SDR CALA2020091501106Battery Pack · dischargedEMERGENCY LIGHTS OUT AT L4 LOCATION REPLACED 1EA BATTERY PACK AT L4 LOCATION, REF 777 MM 33-51-06-960-802.SDR CALA2020091501105Battery Pack · dischargedEMERGENCY LIGHTS OUT AT R1 REPLACED ONE EA. BATTERY PACK AT R1 LOCATION, REF 777 MM 33-51-06-960-802.SDR CALA2020091501104Battery Pack · dischargedEMERGENCY LIGHTS OUT AT L2 LOCATION REPLACED 2EA BATTERY PACKS AT L2 LOCATION, REF 777 MM 33-51-06-960-802.SDR CALA2020091501103Battery Pack · dischargedEMERGENCY LIGHTS OUT AT L3 LOCATION REPLACED 3EA BATTERY PACKS AT L3 LOCATION, REF 777 MM 33-51-06-960-802.SDR CALA2020091501102Battery Pack · dischargedEMERGENCY LIGHTS IN UPPER CABIN AT ROW 29 & 34 INOP. REPLACED BATTERY PACK LOCATED ON CEILING PANEL AT 31 DEF, AS PER AMM 33-51-06-960-805. LIGHTS CHECK GOOD. LOG CLEARED.SDR IPXA2020091546202Warning Message · false activationINSPECTION TYPE: NA DURING PREFLIGHT EMERGENCY LIGHTS EICAS ILLUMINATED. C/W SYS OPS & TEST NORMAL, I/A/W MM 33-51-04-000.SDR AALA202009159010Cover · missingAIRCRAFT WAS NOT GROUNDED: CABIN CREW FOUND EXIT SIGN COVER MISSING WITH EXPOSED WIRES, COVER FOUND ON A/C. REPLACED SIGN COVER.SDR DALA2020091503072Battery Pack · inoperativeSHIP 6822, DURING INSPECTION FOUND EMERGENCY SEAT LIGHTS FROM ROW 27 DEF-31 DEF INOPERATIVE. CORRECTIVE ACTION: REPLACED BATTERY M1383 AND CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA2020091503071Light · inoperativeSHIP 6715, DURING SERVICE CHECK FOUND FLIGHT DECK EMERGENCY LIGHTS INOPERATIVE. CORRECTIVE ACTION: EMERGENCY LIGHTS REPLACED.SDR DALA2020091503070Battery Pack · inoperativeSHIP 6822, DURING INSPECTION FOUND EMERGENCY OVERHEAD LIGHT AT ROW 30/31 DEF INOPERATIVE. CORRECTIVE ACTION: REPLACED BATTERY M11383 AND CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA2020091403052Battery Pack · inoperativeTHE EXIT SIGN ABOVE THE FORWARD F/A SEAT IS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AT B-5-235, PER B717 AMM 33-51. OPERATIONAL CHECK IS NORMAL.SDR SWAA2020091715804Cover · missingCEILING MOUNTED EMERGENCY EXIT SIGN AT ROW 15 MISSING ACCESS COVER PLATE, REF IPC 33-51-01-50K NR 125 (NEF ITEMS LISTED IN MEL APPENDIX 25-10 NON-ESSENTIAL EQUIPMENT & FURNISHINGS). REPLACED MISSING SIGN CAP, REF SIPCL NR 80030 (DMA 0487982).SDR DALA2020091503081Light · damagedSHIP 3069 EMERGENCY LIGHT AT 15C DAMAGED. CORRECTIVE ACTION: RE-SECURED LIGHT ASSEMBLY. REPLACED EMERGENCY LIGHT COVER AT 15C, PER AMM 33-50, REMOVED PLACARD (7085154).SDR DALA2020091503080Light · damagedSHIP 3002 EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE, LOCATIONS: 29C. CORRECTIVE ACTION: R & R EMERGENCY LIGHT ASSY ON SEAT 29C, PER A321 CMM 25-52, CKS NML (1613726).SDR DALA2020091543074Battery Pack · inoperativeDURING INSPECTION FOUND CEILING EMERGENCY LIGHT AT 30ABC IS INOPERATIVE. REMOVED AND REPLACED LIGHT ASSY NO HELP. REMOVED AND REPLACED EMC BAT PACK ABOVE ROW 29ABC, LIGHT AT 30ABC. OPS CHECKS OK, REF B737 AMM 33-51.SDR DALA2020091543073Connector · looseDURING INSPECTION FOUND ROW 33 SEAT MOUNTED PROXIMITY LIGHT INOPERATIVE. T/S IAW B737 WDM 33-51-14 FOUND CONNECTOR LOOSE, RESECURED. OPS CHECKS GOOD.SDR CALA2020091501101Battery Pack · dischargedEMERGENCY EXIT LIGHTS AT RIGHT OVERWING EXIT DOOR INOP. REPLACE BATTERY PACK AT M 1695, PER AMM 33-51-06-960-805. OPS CHECKS GOOD.SDR SWAA2020091515781Light · inoperativeEMERGENCY EXIT LIGHT AFT OF RT AFT SERVICE DOOR INOPERABLE. RELAMPED EMERGENCY LIGHT AFT OF RT AFT SERVICE DOOR, PER AMM 33-51-04.SDR AALA2020091549004Circuit Breaker · trippedAIRCRAFT WAS NOT GROUNDED: FOUND CABIN EMERGENCY LIGHT CIRCUIT BREAKER POPPED DURING PREFLIGHT. RESET CIRCUIT BREAKER AND SYSTEM OPERATIONS CHECKS NORMAL, PER AMM 33-51-00.SDR AALA2020091549002Power Supply · no testAIRCRAFT IN BASE MAINTENANCE, EMERGENCY LIGHT BITE CHECK. FAULT: EPSU BATTERY AFT LT. REMOVED AND REPLACED LEFT AFT EPSU (EMERGENCY POWER SUPPLY UNIT) 13WL, PER AMM 33-51-38. OPERATIONAL CHECK GOOD.SDR AALA2020091539006Lens · missingAIRCRAFT NOT GROUNDED, EMERGENCY LIGHT LENS MISSING, SEAT ROW 20ABC. REPLACED EMERGENCY LIGHT LENS, PER AMM 33-51-19. OPERATIONAL CHECK OKAY.SDR ASAA2020091433175Battery Pack · dischargedAFT EMERGENCY EXIT LIGHTS OUT, GALLEY & CABIN SECTION. GROUNDED - YES. R & R EMERG BATT PACK LOCATION, REF B737-900 AMM 33-51-06. OPS CHECK GOOD.SDR WX0A2020091473573Epsu · no testAFT EPSU BATTERY (13WL) FAILED OPS TEST OF CABIN EMERGENCY LIGHTS. REPLACED AFT EPSU (13WL) IAW AMM 33-51-38 PB 401, OPS CHECK GOOD.SDR DALA2020091403051Battery Pack · inoperativeTHE EMERGENCY LIGHTS LOWER FLOOR SECOND ROW OVERWING ARE INOPERATIVE. MAINTENANCE REPLACED THE OVERWING EMERGENCY LIGHT BATTERY PACK, PER B717 AMM 33-55. OPERATIONAL CHECK WAS GOOD.SDR ASOA202009124023SLight · inoperativeMAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT ASSEMBLY FOR SEATS 19A-21A. OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR DALA2020091543076Light · damagedDURING INSPECTION FOUND EMERGENCY SEAT MOUNTED LIGHTING DAMAGED, INOPERATIVE. ADJUSTED AND SECURED 32D EMERGENCY LIGHT, CK GOOD.SDR AALA2020091539019Power Supply · inoperativeAIRCRAFT WAS GROUNDED (SHORT TERM STORAGE): 3L DOOR EMERGENCY LIGHT POWER SUPPLY UNIT M33406 FAILED TEST. REMOVED AND REPLACED M33406 EMERGENCY LIGHT POWER SUPPLY AT DOOR 3L, IAW AMM 33-51-06 AND TEST GOOD.SDR AALA2020091539009Power Supply · no testAIRCRAFT NOT GROUNDED, EMERGENCY LIGHTS FAILED OPERATIONAL TEST. FAULTS: "EPSU INT LOAD EMER R" AND "EPSU INT LOAD EMER L". REPLACED EPSU (EMERGENCY POWER SUPPLY UNIT) BATTERIES, LEFT EPSU 11WL (AALA202009139009) AND RIGHT EPSU 12WL (AALA202009139008), PER ASDR AALA2020091539008Power Supply · no testAIRCRAFT NOT GROUNDED, EMERGENCY LIGHTS FAILED OPERATIONAL TEST. FAULTS: "EPSU INT LOAD EMER R" AND "EPSU INT LOAD EMER L". REPLACED EPSU (EMERGENCY POWER SUPPLY UNIT) BATTERIES, LEFT EPSU 11WL (AALA202009139009) AND RIGHT EPSU 12WL (AALA202009139008), PER ASDR F3LA2020091400037Slide · no testDISCREPANCY: L1 DOOR SLIDE FAILED EPSU TEST. DURING OVERNIGHT MAINTENANCE. CORRECTIVE ACTION: REPLACED L1 DOOR SLIDE, REF AMM 25-62-44-000-012-A AND 25-62-44-400-007-A. OPS CHECKS GOOD AT THIS TIME.SDR DALA2020091403061Charger · inoperativeDURING THE SERVICE CHECK, MAINTENANCE FOUND SEAT ROW 33-37 EMERGENCY PATH LIGHTING TO BE INOPERATIVE. REPLACED THE BATTERY CHARGER M11648 AND OPERATIONAL CHECK WAS GOOD. OK FOR SERVICE.SDR QXEA2020091400279Lamp · inoperativeFWD OVERHEAD EMERGENCY EXIT LIGHT IS INOP. REMOVED FROM SERVICE. RELAMPED OCCUPIED PORTION OF FWD INFORMATION SIGN. OPS CHECK GOOD, A/C OK FOR RETURN TO SERVICE. AIRCRAFT RETURNED TO SERVICE.SDR FDEA2020091422189Lamp · inoperativeLT FUSELAGE EMERGENCY ESCAPE LIGHT BY L1 DOOR INOP. RELAMPED, REF AMM 33-51-06-2-1. GOOD FOR SERVICE.SDR SIMA202009132002Battery Pack · inoperativeEMERGENCY BATTERY NR 3 INOPERABLE. C/A REMOVED AND REPLACED NR 3 EMERGENCY BATTERY AND CHARGER ASSEMBLY, IAW AMM 33-50-04. OPERATIONAL CHECK GOOD.SDR SIMA202009132001Light · inoperativeDURING PS-1 FOUND LT EXTERNAL EMERGENCY LIGHT ABOVE WING INOP. C/A-R & R LT EXTERNAL EMERGENCY LIGHT ABOVE WING, IAW EMB 145 AMM 33-50-10.SDR MASA2020091210571Light · inoperativeROW 8 CEILING EMERGENCY FLOOD LT INOPERABLE. PLACED ON MEL.SDR SWAA2020092418038Battery Pack · inoperativeROW 6DEF EMERGENCY LIGHT INOP. REMOVED AND REPLACED BATTERY PACK LOCATION M1674. OPS CHECKS GOOD, PER MM 33-51-06.SDR DALA2020091543079Light · inoperativeSHIP 3023 DURING SERVICE CHECK FOUND EMERGENCY ESCAPE PATH LIGHT INOPERATIVE AT SEAT LOCATION 12C. CORRECTIVE ACTION: REMOVED AND REPLACED EMERGENCY LIGHT ASSY AT SEAT 12C. OPS CKS GOOD, PER A321 AMM 33-51 (6648872).SDR DALA2020091543077Light · damagedDURING INSPECTION FOUND EMERGENCY SEAT MOUNTED LIGHTING DAMAGED, INOPERATIVE. R & R BOTH RED AND WHITE EMERGENCY LIGHTS ON AFT RT LAV WALL, OPS CKS GOOD, REF B737 AMM 33-51.SDR WX0A2020091473572Epsu · no testEPSU 11WL FAULT DURING WEEKLY CHECK. C/W TSM 33-51-00-810-855-A. REMOVED AND REPLACED 11WL EPSU BATTERY, AS PER A319 AMM 33-51-38 PB401. OPS CHECKS GOOD, FAULT CLEARED.SDR AALA2020091429005Housing · brokenAIRCRAFT WAS NOT GROUNDED: EXIT PATH LIGHTING ROWS 13C, 15C BROKEN OFF. RESECURED EMERGENCY LIGHTS HOUSING 13C & 15C, PER AMM 33-51-11.SDR AALA2020091429002Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT TEST ON CHECK FAILED. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT BATTERY, PER AMM 33-51-38. OPS CHECK GOOD.SDR J7SA2020091400220Battery Pack · dischargedDISCOVERED EMERGENCY LIGHTS REMAIN ON IN ARMED POSITION. REMOVED EMERGENCY BATTERY PACK 1 & 2 PN: 6450LS-00, PACK 1 SN 001745 PACK 2 SN 002188. INSTALLED INSPECTED BATTERY PACKS PN 6450LS-00, PACK 1 SN 002219 PACK 2 SN 002220. OPERATIONAL CHECK GOOD, IAW AMSDR AALA2020091439010Battery · inoperativeAIRCRAFT NOT GROUNDED-FORWARD GALLEY EMERGENCY LIGHTS INOPERABLE. REPLACED BATTERY EPSU 10WL, PER AMM 33-51-38, OPERATIONAL CHECK GOOD.SDR AALA2020091439007Power Supply · warning messageAIRCRAFT IN BASE MAINTENANCE-EMERGENCY LIGHTS INOPERABLE, SEATS 1, 2, 5, 9, 10, 14, 15, "UNIT FAULT" INDICATION. REPLACED L1 EPSU 10WL, PER AMM 33-51-38, OPERATIONAL CHECK GOOD.SDR SIMA202009131001Bulb · inoperativeRT EXTERIOR LOWER EMERGENCY LIGHT INOP. C/A-R & R RT LOWER EXTERIOR EMERGENGY LIGHT BULB. OPS CHECK GOOD, IAW AMM 33-50-10.SDR SIMA202009131002Battery Pack · inoperativeFRONT HALF FLOOR EMERGENCY LIGHTS INOP. C/A-RAR EMERGENCY LIGHTING BATTERY ASSY AND CHARGER 1 AND 2, IAW W/C 33-700-19. PERFORMED OPC OF EMERGENCY LIGHT SYSTEM. OPC GOOD, IAW W/C 33-700-17.SDR WX0A2020091173570Power Supply · no testEPSU BITE TEST SHOWS 13WL FAILS. FOUND EPSU BATT FAILED AT 13WL. REMOVED AND REPLACED BATT PACK AND OPS CK GOOD, BITE TEST GOOD. REF AMM 33-51-38 PB 401.SDR DALA2020091103036Battery Pack · inoperativeDURING SERVICE CHECK FOUND R4 DOOR EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK M33407. SYSTEM OPERATION IS NORMAL.SDR AALA202010289006Control Unit · no testAIRCRAFT WAS GROUNDED. REPORTS OF EMERGENCY LIGHTING WELLS BATTERY UNITS 30 AND 23 NOT REPORTING ON THE CONFIGURATION PAGE. REPLACED WIRELESS CONTROL UNIT (AALA202010279025) AND BATTERY (AALA202010289005) AT NR 30. REPLACED WIRELESS CONTROL UNIT (AALA202010
Back to JASC 3350