What was found
EPSU BITE TEST SHOWS 13WL FAILS. FOUND EPSU BATT FAILED AT 13WL. REMOVED AND REPLACED BATT PACK AND OPS CK GOOD, BITE TEST GOOD. REF AMM 33-51-38 PB 401.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EPSU BITE TEST SHOWS 13WL FAILS. FOUND EPSU BATT FAILED AT 13WL. REMOVED AND REPLACED BATT PACK AND OPS CK GOOD, BITE TEST GOOD. REF AMM 33-51-38 PB 401.