SDR SIMA20190126006Light · crackedNR 5 EMERGENCY FLOOR PROXIMITY STRIP LIGHT ASSY CRACKED. C/A-COMPLETE:REPLACED NR 5 EMERGENCY FLOOR PROXIMITY STRIP LIGHT ASSY IAW AMM 33-50-12, REFERENCE BOW 314230 FOR OPS CHECK.SDR REXA2019012960067Lamp · inoperativeDURING ROUTINE CHECK LH EMERGENCY LIGHT OUT (3RD BACK FROM FRONT OF AIRCRAFT). RELAMPED LH 3RD (GOING BACK) EMERGENCY LIGHT IAW AMM 33-51-21. OPC GOOD.SDR DALA2019020180673Lens · damaged(AIRCRAFT 7004, L/P 0919748) WORKING INSPECTION OF EEPLS LENSES, FOUND EMERGENCY LOWER FLOOR PROXIMITY LIGHT ASSY DAMAGED, AFT OF FLIGHT ATTENDANT CREW REST DOOR. REMOVED AND REPLACED LOWER PROXIMITY LIGHT ASSY.SDR R61A201901260127Warning System · false activationEMERGENCY LIGHT BATTERY FAULT ON EICAS. COMPLIED WITH FIM TASK 33-50-00-810-803-A. RESET CBS MAU 2 NR 1 NR 2 POWER CBS PRI MAU 2 POWER 2 SEC MAU 3 POWER 1 2, MESSAGE CLEARED.SDR DALA2019012800601Sign · brokenDURING INSPECTION FOUND L1 DOOR EMER EXIT SIGN BROKEN. MAINTENANCE REPLACED EMER EXIT SIGN AND BASE.SDR SWAA2019012828890Battery Pack · dischargedFORWARD LT CABIN EMERGENCY LIGHT INOP. R&R BATTERY PACK PER AMM.SDR SIMA20190126003Light · damagedRT FUSELAGE EMERGENCY LIGHT DAMAGED. C/A-REMOVED AND REPLACED RT FUSELAGE EMERGENCY LIGHT ASSY. REF. AMM 33-50-10. OPS CHECK GOOD.SDR AALA201901289032Light · inoperativeEMERGENCY LIGHT AT18 LEFT WAS INOPERATIVE. REPLACED THE LIGHT IAW AMM 33-51-19. OPS OK.SDR FDEA2019012950206Unknown · unknownMDIS 663 33-50 0722 25JAN19 PIT OPEN U COURIER AREA EMERGENCY LIGHT TEST INOP. FACT 01FEB19 16:15 BWI MALFUNCTION NOT VERIFIED. SYSTEM CKS GOOD PER A300 SDR AALA2019013125010Light · no testCOCKPIT EMERGENCY LIGHT FAILED TO COME ON WITH STANDY POWER LOSS, REPLACED THE COCKPIT EMERGENCY LIGHT ASSEMBLY IAW AMM 33-51-01. OPS CHECKED GOOD.SDR WX0A2019020473377Light · inoperativeL1 & L2 SLIDE LIGHTS FAILED . FOUND DISCONTINUITY BETWEEN THE EMERGENCY LIGHT 41WL & CONNECTOR 2761VC, CONNECTED THE LIGHT.SDR DALA2019020180668Light · missing(AIRCRAFT 7101, L/P 5575170) EMERGENCY LIGHT ASSY MISSING AT SEAT 53F. INSTALLED EMERGENCY LIGHT ASSY @ PAX SEAT 53F. OPS CK NML. REF B777 AMM 33-51. OK FOR SVC.SDR DALA2019012500665Light · none(AIRCRAFT 7004, L/P 5338771) MTC RECEIVED VERBAC REPORT FROM CLEANING CREW THAT DOOR 4L/R EMERGENCY LTS WERE ON. UPON ENTERING DR4L/R LOCATION FOUND EMERGENCY LTS NOT ILLUMINATED. PERFORMED OPS TEST PER B777 AMM33-51. LTS AT DOOR 4 L/R CHECK OK.SDR ASAA2019012527943Battery Pack · dischargedEMERGENCY EVACUATION AISLE LIGHTS AT 28 DEF AND 30 DEF INOP DURING LIGHT TEST. GROUNDED - YES. REPLACED EMERGENCY LIGHT BATTERY PACK M1899. OPERATIONAL TEST PASSES REF AMM 33-51-06-960-806.SDR SWAA2019012828906Battery · failedEMERGENCY LIGHT BATTERIES FAILED CAPACITY TEST AT LOCATION M1668. R&R BATTERY PER AMM.SDR SWAA2019012828903Battery · failedEMERGENCY LIGHT BATTERIES FAILED CAPACITY TEST AT LOCATION M1674. R&R BATTERY PER AMM.SDR SWAA2019012828894Cover · unsecureCEILING MID CABIN AFT FACING EMERGENCY EXIT SIGN COVER FELL OFF. INSTALLED SIGN PER MM.SDR DALA2019012600572Lens · missingTHE EMERGENCY EXIT COVER DIFFUSER LENS IS MISSING AT 29B. MAINTENANCE INSTALLED THE LENS COVER. CHECK IS GOOD. (LP #0918194)SDR DALA2019012600562Battery · dischargedTHE OVERWING EXIT EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE FORWARD EMERGENCY BATTERY AND REPLACED THE AFT EMERGENCY POWER SUPPLY PER AMM 33-51. OPERATIONAL CHECK WAS GOOD. (LP #4289937)SDR IPXA2019012638337Power Supply · inoperativeINSPECTION TYPE:N/A SUPERNUMERARY EMERGENCY LITES FAIL TO TEST. REPLACED EMER POWER SUPPLY UNIT PER MM 33-51-14-401. OPS CHKS NML.SDR MASA2019012511683Light · inoperative14A EMERGENCY EXIT SIGN 1 BULB INOP. RELAMPED.SDR AALA20190125002Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT EMERGENCY EXIT LIGHTING FAILED OPERATIONAL CHECK, DID NOT ILLUMINATE. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT PER AMM 33-51-38 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR SWAA2019012828964Battery Pack · inoperativeBATTERY PACK INOP AT LOCATION M2335. R&R BATTERY PACK PER AMM.SDR SWAA2019012828963Battery Pack · inoperativeBATTERY PACK INOP AT LOCATION M1673. R&R BATTERY PACK PER AMM.SDR SWAA2019012828959Battery Pack · inoperativeBATTERY PACK INOP AT LOCATION M1670. R&R BATTERY PACK PER AMM.SDR SWAA2019012828908Battery · dischargedCENTER CABIN EMERGENCY AISLE LIGHT INOP AT LOCATION M1669. R&R BATTERY PER AMM.SDR SWAA2019012828891Ballast · inoperativeRT EMERGENCY EXIT SIDE WALL LIGHT INOP AT ROW 12. R&R LIGHT BALLAST IAW AMM.SDR SWAA2019012828887Battery · dischargedCENTER CABIN EMERGENCY AISLE LIGHT INOP AT LOCATION M2335. R&R BATTERY PER AMM.SDR DALA2019012400551Battery Pack · dischargedSHIP 649 F/C SEATS EMERGENCY LIGHT INOP. CORRECTIVE ACTION: RPLD EMER LIGHT BATTERY PACK OP CK NRML IAW AMM 33-51. (5068785)SDR AALA2019012859003Sign · inoperativeEMERGENCY EXIT SIGN WAS INOPERATIVE AT THE L1 DOOR. REPLACED EXIT SIGN ASSEMBLY, AND POWER SUPPLY IAW AMM 33-51-14. OPS CHECKED GOOD IAW AMM 33-51-06.SDR UIEA2019012603032Battery Pack · dischargedSEVERAL EMERGENCY LIGHTS INOPERATIVE(<P>RELAMPED R1, R5, L2, L4 DOOR SILL LIGHTS. REMOVED AND REPLACED M9058 BATTERY PACK FOR RT / LT CEILING EXIT SIGNS ROW 19. CORRECTED ROUTING OF SEATS 31, 32, 21 RT POWER CABLES.</P>)SDR CALA2019012500154Power Supply · failedREF NR LP 9130032- B777-33-3-0022, DOOR L3 EMERG LIGHT PWR SUPPLY M33400 FOUND CAPACITY LOW. DR L3 EMERG LIGHT M33400 BATTERY PACK AND POWER SUPPLY REPLACED. OPERATIONAL TESTED NORMAL AS PER AMM33-51-06 DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 3 FOR ACCSDR CALA2019012500153Power Supply · failedREF NR LP 9130678- B777-33-3-0018, DOOR 3L EMERG LIGHT POWER SUPPLY M33405 CHARGER DEEP CYCLE FAIL. DR 3L EMERG LIGHT M33405 POWER SUPPLY REPLACED, OPERATIONAL TESTED NORMAL AS PER AMM33-51-06 DETAIL REFER ATTACH FORM44-0008 ITEM 1 TO ITEM 2 FOR ACCOMPLISHED.SDR CALA2019012500151Power Supply · low voltageREF NR LP 9130028- B777-33-3-0022, R2 DOOR EMERG LIGHT PWR SUPPLY M33098 FOUND CAPACITY LOW. R2 DOOR EMERG LIGHT M33098 BATTERY PACK AND POWER SUPPLY REPLACED, OPERATIONAL TESTED NORMAL PER AMM33-51-06 DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 3 FOR ACCOSDR CALA2019012500164Charger · inoperativeREF NR LP 9132182- B777-33-3-0022 GALLEY G9 AFT PROX LIGHT DIM GALLEY G9 AFT PROX LIGHT POWER SUPPLY M33408 CHARGER REPLACED AND TESTED NORMAL PER AMM 33-51-06 DETAIL REFER ATTACH FORM 44-0008 ITEM 1 AND ITEM 2 FOR ACCOMPLISHED.SDR CALA2019012500163Charger · inoperativeREF NR LP 9132172- SUPPORT TASK- CABIN MID ZONE PARTITION BOTH SIDE EMERG LIGHT DIM. CABIN MID ZONE PARTITION BOTH SIDE EMERG LIGHT BATTERY PACK AND CHARGER SUPPLY REPLACED. OPERATONAL TESTED NORMAL AS PER AMM 33-51-06. DETAIL REFER ATTACH FORM 44-0008 ITEM 1 SDR CALA2019012500162Battery Pack · dischargedREF NR LP 9132191- B777-33-3-0018 DOOR R4 EMER LIGHT POWER SUPPLY M33408 BATTERY PACK TEST FAIL. DOOR R4 EMERG LIGHT POWER SUPPLY M33408 BATTERY PACK REPLACED AND OPERATIONAL TESTED NORMAL PER AMM 33-51-06. DETAIL REFER ATTACH FORM 44-0008 ITEM 1 AND ITEM 2 FOSDR CALA2019012500161Battery · dischargedREF NR LP 9130679- B777-33-3-0018, DOOR 3L EMERG LIGHT POWER SUPPLY M33405 BATTERY FOUND CAPACITY LOW. DOOR L3 EMERG LIGHT M33405 BATTERY PACK REPLACED, OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06, DETAIL REFER ATTACH FORM44-0008 ITEM 1 TO ITEM 2 FOR ACCOMPLSDR CALA2019012500160Battery · dischargedREF NR LP 9130680- B777-33-3-0018, DOOR 3R EMERG LIGHT POWER SUPPLY M33404 BATTERY FOUND CAPACITY LOW. DR 3R EMERG LIGHT M33404 BATTERY PACK REPLACED, OPERATIONAL TEST NORMAL AS PER AMM 33-51-06, DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 2 FOR ACCOMPLISHSDR CALA2019012500159Battery Pack · dischargedREF NR LP 9130030- B777-33-3-0022, DOOR R2 EMERG LIGHT PWR SUPPLY M33097 FOUND CAPACITY LOW. DR R2 EMERG LIGHT M33097 BATTERY PACK AND POWER SUPPLY REPLACED, OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06, DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 3 FOR ASDR CALA2019012500158Battery Pack · dischargedREF NR LP 9130026- B777-33-3-0022, R4 DOOR SLIDE LIGHT FOUND INOP. R4 DOOR SLIDE LIGHT BATTERY PACK AND LAMP REPLACED, OPERATIONAL TESTED NORMAL PER AMM33-51-06 DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 3 FOR ACCOMPLISHED.SDR CALA2019012500157Battery Pack · low voltageREF NR LP 9130027- B777-33-3-0022, L1 DOOR EMERG LIGHT PWR SUPPLY M33424 FOUND CAPACITY LOW. L1 DOOR EMERG LIGHT M33424 BATTERY PACK AND POWER SUPPLY REPLACED. OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06 DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 3 FORSDR CALA2019012500156Power Supply · low voltageREF NR LP 9130031- B777-33-3-0022, DOOR 3L EMERG LIGHT PWR SUPPLY M33406 FOUND CAPACITY LOW. DOOR L3 EMERG LIGHT BATTERY PACK AND CHARGER ASSY (M33406) REPLACED. OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06 DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 3 FOSDR CALA2019012500155Power Supply · low voltageREF NR LP9130029- B777-33-3-0022, DOOR L2 EMERG LIGHT POWER SUPPLY M33096 FOUND CAPACITY LOW. DOOR L2 EMERG LIGHT M33096 BATTERY PACK AND POWER SUPPLY REPLACED, OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06 DETAIL REFER ATTACH FORM 44-0008 ITEM 1 TO ITEM 3 FORSDR SIMA20190124001Light · inoperativeMAIN DOOR OVERHEAD EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED MAIN DOOR OVERHEAD EMERGENCY LIGHT LAMP IAW AMM TASK 33-50-06-000-801-A AND 33-50-06-400-801-A. OPC GOOD, NO DEFECTS NOTED. END.SDR JJBA20190124035Battery Pack · defectiveLT AND RT OVER WING EMERGENCY LIGHTS INOPERATIVE. TROUBLESHOT LT AND RT OVER WING EMERGENCY LIGHTS. FOUND WIRES W170-8278-22 AND W170-8279-22N BROKEN, REPLACED WIRED. OPS CHECK FAILED. REMOVED AND REPLACED NR 4 EMERGENCY LIGHT BATTERY CHASSIS ASSEMBLY. OPS CHESDR SWAA2019020529167Light · brokenL1 DOOR EMERGENCY EXIT LIGHT ON FORWARD LAV BROKEN. R&R LIGHT IAW AMM.SDR AALA201901249005Battery Pack · no testOPERATIONAL TEST OF THE EMERGENCY LIGHTS FAILED. MAINTENANCE REPLACED THE BATTTERY PACK IAW AMM 33-51-38, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR SIMA20190123002Light · inoperativeRT OVER WING EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED BULB ON RT OVERWING EMERGENCY LIGHT IAW AMM 33-50-10. OCK GOOD.SDR SIMA20190123003Light · inoperativeLT OVER WING EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED BULB ON LT OVERWING EMERGENCY LIGHT IAW AMM 33-50-10. OCK GOOD.
Back to JASC 3350