SDR SWAA2018052922285Battery Pack · dischargedR1 DOOR EMERGENCY LIGHT INOP. R&R BATTERY PACK IAW AMM.SDR SWAA2018052922284Cover · missingAFT BULKHEAD EMERGENCY LIGHTING COVER MISSING. INSTALLED COVER PER MM.SDR AALA201805299025Power Supply · no testEMERGENCY POWER SUPPLY UNIT WL14 FAILED A SYSTEM TEST. MAINTENANCE REPLACED THE POWER SUPPLY BATTERY AND PERFORMED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-38.SDR R61A2018052950621Light · unsecureFLOOR EMERGENYC LIGHT STRIP WAS DISPLACED. SECURED THE FWD RT EMERGENCY LIGHT IAW AMM 33-50-01.SDR SIMA201805295002Light · inoperativeROWS 5 & 6A EMERGENCY LIGHT WAS INOPERATIVE. R & R THE EMERGENCY LIGHT IAW AMM 33-50-12, OPS CHECKED GOOD.SDR SIMA201805295001Lamp · inoperativeROW 16 CEILING EMERGENCY LIGHT WAS INOPERATIVE. R & R THE LAMP IAW AMM 33-50-08. OPS CHECKED GOOD.SDR I5EA2018052900008Charger · inoperativeLEFT ROW 13 INTERIOR EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED THE BATTERY CHARGER M1134 IAW AMM 33-51-51, OPS CHECKED GOODSDR I5EA201805290007Charger · inoperativeLEFT FWD OVERWING EXIT EXTERNAL LIGHT INOPERATIVE. REMOVED AND REPLACED THE BATTERY CHARGER M1134 IAW AMM 33-51-51. OPS CHECKED GOODSDR AALA20180525005Battery Pack · dischargedAIRCRAFT IN BASE MAINTENANCE. L2 DOOR BATTERY PACK FAILS OPERATIONS CHECK. REPLACED L2 DOOR EMERGENCY POWER SUPPLY BATTERY PACK (M33096) PER AMM 33-51-06-960-802. OPERATIONS CHECK GOOD.SDR AALA20180525004Power Supply · inoperativeAIRCRAFT IN BASE MAINTENANCE. L1 DOOR BATTERY PACK FAILED OPERATIONS CHECK. REPLACED L1 DOOR EMERGENCY LIGHT POWER SUPPLY (M33093) PER AMM 33-51-06-960-802. PERFORMED SATISFACTORY OPERATIONS CHECKS.SDR DALA2018052503603Battery · dischargedCEILING EMER LIGHTS AT ROWS 26-31 INOP. REPLACED BATTERIES AT PACK B5-106. OPS CK OK.SDR DALA2018052503602Battery · dischargedON SERVICE CHECK- EMERGENCY LIGHTS AT L1, R1, AND COCKPIT OVERHEAD DID NOT REMAIN ON. REPLACED EMERGENCY LIGHT BATTERIES IN FWD DROP DOWN PNL. OPS CHECKS GOOD AMM 33-53.SDR MASA2018052513255Light · inoperativeCEILING EMER FLOOD LIGHT INOP ROW 3. REPLACED LIGHT BULBS.SDR HALA0218052500258Cids · malfunctionedTHE R3 DOOR EXIT SIGN WAS FOUND INOPERATIVE. RESET CIDS, PERFORMED AN OPS CHECK OF THE EMERGENCY LIGHTS. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA2018061504032Light · detachedDURING INSPECTION, FOUND THE EMERGENCY EXIT AISLE LIGHT AT SEAT 23D WAS HANGING DOWN BY THE WIRE. MAINTENANCE REPLACED SEAT SHROUD/BUMPER IAW CMM 25-27-48.SDR CALA2018060531355Battery · dischargedEPSU BATTERY, AFT LEFT 13WL FAILED AN EMERGENCY LIGHTS OPS TEST. REMOVED AND REPLACED THE BATTERY 13WL IAW AMM 33-51-38-4 00-008A. ACCOMPLISHED AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS IAW AMM 33-51-00-710-001A, TESTED OK.SDR SWAA2018053022279Light · inoperativeFLIGHT DECK " EMERGENCY LIGHT" IN CEILING INOP. INSTALLED LAMP IAW AMM.SDR SWAA2018053022243Lens · brokenL2 DOOR EXIT LIGHT COVER BROKEN. SECURED LENS PER EA.SDR YENA201805240227Epsu · failedDURING HEAVY MAINTENANCE, OPERATIONAL TEST OF EMER LIGHTS FAILED DURING TEST. REPAIRED 3 EA EPSU'S AT (10WL-11WL AND 12WL) AND 1 BATTERY AT (10WL) IAW AMM 33-51-38-000-001-A. SYS OPS CKS NORMAL.SDR YENA201805240226Epsu · failedDURING HEAVY MAINTENANCE, OPERATIONAL TEST OF EMER LIGHTS FAILED DURING TEST. REPAIRED 3 EA EPSU'S AT (10WL-11WL AND 12WL) AND 1 BATTERY AT (10WL) IAW AMM 33-51-38-000-001-A. SYS OPS CKS NORMAL.SDR YENA201805240225Epsu · failedDURING HEAVY MAINTENANCE, OPERATIONAL TEST OF EMER LIGHTS FAILED DURING TEST. REPAIRED 3 EA EPSU'S AT (10WL-11WL AND 12WL) AND 1 BATTERY AT (10WL) IAW AMM 33-51-38-000-001-A. SYS OPS CKS NORMAL.SDR YENA201805294224Battery Pack · failedOPS TEST OF THE EMERGENCY LIGHTS FAILED. REPAIRED THREE POWER SUPPLIES, 10WL, 11WL, AND 12WL) AND ONE BATTERY 10WL IAW AMM 33-51-38-000-001-A. SYS OPS CHECKED NORMAL.SDR AALA2018052989019Light · damagedWALL MOUNTED EMERGENCY LIGHT AT THE R1 DOOR WAS FOUND DAMAGED. REPLACED THE EMERGENCY LIGHT IAW AMM 33-51-13.SDR AALA2018052989029Light · inoperativeAFT GALLEY FORWARD WALL EMERGENCY PROXIMITY LIGHT INOPERATIVE. REPLACED PROXIMITY LIGHT IAW MM 33-51-06.SDR AALA201805259013Cids · malfunctionedEMERGENCY LIGHTS AT THE L3 DOOR AND CEILING WERE ILLUMINATED. MAINTENANCE RESET CIDS AND PERFORMED SATISFACTORY OPERATIONAL CHECK IAW AMM 33-52-00, FAULT COULD NOT BE DUPLICATED.SDR 29GA2018052500003Bulb · inoperativeARM LIGHT ON THE FLIGHT ATTENDANT LIGHT PANEL, THE EMERGENCY LIGHT SWITCH WAS INOPERATIVE. REPLACED THE LIGHT SWITCH BULB. OPS TESTED GOOD.SDR 29GA2018052500001Bulb · inoperativeARM LIGHT ON THE FLIGHT ATTENDANT LIGHT PANEL, THE EMERGENCY LIGHT SWITCH WAS INOPERATIVE. REPLACED FLIGHT ATTENDANT EMERGENCY LIGHT SWITCH BULB, OPS CHECKED GOOD.SDR DALA2018052403539Light · inoperativeLT FWD OVERWING EMER EXIT 1 BULB INOP. REPLACED LT FWD OVERWING EMER EXIT BULB PER AMM 33-50. OPS CHECK GOOD AT THIS TIME.SDR ASOA2018053025139Charger · inoperativeDURING A MX INSPECTION, THE CEILING EMERGENCY LIGHT AT PANEL 253CLC AND 263ALC WERE FOUND INOPERATIVE. MX REMOVED AND REPLACED THE NR 3 BATTERY CHARGER, OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2018053035138Light · inoperativeDURING A MX INSPECTION, THE ORANGE HALF OF THE FLOOR EMERGENCY LIGHT STRIP WAS NOT ILLUMINATING. REMOVED & REPLACED EMERGENCY LIGHT STRIP, OPS CHECKED GOOD. THE ACFT WAS APPROVED FOR RETURNED TO SERVICE.SDR AALA201805259016Warning Message · false activationEMERGENCY LIGHT POWER SUPPLY, MID RIGHT, FAULT MESSAGE FOUND DURING EMERGENCY LIGHT TEST. MAINTENANCE PERFORMED EMERGENCY LIGHT TEST IAW 33-51-00, SYSTEM BITE TESTED NORMAL, NO FAULT NOTED.SDR AALA201805249011Battery · dischargedAIRCRAFT WAS NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT TEST FAILED. REPLACED BATTERY 12WL PER 33-51-38.SDR SWAA2018052422225Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01672. R&R BATTERY PER MM.SDR SWAA2018052422224Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01670. R&R BATTERY PER MM.SDR SWAA2018052422223Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01669. R&R BATTERY PER MM.SDR SWAA2018052422206Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01673. R&R BATTERY PER MM.SDR DALA2018052403538Light · inoperativeDOOR R1 EMERGENCY LIGHT INOP. RELAMPED OPS CHECK GOOD IAW AMM 33-51.SDR MASA2018052313252Lamp · inoperativeROW 8 OVERHEAD EMERGENCY FLOOD LIGHT WAS INOPERATIVE. REPLACED THE LAMPS.SDR REXA201806050444Charger · inoperativeCABIN EMERGENCY LIGHTS DS154, DS156, AND S342 WERE INOPERATIVE. REMOVED AND REPAIRED THE NR 1 EMERGENCY LIGHT BATTERY CHARGER IAW AMM 33-21-17, OPS TESTED GOOD IAW AMM 33-51-17-710-801.SDR AALA2018060523007Connector · brokenFOUND CONNECTOR D40040P BROKEN AT THE L1 DOORWAY HEADER PANEL. REMOVED AND REPLACED THE CONNECTOR IAW SWPM 20-72-24, WDM 35-21-21, 33-51-12, AND 23-31-04. PERFORMED AN OPS TEST IAW AMM 33-51-00, 23-31-01, AND 35-22-00. OPS CHECKED GOOD. THE AIRCRAFT WAS GRSDR AALA201805249013Battery · dischargedTHE AIRCRAFT WAS NOT GROUNDED. SEAT MOUNTED EMERGENCY LIGHTS FROM SEAT 29D TO 36D ARE DIM. REPLACED BATTERY FOR AFT CABIN EMERGENCY LIGHTS PER AMM 33-51-07. OPERATIONS CHECK NORMAL.SDR AALA201805249030Battery Pack · dischargedAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK EMERGENCY LIGHT OVERHEAD PANEL INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK B5-23 AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 33-53-00.SDR DALA2018052303554Battery Pack · dischargedEMERGENCY LIGHTS ON SEAT ROW 27-32 INOP. INSTALLED SERVICEABLE BATTERY PACK & BATTERY UNIT M10568 PER AMM 33-51-07.SDR N6WA2018052202Light · inoperativeOVERHEAD EMERGENCY EXIT LIGHT OUT. REMOVED AND REPLACED NR 3 OVERHEAD EMERGENCY EXIT FLOOD LIGHT AMM 33-51-09.SDR SWAA2018052422211Cover · brokenL2 DOOR EMERGENCY LIGHT COVER BROKEN OFF. R&R LIGHT ASSEMBLY PER AMM.SDR DALA2018052403537Charger · inoperativeON SVC CK FOUND FIST CLASS EMERGENCY LIGHTS INOP. R&R FUSE AT BATTERY CHARGER IN O/H COMP ABOVE 2 CD PER WDM 33-51 AND OPS CK PER AMM 33-53 OPS CK GOOD.SDR IPXA201805239879Battery Pack · inoperativeFOUND THE EMERGENCY LIGHT TEST FAILED. R & R THE BATTERY PACK IAW AMM 33-51-01/401. PERFORMED AN EMERGENCY LIGHT TEST, FOUND TO BE SATISFACTORY.SDR SWAA2018052322203Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01675. R&R BATTERY PER AMM.SDR SWAA2018052322202Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01669. R&R BATTERY PER AMM.SDR SWAA2018052322201Battery · failedEMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK AT LOCATION M01670. R&R BATTERY PER AMM.
Back to JASC 3350