JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2020121601385Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK AR 24L INOPERABLE. REPLACED BTTERY PACK, AS PER AMM 3-51-07-422-012. OPERATIONS CHECKS GOOD.SDR CALA2020121601384Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK AT L1 FA SEAT INOPERABLE. REPLACED BATTERY PACK, AS PER AMM 33-51-07-422-012. OPERATIONS CHECKS GOOD.SDR CALA2020121601383Battery Pack · dischargedEMERGENCY LIGHT BATTERY PCK INOP ABOVE THE SECOND & 3RD WINDOW AFT OF L1 DOOR. REPLACED BATTERY PACK, AS PER AMM 33-51-07-422-012. OPERATIONS CHECKS GOOD.SDR CALA2020121601382Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK INOPERABLE AT DOOR R2 REPLACED BATTERY PACK, AS PER AMM 33-51-07-422-012. OPERATIONS CHECKS GOOD.SDR CALA2020121601381Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK INOPERABLE AT DOOR R2 REPLACED BATTERY PACK, AS PER AMM 33-51-07-422-012. OPERATIONS CHECKS GOOD.SDR DALA2020121504107Connector · brokenROW 40 AB EMERGENCY LIGHT INOPERABLE. CORRECTIVE ACTION: REPAIRED BROKEN CONNECTOR AT SIDE WALL, IAW A330 ESPM 20-43-11. OPERATIONS CHECK GOOD.SDR WX0A2020121573618Power Supply · no testWEEKLY CHECK CIDS1 EPSU SYS TEST BAT/EPSU 11WL FAILED TEST. REMOVED AND CLEANED CONNECTOR AT L MID BATT 11WL AND MESSAGE CLEARED FROM CIDS1, TEST OK REF TC 05-000-002 AND AMM 33-51-00. ALSO REF ESPM 20-55-40.SDR R61A2020121500876Battery · inoperativeEMERGENCY LIGHT ROW 5 NOT WORKING. R & R NR 2 EMERGENCY LIGHT BATTERY, IAW AMM 33-50-01.SDR UIEA2020121402562Lamp · inoperativeL2 DOOR EMERGENCY LIGHT INOPERABLE. RELAMPED L2 DOOR EMERGENCY LIGHT. OPERATIONS CHECK OK, IAW AMM 33-51-03.SDR UIEA2020121402564Switch · failedEMERGENCY LIGHT SWITCH INOPERABLE AT FLIGHT ATTENDANT'S PANEL BEHIND R3 DOOR. REMOVED & REPLACED P-22 "EMERGENCY LIGHT" SWITCH, PER W/D 33-51-11 AND SWPM 20-80-13. EMERGENCY LIGHT SYSTEM OPERATIONS CHECK OK, PER AMM 33-51-00/501.SDR HALA2020121500220Battery Pack · inoperativeEMER EQUIPMENT, EXTERIOR EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY, PER AMM 33-51-03. OPERATION CHECK GOOD.SDR AALA202012159009Lamp · inoperativeAIRCRAFT IN BASE MAINTENANCE. DOOR 4L EMERGENCY LIGHT DID NOT COME ON. RE-LAMPED DOOR 4L EMERGENCY LIGHT, PER AMM 33-51-00.SDR AALA202012159007Battery · failedAIRCRAFT WAS NOT GROUNDED. AFT EMERGENCY POWER SUPPLY UNIT BATTERY FAILED TEST. REPLACED AFT EMERGENCY POWER SUPPLY UNIT BATTERY, PER AMM 33-51-38.SDR AALA202012159006Lens · missingAIRCRAFT WAS NOT GROUNDED. SEAT MOUNTED EMERGENCY LIGHT LENS 8R MISSING. REPLACED SEAT 8R EMERGENCY LIGHT ASSEMBLY, PER AMM 33-51-18.SDR AALA202012159005Light · brokenAIRCRAFT IN BASE MAINTENANCE. BROKEN DOOR FRAME EMERGENCY LIGHT ASSEMBLY (LOWER POSITION) LOCATED DOOR 31, 841, 832, 842 AND LAVATORY D IN PASSENGER CABIN. REPLACED DOOR FRAME EMERGENCY LIGHT ASSEMBLY (LOWER POSITION) LOCATED DOOR 831, 841, 832, 842, AND LAVSDR AALA202012159004Power Supply · no testAIRCRAFT WAS GROUNDED. FAILS OPERATIONAL TEST OF EMERGENCY LIGHTS. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT, PER AMM 33-51-38.SDR AALA202012159002Electrical Box · inoperativeAIRCRAFT WAS NOT GROUNDED. EMERGENCY LIGHT ON SEAT 17C INOPERATIVE. REATTACH EMERGENCY LIGHT BOX TO SEAT 17C. EMERGENCY AISLE LIGHT 17C OPERATIONS CHECKED GOOD, PER AMM 33-51-11.SDR SIMA20201214003Lamp · inoperativeROW 12 OVERHEAD EMERGENCY LIGHT INOPERABLE. C/A: R & R ROW 12 OVERHEAD EMERGENCY LIGHT LAMP, IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A.SDR SIMA20201214006Charger · failedDURING REPLACING NR 3 EMERGENCY LIGHTING BATTERY CHARGER, LIGHTS WOULDN'T TURN OFF, REF NRWC 900-ORD-04750. C/A: SUSPECTED BATTERY CHARGER IS BAD STOCK. REMOVED AND REPLACED NR 3 EMERGENCY LIGHTING BATTERY CHARGER, REF EMB 145 AMM 33-50-04. OPERATIONS CHECKSDR SIMA20201214005Light · inoperativeMEL 3330-AUTH NR 120137-C 4688475/2 EMERGENCY LIGHT FLOOR STRIP NR 4 INOPERABLE. C/A: R & R FLOOR LIGHT STRIP NR 4, IAW AMM 33-50-12. OPERATIONS CHECK GOOD. MEL ITEM RESTORED.SDR SIMA20201214001Lamp · inoperativeFURTHEST AFT CABIN CEILING EMERGENCY LIGHT INOPERABLE. C/A: R & R FURTHEST AFT CABIN CEILING EMERGENCY LIGHT LAMP, IAW EMB 145 AMM 33-50-08. OPERATIONS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR AALA202012149032Battery Pack · inoperativeAIRCRAFT IN BASE MAINTENANCE. EMERGENCY LIGHT BATTERY PACK M33408 AT DOOR 5R DID NOT PASS FUNCTIONAL CHECK, IAW WORKCARD 2324. REPLACED EMERGENCY LIGHT BATTERY PACK M33408 AT DOOR 5R, IAW AMM 33-51-06. OPERATIONS CHECK GOOD.SDR MASA2020121410652Lamp · inoperativeCEILING EMERGENCY FLOODLIGHT AT ROW 11 INOPERABLE, RELAMPED.SDR MASA2020121410651Bulb · inoperativePAX DR FLOOR LEVEL EMERGENCY FLD LIGHT 1 BULB INOPERABLE. PLACED ON MEL.SDR DALA2020121404062Lens · damagedTHE EMERGENCY EXIT COVER DIFFUSER LENS IS DAMAGED OR MISSING. MAINTENANCE REPLACED THE LIGHT ASSEMBLY L2-791 FIRST CLASS MIDDLE AISLE, REF SWPM CH 20 AND B717 WDM 33-51-12. OPERATIONAL CHECK WAS GOOD.SDR JJBA20201213026Battery Pack · no testDURING OPERATIONS CHECKS OF EMERGENCY LIGHT FOUND SERVICE DOOR. EXIT IDENTIFIER, EXIT MARKER, EXIT LOCATOR ALL LOCATED IN GALLEY AREA INOPERATIVE. REMOVED AND INSTALLED NEW NR 2 BATTERY PACK AND CHARGER. EMERGENCY LIGHT OPERATION TEST GOOD.SDR SWAA2020121735918Lamp · inoperativeFWD RT EXTERIOR EMERGENCY LIGHT INOPERABLE. R & R LAMP AT FWD RT EXTERIOR EMERGENCY LIGHT, PER AMM 33-51-04.SDR YENA2020121700604Battery · failedFLT 1056, PLS-JFK. BATTERY CAPACITY TEST REQUIRED, PER TC A20 33-31-710-003. R & R EPSU BATTERY, IAW AMM 33-51-00. OPERATIONS CHECK GOOD.SDR YENA2020121700603Battery · no testFLT 1056, PLS-JFK. BATTERY CAPACITY TEST REQUIRED, PER TC A20 33-31-710-003. R & R EPSU BATTERY, IAW AMM 33-51-00. OPERATIONS CHECK GOOD.SDR YENA2020121700602Battery · no testFLT 1056, PLS-JFK. BATTERY CAPACITY TEST REQUIRED, PER TC A20 33-31-710-003. R & R EPSU BATTERY, IAW AMM 33-51-00. OPERATIONS CHECK GOOD.SDR YENA2020121700601Battery · no testFLT 1056, PLS-JFK. BATTERY CAPACITY TEST REQUIREDD EPSU BATTERY CHANGE. R & R EPSU BATTERY, IAW AMM 33-31-00 AND TC A320-33-51-00-710.SDR YENA2020121700600Power Supply · no testFLT 1210, JAX-BOS. SEVERAL INTERIOR CABIN EMERGENCY LIGHTS WILL NOT ILLUMINATE DURING TEST. R & R ELPU NR 2, REF AMM 33-50-01. OPERATIONS TEST GOOD.SDR IXXA20201216041Battery Pack · inoperativePOST LANDING: EMERGENCY EXIT SIGN AT 3R DOOR INOPERATIVE. REMOVED AND REPLACED POWER PACK BATTERY AT R3 DOOR, IAW B757 AMM 33-51-07. OPERATIONAL CHECK SATISFACTORY. NO ADDITIONAL DEFECTS NOTED. AIRCRAFT RELEASED TO SERVICE.SDR AALA202012149022Housing · brokenAIRCRAFT WAS NOT GROUNDED. ESCAPE PATH LIGHT AT SEAT 28C IS BROKEN AND DANGLING. REPLACED EMERGENCY LIGHT HOUSING, IAW AMM 33-51-00. OPERATIONS CHECK GOOD.SDR QXEA2020121400352Light · inoperativeF/A REPORT PHOTOLUMINESCENT STRIP ON LEFT SIDE 1A-2A NOT WORKING. REMOVED FROM SERVICE. R & R FWD PHOTOLUMINESCENT LT STRIP NEXT TO SEATS 1 & 2A, IAW E175 AMM 33-50-21-000/400-801-A. OPERATIONS CHECK NORMAL, NO FURTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SSDR SWAA2020121636345Lens · brokenPASSENGER CABIN RT AFT EMERGENCY EXIT LOWER EXIT SIGN LENS BROKEN. REPLACED PASSENGER CABIN RT AFT EMERGENCY EXIT LOWER EXIT SIGN LENS, IAW AMM 33-51-01-960-802 STEP 3C (10).SDR SWAA2020121636342Light · missingLOWER FWD OVERWING EMERGENCY EXIT LIGHT COVER OFF FO SIDE. R & R EXIT LIGHT ASSEMBLY, IN REF TO AMM 33-51-04.SDR WX0A2020121573619Power Supply · no testBATTERY ON EPSU 10WL FAILED EMERGENCY LIGHT TEST. REMOVED AND REPLACED EPSU BATTERY 10WL, IAW A319 AMM 33-51-38 PB 401. OPERATIONS CHECK GOOD.SDR WX0A2020121573617Power Supply · no testDURING CABIN EMERGENCY LIGHTING TEST BATTERY FIN (12WL) FAILED. REMOVED AND REPLACED BATTERY FIN (12WL), IAW AMM 33-51-38. BITE CHECK GOOD.SDR AALA202012149031Battery Pack · inoperativeAIRCRAFT IN BASE MAINTENANCE. EMERGENCY LIGHTS BETWEEN SEATS 26ABC AND 33ABC INOPERATIVE. REPLACED BATTERY PACK POWER SUPPLY M1672, IAW AMM 33-51-06-960-806 AND 33-31-00-710-801. OPERATIONS CHECK GOOD.SDR AALA202012149030Lamp · burned outAIRCRAFT IN BASE MAINTENANCE. R2 DOOR EXTERIOR SLIDE LIGHT INOPERATIVE. RELAMPED R2 DOOR EXTERIOR SLIDE LIGHT, IAW AMM 33-51-04-960-801. OPERATIONS CHECK GOOD.SDR AALA202012149015Battery · faultedAIRCRAFT WAS GROUNDED. WHILE ACCOMPLISHING JOB CARD 26L00025012 FOR DOOR L2 SLIDE REINSTALLATION, OPERATIONAL CHECK OF EMERGENCY POWER SUPPLY UNIT FAILED BUILT IN TEST EQUIPMENT CHECK WITH FOLLOWING FAILURES, ATA 33-51-38. EMERGENCY POWER SUPPLY UNIT BATTERYSDR AALA202012149014Battery · faultedAIRCRAFT WAS GROUNDED. WHILE ACCOMPLISHING JOB CARD 26L00025012 FOR DOOR L2 SLIDE RE INSTALLATION, OPERATIONAL CHECK OF EMERGENCY POWER SUPPLY UNIT FAILED BUILT IN TEST EQUIPMENT CHECK WITH FOLLOWING FAILURES, ATA 33-51-38. EMERGENCY POWER SUPPLY UNIT BATTERSDR AALA202012149013Bulb · inoperativeAIRCRAFT WAS GROUNDED. WHILE ACCOMPLISHING JOB CARD 26L00025012 FOR DOOR L2 SLIDE REINSTALLATION, OPERATIONAL CHECK OF EMERGENCY POWER SUPPLY UNIT FAILED BUILT IN TEST EQUIPMENT CHECK WITH FOLLOWING FAILURES, ATA 33-51-38. EMERGENCY POWER SUPPLY UNIT BATTERYSDR AALA202012139002Bulb · inoperativeAIRCRAFT WAS GROUNDED. WHILE ACCOMPLISHING JOB CARD 26L00025012 FOR DOOR L2 SLIDE RE-INSTALLATION, OPERATIONAL CHECK OF EMERGENCY POWER SUPPLY UNIT FAILED BUILT IN TEST EQUIPMENT CHECK WITH FOLLOWING FAILURES. ATA 33-51-38 EMERGENCY POWER SUPPLY UNIT BATTERYSDR IPXA2020121463384Switch · intermittentINSPECTION TYPE: N/A P5 OVERHEAD EMERGENCY SIGN ARM SWITCH INTERMITTENT. R & R EMERGENCY LIGHTS PANEL AND OPERATIONS CHECK OK, IAW AMM 33-51-08 ESR: IPC 31-12-11-66A-010.SDR IPXA2020121363320Light · inoperativeINSPECTION TYPE: N/A FOUND ON PS1 EMERGENCY LIGHT INOPERABLE. REPLACEMENT OF EMERGENCY LIGHT PERFORMED, IAW AMM 33-51-03 PB 201 REV 131.02.SDR DALA2020121404061Battery Pack · inoperativeTHE AFT TAIL COMP EMERGENCY WALKWAY LIGHTS ARE NOT WORKING. MAINTENANCE REPLACED THE BATTERY PACK AT B5-260 AT STA 1037L, IAW B717 AMM 33-51-03. OPERATIONAL CHECK WAS GOOD.SDR MASA2020121210650Light · inoperativeROW 9 CELING EMERG LIGHT INOPERABLE, PLACED ON MEL.SDR 2020FA0000532Battery Pack · no testDURING MAINTENANCE IT WAS FOUND THAT EPSU BATTERY FAILED OPERATIONAL TESTING. BATTERY WAS REMOVED FROM SERVICE.
Back to JASC 3350