What was found
EMERG LIGHT SWITCH: EMERGENCY LIGHTS DO NOT WORK WHEN EMER LIGHT SWITCH IS MOVED TO THE "ON" POSITION. CHARGED BATTERIES PER THE CESSNA LETTER. BATTERIES DO NOT HOLD A CHARGE. //SIGNOFF// PERFORMED BATTERY EXERCISE PROCEDURE AS REQUESTED BY MCC. BATTERIES HELD CHARGE FOR THE REQUIRED 10 MINS. CONTACTED MCC. MCC ELECTS TO SIGN OFF DUE TO TASK CARD CHECKS GOOD. PERFORMED TOP CHARGE OF EMERGENCY BATTERIES WITH NO DEFECTS NOTED. WORK DONE IAW CE-700 AMM 33-50-00.