SDR HNAA2017092900337Socket · burnedOVERHEAD LIGHT AT SEAT 2DF HAD A BURNED ODOR. PERFORMED AN INSPECTION TO THE OVERHEAD LIGHT. FOUND THE LIGHT SOCKET BURNED.Sep 26, 2017 · N343EN · Dhav DHC8311SDR AALA201709119032Cover · crackedTHE AIRCRAFT WAS NOT GROUNDED. AFT GALLEY- WORK LIGHT HEAT DAMAGE WITH BURNING SMELL- RIGHT SIDE GALLEY. FOUND COVER CRACKED AND AGAINST LAMP. REMOVED AND REPLACED WORK LIGHT COVER. LIGHT CHECKS NORMAL REF AMM 33-26-02.Sep 7, 2017 · N960AN · Boeing 737823SDR CALA2017090403043Bezel · burnedFLT ATTENDANT REPORTED A BRIEF MOMENT OF SMOKE, BOTH VISUALLY AND BY SMELL FROM FORWARD GALLEY, SPOKE WITH FLIGHT CREW, FO COULD DETECT THE SMOKE AND FLT ATTENDANT ALSO AROUND FIRST CLASS GALLEY, WHITE SMOKE WAS NOTED AT TOP END OF GALLEY FOR A SHORT TIME. Sep 4, 2017 · N36280 · Boeing 737824SDR CALA2017090102956Light · odorROW 23HJK ELECTRICAL ODOR. CEILING LIGHTS AT 25 HJK INOPERATIVE. REMOVED AND REPLACED CEILING LIGHT. OPS CHECKED GOOD.Sep 1, 2017 · N222UA · Boeing 777222SDR A6WA2017082545225Ballast · burnedELECTRICAL SMOKE ODOR OVER ROWS 2, 3, AND 4. FOUND CEILING LIGHT BALLAST AT SEAT 4CA BURNED. REMOVED AND REPLACED CEILING BALLAST. OPS CHECKED GOOD IAW AMM 33-21-04.Aug 24, 2017 · N437AW · Cndair CL6002B19SDR REXA2017082000899Ballast · faultyBURNING SMELL AT THE BACK OF THE CABIN AT LAST ROW SEAT. FOUND POWER UNIT/DIMMER (BALLAST) BURNING REMOVED ANND REPLACED BALLAST IAW 33-21-10 OPS CHECK GOOD.Aug 20, 2017 · N8721B · Cndair CL6002B19SDR WX0A2017082300286Ballast · smokeOVERHEAD LIGHT FLICKERED & SMOKE CAME FROM IT. R & R THE BALLAST AND ASSOCIATED HARNESS FOR UPPER SIDEWALL LIGHTS.Aug 19, 2017 · N883GA · Doug DC983SDR DALA2017073005784Transformer · damagedFUME EVENT AT CRUISE. SMELLED ELECTRICAL BUT COULD NOT ISOLATE. WENT AWAY AFTER 5 MIN APPROX. MAYBE ASSOCIATED WITH ENG ANTI ICE. ON DESCENT RETURNED COMPLIED WITH QRH. SEEMED TO DISSIPATE AFTER RIGHT PACK/ AND RECIRC FAN/ GND SVC BUS C/B'S PULLED. ON GND FUMEJul 29, 2017 · N934DL · Doug MD88SDR IPXA2017072119585Lamp · inoperativeLAVATORY AVX MIRROR LIGHTS INOPERATIVE. REPLACED THE LAMPS IAWAMM 33-41-21-0402. OPS CHECKED GOODJul 20, 2017 · N125UP · Airbus A300F4622RSDR CALA2017071702263Light · failedLIGHT IN G LAVATORY PRODUCES AN ACRID ODOR AND BURNS AROUND FLOURESCENT LIGHT CONNECTION. REMOVED AND REPLACED THE LIGHT ASSY IAW CMM 25-48-22. OPS CHECKED GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.Jul 17, 2017 · N76064 · Boeing 767424ERSDR AALA20170715005Ballast · inoperativeTHE AIRCRAFT WAS GROUNDED. ELECTRICAL FUMES/ODOR IN THE CABIN AROUND ROWS 7,8, AND 9 DURING ARRIVAL TO DFW. NUMEROUS CIRCUIT BREAKERS ARE PULLED PER QRH. AN EMERGENCY WAS DECLARED AND THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. FOUND ROW 6-9 OVERHEAD LIGHT OJul 15, 2017 · N9630A · Doug MD83SDR IPXA2017071719411Light · inoperativeLAV AUX MIRROR LIGHT INOP. RELAMPED LAV AUX MIRROR LIGHT IN REF TO AMM 33-51-21-0401 OPS CK GOOD.Jul 14, 2017 · N168UP · Airbus A300F4622RSDR AALA201707179036Light · burned outTHE AIRCRAFT WAS NOT GROUNDED. ELECTRICAL SMELL COMING FROM CEILING VENT LEFT SIDE OUTSIDE BUSINESS GALLEY. T/S SYSTEMS FOR ELECTRICAL LIKE SMELL IN BUSINESS GALLEY LEFT AND RIGHT AREA. FOUND CEILING FLORESCENT TUBE BURNED OUT ABOVE COFFEE MAKERS LEFT SIDE OJul 14, 2017 · N794AN · Boeing 777223SDR DALA2017071405435Light · hotFORWARD CREW REST UPPER ENTRY CLOSET, CAPTAIN'S SIDE CLOSET LIGHT BULB BURNED THROUGH LENS COVER (DEFORMED BY HEAT). REPLACED LIGHT BULB AND LIGHT SWITCH.Jul 13, 2017 · N866DA · Boeing 777232SDR DALA2017071805532Light · sparksSPARKS IN AFT LEFT LAVATORY FROM LIGHT. COMPLIED WITH ERA 560231-14, REPLACED THE SWITCH . CHECKED GOOD.Jul 12, 2017 · N917DL · Doug MD88SDR DALA2017071305434Light · shortedFLUORESCENT BULB SHORTED CAUSING FUMES IN F/A CREW REST AREA. REPLACED CREW REST NR 2 BUNK LIGHT ASSEMBLY.Jul 12, 2017 · N863DA · Boeing 777232SDR HALA2017071100182Socket · odorELEC ODOR IN THE R2 LAVATORY. REPLACED THE LIGHT SOCKET IAW AMM 33-26-00-962-001 AND OPS CHECKED SATISFACTORY.Jul 10, 2017 · N590HA · Boeing 7673CBSDR AALA201706239004Ballast · inoperativeUNUSUAL ODOR IN MID CABIN, ROW 16. FOUND A BAD LIGHT BALLAST. REMOVED AND REPLACED THE BALLAST.Jun 22, 2017 · N711UW · Airbus A319112SDR SWAA2017062614606Ballast · faultyDURING CRUISE, FLIGHT ATTENDANT NOTICED SMOKE EMERGING FROM FORWARD COFFEEMAKER. CONTINUED TO PRODUCE SMOKE UNTIL PRIOR TO LANDING. EMERGENCY DECLARED AND DIVERTED. R & R BALLAST IAW WDM & CMM.Jun 20, 2017 · N222WN · Boeing 7377H4SDR CALA2017061601844Ballast · odorDURNIG FLIGHT, NOTICED ELECTRICAL ODOR FROM ROW 47 WHICH MIGRATED TO AFT GALLEY. CREW TURN OFF CABIN LIGHING AND AFT GALLEY POWER AND ROW 49 WAS REPORTED BY FLIGHT ATTENDANT ALSO. ODOR HAS DISAPPEARED, NOT ACTIVE IAW CREW. CONFIRMED ELECTRICAL ODOR COMING Jun 16, 2017 · N777UA · Boeing 777222SDR DALA2017061204653Ballast · miswiredAFT STAIRWAY FLUORESCENT LIGHT FOUND INOPERATIVE. FOUND THE BALLAST MISWIRED. CONNECTED LEFT BALLAST IAW WDM 33-23-01. OPS CHECKED OK.Jun 11, 2017 · N933DL · Doug MD88SDR AALA201705309057Unknown · inoperativeOVERWING EMERGENCY ESCAPE HATCH INTERIOR LIGHTS FORWARD AND AFT, LEFT AND RIGHT ARE INOPERATIVE. RESET SYSTEM LIGHTS IAW AMM 33-51-00. OPERATIONAL CHECKED GOOD.May 29, 2017 · N383AN · Boeing 767323SDR CALA2017052601579Socket · burnedELECTRICAL ODOR IN LAVATORY 4L, FOUND THE LIGHT SOCKET BURNED OVER THE SINK. REPLACED THE SOCKET IAW WDM 33-26-16. OPS NORMAL. OK TO CONTINUE.May 26, 2017 · N78002 · Boeing 777224SDR HNAA2017051800170Light · smokeSMOKE REPORTED FROM ABOVE BIN 3AC. CABIN OVERHEAD LIGHTING DEACTIVATED. SP 33.1 HAS BEEN COMPLIED WITH. EMERGENCY DECLARED. COMPLIED WITH SP 33.1, CIRCUIT BREAKERS PULLED AND COLLARED.May 16, 2017 · N330EN · Dhav DHC8311SDR VNAA2017061700001Ballast · odorELECTRICAL ODOR IN CARGO BIN ABOVE 21 ABC. REMOVED AND REPLACED THE BALLAST.May 14, 2017 · N510AE · Cndair CL6002C10SDR HNAA2017051200165Holder · arcedWHEN CABIN OVERHEAD LIGHTS ARE ON, AN ELECTRICAL ODOR IS NOTICED IN MID CABIN. MAINTENANCE INSPECTED AND FOUND THE OVERHEAD LIGHT AT 3A ARCING. INSPECTED AREA NO FURTHER DAMAGE NOTED. DEACTIVATED OVERHEAD LIGHTS. PULLED AND COLLARED CIRCUIT BREAKERS S1 - S2 May 11, 2017 · N335EN · Dhav DHC8311SDR JJBA20170511026Light · smokeNOTICEABLE ELECTRICAL SMELL/SMOKE WHEN TURNING ON SIDEWALL LIGHTS. R&R PASSENGER SIDEWALL LIGHT ASSY AT SEAT 3A. OPS CHECK SAT. NO OTHER DEFECTS NOTED.May 11, 2017 · N14171 · Emb EMB145XRSDR IPXA2017051116977Lamp · inoperativeLAVATORY AUX MIRROR LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-21-0401. OPS CHECKED GOOD.May 10, 2017 · N168UP · Airbus A300F4622RSDR WX0A2017051273248Light · contaminatedFA REPORTED A BURNING ODOR FROM 10000 FT THRU LANDING AND TAXI IN. NOTICED OVERHEAD READING LIGHT IN AFT GALLEY FLICKERING. NO VISIBLE SMOKE NOTED. FOUND AFT GALLEY OVERHEAD PANEL LIGHT MODULE & EWIS HAD CONTAMINATION CLEANED CONTAMINATION.May 10, 2017 · N228NV · Airbus A320214SDR SWIA201743292Light · shortedAIRCRAFT RETURNED TO THE FIELD WITH THE A LAVATORY SMOKE ALARM ACTIVATED. FLT ATTENDANT FOUND NO SMOKE IN THE LAVATORY. JUST AFTER TAKEOFF. TROUBLESHOT AND FOUND LAVATORY LIGHTED ORDINANCE SIGN TO BE SHORTING TO A FRAME SCREW. REMOVED AND REPLACED THE THE May 8, 2017 · N864AS · Cndair CL6002B19SDR WX0A073247Bulb · failedBURNED RUBBER ODOR ON TAKE OFF FROM BOTH FORWARD & AFT FA STATIONS. R & R THE BULB.May 1, 2017 · N864GA · Doug DC983SDR DALA2017050103529Bulb · contaminatedPASSENGER READING LIGHT AT SEAT 37F SMOKES WHEN ON. FOUND BULB COVERED WITH DEBRIS FROM FOOD REPLACED THE BULB, OPS NORMAL.Apr 30, 2017 · N843MH · Boeing 767432ERSDR SWAA2017042513316Ballast · failedPOSSIBLE ELECTRICAL SMOKE ODOR IN COCKPIT AND FRONT GALLEY. R & R CABIN LIGHT BALLAST IAW AMM.Apr 25, 2017 · N237WN · Boeing 7377H4SDR MASA2017042012750Ballast · defectiveBURNING SMELL AT ROW 14AC. FOUND BALLAST CAUSING SMELL, DE-ACTIVATED AND PLACED ON MEL.Apr 20, 2017 · N242LR · Cndair CL6002D24SDR AALA201704219011Ballast · failedDURING APPROACH, FLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR IN THE CEILING AREA BETWEEN AFT LAVATORIES. LASTED 5 MINUTES AND THEN GONE. FOUND CEILING LIGHT BALLAST TO BE SOURCE OF ODOR. REPLACED THE LIGHT BALLAST IAW AMM 33-21-00. AIRCRAFT WAS GROUNDED.Apr 19, 2017 · N167US · Airbus A321211SDR AALA201704199020Cover · damagedGALLEY LIGHT COVER BROKEN OFF. STRAIGHTENED LIGHT COVER AND INSTALLED, OK FOR SERVICE. THE AIRCRAFT WAS NOT GROUNDED.Apr 18, 2017 · N907NN · Boeing 737823SDR SWAA2017041813159Ballast · failedDURING CRUISE FLIGHT AT FL380, RECEIVED AN INTERCOM CALL FROM FLIGHT ATTENDANTS ADVISING OF AN ELECTRICAL ODOR IN THE RT CABIN BETWEEN ROWS 5 & 6. EMERGENCY DECLARED AND RETURNED TO DEPARTURE. FOUND OVERHEAD CEILING LIGHT AT 2ABC INOPERATIVE, THE LIGHT BALLApr 13, 2017 · N795SW · Boeing 7377H4SDR A6WA201744919Ballast · failedELECTRICAL BURNING ODOR IN CABIN, POWERED AIRCRAFT DOWN. FOUND CEILING LIGHT BALLAST ABOVE ROW 11AC DISCOLORED. DISCCONNECTED THE BALLAST IAW AMM 33-21-10.Apr 11, 2017 · N436AW · Cndair CL6002B19SDR IPXA2017041016000Lamp · inoperativeLAVATORY AUXILIARY LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-21-0401. OPS CHECKED GOOD.Apr 8, 2017 · N159UP · Airbus A300F4622RSDR ASOA201704045031Lamp · burned outPILOT REPORTED AN ELECTRICAL ODOR IN FWD CLOSET. MX REMOVED AND REPLACED TWO BURNED OUT GALLEY WORK AREA FLOURESCENT LAMPS. PERFORMED GENERAL VISUAL INSPECTION OF CLOSET ACCESS PANEL TO CONTACTORS AND TCAS COMPUTER AREA NO DAMAGE FOUND. NO ELECTRICAL ODOR NApr 4, 2017 · N11544 · Emb EMB145LRSDR CALA2017040400816Ballast · faultyA/C LEFT EMER EXIT ROW WALL LIGHTS OUT. REMOVE AND REPLACED LIGHT AND BALLAST ASSY ON SIDEWALL BY ROW 20 A IAW AMM 33-21-30. OPS CHECK GOOD.Apr 4, 2017 · N14102 · Boeing 757224SDR A6WA2017033144903Ballast · failedA STRONG ODOR OF BURNING PLASTIC IN GALLEY AREA. INSPECTED GALLEY LIGHT , BALLAST, AND VENTILLATION IAW AMM 33-26-AND 25-21 NO ODORS DETECTED . INSPECTED SIDEWALL BALLAST IN OVERHEAD BIN 3DF, AND FOUND THE BALLAST WARM TO THE TOUCH AND ASSOCIATED LIGHTS BURNMar 30, 2017 · N471ZW · Bombdr CL6002D15SDR QXEA2017033000194Light · odorSTRONG ELECTRICAL SMELL MID CABIN AFTER PARKING. UNABLE TO SMELL ANY UNUSUAL SMELLS IN CABIN. WHEN MID CABIN "NO SMOKING" ANNUNCIATOR PANEL WAS REMOVED, WAS ABLE TO SMELL SMALL RESIDUAL "BURNT" SMELL WHEN PANEL WAS HELD CLOSE TO NOSE. RELAMPED MID CABIN "NO SMMar 30, 2017 · N412QX · Bombdr DHC8402SDR AALA201703289017Lamp · failedAFT FLIGHT ATTENDANT JUMPSEAT WORK LIGHT FLASHING ON AND OFF CONTINOUSLEY. REPLACED THE LAMP IAW AMM 33-27-00.Mar 26, 2017 · N649AW · Airbus A320232SDR AALA201703289037Light · burnedAT LAV E MIRROR LIGHT BURNED. REMOVED AND REPLACED AT LAV E MIRROR LIGHT IAW AMM 33-26-03. THE AIRCRAFT WAS NOT GROUNDED.Mar 24, 2017 · N897NN · Boeing 737823SDR AALA201703239026Light · burnedCEILING LIGHT AT LAVATORY 3F-1R IS BURNED. REMOVED AND REPLACED CEILING LIGHT AT LAVATORY 3F-1RIAW AMM 33-26-00. GOOD FOR SVC. THE AIRCRAFT WAS NOT GROUNDED.Mar 21, 2017 · N754AN · Boeing 777223SDR DALA2017032202356Light · smokeSMOKE OBSERVED WHEN AFT GALLEY WORK LIGHT WAS TURNED ON. RELAMPED AFT RIGHT GALLEY WORK LIGHT PER AMM. NO EVIDENCE OF SMOKE NOTED.Mar 21, 2017 · N833MH · Boeing 767432ERSDR AALA201703229026Light · overheatedLAV D MIRROR LIGHT BURNED. REPLACED MIRROR LIGHT LAV D IAW AMM 33-26-03, GOOD FOR SERVICE. THE AIRCRAFT WAS NOT GROUNDED.Mar 20, 2017 · N884NN · Boeing 737823SDR AALA201703219013Ballast · failedELECTRICAL SMOKE ODOR DURING CRUISE 350. FOUND A BAD BALLAST AT 2L DOOR CEILING LIGHT. REPLACED LIGHT ASSEMBLY. AIRCRAFT WAS GROUNDED.Mar 20, 2017 · N551UW · Airbus A321231SDR ASOA201703183049Light · burnedBURNING ELECTRICAL ODOR FORWARD FRONT OF CABIN. FOUND ROW 7A SIDE WALL LIGHT RETAINER TO BE BURNING. REMOVED THE LIGHT IAW AMM 33-21-06.Mar 18, 2017 · N23139 · Emb EMB145XR
Back to JASC 3320