JASC 3350
Service difficulty reports · 225,786
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20240115011Lamp · inoperativeWING TO FUSELAGE FRONT FAIRING LH EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT HOUSING. OPS CHECK SAT.SDR CALA2024011500115Battery Pack · dischargedCTR PAX SEAT 45 TO 54 FLOOR PROXIMITY EMER LT FOUND DIM (BAT EQ#M734) TRANSFER REF. NON-ROUTINE HX NRC WO.2709112 AND CABIN CTR PAX SEAT 45 TO 54 FLOOR PROXIMITY EMER LT BAT PACK 33-51-07,33-51-10 ATTACHED FORM 44.0008 ITEM 1-6 ACCOMPLISHED EQ#M734 REPLACED ANSDR CALA2024011500114Battery Pack · dischargedCTR PAX SEAT 38 TO 44 FLOOR PROXIMITY EMER LT FOUND DIM (BAT EQ#M6760) TRANSFER REF. NON-ROUTINE HX NRC WO.2709094 AND EMER LT BAT PACK EQ#M6760 REPLACED AND INSTALLATION TEST FORM 44.0008 ITEM 1-2 ACCOMPLISHED. WORK ACCOMPLISHED BY CARRIED OUT NORMAL, CTR PASDR CALA2024011500113Battery Pack · dischargedCTR PAX SEAT 1 TO 6 FLOOR PROXIMITY EMER LT COME ON LESS THAN 15 MINS (BAT EQ#M6756) TRANSFER REF. NON-ROUTINE HX NRC WO.2709064 AND EMER LT BAT PACK EQ#M6756 REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL, CTR PAX SEAT 1 TO 6 FLOOR PROXIMITY EMER LTSDR CALA2024011500112Battery Pack · dischargedRH AISLE CLG PNL EMER LT ABOVE SEAT 1 TO 2 LT COME ON LESS THAN 15 MINS (BAT EQ#M730) TRANSFER REF. NON-ROUTINE HX NRC WO.2709084 AND EMER LT BAT PACK EQ#M730 REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL, CABIN RH AISLE CLG PNL EMER LT TESTED NORMAL AS PESDR CALA2024011500111Battery Pack · dischargedLH AISLE CLG PNL EMER LT ABOVE SEAT 7A TO 11A LT COME ON LESS THAN 15 MINS (BAT EQ#M7235) TRANSFER REF. NON-ROUTINE HX NRC WO.2709037 AND EMER LT BAT PACK EQ#M7235 REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL AS PER AMM 33-51-07, CABIN LH AISLE CLG EMER LSDR CALA2024011500109Battery Pack · dischargedRH AISLE CLG PNL EMER LT ABOVE SEAT 40 TO 50 LT COME ON LESS THAN 15 MINS (BAT EQ#M6760) TRANSFER REF. NON-ROUTINE HX NRC WO.2709012 AND EMER LT BAT PACK EQ#M6760 REPLACED AND BAT INSTALLATION TEST CARRIED OUT NORMAL, CABIN RH AISLE CLG EMER LT ABOVE SEAT 40 SDR MASA2024011200006Lamp · inoperativeROW 17 EMER CEILING LIGHT INOP- PLACED ON MEL- RELAMPEDSDR MASA2024011200005Lamp · inoperativeROW 1 EMER CEILING LIGHT INOP- PLACED ON MEL- RELAMPEDSDR DALA2024011700723Power Supply · faultedSHIP 3355 FOUND 4L EPSU FAULTY. MCDU BITE TEST SHOWS 4L SLIDE LIGHT FAULT. CORRECTIVE ACTION: SLAVED IN NEW SLIDE NO HELP. FOUND WIRE INTERMITTENT FROM CONNECTOR 5193VC TO 17WL. FOUND WIRE BROKE ON DOOR. REPAIRED WIRE. CKS GOOD. REINSTALLED SERVICABLE SLIDE PESDR DALA2024011700706Light · inoperativeSHIP 3409 EMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP. LOCATIONS: 20C,20G, 21C,21G,22C,22G,23C,23G - HAND RAIL LIGHTING ABOVE 20-23C AND 20-23G. CORRECTIVE ACTION: RESET LIGHTS. OK FOR SVC. (0151535)SDR DALA2024011700700Sign · unknownSHIP 3426 3L / LOCATION 605 EXIT SIGN. CORRECTIVE ACTION: 3L EXIT SIGNS OPS CHECK NORMAL. (0151560)SDR DALA2024011600622Unknown · unknownSHIP 684 EMERGENCY SEAT LIGHT COVER DAMAGED ROW 37D. CORRECTIVE ACTION: REMOVED AND REPLACED DAMAGED ELP COVER AT ROW 37 D REF B757 AMM 33-51. (5393010)SDR DALA2024011600618Unknown · unknownSHIP 694 EMERGENCY EXIT SIGN COVER LOOSE / LOCATIONS:604. CORRECTIVE ACTION: RESECURED EMERGENCY EXIT LENS COVER AS REQUIRED. (0152004)SDR DALA2024011600605Light · intermittent(LOG 5105784) EMERGENCY LIGHT INTERMITTENT AT SEAT 24R. EMERGENCY LIGHT CONNECTION AT SEAT 24R WAS FOUND LOOSE, THE LIGHT CONNECTION WAS RECONECTED CORRECTLY I.A.W. 33-51-00-501. TEST OK.SDR DALA2024011600603Battery Pack · inoperative(LOG 5636404) EMERG LIGHTS AT ROWS 1-5 INOP. R&R BATTERY PACK AT M2816. OPS CK GOOD. REF B737 AMM 33-51.SDR SCNA20240116012Battery Pack · no testDEFECT W/O 84272 NRC00005: - - PERFORMED EMERGENCY LIGHT CHECK .FOUND RH FWD DOOR #1 EXTERIOR LIGHT,INTERIOR LWR AND UPPER EXIT LIGHTS INOP.NEEDS BATTERY PACK. - - RESOLUTION: REMOVED AND REPLACED BATTERY PACK FOR RH FWD DOOR #1 EXTERIOR EMERGENCY LIGHT IAW AMSDR SCNA20240116011Battery Pack · no testDEFECT W/O 84272 NRC 00006: - - PERFORMED EMERGENCY BATTERY PACK FUNCTION CHECK.FOUND ROW 14DEF,15DEF UPPER EXIT SIGNS INOP.NEEDS BATTERY PACK. - - RESOLUTION: REMOVED AND REPLACED BATTERY PACK FOR RH WING EMERGENCY EXIT LIGHTS IAW 33-51-06. OPS CHECK GOOD.SDR JJBA20240115010Battery · inoperativeMCD EMERGENCY LIGHT OUT. REMOVED AND REPLACED MCD EMERGENCY LIGHT ASSEMBLY & BULB. OPS CHECK FAILED. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY NO 1. LIGHT OPS CHECK FAIL. FOUND BROKEN WIRE AT MCD HINGE POINT. REPAIRED WIRING. LIGHT OPS CHECK GOOD.SDR JJBA20240115009Unknown · unknownFOUND MAIN DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE INTERMITTENTLY. REMOVED MAIN DOOR EXTERNAL EMERGENCY LIGHT ASSEMBLY TO BEGIN. FOUND ISSUE TO BE THE CONTACTORS INSIDE HOUSING AND WIRING HARNESS END TERMINAL. INSTALLED EMERGENCY LIGHT ASSEMBLY ON MAIN CABINSDR SWAA2024011240321Light · inoperativeLH AFT EXIT DOOR EMERGENCY LIGHT IS INOP.<[01] REPLACED TERMINAL FOR LEFT AFT DOOR EMERGENCY LIGHT IAW SWPM 20-30-11SDR SWAA2024011240333Power Supply · inoperativeCABIN AISLE EMERGENCY LIGHT AT ROW 14DEF INOP<[01] NO VOLTAGE FOUND GOING TO LIGHT ASSEMBLY. REMOVED AND REPLACED POWER SUPPLY M1676 IAW AMM 33-51-06; OPS CHECK GOOD.SDR DXTA2024011210597Unknown · unknownEMERGENCY LIGHTS ASSOCIATED WITH #3 EMER BATT PACK ARE INOPERATIVE. PERFORMED INSPECJION OF ALL EMERGENCY POWER SUPPLIES, WIRING, G SWITCHES AND RUSES WITH NO DEFECTS NOTED. PERFORMED BATTERY EXERCISE PROCEDURE WITH NO DEFECTS NOTED AND ALL EMERGENCY UGHTS WOSDR DXTA2024011210596Battery · failedEMERGENCY LIGHTS DO NOT COME ON IN WHEN SWITCH IS SELECTED TO THE "ON" POSITION. REMOVED DEFECTIVE #4 EMERGENCY BATTERY P/N:CBS28-1, S/N:1934M AND INSTALLED A CUSTOMER SUPPLIED REPAIRED EMERGENCY BATTERY P/N:CBS28-1, S/N:6000M. PERFORMED SATISFACTORY OPERATIOSDR DXTA2024011210594Battery · faultedON PREFLIGHT WITH AIRCRAFT BATTERIES OFF AND EMERGENCY EXIT LIGHTS SELECTED TO ARM, THE EMERGENCY LIGHTS FOR OVERHEADSEAT 7 AND EVACUATION PATH LIGHTS FOR SEATS 5 AND 8 DO NOT ILLUMINATE. IF YOU SELECT AIRCRAFT BATTERIES ON AND EMER LIGHTS ON, THOSE LIGHTS NOSDR AALA202404225909Light · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY EXIT LIGHT IN CEILING ADJACENT TO MID-CABIN LAVATORY IS INOPERATIVE. **SUPPLEMENTAL REPORT FOR AALA202401165909: MAINTENANCE ACCOMPLISHED AN OPERATIONAL CHECK OF THE EMERGENCY LIGHTING SYSTEM AND COULD NOT DUPLICATE THE SDR MASA2024011100004Power Supply · inoperativeAFT EMER LIGHT" CEILING" INOP " SECOND FROM THE BACK- R/R #3 POWER SUPPLY, OPS CHECK GOOD.SDR DALA2024011600654Unknown · unknownSHIP 3358 EMERGENCY LIGHT INOP AT SEAT 37H. CORRECTIVE ACTION: REPLACED LED LIGHT ASSY, SEAT 37H. (9596161)SDR AALA202401165909Unknown · unknownAIRCRAFT IN BASE MAINTENANCE: EMERGENCY EXIT LIGHT IN CEILING ADJACENT TO MID-CABIN LAVATORY IS INOPERATIVE. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR HALA202401132003Unknown · unknownUPON PRE-FLIGHT FOUND OVHD EMER EXIT LTS FWD 1/2 INOP-DO NOT ILLUMINATE. REMOVED AND REPLACED EMER LIGHT BATTERY POWER SUPPLY PER AMM 35-51-03. OPS CHECK GOOD. OK FOR SVC.SDR HALA20240112002Unknown · unknownOVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED OVERWING EMERGENCY LIGHT BATTERY PER AMM 31-51-06. OPS CHECK GOOD. OK FOR SERVICE.SDR ASAA2024011147255Unknown · unknownEXIT LT NEAR ROW 16/17 HANGING DOWN. GROUNDED - YES. RE-INSTALLED EXIT LIGHT ASSY PER AMM 33-51-01-960-802.SDR SWAA2024011240342Sign · brokenAFT GALLEY EXIT SIGN BROKEN<[01] REPLACED MISSING SCREWS AND REINSTALLED EXIT SIGN PER AMM 33-51-01; OPS CHECK NORMAL.SDR WX0A2024011231939Unknown · unknownRIGHT OVERWING EXIT LIGHT REMAINED ON DURING CRUISE. / PERFORMED EPSU SYSTEM TEST AS PER A320 AMM 33-51-00-710-001-A. OPS CHECK GOOD, EMERGENCY LIGHTS FUNCTIONING NORMALLY."SDR AALA202401120409Light · looseAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED SEAT 16C EMERGENCY LIGHT WAS LOOSE. RESECUREDD SEAT 16C EMERGENCY LIGHT PER MM 33-51-11. OPERATIONAL CHECK GOOD.SDR AALA202401122815Battery · dischargedAIRCRAFT WAS NOT GROUNDED: FORWARD FLIGHT ATTENDANT FLASHLIGHT BATTERY LOW. REMOVED AND REPLACED FORWARD FLIGHT ATTENDANT FLASHLIGHT BATTERY. PER AMM 25-64-00.SDR AALA202401127658Sign · wrong partAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT STATES WRONG EXIT SIGNS INSTALLED ABOVE AISLE IN AFT GALLEY. REPLACE EXIT SINGS ABOUT AISLE AFT GALLEY. PER AMM 33-50-00. OPERATIONAL CHECKS NORMAL.SDR AALA202401120182Sign · detachedAIRCRAFT WAS NOT GROUNDED: AFT EMERGENCY EXIT OVERHEAD SIGN, ROW 16 FEEL OFF. REINSTALLED FORWARD EMERGENCY CEILING EXIT SIGN LENS AT ROW 16. PER AMM 33-51-01.SDR AALA202401123434Battery · missingAIRCRAFT WAS NOT GROUNDED. REF MIC 1062228 FLASHLIGHT MISSING FOR FLIGHT ATTENDANT SEAT 4R AISLE. **SUPPLEMENTAL REPORT FOR (AALA202401113434): REMOVED AND REPLACED FLASHLIGHT BATTERY. PER AMM 25-64-00, OPERATIONAL CHECK GOOD**(CLOSED).SDR CALA2024011200098Battery Pack · dischargedEMERGENCY LIGHTS BATTERY PACK M33424 AT DR L1 REPLACED AND INSTALLATION TEST CARRIED RESULT WITH NORMAL AS PER AMM 33-51-06. WORK TRANSFER NON ROUTINE WO.2612903. EMERGENCY LIGHTS BATTERY PACK M33424 AT DR L1 REPLACED AND INSTALLATION TEST CARRIED OUT RESULT SDR CALA2024011200094Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK (M33408) AT DR 4R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612915. EMERGENCY LIGHTS BATTERY PACK(M33408) AT DR 4R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06SDR CALA2024011200092Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK M33099 AT DR 2L FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612909. EMERGENCY LIGHTS BATTERY PACK M33099 AT DR 2L REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. SDR CALA2024011200090Battery Pack · dischargedB777-33-3-7019 EMERGENCY LIGHTS BATTERY PACK (M33097) AT DR 2R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612923. EMERGENCY LT BATTERY PACK (M33097) AT DR 2R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. ISDR CALA2024011200088Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK (M33401)AT DR 3R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612917. EMERGENCY LIGHTS BATTERY PACK(M33401) AT DR 3R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. SDR CALA2024011200096Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK AT LLAR FOUND CAPACITY CHECK FAIL.WORK TRANSFER NON ROUTINE WO.2612901 AND ORIGINATED BY EMP V920586. EMERGENCY LIGHTS BATTERY PACK M023 AT LLAR REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PERSDR DXTA2024011210588Unknown · unknownEMERG LIGHT SWITCH: EMERGENCY LIGHTS DO NOT WORK WHEN EMER LIGHT SWITCH IS MOVED TO THE "ON" POSITION. CHARGED BATTERIES PER THE CESSNA LETTER. BATTERIES DO NOT HOLD A CHARGE. //SIGNOFF// PERFORMED BATTERY EXERCISE PROCEDURE AS REQUESTED BY MCC. BATTERIES HELDSDR SWAA2024011139960Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK M1673 NOT CHARGING AT AFT GALLEY AREA OVERHEAD<[01] R&R?D CHARGER AND BATTERY PACK PER AMM 33-51-06SDR SWAA2024011139844Battery Pack · failedEMERGENCY LIGHT BATTERIE PACKS FAILED CAPACITY TEST AT LOCATIONS M1672;M1669; M1675; M1670 EMERGENCY LIGHT BATTERIE PACKS FAILED CAPACITY TEST AT LOCATIONS M1672M1669 M1675 M1670<[01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERIE PACKS AT LOCATIONS M1672; M166SDR SWAA2024011139884Battery Pack · inoperativeL1 INTERIOR LOWER EMERGENCY EXIT SIGN-L1 EXTERIOR EMERGENCY EXIT SLIDE LIGHT-FWD MAIN ENTRY CEILING EMERGENCY EXIT SIGN - R1 INTERIOR UPPER EMERGENCY EXIT SIGN ARE NOT HOLDING A CHARGE.<[01] REMOVED AND REPLACED BATTERY PACK AT POSITION M1675 AND PERFORMED EMESDR AALA202401113434Flashlight · missingAIRCRAFT WAS NOT GROUNDED. REF MIC 1062228 FLASHLIGHT MISSING FOR FLIGHT ATTENDANT SEAT 4R AISLE. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).
Back to JASC 3350