JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020072001109Cover · detachedFWD SERVICE DOOR EXIT SIGN DETACHED. REINSTALLED THE EXIT SIGN COVER PER S.I.PSDR SWAA2020072001119Light · looseOVERWING EXIT LIGHT IN CENTER OF CEILING IS LOOSE. TORQUED THE FASTENER IAW SIP & MM 33-51-04.SDR AALA2020072079015Light · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT MOST CEILING EMERGENCY LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY IAW AMM 33-51-11. OPERATIONAL CHECK GOOD.SDR AALA2020072079003Battery Pack · inoperativeAIRCRAFT WAS GROUNDED (SHORT TERM STORAGE): R3 DOOR EMERGENCY LIGHT BATTERY PACK (M33404) INOPERATIVE. REPLACED BATTERY PACK PER AMM 33-51-06-960-802. OPERATIONAL TEST GOOD PER AMM 33-51-06-710-002.SDR AALA2020072079002Battery Pack · inoperativeAIRCRAFT WAS GROUNDED (SHORT TERM STORAGE): R4 DOOR EMERGENCY LIGHT BATTERY PACK (M33408) INOPERATIVE. REPLACED BATTERY PACK PER AMM 33-51-06-960-802. OPERATIONAL TEST GOOD PER AMM 33-51-06-710-002.SDR AALA2020072079001Battery Pack · inoperativeAIRCRAFT WAS GROUNDED (SHORT TERM STORAGE): R4 DOOR EMERGENCY LIGHT BATTERY PACK (M33409) INOPERATIVE. REPLACED BATTERY PACK PER AMM 33-51-06-960-803. OPERATIONAL TEST GOOD PER AMM 33-51-06-710-002.SDR CALA2020072001059Battery Pack · no testRIGHT OVERWING INSIDE AND OUTSIDE EMERGENCY LIGHTS INOPERATIVE. CHARGED THE BATTERY PACKS IAW MM 33-51-06, ALL RT EMERGENCY LIGHT CHECKED GOOD. LT ROW 23-29ABC SEAT MOUNTED EMERGENCY LIGHT ROW 12 & 21ABC OVERHEAD BIN BULLNOSE EMERGENCY LIGHT FAILED CAPACITY CSDR REXA2020072000603Battery · inoperativeFWD SERVICE DOOR EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-15, OPS FAILED. R & R THE PS35 BATTERY ASSY AND BATTERY CHARGER ASSY IAW AMM 33-51-17, OPS TESTED GOOD.SDR REXA2020072000601Battery Pack · inoperativeEMERGENCY CEILING LIGHT DS4LY INOPERATIVE. REPLACED PS1LF BATTERY ASSY IAW AMM 33-51-04. PN OFF 2013-1A. SN OFF 119527. PN ON 2013-1ASMI. SN ON 12497. MINIMUM CHARGE TIME OF 6 HOURS WAS ACCOMPLISED PER CMM 25-60-03. DS4LY CEILING LIGHT OPS CHECKS GOOD IAW CRJSDR AALA2020071879017Battery Pack · dischargedAIRCRAFT NOT GROUNDED - EMERGENCY LIGHTS INOP, EPSU (EMERGENCY POWER SUPPLY UNIT) BATTERY PACKS DISCHARGED. REMOVED AND REPLACED EPSU BATTERY PACK, 10WL (AALA202007179014) AND 13WL (AALA202007179017) PER AMM 33-51-38, EPSU TEST CHECKS GOOD.SDR AALA2020071879014Battery Pack · dischargedAIRCRAFT NOT GROUNDED - EMERGENCY LIGHTS INOP, EPSU (EMERGENCY POWER SUPPLY UNIT) BATTERY PACKS DISCHARGED. REMOVED AND REPLACED EPSU BATTERY PACK, 10WL (AALA202007179014) AND 13WL (AALA202007179017) PER AMM 33-51-38, EPSU TEST CHECKS GOOD.SDR AALA2020071879009Power Supply · no testAIRCRAFT NOT GROUNDED - EMERGENCY LIGHTS SYSTEM TEST, AFT EMERGENCY BATTERY BAD. REMOVED AND REPLACED AFT EMERGENCY POWER SUPPLY UNIT (EPSU) PER AMM 33-51-38, OPERATIONAL CHECK GOOD.SDR UIEA2020071761560Lamp · inoperativeLEFT SIDE, ONE EXTERNAL EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-00, OPS CHECKED OK.SDR I5EA2020071600003Light · inoperativeRT AISLE EMERGENCY LIGHT INOP AT STA 500E.SDR SWAA2020072900900Lens · damagedEMERGENCY EXIT LIGHT LENS ON AFT GALLEY DAMAGED. REMOVED; REPLACED AND PERFORMED GOOD OPS TEST OF EMERGENCY EXIT LIGHT PER AMM 33-51-01-960-802SDR AALA2020072069016Power Supply · unserviceableAIRCRAFT IN BASE MAINTENANCE, BATTERY DISCHARGED, R1 DOOR EPSU (EMERGENCY POWER SUPPLY UNIT), M33094. REMOVED AND REPLACED EPSU M33094 PER AMM 33-51-06, OPERATIONAL CHECK GOOD.SDR AALA2020072069015Power Supply · unserviceableAIRCRAFT IN BASE MAINTENANCE, BATTERY DISCHARGED, R3 DOOR EPSU (EMERGENCY POWER SUPPLY UNIT), M33404. REMOVED AND REPLACED EPSU M33404 PER AMM 33-51-06, OPERATIONAL CHECK GOOD.SDR AALA2020072069014Power Supply · unserviceableAIRCRAFT IN BASE MAINTENANCE - BATTERY DISCHARGED, R3 DOOR EPSU (EMERGENCY POWER SUPPLY UNIT), M33401. REMOVED AND REPLACED EPSU M33401 PER AMM 33-51-06, OPERATIONAL CHECK GOOD.SDR ASAA2020072052910Power Supply · inoperativeRIGHT EMERGENCY LIGHT AISLE LIGHTS ROW 4-10 INOPERATIVE. GROUNDED - YES. REMOVED AND REPLACED EMERGENCY POWER SUPPLY WITH BATTERY IAW B737-800 AMM 33-51-06-960-806. OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME.SDR DALA2020072072612Battery Pack · no testDURING INSPECTION FOUND EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED 3 BATTERY PACKS AT LOCATIONS 11/12 A, AFT GALLEY IN CEILING PANEL PER B737 AMM 33-51. OPS CHECKS OK.SDR DALA2020072062607Battery Pack · inoperativeDURING INSPECTION FOUND EMERGENCY LIGHTS AT SEAT 23 AND AFT ARE INOPERATIVE. REPLACED BATTERY PACK AT LOCATION M1672. OPS NML PER B737 AMM 33-51.SDR AALA2020072079011Connector · unsecureAIRCRAFT NOT GROUNDED, EMERGENCY EXIT ROW SEAT LIGHTS, 18C & 19C, WERE INOPERATIVE. SECURED LOOSE CONNECTOR AT SEAT 19C, OPERATIONAL CHECKED NORMAL IAW AMM 33-51-19.SDR REXA2020072000600Battery Pack · inoperativeCREW REPORTED ALL EMERGENCY LIGHTS INOPERATIVE. R & R 4 EMERGENCY LIGHT BATTERY PACKS IAW AMM 33-51-04. OPS CHECKED GOOD.SDR DALA2020071902604Battery · no testDURING SERVICE CHECK, FOUND AFT L (13WL) EPCU BATTERY FAILED, REPLACED AFT L(13WL) BATTERYSDR AALA2020071879016Light · brokenAIRCRAFT NOT GROUNDED - R1 EXIT LIGHT BROKEN. REMOVED AND REPLACED EXIT LIGHT ASSEMBLY, PER AMM 33-51-16, OPERATIONAL CHECK NORMAL, OKAY FOR SERVICE.SDR AALA2020071879007Light · shortedAIRCRAFT IN BASE MAINTENANCE - EMERGENCY LIGHTS FAILED TEST, EPSU 10WL (REPEAT ITEM). REPLACED EPSU BATTERY ONLY, TEST FAILED DUE TO SHORT, EMERGENCY ESCAPE PATH LIGHT, SEAT ROW 5AC. REMOVED AND REPLACED 5AC EMERGENCY ESCAPE PATH LIGHT (AALA202007179007) PER SDR AALA2020071869007Power Supply · inoperativeAIRCRAFT IN BASE MAINTENANCE - EMERGENCY LIGHTS FAILED TEST, EPSU 10WL (REPEAT ITEM). REPLACED EPSU BATTERY ONLY, TEST FAILED DUE TO SHORT, EMERGENCY ESCAPE PATH LIGHT, SEAT ROW 5AC. REMOVED AND REPLACED 5AC EMERGENCY ESCAPE PATH LIGHT (AALA202007179007) PER SDR ASAA2020071752905Battery Pack · inoperativeL/H EMERGENCY AISLE LIGHTS ROW 4-16. GROUNDED - YES. REMOVED & REPLACED L/H EMERGENCY AISLE LIGHT BATTERY PACK IAW AMM. 33-51-06.SDR IPXA2020071755824Light · inoperativeEXTERIOR EMERGENCY EGRESS LIGHT WAS INOPERATIVE. REPLACED THE LAMPS FOR THE EXTERIOR EMERGENCY ESCAPE LIGHT IAW AMM 33 51 16. OPS CHECKED NORMAL.SDR IPXA2020071767834Power Supply · inoperativeEMRGENCY BATTERY PACK INOPERATIVE. R & R EMERGENCY POWER SUPPLY AMM 33-51-01-000-802, 33-51-01-400-802 AND 33-51-01-700-802.SDR DALA2020071762596Battery Pack · inoperativeL1-R1 DOOR EMERGENCY LIGHTS ARE INOPERATIVE. FOUND FUSE INOPERATIVE IN BATTERY PACK AND REPLACED THE SAME. SYSTEM OPERATION IS NORMAL.SDR DALA2020071762599Battery Pack · inoperativeEMERGENCY LIGHTS FROM ROWS 23DEF - 37DEF ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2020071762598Battery Pack · inoperativeOVERHEAD EMERGENCY LIGHTS FROM 25-30 ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2020071762597Battery Pack · inoperativeL1 DOOR EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR R61A2020071700569Fuse · blownTWO EMERGENCY LIGHTS NOT WORKING, ROW 1 AND 8. R&R FUSES 2 AND 4 IN ELPU 2.SDR SWAA2020071600660Lens · looseEMERGENCY EXIT LIGHT LENS IS LOOSE 4ABC. SECURED LOOSE EMERGENCY LIGHT LENS PER AMM 33-51-03.SDR 2DYA202007165001Light · inoperativeON VISUAL INSPECTION THE FLIGHT DECK EMERGENCY EXIT LIGHT WAS FOUND INOP. REMOVED AND REPLACED FLIGHT DECK EMERGENCY EXIT LIGHT ASSEMBLY IAW THE AMM 33-51-01. OPS CHECK GOOD.SDR AALA202007169001Epsu · unserviceableAIRCRAFT IN BASE MAINTENANCE - EPSU (EMERGENCY POWER SUPPLY UNIT) SYSTEM TEST, ERROR MESSAGE: BAT/EPSU (14WL) MID R. TROUBLESHOOTING PER TSM 33-51-00. REMOVED AND REPLACED EPSU 14WL PER AMM 33-58-00, OPERATIONAL CHECK GOOD.SDR MASA2020071510128Sign · inoperativeSERVICE DOOR LWR FWD FLOODLIGHT EXIT SIGN INOP.SDR SIMA20200715001Sign · inoperativeFWD EMERG EXIT SIGN AT 11 ABC INOP. REPLACED EMERG EXIT SIGN FWD AT SEAT 11 ABC OPERATION CHECK GOOD PER AMM 33-50-10.SDR WX0A2020071500001Switch · malfunctionedEMER EXIT LLT ILLUMINATED IN FLT, NO ASSOCIATED TRIGGER. FOLLOWED 33-51-00-810-881-A, REPLACED COCKPIT SW (4WL). PERFORMED BITE, AMM 33-51-00-710-001-A AND OPS CHECK, AMM 33-51-00-710-004-A. CHECKS PASS "OK". GOOD FOR SERVICE.SDR SWAA2020072000000Battery · no testEMERGENCY BATTERIES FAILED CAPACITY CHECK AT LOCTIONS M01669 AND M01672 / REMOVED AND REPLACED EMERGENCY BATTERIES AT LOCTIONS M01669 AND M01672 PER AMM 33-51-06SDR DALA2020071702601Battery Pack · inoperative(LOG 7125682) DURING INSPECTION FOUND EMERGENCY LIGHTS INOPERATIVE ON SEATS 18-21 AND EXIT SIGNS OVER THE RIGHT SIDE WING. R/R MID CABIN BATTERY PACK PER B737 AMM 33-51. OPS CK GOOD.SDR R61A2020071700567Fuse · blownAFT EXIT LOCATOR INOP. R&R FUSE F2 IN ELPU NR 3 IAW AMM 33-50-01.SDR SWAA2020071600134Sign · brokenCREW REPORTS EMERGENCY EXIT SIGN BROKEN AT RT OVERWING EXIT KICK PANEL. REPLACED LIGHT ASSY & OPS CHECK GOOD IAW MM 33-51-01.SDR AALA2020071659011Epsu · inoperativeAIRCRAFT IN BASE MAINTENANCE - EMERGENCY POWER SUPPLY UNIT 12WL INOP. REMOVED AND REPLACED EPSU (EMERGENCY POWER SUPPLY UNIT) 12WL PER AMM TASK 33-51-38-400. PERFORMED OPERATIONAL AND BITE CHECK PER AMM TASK 33-51-00-710-001-A, TEST OKAY.SDR SIMA202007154002Power Supply · inoperativeLT/RT OVERWING EMERGENCY LIGHTS INOP. R&R NR 4 EMERGENCY BATTERY POWER SUPPLY ASSY IAW AMM 33-50-04 OPS CHECK GOOD.SDR DALA2020071502592Battery Pack · dischargedDURING SVC CHECK FOUND EMERGENCY LIGHTS INOP BETWEEN ROWS 4-16,21 -32 & 38-42. T/S PER WDM 33-51. REMOVED & REPLACED BATTERY PACK & CHARGER M10568. REPLACED BATTERY PACKS M732 AND M735 PER AMM 33-51. EMERGENCY LIGHTS NOW TEST NORMAL.SDR IPXA2020071557813Battery · low voltageINSPECTION TYPE:N/A EMERGENCY LIGHT BAT LOW. R&R EMERGENCY BATTERY IAW MM 33-50-00 & IPC 33-51-00 SYSTEM OPS CHECKS NORMAL. ESR: MM 33-50-00 & IPC 33-51-00.SDR AALA202007159022Battery Pack · failedAIRCRAFT IN BASE MAINTENANCE - EMERGENCY LIGHTS, CIDS (CABIN INTERCOMMUNICATION DATA SYSTEM) 1 EPSU SYTEM TEST, BATTERIES FAILED, SEAT PATH LIGHTS 1, 2, 5, 9, 10, 14, 15 INOP. REMOVED AND REPLACED EPSU 10WL (AALA202007159006), AND REPLACED EPSU BATTERY PACK 1
Back to JASC 3350