What was found
EMERGENCY POWER SUPPLY UNIT WL14 FAILED A SYSTEM TEST. MAINTENANCE REPLACED THE POWER SUPPLY BATTERY AND PERFORMED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-38.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY POWER SUPPLY UNIT WL14 FAILED A SYSTEM TEST. MAINTENANCE REPLACED THE POWER SUPPLY BATTERY AND PERFORMED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-38.