMOVED BULB.Feb 10, 2017 · N410NV · Doug DC983SDR DALA2017020701008Fuse · blownF/A ON AFT JUMPSEAT REPORTED HEARING 3 POPS AND SEEING ONE BRIGHT FLASH ON FINAL APPROACH, AFTER GEAR EXTENSION BUT BEFORE LANDING ALSO REPORTED AN ELECTRICAL ODOR THAT DISSIPATED AFTER LANDING. PERFORMED PNEUMATIC SYSTEM DUCT BURNOUT, NO DEFECTS NOTED. ENGINFeb 6, 2017 · N981DL · Doug MD88SDR CALA2017020300244Socket · odorVERY STRONG ELECTRICAL HOT BURNING ODOR IN FWD GALLEY. REPLACED FAULTY LIGHT SOCKET IAW WDM 33-26-21. REPLACED THE LAMP OPS CHECKED NORMAL.Feb 3, 2017 · N39423 · Boeing 737924ERSDR HNAA2017020100033Lens · detachedRIGHT SIDEWALL LIGHT LENS FELL DOWN AFTER TAKE OFF AT ROWS 4-7. REMOVED AND REPLACED SIDEWALL LIGHT LENS AS REQUIRED. OKAY FOR SERVICE.Feb 1, 2017 · N335EN · Dhav DHC8311SDR SWIA201743020Ballast · odorAFTER TAKEOFF, STRONG BURNING ODOR AND SMOKE NOTED IN CABIN, DECLARED EMERGENCY AND RETURNED TO DEPARTURE. REMOVED AND REPLACED THE BALLAST AT ROW 7 C&D. ALL CHECKED GOOD.Feb 1, 2017 · N820SK · Cndair CL6002D24SDR ASOA201701311124Light · burnedSEVERAL PASSENGERS SAW SMOKE & FA REPORTED SMELL OF ELECTRICAL SMOKE FROM SEAT 6 A/B. REMOVED AND REPLACED THE BURNT SIDEWALL LIGHT ON SEAT 6 A/B IAW AMM 33-21-07-000-801. OPS CHECKED GOOD.Jan 31, 2017 · N132EV · Cndair CL6002D24SDR CALA2017013000198Ballast · faultyELECTRICAL SMELL AFT AIRCRAFT ISOLATED SMELL COMING FROM AREA AT ROW 34 RIGHT OVERHEAD. REPLACED LIGHT BALLAST DIRECTLY ABOVE THAT ROW. INSPECTED CARGO PITS, PSU PANELS. RAN PACKS NO BURNING SMELL NOTICED. AS PER AMM 05-51-58 CREW FILLED OUT FORM 46.6020. ALSOJan 30, 2017 · N13110 · Boeing 757224SDR DALA2017012300583Terminal · looseDURING CRUISE, THE FLIGHT ATTENDANTS DETECTED AN ELECTRICAL ODOR MOST NOTICEABLE AT THE AFT FLIGHT ATTENDANT JUMP SEAT POSITION. THE CREW PERFORMED QRH SMOKE/ODOR PROCEDURE AND DIVERTED TO TPA. MAINTENANCE TROUBLESHOT PER WORK CARD 2120-2367 AND FOUND AFT LEFTJan 21, 2017 · N988DL · Doug MD88SDR PNSA2017012101Receptacle · shortedFLAME & SMOKE FROM CABIN LIGHTING ABOVE 3A SHORTED WINDOW LIGHT RECEPTACLE.Jan 21, 2017 · N685PA · Saab 340BSDR U9FR20170124001Light · arcedDURING TAXI THE ODOR OF BURNED WIRING WAS NOTED BY A CREW MEMBER. DURING FURTHER INVESTIGATION, A WHISP OF SMOKE WAS NOTED IN THE CABIN AREA. TAXI OPERATION WAS ABORTED AT THIS TIME. AIRCRAFT WAS BROUGHT TO MAINTENANCE WHERE IT WAS DISCOVERED THAT THE "+" TERMJan 20, 2017 · N519A · Beech C90SDR CALA2017011300077Light · smokeSMOKE CAME OUT OF BOTH EYEBALL LIGHTS ABOVE R1 DOOR. TURNED OFF BOTH LIGHTS, PERFORMED INSPECTION IAW MM TASK 05-51-58-800-801C3. REPLACED THE LAMPS AND LIGHT ASSY.Jan 13, 2017 · N229UA · Boeing 777222SDR YENA201701120029Lamp · inoperativeFLOOR LEVEL LIGHTS AT 19C, 11D, 3C INOPERATIVE. REPLACED THE LAMPS. OK FOR SERVICE.Jan 12, 2017 · N588JB · Airbus A320232SDR ASOA201701125006Light · arcedCREW REPORTED VISIBLE SMOKE AND FUMES FROM OVERHEAD PANEL ABOVE SEAT 6D. CONTRACT MX FOUND LOOSE SIDEWALL LIGHT ARCING CAUSING PLASTIC TERMINAL TO BURN AND CAUSE SMOKE. DISCONNECTED AND PLACED ON MEL 33-20-00-2. REMOVED AND REPLACED SIDEWALL LIGHT ASSY WITH OPJan 12, 2017 · N12163 · Emb EMB145XRSDR IPXA2017010612451Lamp · inoperativeLAVATORY MIRROR LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM33-51-21-401.Jan 6, 2017 · N154UP · Airbus A300F4622RSDR AALA20170109026Ballast · burnedDURING MANEUVERING FOR LANDING, THE ENTIRE CABIN AND COCKPIT EXPERIENCED AN UNUSUAL ODOR LASTING 3 OR 4 MINUTES. NO SMOKE OR HAZE PRESENT. AIRCRAFT WAS GROUNDED. REMOVED AND REPLACED A BURNED CEILING LIGHT BALLAST AT ROW 8 IAW AMM 33-21-03. OPS CHECKED GOOD.Jan 5, 2017 · N513AA · Doug DC982SDR YENA201701050022Lamp · failedDISCOVERED 23F CABIN SIDEWALL LIGHT BURNED OUT. THERE WAS AN ASSOCIATED BURNED ELECTRICAL ODOR IN GALLEY; REPLACED THE LAMP. OPS CHECK PASSED. ACCOMPLISHED TSM 24-00-00-810-823. NO OTHER ELECTRICAL ODORS NOTED IN CABIN OR GALLEY AREA. NO BREAKERS TRIPPED. INJan 5, 2017 · N793JB · Airbus A320232SDR HALA2017010100569Socket · defectiveATB, ELEC SHORT LAV 'C' BURNING SMELL & CHARRING **VANITY LIGHT ** (LAVATORY VANITY LIGHTS ). REMOVED AND REPLACED LAMP HOLDER/SOCKET PER IPC 33-26-00-65C AND WDM 33-26-11 AND INSTALLED 2[EA] NEW BULBS OPERATIONAL CHECK OK CLEARED MIC SHEET AND REMOVED PLACARJan 2, 2017 · N590HA · Boeing 7673CBSDR IPXA2017010212309Light · inoperativeLAVATORY MIRROR LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM33-51-21-401.Dec 31, 2016 · N164UP · Airbus A300F4622RSDR ASOA201612063083Light · smokeCREW REPORTED SMOKE COMING FROM OVERHEAD GALLEY LIGHTS. MAINTENANCE INSPECTED AND REPLACED THE GALLEY LIGHT ASSEMBLY. OPS CHECKED GOOD.Dec 6, 2016 · N12921 · Emb EMB145LRSDR IPXA2016120111237Light · inoperativeLAVATORY MIRROR LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-21-401.Dec 1, 2016 · N145UP · Airbus A300F4622RSDR ASOA201611304110Ballast · inoperativeCREW REPORTED SMOKE IN THE CABIN. THE AIRCRAFT DIVERTED AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED ENGINE, APU, AND PACK CHECKS WITH NO DEFECTS NOTED, CABIN INSPECTION REVEALED INOPERATIVE SIDEWALL LIGHTS AT SEATS 5A & 20A. MAINTENANCE DISCONNECTED THENov 30, 2016 · N11176 · Emb EMB145XRSDR ASOA201611304111Ballast · inoperativeCREW REPORTED SMOKE IN THE CABIN. THE AIRCRAFT DIVERTED AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED ENGINE, APU, AND PACK CHECKS WITH NO DEFECTS NOTED, CABIN INSPECTION REVEALED INOPERATIVE SIDEWALL LIGHTS AT SEATS 5A & 20A. MAINTENANCE DISCONNECTEDNov 30, 2016 · N11176 · Emb EMB145XRSDR ASOA20161130111Ballast · inoperativeCREW REPORTED SMOKE IN THE CABIN. THE AIRCRAFT DIVERTED AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED ENGINE, APU, AND PACK CHECKS WITH NO DEFECTS NOTED, CABIN INSPECTION REVEALED INOPERATIVE SIDEWALL LIGHTS AT SEATS 5A & 20A. MAINTENANCE DISCONNECTED Nov 30, 2016 · N11176 · Emb EMB145XRSDR ASOA20161130110Ballast · failedCREW REPORTED SMOKE IN THE CABIN. THE AIRCRAFT DIVERTED AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED ENGINE, APU, AND PACK CHECKS WITH NO DEFECTS NOTED, CABIN INSPECTION REVEALED INOPERATIVE SIDEWALL LIGHTS AT SEATS 5A & 20A. MAINTENANCE DISCONNECTED THENov 30, 2016 · N11176 · Emb EMB145XRSDR SWAA2016110809487Bulb · overheatedELECTRICAL BURNING ODOR FOR 15 TO 20 SECONDS. R & R THE CEILING LIGHT FLUORESCENT BULB IAW AMM.Nov 7, 2016 · N653SW · Boeing 7373H4SDR DALA2016110708302Relay · burnedRUBBER SMELL ON TAKEOFF WITH BURNING ODOR. DISSIPATED IN 2-3 MINUTES. UPPER SIDEWALL LIGHTS FLICKERED ON AND OFF (INTERMITTENT USE). COFFEE MAKERS ON AND OFF ALSO. AS PER QRH TURNED GALLEY POWER OFF AISLE LIGHT ON AND SIDEWALL LIGHTS OFF. UPPER SIDEWALL LNov 6, 2016 · N965DL · Doug MD88SDR ASOA201610270625Control Module · odorF/A REPORTS A BURNING SMELL COMING FROM BEHIND SPEAKER IN GALLEY. MX REMOVED AND REPLACED GALLEY LIGHTING CONTROL MODULE POWERED A/C WITH NO BURNING SMELL FOUND REF 145 33-29-01. A/C WAS APPROVED FOR RETURN TO SERVICE.Oct 27, 2016 · N12924 · Emb EMB145LRSDR MASA2016102312474Ballast · inoperativeROW 1 AND 8 CEILING AND SIDEWALL BALLAST INOPERATIVE.Oct 24, 2016 · N511MJ · Cndair CL6002C10SDR CALA2016102100801Light · defectiveSMOKE + POPPING SOUNDS REPORTED BY FLIGHT ATTENDANTS, ROWS 21-27 MID CABIN, AT 36,000 CRUISE. ELECTRIC SMELL LESS THAN 5 MINUTES. REPLACED BIN CEILING LIGHT ASSEMBLY, M1842, AT ROW 27ABC REF MM TASK 33-22-00-960-805. OPERATION CHECK OF LIGHT OK. NO ELECTRIOct 21, 2016 · N27205 · Boeing 737824SDR ASOA201610180605Ballast · shortedPILOT REPORTED THE LAVATORY CIRCUIT BREAKER TRIPPED FOLLOWED BY ELECTRICAL ODOR. REMOVED AND REPLACED THE LAVATORY LIGHT BALLAST AND OPS CHECKED GOOD. APPROVED FOR RETURN TO SERVICE.Oct 18, 2016 · N13978 · Emb EMB145LRSDR SIMA20161017001Light · odorGALLEY LIGHTS BURNING ODOR REPORTED BY FLIGHT ATTENDANTS. OPC GALLEY LIGHTS IAW AMM 33-26-00. OPERATED GALLEY LIGHTS FOR SEVERAL HOURS WITH OUT HAVING ODORS IN GALLEY FROM LIGHTS. OPS CHECKED GOOD.Oct 17, 2016 · N523AE · Cndair CL6002C10SDR SWAA2016101808906Ballast · overheatedFLIGHT ATTENDANT REPORTED BURNED RUBBER SMELL IN GALLEY AREA. SEEMED TO CORRELATE WITH FORWARD LAV FLUSH. R&R BALLAST PER MM.Oct 14, 2016 · N437WN · Boeing 7377H4SDR QXEA2016101300651Bulb · failedAFT F/A STATION LIGHT BULB POPPED. MINOR SMOKE EMITTED. REMOVED BROKEN BULB & DEFRIS FROM AFT GALLEY WORK LIGHT. PERFORMED GVI OF AFT GALLEY WORK LIGHT W/ NO DEFECTS NOTED. REPLACED THE BULB. BULB TESTED GOOD, NO FURTHER DEFECTS NOTED. RETURNED TO SERVICEOct 13, 2016 · N415QX · Bombdr DHC8402SDR A6WA201644420Power Unit · failedREQUEST INSPECTION FOR POSSIBLE ELECTRIC SMELL AT ROW 11 AND 12. REMOVED AND REPLACED POWER UNIT/DIMMER ABOVE ROWS 12DF. OPS CHECK GOOD IAW AMM 33-21-00.Oct 10, 2016 · N417AW · Cndair CL6002B19SDR SWAA2016101108570Ballast · faultyELECTRICAL SMELL NEAR AFT GALLEY. R&R BALLAST PER AMM.Oct 8, 2016 · N7725A · Boeing 73776NSDR 6EAY20161005001Lamp · failedON REMOVING THE LED LIGHT TUBE ASSEMBLY IN POSITION RT UPPER 4, IT WAS FOUND THAT THE LED LIGHT TUBE HAD BURNED OUT, CAUSING THE LIGHT LENS TO MELT AND FUSE TO THE LED LIGHT TUBE. ALSO RT UPPER 1 LED LIGHT TUBE ASSEMBLY HAD SIGNS OF A SIMILAR FAILURE.Oct 2, 2016 · Cndair CL6002B16SDR YENA20160926874Ballast · failedFLT 162 SMF-JFK, DIVERTED TO SLC. FLIGHT CREW REPORTED UNKNOWN ODOR AFT CABIN. DESCRIBED AS PROPANE OR SULFUR. DID NOT DISSIPATE CLEARED AFTER LANDING W/ PACKS OFF. ACCOMPLISHED TSM TASK 05-50-00 TO IDENTIFY OF CAUSE OF CABIN ODOR. ISOLATED CAUSE OF THE OSep 26, 2016 · N775JB · Airbus A320232SDR CALA2016092200672Light · malfunctionedOVERHEAD LIGHTS IN CENTER SECTION OF CABIN FLICKERING. NEAR EMERGENCY EXIT. LED SEGMENTS OVER SEATS 15ABC AND 14 DEF ARE INOPERATIVE. THE REST OF EACH LIGHT BAR LED SEGMENTS ARE ON. OPS SEVERAL TIMES CABIN LIGHTS COULD NOT DUPLICATE PROBLEM.Sep 21, 2016 · N28457 · Boeing 737924ERSDR AALA201609209001Ballast · defectiveAIRCRAFT WAS GROUNDED: F/A REPORT A STRONG JET FUEL ODOR IN MID CABIN MOVING AFT THEN MOVING FORWARD. MAINTENANCE TROUBLESHOT CABIN ODOR IAW J/C 26L00021001 AND COULD NOT DUPLICATE FUEL ODOR IN CABIN DURING BLEED SYS ISOLATION DID DETECT AN ELECTRICAL ODOR INSep 16, 2016 · N509AY · Airbus A321231SDR A6WA201644332Ballast · inoperativeFLIGHT 4041.ODOR IN CABIN SIMILAR TO ELECTRICAL OVERHEAT. STRONGEST MID CABIN. LT SIDE ROW 9 SIDE WALL LIGHT INOPERATIVE. INSPECTED AND FOUND LIGHT BALLAST INOPERATIVE AT SEAT 1CA. REMOVED AND REPLACED BALLAST AND SIDEWALL LIGHT BULB OPS CHECK OK. NO ODORSep 14, 2016 · N448AW · Cndair CL6002B19SDR ASOA20160913008ADimmer · burnedPILOT REPORTED BURNING ODOR TOWARD LAV AREA. MX REMOVED AND REPLACED THE POWER UNIT DIMMER ON ROW 11AB, 12AB, AND 14AB IAW AMM 33-21-04. OPS CHECKED GOOD. ACFT OK FOR SERVICE.Sep 13, 2016 · N882AS · Cndair CL6002B19SDR FDEA201609103187Light · intermittentBOTTOM ONE THIRD OF OVERHEAD PANEL LIGHTS WERE INTERMITTENT. REF WDM 23-71-11, 33-13-31 & CMM 23-70-43 CVR MPN 980-6116-002 DOES NOT CONTAIN CONTACTS FOR INTEGRAL PANEL LIGHTING.Sep 10, 2016 · N963FD · Boeing 75728ASDR SIMA20160909005Dimmer · odorBURNING PLASTIC ODOR IN COCKPIT AND COCKPIT ENTRY WAY. REMOVED AND REPLACED THE FWD LT SIDEWALL AND CEILING LIGHTS POWER UNIT & DIMMER IAW AMM 33-21-09 AND AMM 33-21-03. OPS CHECKED GOOD. RAN ENGINE AND PACKS COULD NOT DUPLICATE ODOR.Sep 9, 2016 · N506AE · Cndair CL6002C10SDR AALA201609079003Bulb · odorAIRCRAFT WAS NOT GROUNDED: PASSENGER READING LIGHT ABOVE SEAT ROW 6DEF VERY HOT CAUSED BURING ODOR IN BIN ABOVE SEAT ROW 6DEF WITH LIGHT OFF ODOR DECREASED. MAINTENANCE RELAMPED ALL BULBS AT SEAT ROW 6DEF READING LIGHTS IAW AMM 33-25-00. DROPPED PANEL AND INSep 6, 2016 · N604AW · Airbus A320232
Back to JASC 3320