JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR PNSA2015040803Light · smokeSMOKE IN CABIN DURING CLIMB OUT, CAME FROM SEAM ALONG WALL BETWEEN SEATS 1A & 2A. REPLACED BOTH LAMP HOLDERS TO FLUORESCENT LAMP AT 2A.SDR PNSA2015040702Light · burnedSMELL OF BURNING METAL & INSULATION DETECTED IN THE PROXIMITY OF SEAT 1A. FLIGHT ATTENDANT SAW HAZE AT ONE POINT. INSPECTED ROWS 1 & 2 FOR BURNT AREAS, FOUND 3 WINDOW BULBS BURNT. R & R 3 BULBS IN 1 DF & 2 DF.SDR QMLA2015040515025Light · contaminatedBURNING PLASTIC SMELL IN CABIN COMING FROM OVERHEAD LIGHTING, NO SMOKE OR FIRE IN CABIN. LIGHTS TURNED OFF, CABIN VENTILATED & SMELLS DISSIPATED. GRASS WAS FOUND IMBEDDED IN OVERHEAD LIGHT FROM THE FRESH AIR VENT.SDR IPXA2015033187571Switch · inoperativeLIGHT INOPERATIVE IN CREW STORAGE AREA AT CREW ENTRY, FIRST AID KIT CLOSET, RELAMPED NO HELP SUSPECT HAD LIGHT ASSY DG 1028466, 3/28/15/. R & R LIGHT ASSY IAW MM 35-51-21-0401 - NO HELP. SWITCH AT UPPER DOOR ORDERED AND AT 5A. DG 1028466 3/30/15. R & R MICRSDR USAA2015033100008Power Supply · faultyELECTRICAL SMELL COMING FROM SOMEWHERE IN FWD GALLEY. REPLACED EPSU IN THE FWD GALLEY.SDR IPXA2015032787465Light · inoperativeLAV AUX/MIRROR LIGHT INOPERATIVE RELAMPED REF AMM33-51-21-401.SDR CA150327004Ballast · burned(CAN) AFTER ARRIVAL OF THE ACFT AT THE GATE, A HAZE AND ELECTRICAL SMOKE WAS OBSERVED BY THE CREW AND PASSENGERS AHEAD OF THE MID GALLEY. MAINTENANCE HAD MET THE FLIGHT AND WERE ABLE TO ISOLATE THE CAUSE TO AN ELECTRICAL BALLAST LOCATED ABOVE SEAT 5A. THE BASDR FDEA201503251086Sign · looseEXIT SIGN OVER DOOR 1L IS DANGLING LOOSE. REATTACHED COVER ON EXIT SIGN ON L1 DOOR IAW SMP. OK FOR SERVICE.SDR IPXA2015032487370Lamp · inoperativeLAV MIRROR LIGHT INOPERATIVE. REPLACED THE LAMP IAW AMM 33-51-21-401.SDR CALA2015032593481Ballast · defectiveCREW REPORT ELEC ODOR & SMOKE IN AREA OF FWD LAVATORY E & GALLEY. ISOLATED FWD BALLAST BETWEEN FWD GALLEY & LAVATORY. INSPECTED ALL GALLEYS, LAVATORY’S, EE COMPARTMENT & FLIGHT DECK. R & R FWD DIRECT LIGHTING BALLAST M656 WITH SERVICEABLE UNIT. OPERATIONS SDR FDEA201503211042Indicator · damagedSOCKET ASSEMBLY FOR R1, DOOR DISARM, LIGHT IS BROKEN. R & R INDICATOR ASSEMBLY IAW SMP 20-00-00. OPERATIONS NORMAL.SDR FDEA201503211041Indicator · damagedSOCKET ASSEMBLY FOR L1 DOOR DISARM LIGHT IS BROKEN. R & R LT FWD ENTRY DOOR DISARM LIGHT SOCKET ASSEMBLY IAW LMMS SM 52-11-0 S1-S2 & IPC 52-11--75-02 ITEM 420. TESTED NORMAL ON GND.SDR IPXA2015032087231Lamp · inoperativeLAV AUX/MIRROR LIGHT INOPERATIVE, RELAMPED. OPS CK GOOD.SDR CA150318012Ballast · burned(CAN) AS REPORTED BY CABIN CREW, ODOR OF BURNING WIRES VERY STRONG AROUND ROW 20 AND 21. FOUND BALLAST AT 21AC WITH BLOWN FUSE AND BURNED ELECTRICAL ODOR. REPLACED BALLAST AND CHECKED SERVICE.SDR IPXA2015031687081Light · inoperativeLAV AUX/MIRROR LIGHT INOPERATIVE, REPLACED THE LAMP IAW AMM 33-51-21-401.SDR FDEA201503080741Light · inoperativeTEST FLIGHT, R1 DOOR SLIDE, ARMED SEGMENT LIGHT INOPERATIVE. RE LAMPED BULBS IN R1 SLIDE LIGHT ASSEMBLY IAW AMM 33-16-02-2. TESTED GOOD IAW AMM 33-22-00-5.SDR CA150415011Ballast · burned(CAN) DURING MAINTENANCE TAXI, THEY NOTICED A STRONG BURNING ODOR. FOUND BALLAST BURNED.SDR REXA2015030700287Dimmer · odorODOR OF ELECTRICAL BURNING IN INTERIOR REAR OF ACFT, VERY STRONG ODOR. REPLACED POWER UNIT/DIMMER B127 FOR CEILING LIGHTS. OPS CHECKS GOOD IAW AMM 33-21-04.SDR WX0A2015031672467Ballast · defectiveJUST AFTER BOTH ENGS WERE STARTED FLIGHT ATTENDANTS & PAX'S COMPLAINED OF SMOKE SMELL FROM ROW 15 ALL THE WAY TO AFT OF THE AIRPLANE. ONE PAX SAID THEY SAW SMOKE AT 16AC. APU WAS STILL RUNNING. NO SMOKE WARNINGS IN COCKPIT OR CABIN. FOUND BALLAST AT 16AC HASDR SIMA20150220005Lamp · odorDURING TAXI IN, FLIGHT ATTENDANT REPORTED ELECTRICAL BURNING ODOR IN THE FWD PORTION OF CABIN. REPLACED LAMP IN COURTESY LGIHT. COURTESY LIGHT OPS GOOD IAW AMM 30-26-00-700-801-A.SDR ASOA2015030512323Housing · brokenSERVICE DOOR SURROUND PANELS 232AZ/BZ, 232CZ AND 232DZ REQUIRE REPAINT. UPON FURTHER INVESTIGATION, FOUND PANEL 232CZ C/C HSG ASSY BROKEN. REMOVED & INSTALLED SERVICEABLE C/C HSG ASSY ON PANEL 232CZ IAW AMM 33-51-05-000-801 & 35-51-05-400-801 TR 33-0173 & 33SDR IPXA2015021886062Lamp · burned outLAV MIRROR LT INOPERATIVE REPLACED LAMP IAW AMM 33-51-21. CKS GOOD.SDR HNAA2015021300042Bulb · failedSMELLED ELECTRICAL SMOKE IN CABIN WITH APU ON. INSPECTED INNER CABIN AREA, OVERHEAD LIGHT, BALLAST AND SURROUNDING WIRING. FOUND LIGHT BULB TUBES AT ROW 6DF AND 5AC BE SUSPECTED. R & R BULBS. NO SMOKE OR ODOR NOTICED. OK FOR SERVICE.SDR CA150224028Bulb · shorted(CAN) SMALL AMOUNT OF SMOKE NOTED EMITTING FROM READING LIGHT IN SEATS 5A/B IN FLIGHT, AIRCRAFT RETURNED TO BASE AND BULB WAS REPLACED RECTIFYING THE DEFECT. SMS INVESTIGATION LEAD TO THE SUSPICION THAT THE BULB WAS AN UNAPPROVED OR COUNTERFEIT PART (PICTURES SDR ASOA20150128008Light · smokeTHE CREW REPORTED SMOKE IN CABIN COMING FROM VICINITY OF SEAT 4A. MAINTENANCE INSPECTED AND REPLACED SEAT 4A SIDEWALL CABIN LIGHT ASSY. OPS CHECKS WERE GOOD.SDR DALA2015012900745Ballast · failedAFT LT LAV HAS STRONG CHEMICAL ODOR GOING INTO AFT GALLEY. R & R AFT LAV LIGHT BALLAST.SDR REXA2015012200068Light · inoperativeFLIGHT ATTENDANT NOTIFICATION LIGHT ON FWD FACE OF CTR EMER EXIT CEILING LIGHT FOR PAX CALL INOPERATIVE. R & R BULB, PN ON & OFF 6839, NSN, IAW AMM 33-51-14. OPERATIONS CHECKED GOOD.SDR HNAA2015012000023Lens · meltedODOR FOUND IN WARDROBE. WARDROBE COURTESY LIGHT LENS WAS FOUND TO BE MELTED. R & R BULB AND LENS IAW 25-28-00. OPS CHECKED GOOD.SDR WX0A2015012672370Ballast · faultyAIRCRAFT OUT OF SERVICE UNTIL 01/25. SHORTLY AFTER TAKEOFF BOTH LAVATORY SMOKE ALARMS WENT OFF. FLIGHT ATTENDANTS REPORTED BURNING SMELL. COMPLIED WITH QRH 26.9 & RETURNED TO FIELD. MULTIPLE CBS PULLED IAW CHECKLIST. COMPLIED WITH WO 00244014 & 00244013. SDR DALA2015012200537Cover · meltedDURING FLIGHT, THE F/A REPORTED AN ACRID ODOR AROUND SEAT ROW 26. THE OVERHEAD LIGHTS WERE SHUTOFF AND THE ODOR DISSIPATED. MAINTENANCE FOUND CABIN FLOOD LIGHT COVER AT ROW 26 IN CONTACT WITH NIGHT LIGHT. REPOSITIONED NIGHT LIGHT. OPS CHECKS NORMAL. AIRCRAFTSDR N6WA2015011601Ballast · hotAFT LAVATORY SMOKE WARNING IN FLIGHT. VISUALLY INSPECTED ALL ELEC COMPONENTS IN LAVATORY & FOUND LAVATORY VANITY BALLAST TO BE UNUSUALLY HOT. R & R LAVATORY VANITY BALLAST IAW AMM 33-25-05. R & R LAVATORY VANITY LIGHT BULBS IAW AMM 33-25-03. OPERATIONS CHESDR USAA2015012000013Ballast · burnedON DESCENT FLIGHT ATTENDANT REPORTED BURNING PLASTIC SMELL IN GALLEY. CAPTAIN CONFIRMED BURNING WIRE INSULATION SMELL FROM BEHIND COFFEE POT. FOUND GALLEY LIGHT BALLAST WITH STRONG ELEC SMELL. REPLACED BALLAST IAW AMM 25-35-34.SDR ASOA20150111002Light · faultyTHE CREW REPORTED ELECTRICAL BURNING ODOR AND SMOKE FROM PSU AND SEAT 10C/D. MAINTENANCE INSPECTED AND REPLACED THE PASSENGER SIDE WALL LIGHT ASSY OPS CHECKS WERE GOOD.SDR N6WA2015011001Ballast · malfunctionedAFT LAVATORY SMOKE MASTER WARNING IN FLIGHT. FOUND BURNING SMELL COMING FROM LAVATORY LIGHT BALLAST. R & R LAVATORY BALLAST IAW AMM 33-25-05. OPERATIONS CHECKED GOOD.SDR USAA2014123000002Ballast · deterioratedEN-ROUTE SMOKE OBSERVED FOR 10 SEC, AFT GALLEY A/C LT MIDWAY IN GALLEY OVER TOP OF LAST REMOVABLE BIN. COULD NOT DUPLICATE THE PROBLEM, HOWEVER, AN AFT WORK LIGHT BALLAST CONDITION WAS FOUND DETERIORATED. THE BALLAST WAS REPLACED.SDR 2WAA20141222001Socket · damagedDURING DESCENT, AFT ROW 20 ELECTRICAL ODOR. INSPECTED AREA FOUND LAMP HOLDER DAMAGED. R & R HOLDER IAW AMM 33-21-03. OPS CHECKED NORMAL IAW AMM 33-21-03, NO DEFECTS NOTED.SDR SCNA20141223248Floor Support · crackedFWD WET AREA BETWEEN BS 328-344, LBL 11 FLOOR SUPPORT HAS CORROSION. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED FLOOR SUPPORT AND FABRICATED AND INSTALLED NEW FLOOR SUPPORT.SDR ASOA20141215101Ballast · faultyTHE CREW REPORTED ELECTRICAL ODOR FROM ROWS 4 AND 5. MAINTENANCE INSPECTED AND REPLACED THE LIGHT BALLASTS. OPS CHECKED GOOD.SDR ASOA20141214148HBallast · overheatedTHE CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE CABIN. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE R & R THE LIGHT BALLAST ON RO 19 AND 21, OPERATIONALLY TESTED WITH NO DEFECTS AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR S9BA201412150015Socket · overheatedBURNING ODOR IN FWD CABIN REPORTED BY F/A DURING CRUISE AT 15,000 FT. NO ABNORMAL COCKPIT INDICATIONS. ODOR WAS EVIDENT IN ALL OF ZONE A, GALLEY. OPENED BOTH ENGINE COWLS FOR VISUAL INSPECTION, NO DEFECTS NOTED. INSPECTED CABIN COMPARTMENT FOR ANY SIGNS OF SDR SCNA20141223249Floor Support · crackedFWD WET AREA BETWEEN BS 312-328, LBL 46 FLOOR SUPPORT HAS A CRACK. R & R THE FLOOR SUPPORT.SDR ASOA20141129095CSocket · burnedTHE CREW REPORTED A BURNING ODOR COMING FROM THE COFFEEMAKERS. MAINTENANCE INSPECTED AND FOUND NO DEFECT WITH COFFEEMAKERS. FOUND CEILING LIGHT SOCKET BURNED AT SEAT 2A.SDR ASOA0141123136Light · burnedTHE CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE FRONT OF THE CABIN AND FLIGHT DECK DURING FLIGHT. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE ACFT AND PLACED CABIN LIGHTING ON MEL33-20-00-1, CAT C, AND THE ACFT WAS APPROVED FOR RETURNSDR SIMA20141123002Power Unit · faultyFLIGHT ATTENDANTS SMELLED FAINT ELECTRICAL HOT SMELL ON LT SIDE OF CABIN NEAR ROWS 13 & 14. R & R POWER UNIT & DIMMER AT SEAT ROW 12AB IAW AMM 33-21-03. OPERATIONS CHECKED GOOD NO SMELLS NOTED.SDR S9BA2014112000014Socket · overheatedF/A AND PAX COMPLAINED OF BURNING ODOR IN CABIN. RETURNED TO GATE. R & R PAX SEAT 5A POSITION UPPER FLUORESCENT LIGHT, AFT LAMP HOLDER IAW WIRING MANUAL 20-20-15. OPS CHECK GOOD IAW AMM 33-21-05-04-1.SDR IPXA2014112184888Lamp · inoperativeLAV MIRROR AUX LIGHT INOPERATIVE, REPLACED THE LAMP IAW AMM 33-51-21-401.SDR WX0A2014111872265Holder · unsecureELECTRICAL BURNING SMELL COMING FROM ROW 30DEF, FLIGHT ATTENDANT'S TURNED OFF LIGHTS & SMELL WENT AWAY. FOUND LOWER SIDEWALL BALLAST HOLDER AT 30DEF RESTING ON PANEL. SECURED & LOCKED BALLAST HOLDER TO RAIL. OPERATIONS CHECKED OK IAW AMM 33-21-03.SDR ASOA20141111132Light · odorTHE CREW REPORTED AN ELECTRICAL BURNING ODOR FROM THE LAVATORY LIGHT AFTER THE LATCH WAS CLOSED. THE ACFT LANDED WITHOUT INCIDENT. R & R THE LIGHT BALLAST, OPS TESTED WITH NO DEFECTS NOTED AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CA141110006Ballast · failed(CAN) AIRCRAFT WAS IN DESCENT TROUGH 11000FT WHEN THE ON-BOARD AME REPORTED A STRONG ELECTRICAL OVERHEAT SMELL IN THE CABIN BUT NO SMOKE AS THE SOURCE COULD NOT BE CONFIRMED, AN IMMEDIATES DECISION TO TERMINATE FLIGHT AND LAND THE AIRCRAFT IMMEDIATELY WAS MADESDR CHQA20141104320Ballast · damagedBURNING SMELL NEAR ROW 3C. REPLACED THE FWD GALLEY CEILING LIGHT BALLAST. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECT NOTED.
Back to JASC 3320