SDR ASOA20141028129Bulb · shortedTHE CREW REPORTED A STRONG BURNING ELECTRICAL ODOR IN THE VICINITY OF ROW 22. THE ACFT LANDED WITHOUT INCIDENT WHERE MAINTENANCE R & R A SHORTED LIGHT BULB AT ROW 22, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 28, 2014 · N16919 · Emb EMB145LRSDR C41R201410270001Diode · burnedAIRCRAFT WAS UNDERGOING AN ANNUAL INSPECTION. OWNER REPORTED CABIN LIGHTS INOPERATIVE AT 50 PERCENT. TROUBLESHOT CABIN LIGHTNING SYSTEM. FOUND DIMMING INTERFACE UNIT INOPERATIVE. INSTALLED NEW INTERFACE UNIT. AFTER 10 MINUTES OF FUNCTIONAL CHECKS THE INTERFOct 27, 2014 · N888CG · Pilats PC1245SDR MASA2014102502690Ballast · failedELECTRICAL ARCING ODOR AT FWD LAV IN FLIGHT. MAINTENANCE REPLACED FWD LAV BALLAST.Oct 25, 2014 · N939LR · Cndair CL6002D24SDR SCNA20141103160Floor Support · crackedFLOOR SUPPORT CRACKED AT FORWARD WET AREA BETWEEN BS 328 - 344 LBL 48. R & R THE FLOOR SUPPORT.Oct 22, 2014 · N716SY · Boeing 737752SDR CHQA20141022300Ballast · defectiveELECTRICAL BURNING ODOR WAS PRESENT IN THE CABIN IN FLIGHT. THE LIGHTING BALLAST AT SEAT 1A WAS FOUND TO BE CAUSING THE ODOR & WAS DEFERRED. THE DEFERRAL WAS CLEARED ON 10/26/2014 WHEN MX REPLACED THE LIGHTING BALLAST. OPERATIONAL CHECKS WERE GOOD WITH NO FOct 22, 2014 · N568RP · Emb EMB145LRSDR CA141022005Light · contaminated(CAN) DURING THE CRUISE PORTION OF THE FLIGHT THE FLIGHT ATTENDANT INFORMED PILOT OF A BURNING SMELL IN THE AFT LAVATORY. SOON AFTER THEY INFORMED THE PILOT THAT THERE WAS SMOKE COMING FROM THE CEILING. A DIVERSION WAS INITIATED TO THE NEAREST AIRPORT (YQT). SOct 21, 2014 · Boeing 737*SDR CALA2014101701350Ballast · malfunctionedSMOKE IN CABIN AROUND ROW 25, FOUND ROW 25DEF CEILING LIGHT INOPERATIVE. REPLACED LIGHT & BALLAST. OPERATIONS CHECKED NORMAL. ACCOMPLISHED SMOKE ODOR INSPECTION IAW AMM 05-51-58. NO OTHER DEFECTS NOTED.Oct 17, 2014 · N57870 · Boeing 75733NSDR ASOA20141012128Control Module · overheatedTHE CREW REPORTED A BURNING ODOR COMING FROM THE CABIN LIGHT MODULE. LANDED WITHOUT INCIDENT AND MAINTENANCE R & R THE CABIN LIGHT CONTROL MODULE, OPS TESTED WITH NO DEFECTS NOTED AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 12, 2014 · N14974 · Emb EMB145LRSDR ASOA20141011127Control Module · inoperativeTHER CREW REPORTED A STRONG ELECTRICAL ODOR FROM THE GALLEY AREA. LANDED WITHOUT INCIDENT AND MAINTENANCE R & R THE LIGHT CONTROL MODULE, AND CABIN LIGHT BALLAST, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 11, 2014 · N14977 · Emb EMB145LRSDR ASOA20141011126Ballast · inoperativeCREW REPORTED A STRONG ELECTRICAL ODOR FROM THE GALLEY AREA. LANDED WITHOUT INCIDENT AND MAINTENANCE R & R THE LIGHT CONTROL MODULE, AND CABIN LIGHT BALLAST, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 11, 2014 · N14977 · Emb EMB145LRSDR SIMA20141008007Ballast · faultySTRONG SULFUR SMELL EN ROUTE, MID CABIN. R & R ROW 4A PSU LIGHT BALLAST IAW AMM 33-21-03. NO STRONG SMELL NOTED.Oct 8, 2014 · N657AE · Emb EMB145LRSDR A6WA201442036Ballast · inoperativeSTRONG BURNING SMELL IN CABIN, MOST STRONG BETWEEN ROW 4 & 5. INSPECTED CEILING LIGHT BALLAST & FOUND MUPT BALLASTS INOPERATIVE. NO SIGN OF BURNS, PULLED & COLLARD CB P2 S4 IAW 272909 2 FOR MEL.Oct 7, 2014 · N436AW · Cndair CL6002B19SDR SIMA20141002004Ballast · odorSTRONG ELEC SMOKE SMELL IN COCKPIT. FLIGHT ATTENDANT STATED STRONG ELEC SMOKE SMELL COMING FROM GALLEY AREA. DECLARED EMER WITH ATC, EMER EVAC ON RUNWAY. PERFORMED FIM TASKS 72--00-00. OPERATIONS CHECKED GOOD SEE NRWC 687-DFW-01907 FOR R & R OF GALLEY LIGHOct 2, 2014 · N687JS · Emb EMB145LRSDR SIMA20141002003Ballast · odorBALLAST IN GALLEY HAVE STRONG ELEC BURNING SMELL. R & R BOTH BALLASTS IN GALLEY IAW MM 33-29-05. OPERATIONS CHECKED GOOD.Oct 2, 2014 · N687JS · Emb EMB145LRSDR SWAA2014100132510Light · faultyDIVERSION AT FL380 FLIGHT ATTENDANT REPORTED ODOR OF SMOKE AROUND ROW 2 ABC &DEF. R & R LIGHT ASSEMBLY IAW MM.Sep 29, 2014 · N712SW · Boeing 7377H4SDR SWAA2014093032419Light · faultyON DESCENT FLIGHT ATTENDANTS REPORTED SMELLS SIMILAR TO SMOKE & INCENSE FROM OVERHEAD 7E. R & R BULB IAW MM.Sep 29, 2014 · N7739A · Boeing 7377BDSDR QMLA2014092814118Power Supply · shortedLAUNCHING ON A SCENE FLIGHT, ON STARTUP THE LANDING LIGHT CB POPPED & WAS RESET ONCE. THE STARTUP WAS COMPLETED. AFTER TAKEOFF THE NURSE SMELLED A BURNT WIRE SMELL & THEN THE REST OF THE CREW CONFIRMED THE SMELL. THE PILOT IMMEDIATELY RETURNED TO BASE APPROSep 28, 2014 · N408LN · Bell 407SDR ASOA20140923082CSocket · burnedTHE CREW REPORTED STRONG ELECTRICAL BURNING ODOR WITH BOTH PACKS RUNNING. MAINTENANCE FOUND BURNED LIGHT SOCKET AT ROW 5A. THE ACFT WAS RELEASED FOR SERVICE IAW MEL. SUPPLEMENT TO FOLLOW.Sep 23, 2014 · N25134 · Emb EMB145XRSDR SWAA2014092932348Light · inoperativeLEFT FLUORESCENT LIGHTS BETWEEN ROWS 4 TO ROWS 7 WENT OUT & PRODUCED A STRONG ACRID SMELL & LIGHT SMOKE. R & R LIGHT IAW MM.Sep 22, 2014 · N613SW · Boeing 7373H4SDR SIMA20140916009Light · smokeWHEN READING LIGHT AT 3A WAS TURNED ON IT FLICKERED & STARTED TO SMELL OF SMOKE, IT WAS TURNED OFF & SMELL DISSIPATED. FLIGHT CREW PLACARDED IAW MEL 25-20. R & R SEAT 3A READING LIGHT ASSEMBLY IAW AMM 33-25-02, OPERATIONS CHECKED GOOD. MEL ITEM RESTORED M PSep 16, 2014 · N680AE · Emb EMB145LRSDR ASOA20140913102Switch · shortedCREW REPORTED PSU LIGHT AT 6D SMOKING AND FLICKERING COULD NOT TURN OFF. MAINTENANCE R & R 6D PSU LIGHT WITH NO FIX. DISCONNECTED SWITCH AND PLACED ON NEF CB02. MX R & R 6D PSU LIGHT SWITCH WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Sep 13, 2014 · N14960 · Emb EMB145LRSDR JJBA20140912006Light · smokeSMOKE COMING OUT OF SECOND AIR STAIR DOOR LIGHT FROM THE TOP. DEFERRED IAW MEL.Sep 12, 2014 · N375PH · Dhav DHC8202SDR DALA2014091405035Light · sparksFLIGHT CREW REPORTED THAT SIDEWALL LIGHTS AT ROW 32A WERE SPARKING. MAINTENANCE R & R LIGHT ASSEMBLY IAW AMM.Sep 10, 2014 · N911DA · Doug MD9030SDR SIMA20140905002Socket · burnedDURING TAXI FLIGHT ATTENDANT REPORTS BURNING SMELL IN GALLEY. INSPECTED GALLEY AREA & FOUND ALL LIGHTS & SYS WORKING PROPERLY. FOUND 1A CEILING LIGHT SOCKET BURNT. REMOVED LAMPS IAW AMM 33-21-06 & DEFERRED IAW MEL 33-2.Sep 5, 2014 · N616AE · Emb EMB145LRSDR RAIA201408310001Ballast · failedBURNING ODOR NOTICED AROUND SEAT 9-10C POSSIBLY COMING FROM SIDEWALL LIGHT AT 10C. MAINTENANCE INSPECTED AND DEFERRED SIDEWALL LIGHT AT ROW 8, 9. MAINTENANCE REPLACED THE SIDEWALL LIGHT BALLAST, OPS CHECKED GOOD.Aug 31, 2014 · N802HK · Emb EMB145EPSDR SWAA2014090231454Ballast · malfunctionedAIR TURN BACK FLIGHT ATTENDANTS REPORTED STRONG SMELL OF BURNING RUBBER IN AFT GALLEY. R & R BALLAST IAW MM.Aug 30, 2014 · N395SW · Boeing 7373H4SDR AALA20140824005Ballast · shorted3L LAVATORY OVER MIRROR LIGHT TUBE SHORTED OUT. INBD TUBE PLUG MELTED & BURNED. REPLACED 3L LAVATORY LIGHT ASSEMBLY & BALLAST. OPERATIONS CHECKED NORMAL.Aug 24, 2014 · N772AN · Boeing 777223SDR ASOA20140822091Light · odorCREW REPORTED A SMOKE ODOR COMING FROM CABIN BETWEEN ROW 19A AND 20A. MAINTENANCE R & R SEAT 19A/20A CABIN LIGHT ASSY WITH OPS CHECK GOOD AND NO FURTHER BURNING SMELL NOTICED. ACFT WAS APPROVED FOR RETURN TO SERVICE.Aug 22, 2014 · N11140 · Emb EMB145XRSDR CALA2014082892039Light · odorELECTRICAL HOT ODOR NEAR SEAT 7G, FOUND SMELL COMING FROM LIGHT ASSEMBLY BALLAST ABOVE SEATS. REPLACED LIGHT ASSEMBLY ABOVE DOOR 2R FOUND TO BE BAD. REPLACED ASSEMBLY & ONE EACH LAMPS FWD & AFT OF ASSEMBLY. OPERATIONS CHECKED GOOD NO SMELL NOTED IAW MM-33-2Aug 21, 2014 · N792UA · Boeing 777222SDR CALA2014082592017Ballast · defectiveELECTRICAL HOT ODOR NEAR SEAT 7G. INSPECTED AREA ABOVE MID GALLEY & ABOVE SEATS 7KJ. FOUND SMELL COMING FROM LIGHT ASSEMBLY BALLAST. REPLACED BALLAST.Aug 21, 2014 · N792UA · Boeing 777222SDR YYFA20140821002Circuit Breaker · trippedPASSENGER WARNING CB W-30 KEEPS POPPING OUT. NO CHIME ON SEAT BELTS SWITCH AFTER TAKEOFF.Aug 21, 2014 · N836NK · Doug MD83SDR HNAA2014081800238Ballast · failedCABIN INTERIOR NORMAL LIGHTING SYSTEM, FOUND OVERHEAD BALLAST BURNED AT ROW 7DF. DEACTIVATED ASSOCIATED LIGHT SYS. PULLED AND COLLARED CIRCUIT BREAKERS R1, S1 AND S2 IAW SPM 33.1.Aug 18, 2014 · N805EX · Dhav DHC8102SDR WX0A2014082272106Light · missingDOOR MOUNTED ESCAPE SYS GIRT BAR ENGAGEMENT LIGHT MISSING FROM DOOR 4R. RE-INSTALLED MISSING LIGHT. OPERATIONS CHECKED GOOD IAW AMM 33-20-00.Aug 17, 2014 · N902NV · Boeing 757204SDR ASOA20140810065Ballast · faultyTHE CREW REPORTED AN ELECTRICAL ODOR NEAR SEAT 2B. MAINTENANCE INSPECTED AND REPLACED GALLEY LIGHT BALLAST. OPS CHECKS WERE GOOD.Aug 10, 2014 · N22971 · Emb EMB145SDR ASOA20140803101Light · overheatedTHE F/A REPORTED A BURNING ODOR IN THE CABIN ASSOCIATED WITH THE F/O'S SIDE FLOOR AND WALL LIGHTING FLICKERING. MAINTENANCE INSPECTED THE ACFT AND R & R THE AFFECTED WALL LIGHTS, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Aug 3, 2014 · N13978 · Emb EMB145LRSDR N6WA20140731001Light · inoperativePAX DOOR STAIR LIGHT INOPERATIVE. DEFERRED PAX DOOR LIGHT IAW MEL 33-21-02 CAT D.Jul 31, 2014 · N331CA · Cndair CL6002C10SDR SIMA20140729001Ballast · burnedSMOKE IN CABIN FROM MULTIPLE PSU'S. DURING TROUBLESHOOTING FOUND PSU BALLAST BETWEEN SEATS 14A - 15A BURNED. R & R BALLAST IAW AMM 33-21-05. OPERATIONS CHECKED OK.Jul 29, 2014 · N837AE · Emb EMB135KLSDR ASOA20140728060Housing · faultyTHE CREW REPORTED LAVATORY SMOKE WARNING, ELECTRICAL FIRE ODOR IN AND AROUND LAV. LAVATORY LIGHT WARM TO TOUCH. MAINTENANCE INSPECTED AND REPLACED THE LAVATORY LIGHT LAMP HOUSING. OPS CHECKED GOOD.Jul 28, 2014 · N14923 · Emb EMB145LRSDR N6WA20140724004Light · inoperativePAX DOOR STAIR ENTRANCE LIGHT INOPERATIVE. DEFERRED STAIR ENTRANCE LIGHT IAW MEL 33-21-02 CAT D.Jul 24, 2014 · N331CA · Cndair CL6002C10SDR WX0A2014070972012Light · malfunctionedELECTRICAL SMELL UNKNOWN ORIGIN. R & R OVERHEAD LIGHT BASE AT 14L IAW 20-10-01. OPERATIONS TESTED GOOD.Jul 8, 2014 · N411NV · Doug MD83SDR CHQA20140701204Lamp Socket · defectiveCREW REPORTED THAT THE BALLAST LIGHT BULB ABOVE ROW 6A BURNT OUT DURING FLIGHT & CAUSED A MINOR HAZE IN THE CABIN. THE ACFT LANDED AT ITS INTENDED DESTINATION WITHOUT FURTHER INCIDENT. MX DEFERRED THE LIGHT SOCKET. THE DEFERRAL WAS CLEARED ON 7/2/14 WHEN MXJul 1, 2014 · N274SK · Emb EMB145LRSDR CHQA20140701203Light · burned outCREW REPORTED THAT THE BALLAST LIGHT BULB ABOVE ROW 6A BURNT OUT DURING FLIGHT & CAUSED A MINOR HAZE IN THE CABIN. THE ACFT LANDED AT ITS INTENDED DESTINATION WITHOUT FURTHER INCIDENT. MX DEFERRED THE LIGHT SOCKET. THE DEFERRAL WAS CLEARED ON 7/2/14 WHEN MXJul 1, 2014 · N274SK · Emb EMB145LRSDR ASOA20140701087Bulb · failedTHE F/A REPORTED THE LIGHT AT SEAT 2A WAS FLICKERING AND HAD AN ELECTRICAL BURNING ODOR. MAINTENANCE R & R THE BULB, OPERATED CABIN LIGHTS WITH NO DEFECTS OR ODORS NOTED, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Jul 1, 2014 · N14514 · Emb EMB135LRSDR SIMA20140624008Ballast · faultyPASSENGERS & FLIGHT ATTENDANT REPORTED STRONG BURNING ODOR IN CABIN BY ROWS 6 - 8. FOUND SIDEWALL LIGHT BALLAST ABOVE ROW 7AB BURNT. R & R BALLAST IAW AMM 33-21-03. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED AT THIS TIME IAW FIM 21-22-00.Jun 24, 2014 · N504AE · Cndair CL6002C10SDR N6WA20140624001Lens · missingBLUE CALL LIGHT LENS MISSING ON CEILING EMER EXIT SIGN AT ROW 12. DEFERRED ON NEF 25-100-12 CAT C. NO DEFECTS NOTED AT THIS TIME, OK FOR SERVICE.Jun 24, 2014 · N658CA · Cndair CL6002C10SDR ASOA20140622048Controller · odorTHE CREW REPORTED AN ELECTRICAL BURNING ODOR IN CABIN. MAINTENANCE INSPECTED AND REPLACED THE CABIN LIGHT CONTROLLER. OPS CHECKED GOOD.Jun 22, 2014 · N16963 · Emb EMB145LRSDR A6WA201441658Ballast · defectiveACRID BURNING SMELL IN VICINITY OF ROW 10 & 11, UNABLE TO IDENTIFY SOURCE. ONLY OCCURRED ON GND DURING BOARDING. BOTH BALLAST ROW 10 RT SIDE DISCONNECTED. RAN APU WITH BOTH PACKS ON FOR 10 MINUTES & ALL CABIN LIGHTS ON, NO MORE BURNING SMELL. RT SIDE CTR AJun 16, 2014 · N414ZW · Cndair CL6002B19SDR CALA2014062091326Socket · damagedIAW A CHECK DOOR 5R, FWD SILL LIGHT INOPERATIVE. LIGHT SOCKET IS SPINNING. REPLACED LIGHT ASSEMBLY. OPERATIONS CHECKED OK.Jun 15, 2014 · N107UA · Boeing 747422SDR SWIA201438744Lamp · inoperativeFWD GALLEY AREA LIGHT IS INOPERATIVE. C-CHECK, R & R LAMP IN FWD GALLEY LIGHT IAW AMM.Jun 13, 2014 · N560SW · Emb EMB120ERSDR SWIA2014061738205Ballast · failedELECTRICAL TYPE BURNING ODOR NEAR SEAT 23D. CHANGED BALLAST AT 23D FOR SIDEWALL AND OVERHEAD LIGHTS IAW AMM. OPS CHECKED GOOD.Jun 13, 2014 · N745SK · Cndair CL6002C10
Back to JASC 3320