JASC 3350
Service difficulty reports · 225,886
Reports filed under 3350 · Emergency Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3350' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202007159021Battery Pack · failedAIRCRAFT IN BASE MAINTENANCE - EMERGENCY LIGHTS, CIDS (CABIN INTERCOMMUNICATION DATA SYSTEM) 1 EPSU SYTEM TEST, BATTERIES FAILED, SEAT PATH LIGHTS 1, 2, 5, 9, 10, 14, 15 INOP. REMOVED AND REPLACED EPSU 10WL (AALA202007159006), AND REPLACED EPSU BATTERY PACK 1SDR AALA202007159020Battery Pack · failedAIRCRAFT IN BASE MAINTENANCE - EMERGENCY LIGHTS, CIDS (CABIN INTERCOMMUNICATION DATA SYSTEM) 1 EPSU SYTEM TEST, BATTERIES FAILED, SEAT PATH LIGHTS 1, 2, 5, 9, 10, 14, 15 INOP. REMOVED AND REPLACED EPSU 10WL (AALA202007159006), AND REPLACED EPSU BATTERY PACK 1SDR AALA202007159019Battery Pack · failedAIRCRAFT IN BASE MAINTENANCE - EMERGENCY LIGHTS, CIDS (CABIN INTERCOMMUNICATION DATA SYSTEM) 1 EPSU SYTEM TEST, BATTERIES FAILED, SEAT PATH LIGHTS 1, 2, 5, 9, 10, 14, 15 INOP. REMOVED AND REPLACED EPSU 10WL (AALA202007159006), AND REPLACED EPSU BATTERY PACK 1SDR AALA202007159016Power Supply · failedAIRCRAFT IN BASE MAINTENANCE - EMERGENCY LIGHTS, CIDS (CABIN INTERCOMMUNICATION DATA SYSTEM) 1 EPSU SYTEM TEST, BATTERIES FAILED, SEAT PATH LIGHTS 1, 2, 5, 9, 10, 14, 15 INOP. REMOVED AND REPLACED EPSU 10WL (AALA202007159006), AND REPLACED EPSU BATTERY PACK 1SDR AALA202007159012Battery · dischargedAIRCRAFT NOT GROUNDED - FORWARD FLIGHT ATTENDANT FLASHLIGHT INOP. FWD F/A FLASHLIGHT AUTHORIZED 14JUL2020T1335Z. REMOVED AND REPLACED FLASHLIGHT BATTERY, OPERATIONAL CHECK GOOD. CLEARED MEL.SDR DALA2020071402584Battery Pack · dischargedDURING INSPECTION FOUND EMERGENCY LIGHTS OUT ROWS 28-32 RT SIDE. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK IAW AMM 33-51. OP'S CHK GOOD.SDR WX0A2020072273528Switch · malfunctionedEMERGENCY EXIT LIGHT ILLUMINATED IN FLT - NO ASSOCIATED TRIGGER, FOLLOWED 33-51-00-810-881-A, REPLACED COCKPIT SWITCH (4WL). PERFORMED BITE, AMM 33-51-00-710-001-A AND OPS CHECK, AMM 33-51-00-710-004-A. CHECKS PASSED, GOOD FOR SERVICE.SDR WX0A2020072273527Sign · inoperativeDURING R2 DOOR LINING INSTALLATION FOUND UPPER EMERGENCY EXIT SIGN INOP. / REMOVED AND REPLACED R2 DOOR EXIT SIGN IAW AMM 33-51-16, OPS CHECK GOOD.SDR AALA2020072049022Power Supply · unserviceableAIRCRAFT IN BASE MAINTENANCE - BATTERY DISCHARGED, R2 DOOR EPSU (EMERGENCY POWER SUPPLY UNIT), M33098. REMOVED AND REPLACED EPSU M33098 PER AMM 33-51-06, OPERATIONAL CHECK GOOD.SDR AALA2020072049021Battery Pack · dischargedAIRCRAFT IN BASE MAINTENANCE - BATTERY DISCHARGED, R1 DOOR EPSU (EMERGENCY POWER SUPPLY UNIT), M33094. REMOVED AND REPLACED BATTERY PACK, EPSU M33094, PER AMM 33-51-06, OPERATIONAL CHECK GOOD.SDR AALA2020072049020Power Supply · unserviceableAIRCRAFT IN BASE MAINTENANCE, BATTERY DISCHARGED, L3 DOOR POWER SUPPLY M33400. REMOVED AND REPLACED THE EPSU IAW AMM 33-51-06, OPERATIONAL CHECKED GOOD.SDR AALA2020072049019Power Supply · inoperativeAIRCRAFT IN BASE MAINTENANCE - BATTERY DISCHARGED, L2 DOOR POWER SUPPLY M33099. REMOVED AND REPLACED THE EPSU IAW AMM 33-51-06, OPERATIONAL CHECKED GOOD.SDR AALA2020072049018Battery Pack · dischargedAIRCRAFT IN BASE MAINTENANCE, BATTERY DISCHARGED, L2 DOOR POWER SUPPLY M33096. REMOVED AND REPLACED THE BATTERY PACK, AND EPSU IAW AMM 33-51-06, OPERATIONAL CHECKED GOOD.SDR AALA2020072049017Battery Pack · dischargedAIRCRAFT IN BASE MAINTENANCE, BATTERY DISCHARGED, L1 DOOR POWER SUPPLY M33424. REMOVED AND REPLACED THE EPSU IAW AMM 33-51-06, OPERATIONAL CHECKED GOOD IAW AMM 33-51-06-960-803.SDR AALA2020072049016Power Supply · inoperativeAIRCRAFT IN BASE MAINTENANCE, BATTERY DISCHARGED, L1 DOOR EPSU M33093. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-51-06, OPS CHECKED GOOD IAW AMM TASK 33-51-06-960-803.SDR IXXA20200717024Charger · inoperativeINSPECTION-DAILY SCHEDULED MAINTENANCE FINDING: L3 DOOR EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AND BATTERY CHARGER IAW B767 AMM 33-51-00. OPERATIONAL CHECK SATISFACTORY. FAULT NOT DUPLICATED. AIRCRAFT RELEASED TO SERVICE.SDR IXXA20200717023Battery · inoperativeINSPECTION-DAILY SCHEDULED MAINTENANCE FINDING: L3 DOOR EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AND BATTERY CHARGER IAW B767 AMM 33-51-00. OPERATIONAL CHECK SATISFACTORY. FAULT NOT DUPLICATED. AIRCRAFT RELEASED TO SERVICE.SDR SWAA2020071600674Lens · missingEXIT PLASTIC PLACARD SIGN MISSING ON F/O SIDE FOR THE OVERWING EXIT. INSTALLED LIGHT ASSY LENS; PER MM 33-51-01; ALL GOOD.SDR DALA2020071502591Power Supply · inoperativeAFT RIGHT OVERWING EXIT IDENTIFIER, LOWER LIGHT NOT ILLUMINATING. REMOVED AND REPLACED BATTERY POWER SUPPLY M11384 PER AMM 33-51. LIGHTS TEST GOOD.SDR SWAA2020071500063Cover · brokenEXIT SIGN COVER AT OVERWING EXIT ON CAPTAIN'S SIDE IS BROKEN. REPLACED LENS COVER PER AMM 33-51-03.SDR SWAA2020071599826Light · inoperativeONE EXTERIOR EMERGENCY LIGHT AT AFT SERVICE DOOR INOP. (EXTERIOR EMER LIGHT SYS) RELAMP PER AMM 33-51-04. OPS CHECK GOOD.SDR SWAA2020071500057Light · inoperativeEMERGENCY LIGHT C/B POPPED ON P6-11 A9. RESET BREAKER IAW AMM 20-60-01 AND PERFORMED OPS TEST IAW AMM 33-51-15 FOUND ON LIGHT INOP SEE LOGPAGE 1328992 FOR MEL.SDR WX0A2020071500002Sign · inoperativeDURING R2 DOOR LINING INSTALLATION FOUND UPPER EMERGENCY EXIT SIGN INOP. REMOVED AND REPLACED R2 DOOR EXIT SIGN IAW AMM 33-51-16, OPS CHECK GOOD.SDR AALA2020071549025Light · inoperativeAIRCRAFT NOT GROUNDED, EMERGENCY LIGHTS FAILED OPERATIONAL TEST: ROW 16, 40D, 32J, AND L5 EXIT. REPAIRED EMERGENCY LIGHTS ROW 16 (AALA202007149003), 40D (AALA202007149023), 32J (AALA202007149024), AND L5 EXIT (AALA202007149025) PER AMM 25-25-04 AND 33-51-01, SDR AALA2020071549024Light · inoperativeAIRCRAFT NOT GROUNDED, EMERGENCY LIGHTS FAILED OPERATIONAL TEST: ROW 16, 40D, 32J, AND L5 EXIT. REPAIRED EMERGENCY LIGHTS ROW 16 (AALA202007149003), 40D (AALA202007149023), 32J (AALA202007149024), AND L5 EXIT (AALA202007149025) PER AMM 25-25-04 AND 33-51-01, SDR AALA2020071549023Light · inoperativeAIRCRAFT NOT GROUNDED, EMERGENCY LIGHTS FAILED OPERATIONAL TEST: ROW 16, 40D, 32J, AND L5 EXIT. REPAIRED EMERGENCY LIGHTS ROW 16 (AALA202007149003), 40D (AALA202007149023), 32J (AALA202007149024), AND L5 EXIT (AALA202007149025) PER AMM 25-25-04 AND 33-51-01, SDR AALA2020071549003Light · inoperativeAIRCRAFT NOT GROUNDED, EMERGENCY LIGHTS FAILED OPERATIONAL TEST: ROW 16, 40D, 32J, AND L5 EXIT. REPAIRED EMERGENCY LIGHTS ROW 16 (AALA202007149003), 40D (AALA202007149023), 32J (AALA202007149024), AND L5 EXIT (AALA202007149025) PER AMM 25-25-04 AND 33-51-01, SDR SIMA202007143002Light · inoperativeROW 12 CEILING EMERGENCY LIGHT INOP. R&R ROW 12 CEILING EMERGENCY LIGHT LAMP IAW AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPS CHECK GOOD.SDR FDEA202007131494Light · inoperativeDURING / AFTER EMERGENCY LIGHT TEST GOT "EMERG LT BAT 1 LO" ALERT. EMER LIGHTS - INOP. IDENTIFIED PARTS EMERG EXIT LIGHTS MPN: 60-4411-5 CPN: 3300197. PARTS(S) IDENTIFIED ARE THE MOST PROBABLE CAUSE. TROUBLESHOOTING IS REQUIRED PRIOR TO INSTALLING PART(SDR 2020F00333Battery Pack · dischargedDURING EMERGENCY LIGHT OPS CHECKS MULTIPLE LIGHTS FAILED TO COME ON. REMOVED AND REPLACED TWO BATTERY PACKS AT M736 AND M737 IAW AMM 33-51-07. REMOVED AND REPLACED 5 AMP FUSE IAW AMM 33-51-07. PERFORMED OPS CHECK OF EMERGENCY LIGHTS IAW 33-51-00 OPS CHECK GSDR 2020F00334Switch · faultyDURING EMERGENCY LIGHT OPS CHECKS MULTIPLE LIGHTS FAILED TO COME ON. REMOVED AND REPLACED TWO BATTERY PACKS AT M736 AND M737 IAW AMM 33-51-07. REMOVED AND REPLACED 5 AMP FUSE IAW AMM 33-51-07. PERFORMED OPS CHECK OF EMERGENCY LIGHTS IAW AMM 33-51-00. OPS CSDR YENA2020071600385Epsu · inoperativeDURING HEAVY MAINTENANCE, INOP EPSU EMERGENCY POWER SUPPLY UNIT EMERGENCY EXIT LT IN PASSENGER CABIN; (REF N/R 2020-172008) R & R EMERGENCY POWER SUPPLY UNIT (EPSU 11WL) ON EMERGENCY LT IN PASSENGER CABIN IAW AMM 33-51-38-400-001-A ITEM 1 THRU 4E AND AMM 33-51SDR DALA2020071502589Battery Pack · dischargedDURING SVC CK FOUND SEVERAL EMERGENCY LIGHTS INOP. T/S PER FIM 33-57 TASK 802. FOUND 5 EACH BATTERY PACKS INOP. REMOVED AND REPLACED M10699 BATTERY PACK PER AMM 33-51. OP'S CK GOOD. M730/M731/M733 AND M734 REMOVED AND REPLACED LISTED 4 EACH BATTERY PACKS SDR DALA2020071502586Switch · brokenDURING WAKEUP - EMERGENCY LIGHTS GUARDED SWITCH BROKEN. R/R EMERGENCY LIGHTS/PASSENGER OXYGEN CONTROL PANEL PER AMM 33-51. CKS GOOD.SDR DALA2020071302577Battery Pack · dischargedDURING INSPECTION FOUND EMERGENCY EXIT LIGHTS INOP FOR ROWS 11-19 AND ROWS 22-27. T/S PER FIM 33-50 FOUND M1676 AND M1671 BATTERY PACKS BAD. REPLACED BATTERY PACKS M1671 AND M1676 PER AMM 33-51 OPS CHECK GOOD.SDR ASAA2020071332891Light · inoperativeDURING ACCOMPLISHMENT OF T/C 78233008 FOUND ONE EMERGENCY AISLE LIGHT INOP BETWEEN ROWS 7 ABC AND 8 ABC. GROUNDED - YES. REMOVED AND REPLACED EAL REF AMM 33-51-03-960-805. OPS CHECKED GOOD.SDR AALA202007139004Power Supply · inoperativeAIRCRAFT NOT GROUNDED, LEFT MID-CABIN EMERGENCY POWER SUPPLY UNIT (EPSU) INOP. REMOVED AND REPLACED LT MID-CABIN EPSU PER JOB CARD 26C00033004.SDR DALA2020071502585Battery Pack · discharged12 INTERIOR EMERGENCY LIGHTS INOP BELOW OH BIN 4C, 24D, 27D, 41D, 43C, 44D, 2 EXIT SIGNS AT 3R DOOR, 2 EXIT SIGNS AT 3L DOOR, OVERWING EXIT SIGN BEHIND SEAT 26D, EXIT SIGN BETWEEN RIGHT SIDE OVERWING EXIT DOOR. RELAMPED 4C, REPLACED 6 EA BATTERY PACKS REPLACESDR R61A2020071400564Power Unit · dischargedEMERGENCY BATTERY FAULT ON EICAS. PERFORMED FIM TASK 33-50-00-810-802-1. CHARGED ELPU REF AMM 33-50-01.SDR SIMA202007131004Inverter · inoperativeFWD EMERGENCY ISLE LIGHTS INOP. R&R NR 3 INVERTER IAW AMM 33-50-11-000-801-A AND 33-50-11-400-801-A OPS CHECK GOOD NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA202007131002Epsu · inoperativeLIGHTED FWD SERVICE DOOR EMERGENCY EXIT SIGN INOP. R&R NR 1 EPSU IAW AMM 33-50-01 OPS CHECK GOOD.SDR ASAA2020071332890Battery Pack · failedEMERGENCY LIGHTS LOCATIONS FWD GALLEY RT SIDE FAILED 15 MIN CHECK. AND LOCATION FWD CABIN LT SIDE. GROUNDED - YES. REMOVED & REPLACED EMERG BATTERY PACKS LOCATION M2335 & M1672 REF AMM 33-51-06.SDR IPXA2020071317667Lamp · inoperativeEXTERIOR EMERGENCY LIGHT LAMP INOPERATIVE. R & R THE EXTERIOR EMERGENCY LIGHT LAMP IAW AMM 33 51 16 962 001. OPS CHECKED GOOD.SDR REXA2020071300599Light · inoperativeEXTERIOR EMERGENCY LIGHT BY SERVICE DOOR WOULDN`T ILLUMINATE. REMOVED & REPLACED THE EXTERIOR EMERGENCY LIGHT IAW AMM 33-51-21. OPS CHECKED GOOD.SDR REXA2020071300598Light · inoperativeFWD EMERGENCY CEILING FLOOD LIGHT INOPERATIVE. REMOVED AND REPLACED CHARGER 1 FOR EMERGENCY LIGHTS, OPS CHECK GOOD, IAW CRJ200 AMM 33-51-05.SDR CALA2020071201052Charger · inoperativeRH FWD OVERWING EMERGENCY LIGHT KAPUT. REPLACED CORRESPONDING BATTERY CHARGER AND BATTERY PER AMM 33-51-06, OPS NORMAL ADD EMP:94595SDR MASA2020071211123Battery Pack · inoperativeFWD/AFT GALLEY EMERGENCY FLOOD LIGHTS INOPERATIVE. REPLACED BATTERY PACKS AND LIGHT ASSEMBLIESSDR SWAA2020071499269Lens · unsecureEXIT SIGN COVER AFT SERVICE DOOR MID DOOR DRAWER SIDE WON'T STAY IN PLACE. SEEMS TO BE MISSING FASTENER. R & R AFT SERVICE EXIT LIGHT LENS ASSY IAW AMM 33-51-01 CLEARING 43656.SDR DALA2020071302581Trim Panel · damagedDURING INSPECTION FOUND EMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOPERATIVE. FOUND SEAT TRIM DAMAGED THAT HOLDS EMERGENCY LIGHT ASSY. REMOVED AND REPLACED TRIM.SDR DALA2020071302578Light · damagedDURING INSPECTION FOUND EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BOX ON SEAT TRIM PANEL AT SEAT 33D PER CMM 25-23. EMERGENCY LIGHT AND EMERGENCY LIGHT SYSTEM OP TEST GOOD PER AMM 33-51.
Back to JASC 3350