JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20201218019Light · intermittentMCD HINGE FAIRING EMERGENCY LIGHT HOUSING INTERMITTENT GROUND. R & R MCD EMERGENCY LIGHT ASSEMBLY. OPERATIONS CHECK SATISFACTORYSDR DXTA2020121804493Battery · dischargedEMERGENCY EXIT LIGHTS INOPERABLE WITH COLD AIRCRAFT. NO LIGHTS FUNCTION WITH EMERGENCY LIGHT SWITCH IN ARM. REMOVED ALL FOUR EMERGENCY LIGHT BATTERIES, INSTALLED THREE REPAIRED, AND ONE MODIFIED. CUSTOMER SUPPLIED EMEERGENCY LIGHT BATTERIES. PERFORMED DIRESDR DALA2020122104175Battery Pack · inoperativeDURING TEST THE EMERGENCY LIGHT BATTERY, LIGHT OFF BEFORE 15 MIN, IN REF AMDS 3350-7413. BATTERY PACK AND BATTERY CHARGER OF MID EMERGENCY EXIT LIGHTS SEAT ROW 17 C B A WERE REPLACED AND BATTERY PACK CAPACITY CHECK WAS PERFORMED, PER B737-800 AMM 33-51-06. OSDR DALA2020122104172Lens · looseEMERGENCY EXIT SIGN COVER LOOSE, LOCATIONS: 01. CORRECTIVE ACTION: RESECURED EXIT SIGN COVER AT 1R DOOR, OPERATIONS NORMAL.SDR SIMA20201218002Flashlight · inoperativeAFT CABIN EMERGENCY FLASHLIGHT INOPERABLE. C/A: DEFERRED AFT EMERGENCY FLASHLIGHT, PER MEL 25-53 M PROCEDURE C/W.SDR SIMA20201218001Light · inoperativeAFTER LANDING FA 1 REPORTS FIRST 3 STRIPS OF EMERGENCY LIGTING ARE NOT ILLUMINATING. C/A: R & R 2 PHOTOLUMINESCENT INDICATION STRIP LIGHT, IAW ERJ AMM 33-50-21. OPERATIONAL CHECK GOOD SEE AML PG 4691202 NR 3.SDR MASA2020121810657Sign · inoperativeGALLEY EMERGENCY EXIT SIGN INOPERABLE, PLACED ON MEL.SDR MASA2020121810655Light · inoperativeROW 18 CEILING EMER FLOOD LIGHT INOPERABLE, PLACED ON MEL.SDR AALA202012189003Power Supply · no testAIRCRAFT WAS NOT GROUNDED. FORWARD EMERGENCY POWER SUPPLY UNIT (10WL) WILL NOT TEST. REMOVED AND REPLACED FORWARD EMERGENCY POWER SUPPLY UNIT (10WL), PER AMM 33-51-38.SDR DALA2020121804144Charger · inoperativeMAINTENANCE FOUND LLCR EMERGENCY LIGHTS INOPERATIVE. LLCR BATTERY CHARGER REPLACED. SYSTEM OPERATION IS NORMAL.SDR SWAA2020122137545Light · inoperativeCA SIDE MID CABIN EMERGENCY EXIT LIGHT (ON OVERWING EXIT DOOR) WILL NOT ILLUMINATE (SIDEWALL LIGHT). R & R LT OVERWING EMERGENCY EXIT SIDEWALL LIGHT ASSEMBLY, IAW AMM 33-21-00. OPERATIONS CHECKS GOOD, CL # 62801.SDR DXTA2020121704487Battery Pack · dischargedEMERGENCY LIGHT SWITCH IN ARMED POSITION WITH BATTERY SWITCH OFF DOES NOT ILLUMINATE LIGHTING. REMOVED AND REPLACED NR 1 EMERGENCY LIGHTS BATTERY PACK, IAW CE 680A AMM 33-50-06. CHARGED UP ALL EMERGENCY LIGHTS BATTERY PACKS AND PERFORMED EMERGENCY LIGHTS OPESDR SIMA20201217001Bulb · inoperativeRT UPPER EMERGENCY EXIT LIGHT INOPERABLE. C/A: R & R RT UPPER EMERGENCY LIGHT BULB, IAW EMB 145 AMM 33-50-10. OPERATIONS CHECK GOOD. NO DEFECTS NOTED.SDR WX0A2020121873621Power Supply · no testEPSU 10WL FAILED EPSU SYS TEST. REMOVED & REPLACED EPSU 10WL BATTERY & OPERATIONS CHECK GOOD, IAW AMM 33-51-38.SDR UIEA2020121802595Power Supply · inoperativeEMERGENCY LIGHTS INOPERABLE ON RIGHT HAND SIDE OF A/C. REMOVED AND REPLACED POWER SUPPLY M733, IAW 33-51-00. EMERGENCY LIGHTS OPERATIONS CHECK NORMAL.SDR CALA2020121801400Light · inoperativeRIGHT FWD OVER WING EXIT, EXTERIOR EMERGENCY EGRESS LIGHT INOPERABLE. RELAMPER, REF AMM 33-51-04 ADD EMP: U166355.SDR FDEA201812063450Control Panel · inoperativeREMOVED EMERGENCY LIGHT PANEL FROM OVER L1 DOOR IAW AMM 25-23-23-5. REPAIRED SLIDE PANEL IAW AMM 20-20-03-2. PANEL READY FOR INSTALLATION. REINSTALLED EMRGENCY LIGHT PANEL IAW AMM 25-23-23.SDR U2RA2020121600007Battery · no testDURING EMERGENCY LIGHT BATTERY CAP TEST, BATTERY PACK AT LOCATION 13WL FAILED. REMOVED AND REPLACED BATTERY AT LOCATION 13WL PER A330 AMM 33-51-88 - OPS CHECK GOOD.SDR U2RA2020121600006Battery · no testDURING EMERGENCY LIGHT BATTERY CAP TEST, BATTERY PACK AT LOCATION 12WL FAILED. REMOVED AND REPLACED BATTERY AT LOCATION 12WL PER A330 AMM 33-51-88 - OPS CHECK GOOD.SDR U2RA2020121600005Battery · no testDURING EMERGENCY LIGHT BATTERY CAP TEST, BATTERY PACK AT LOCATION 16WL FAILED. REMOVED AND REPLACED BATTERY AT LOCATION 16WL PER A330 AMM 33-51-88 - OPS CHECK GOOD.SDR SWAA2021010737015Lens · brokenG-1 GALLEY EMERGENCY EXIT LIGHT LENS IS BROKEN. REPLACED G1 GALLEY EMERGENCY EXIT LIGHT LENS, IAW AMM-33-51-01-960-802 ATAG# WN4451.SDR DALA2021010600056Flashlight · inoperativeTHE EMERGENCY LIGHT BATTERY POWER SUPPLY IS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY LIGHT BATTERY POWER SUPPLY, REF B717 AMM 33-51-03.SDR YENA2020122100625Epsu · failedDURING HEAVY MAINTENANCE, INOPERABLE EPSU, EMERGENCY POWER SUPPLY UNIT 12WL IN PASSENGER CABIN. R & R EMERGENCY POWER SUPPLY UNIT EPSU FIN (12WL), IAW AMM 33-51-38-000-001-A AND AMM 33-51-38-400-001-A. PERFORMED OPERATIONAL CHECK OF THE EPSU, IAW AMM 33-51-0SDR YENA2020122100623Power Supply · no testDURING HEAVY MAINTENANCE, REF N/R 2020-359482 W/O 2020 160/1, INOPERABLE EPSU-EMERGENCY POWER SUPPLY UNIT 11WL IN PASSENGER CABIN. R & R EMERGENCY POWER SUPPLY UNIT EPSU FIN (11WL), IAW AMM 33-51-38-000-001-A AND AMM 33-51-38-400-001-A. PERFORMED OPERATIONAL SDR SWAA2020122137297Cover · loose'EXIT/SALIDA' LIGHT COVER NEAR FWD GALLEY DOOR POPPED OFF, WILL NOT STAY ON. INSTALLED NEW EXIT LIGHT COVER, PER AMM 33-51-02.SDR SWAA2020122137298Fuse · inoperativeTHE OVERWING EMERGENCY EXIT LIGHT INOPERABLE. INSPECTED AND FOUND LT OVERWING EMERGENCY EXIT SIDE WALL LIGHT IS OUT. REMOVED AND REPLACED FUSE FOR SIDE WALL LIGHT, IAW AMM 33-21-00. OPERATIONS CHECK GOOD AND ALSO EMERGENCY LIGHTS CHECKED OK. CL #63138 (CLOSDR SWAA2020122137301Lamp · inoperativeEMERGENCY EXIT LIGHTS AT THE FOLLOWING LOCATIONS ARE INOPERABLE: FWD CEILING PANEL; EXTERIOR LEFT HAND OVER-WING ESCAPE AND RT WING TRAILING EDGE GROUND ILLUMINATION. RELAMPED AND PERFORMED GOOD TEST OF EMERGENCY LIGHT IN FWD RT RECESSED CEILING LIGHT PANEL, SDR DALA2020121704140Power Supply · no testEPSU 19WL LOCATED IN RT CEILING BETWEEN FR 59-FR 60 FAILS BITE CHECK. CORRECTIVE ACTION: REMOVED AND REPLACED EPSU 19WL, PER A330 AMM 33-51.SDR SWAA2020121737107Circuit Breaker · openDURING PDSC FOUND CAB EMERGENCY LIGHT CB OPEN. CONTRCAT AMT: 3413604. RESET EMERGENCY LIGHT C/B. ALL OPERATIONS CHECK NORMAL, PER AMM 33-51-00, NO DEFECTS FOUND AT THIS TIME. OK FOR SERVICE. CNTRCT AMT: 3413604.SDR SWAA2020121737267Lens · looseEXIT LIGHT COVER NEAR R1 DOOR FELL OFF. REMOVED AND REPLACED R1 DOOR EMERGENCY EXIT LIGHT LENS, PER SIP.SDR SWAA2020121737081Lamp · inoperativeRT FUSELAGE EMERGENCY EXIT LIGHT INOPERABLE. RE-LAMPED RT AFT LOWER FUSEAGE EMERGENCY EXIT LIGHT, PER AMM 33-51-04. OPERATIONS CHECKS GOOD.SDR SWAA2020121737080Lamp · inoperativeLT FUSELAGE EMERGENCY EXIT LIGHT INOPERABLE. RE-LAMPED LT AFT LOWER FUSELAGE EMERGENCY EXIT LIGH LIGHT, PER AMM 33-51-04. OPERATIONS CHECKS GOOD.SDR DXTA2020121604473Battery Pack · dischargedPICKING UP AIRCRAFT DURING PRE-FLIGHT WHILE TESTING THE EMERGENCY LIGHTING SYSTEM. NONE OF THE EMERGENCY LIGHTS WORK. ALL FOUR BATTERY PACKS ARE DEAD. VERIFIED EMERGENCY LIGHTS WOULD NOT COME ON WITH BATTERY IN OFF POSITION. POWERED AIRCRAFT WITH APU. VERSDR DXTA2020121604480Light · no testPREFLIGHT TEST OF EMERGENCY LIGHTS FAILED. WITH THE EMERGENCY LIGHTS SWITCH IN ARM WITH BATTERIES OFF, NO EMERGENCY LIGHTS ARE ILLUMINATED. SIGNOFF. PERFORMED OPERATIONS CHECK OF EMERGENCY LIGHTING, OPERATIONS CHECKS GOOD, EMERGENCY LIGHTS WORK PER AMM. NOSDR DALA2020121704128Battery Pack · inoperativeDURING INSPECTION FOUND AFT RT SECTION OF EMERGENCY LIGHTS INOPERATIVE. R & R BATTERY PACK AT LOCATION M1672, PER B737 AMM 33-51. OPERATIONS CHECK OK.SDR I5EA2020121600005Battery Pack · dischargedPOWER SUPPLY FOR EMERGENCY LIGHT M1435 STA 727G (R) INOPERABLE. REMOVED AND REPLACED BATTERY PACK AT M1435 STA 727G (R). OPERATIONS CHECK GOOD, IAW B737-400 AMM 33-51-51.SDR I5EA2020121600004Power Supply · inoperativePOWER SUPPLY FOR EMERGENCY LIGHT M1136 STA 753L IS NOT CHARGING. REMOVED AND REPLACED POWER SUPPLY FOR EMERGENCY LIGHT M1136 AT STA 753L. OPERATIONS CHECK GOOD, IAW B737-400 AMM 33-51-51.SDR IPXA2020121663467Sign · malfunctionedINSPECTION TYPE: N/A EXIT SIGN DOES NOT ILLUMINATE WITH SWITCH IN THE ON POSITION. IT DOES ILLUMINATE WITH THE GEAR DOWN IN AUTO. PERFORMED EXIT DOOR LIGHT OPERATIONS CHECK, REF AMM 33-51-13. OPERATIONS CHECK GOOD.SDR WX0A2020121673620Power Supply · no testEPSU BATTERIES 10WL, 11WL, 12WL FAILED CABIN EMERGENCY LIGHTING CAPACITANCE TEST. REPLACED ALL 3 EPSU BATTERIES 10WL, 11WL, 12WL W/REF TO AMM 33-51-38 PB 401. OPERATIONS CHECK GOOD. OK FOR SERVICE.SDR SWAA2021011136933Lens · damagedRT NR 2 BIN EMERGENCY LIGHT LENS IS DAMAGED. INSTALLED A NEW RT NR 2 BIN EMERGENCY LIGHT LENS, PER AMM NR 33-51-03-960-801 STEP 2D ITEMS (1)(A)(C) 2666C 17DEC20.SDR YENA2020122100614Battery · no testDURING RETURN TO SERVICE CHECK, EPSU BATTERY AT 15WL FAILED TEST. REMOVED AND REPLACED EPSU BATT (15WL) L2 DOOR, IAW AMM 33-51-38. OPERATIONS CHECK GOOD.SDR YENA2020122100613Battery · no testDURING RETURN TO SERVICE CHECK, EPSU BATTERY AT 14WL FAILED TEST. REMOVED AND REPLACED EPSU BATT (14WL) R2 DOOR, IAW AMM 33-51-38. OPERATIONS CHECK GOOD.SDR YENA2020122100612Battery · failedDURING RETURN TO SERVICE CHECK, EPSU BATTERY AT 12WL FAILED TEST. REMOVED AND REPLACED EPSU BATT (12WL) R3 DOOR, IAW AMM 33-51-38. OPERATIONS CHECK GOOD.SDR YENA2020122100611Battery · failedDURING RETURN TO SERVICE CHECK, EPSU BATTERY AT 11WL FAILED TEST. REMOVED AND REPLACED EPSU BATT L3 (11WL) DOOR, IAW AMM 33-51-38. OPERATIONS CHECK GOOD.SDR R61A2020121800907Battery Pack · inoperativeFLIGHT CREW REPORTED THE EMERGENCY LIGHT AT ROW 5 WAS INOPERATIVE. MAINTENANCE REPLACED THE NR 2 EMERGENCY LIGHT BATTERY PACK IN ACCORDANCE WITH AMM 33-50-01, WITH NO FURTHER DEFECTS NOTED.SDR REXA2020121700837Battery Pack · inoperativeCEILING MOUNTED "EXIT" SIGN LIGHTS INOPERABLE. REMOVED AND REPLACED BATTERY PACK FOR CEILING MOUNTED EXIT LIGHT SIGN, IAW CRJ-200 AMM 33-51-04. OPERATIONS CHECK GOOD. P/N OFF 2013-1A P/N ON 2013-1ASMI S/N ON 10046 S/N OFF 102558.SDR SWAA2020121736618Battery Pack · inoperativeSEVERAL FWD & AFT EMERGENCY LIGHTS ARE INOPERABLE. DUE TO LTP SEVERAL EMERGENCY LIGHTS INOPERABLE. CHARGED EMERGENCY LIGHT BATTERY PACKS AND FOUND ALL EMERGENCY LIGHT TO OPERATIONS GOOD, REF AMM 33-51-00.SDR SWAA2020121736832Lamp · inoperativeLT AFT EMERGENCY LIGHT ON BELLY OF AIRCRAFT INOPERABLE. RELAMPED LT AFT EMERGENCY LIGHT, PER AMM 33-51-04.SDR REXA2020121600836Battery Pack · inoperativeON PREFLIGHT EMERGENCY LIGHTS IN ROW 13 DO NOT WORK-SIDE WALL & OVERHEAD LIGHTS. R & R NR 2 BATTERY PACK, IAW CRJ 900 AMM 33-51-17. OPERATIONS CHECK GOOD NO FURTHER DEFECTS NOTED.SDR SWAA2020121636605Battery Pack · inoperativeFOUND BOTH OVERWING ESCAPE EMERGENCY LIGHTS INOPERABLE. R & R BATTERY PACK M1670 AT STATION 727C+13 611212 LBL 68, PER AMM 33-51-06. OPERATIONS CHECK GOOD.
Back to JASC 3350