SDR SIMA20150604015Connector · brokenRIGHT OVERWING EMER LIGHT CONNECTOR P8562 BROKEN. R & R ADAPTER PART OF CONNECTOR ON RT OVERWING EMER LIGHT CONNECTOR P8562 IAW SWPM 20-50-01. OPERATIONS CHECKED GOOD. SEE TURNOVER FOR DETAILS.SDR SIMA20150604012Connector · brokenBROKEN ELEC CONNECTOR ON LT EMER LIGHT ON ACFT UNDER FWD FUSELAGE FAIRING. R & R ELEC CONNECTOR FOR LT EMER LIGHT ON ACFT UNDER FWD FUSELAGE FAIRING P08561 IAW SWPM 20-50-01.SDR AALA20150604009Wire · brokenSEAT 9D AISLE EMER LIGHTS INOPERATIVE. FOUND BROKEN WIRE AT SEAT 9D AISLE EMER LIGHT CONNECTOR. TERMINATED WIRE & PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00. SYSTEM CHECKED NORMAL.SDR YENA20150604175Wire · damagedDURING HEAVY MAINTENANCE, FOUND EMERGENCY LIGHT FAILS, ESCAPE LIGHT/EPSU. REPAIRED WIRE AT 7532VCA IAW ESPM 20-44-10. SYS OPS CHECK NORMAL.SDR DALA2015060403588Connector · damagedSEAT 37DEF EMERGENCY LIGHT INOPERATIVE. REPLACED THE CONNECTOR AT SEAT 37DEF IAW SWPM 20-30.SDR REXA2015060300567Ground Wire · damagedTASK CARD 900-53-900-106, RT OVERWING EXTERNAL EMER LIGHT FWD POSITION WIRE PROTECTIVE. REPAIRED FWD EMER EXIT OVERWING LIGHT GND WIRE IAW ESPM 20-32-00, NO DEFECTS NOTED.SDR DALA2015060503605Connector · disconnectedDURING INSPECTION FOUND EMERGENCY LIGHT AT 1AB, OVERHEAD BIN, INOPERATIVE AND MISSING LENS. MAINTENANCE FOUND QUICK DISCONECT OVER BIN NOT CONNECTED. RECONNECTED OPS CHECK NORMAL.SDR DALA2015060503604Connector · disconnectedDURING INSPECTION, FOUND EMERGENCY LIGHT AT 22 DEF, OVERHEAD BIN, INOPERATIVE. MAINTENANCE FOUND QUICK DISCONNECT OVER BIN NOT CONNECTED. RECONNECTED, OPS CHECK NORMAL.SDR DALA2015060403597Wire · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 14D IN THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND WIRES DAMAGED IN THE UNDERSEAT HARNESS. THE WIRE HARNESS WAS REPAIRED AND THE SYS RETURNED TO NORMAL OPERATION. LP 6717398.SDR A6WA201542803Connector · unsecureFLIGHT 3847, EMER FLOOR LIGHTS INOPERATIVE ROWS 2 - 5. SECURED CONNECTOR ON EMER LIGHTS FLOOR LEVEL ROWS 2 - 5. PERFORMED OPERATIONS CHECK IAW AMM 33-51-00-946-001. OPERATIONS CHECKED GOOD.SDR SWAA2015060540420Wire · brokenLEFT FWD BULLNOSE EMER LIGHT INOPERATIVE. REPAIRED ELEC WIRE IAW MM.SDR SWAA2015060540419Wire · brokenEMERGENCY EXIT LIGHT AFT OF LT OVERWING DOOR INOPERATIVE. REPAIRED ELEC WIRE IAW MM.SDR CALA2015060493853Connector · unsecureEMERGENCY EXIT FLOOR EEL INOPERATIVE AT FWD GALLEY & FWD LT COAT CLOSET. SECURED CONNECTOR. OPERATIONS CHECKED NORMAL.SDR SIMA20150602004Connector · disconnectedRIGHT EXTERNAL OVERWING EMER LIGHT INOPERATIVE. R & R RT EXTERNAL OVERWING EMER LAMP IAW TASK 33-50-07-000-801-A & TASK 33-50-07-400-801-A. OPERATIONS CHECKED, NO GOOD. AFTER PERFORMING TASK 33-50-07-000-802-A, FOUND CONNECTOR TO BE UNPLUGGED, PLUGGED IN COSDR DALA2015060303575Wire Harness · brokenDURING NON ROUTINE CHECK, FOUND SEAT EMERGENCY LIGHT OUT AT 8 ABC INOPERATIVE. REPAIRED BROKEN SEAT HARNESS WIRE AND OPS CHECK WAS NORMAL.SDR A6WA201542801Wire · brokenFLIGHT NR 3746, FLOOR LEVEL EMER LIGHTS INOPERATIVE ROW 7 & AFT. PULLED UP EMER LIGHTING STRIP, INSPECTED WIRING. FOUND WIRE BROKEN AT J 6LY & P7LY. REINSTALLED STRIP FOR FERRY IAW AMM 33-51-01.SDR DALA2015060203583Ground Wire · looseFOUND CEILING EMERGENCY LIGHT INOPERATIVE AT 40. MAINTENANCE FOUND GROUND WIRE LOOSE AND SECURED. SYSTEM OPERATION IS NORMAL.SDR DALA2015060103551Connector · disconnectedEMERGENCY LIGHTS INOPERATIVE ROWS 31-37 RT AND LT. FOUND CONNECTOR DISCONNECTED. SECURED THE CONNECTOR. CHECKED GOOD.SDR A6WA201542800Wire · unsecureFLIGHT 3849. 3845, 3849, & 3983 EMER LIGHT STRIP 1ST SEGMENT AT ROW 1 PULLED UNLIT. SECURED LIGHTING STRIP WIRES & FLOOR TRACK IAW AMM 33-51-01. OPERATIONS CHECKED GOOD.SDR ASOA2015060813067Wire · brokenGALLEY EMERGENCY LIGHT WIRE IS BROKEN AT SPLICE, MARKED WITH RED TAPE. INSTALLED NEW SPLICE ON GALLEY WATER LINE HEATERS IAW GSPM 20-16-00. CONTINUITY CHECK GOOD. NO DEFECTS NOTED.SDR DALA2015060103596Connector · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 3D IN THE CABIN WAS INOPERATIVE. MAINTENANCE REINSTALLED A PULLED PIN IN THE CONNECTOR AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION. LP 7068108.SDR DALA2015060103558Connector · disconnectedIN-SEAT ESCAPE PATH LIGHT AT ROW 27R INOPERATIVE. FOUND CONNECTOR DISCONNECTED AT 27F. RECONNECTED, OPS OK.SDR AALA20150530001Connector · brokenSEAT 10D EMER LIGHT INOPERATIVE. R & R CONNECTORS TO SEAT 10D EMER LIGHT BY SEAT SIDEWALL IAW AMM 20. SYS CHECKED NORMAL.SDR DALA2015060103550Wire Harness · damagedESCAPE PATH LIGHT INOPERATIVE AT SEAT 18C, FOUND PIN MISSING AT HARNESS PIGTAIL ASSY. INSTALLED NEW PIN.SDR DALA2015060103559Wire · brokenEMERGENCY LIGHTS AT MAIN CABIN ROWS 1 AND 32 INOPERATIVE. FOUND BROKEN WIRES AT MAIN CABIN SEAT ROW 1 AMD 32 SPLICED WIRES AT BROKEN LOCATION IAW SWPM 20-30-12.SDR DALA2015060103556Connector · damagedDURING LINE CHECK, MAINTENANCE FOUND THE EMERGENCY LIGHTS INOPERATIVE AT SEAT ROWS 16 RT, 01 RT AND 31 RT. MAINTENANCE REPINNED THE CONNECTORS AND THE OPS CHECK WAS GOOD. LP 7002245.SDR AALA20150528003Connector · unsecureEMERGENCY LIGHTS ROW 22 INOPERATIVE. SECURED CONNECTOR AT SEAT 22 IAW AMM 33-51-00. PERFORMED OPERATIONAL CHECK, NO DISCREPANCIES NOTED.SDR AALA20150527003Wire Harness · damagedEMERGENCY PATH LIGHTING HARNESS DAMAGED AT SEAT 28 DEF & 30 DEF. R & R HARNESS. SYS CHECKED NORMAL.SDR AALA20150527001Wire · brokenEMERGENCY LIGHTS INOPERATIVE ON SEAT 20B. FOUND BROKEN WIRE UNDERNEATH SEAT 20B AT CONNECTOR. REPINED CONNECTOR IAW MM 20-64-17. PERFORMED OPERATIONAL CHECK IAW MM 33-51-00. SYS CHECKED NORMAL.SDR HNAA2015052700170Connector · damagedEMERGENCY LIGHTS ARE NOT ILLUMINATED WITH F/A SWITCH. FOUND CONNECTOR 3351, P33, WIRES 5A22, PIN 3 AND 10A22, PIN 6 SWAPPED AND WIRES 16B22, PIN 7 AND 2G22, PIN 8 SWAPPED. INSTALLED ALL WIRES IN CORRECT POSITION IAW 33-51-00. OPS CHECKED GOOD.SDR SIMA20150526011Wire · brokenEMERGENCY LIGHT STRIP WIRE AT 231GF IS BROKEN. REPAIRED EMER LIGHT STRIP WIRE AT 231GF IAW SWPM 20-00-03. CRIMPER NR 102, SEE BOW 192272 FOR EMER LIGHT STRIPS INSTALL.SDR DALA2015052703465Connector · unsecureROW 43 RIGHT IN-SEAT EMERGENCY PATH LIGHT INOPERATIVE. FOUND CONNECTOR LOOSE UNDER SEAT 43F. SECURED CONNECTOR, OPS OK.SDR AALA20150526005Connector · looseEMERGENCY PATHWAY LIGHT ON SEAT 5 E - F INOPERATIVE. SECURED LOOSE CONNECTOR. SYS CHECKED NORMAL.SDR DALA2015052603482Connector · unsecureDURING INSPECTION, FOUND EMERGENCY EXIT SIGNS INOPERATIVE. SECURED LOOSE CONNECTION ON EMERGENCY EXIT SIGN AND FUNCTIONAL CHECK WAS NORMAL.SDR AALA201505279006Connector · disconnectedEMERGENCY PATH LIGHT INOPERATIVE AT ROW 12L. TERMINATED CONNECTOR AT ROW 12L.SDR SIMA20150524004Ground Wire · looseSERVICE DOOR EXTERNAL EMER LIGHT INOPERATIVE. CLEANED & TORQUED GND CONNECTION WIRE ON SERVICE DOOR EXTERNAL EMER LIGHT ASSEMBLY IAW AMM 33-50-10. OPERATIONS CHECKED GOOD.SDR DALA2015052603463Wire Harness · damagedDURING INSPECTION, FOUND EMERGENCY ESCAPE PATH LIGHTS AT SEATS 24 AND 32 ARE INOPERATIVE. MAINTENANCE REPLACED WIRE HARNESS AT SEAT 32, R & R TERMINAL END ON SEAT 24. OPS TEST OK.SDR SIMA20150522005Wire · brokenEMERGENCY LIGHT STRIP NR 7 ON LT SIDE OF FLOORBOARD 251HF HAS BROKEN WIRE. REPAIRED WIRE W192-8710-22 ON EMER LIGHT STRIP NR 7 IAW SWPM 20-21-00. SEE BOW 192974 FOR OPERATIONS CHECK. CALIBRATED EQUIPMENT USED, CRIMPER SN 611497.SDR SIMA20150522004Wire · brokenLEFT NR 1 EMER LIGHT STRIP HAS BROKEN WIRES. R & R LT NR 1 EMER LIGHT STRIP IAW AMM 33-50-12. SEE BOW 192974 FOR FINAL INSTALLATION & OPERATIONAL TEST.SDR DALA2015052703483Connector · unsecureEMERGENCY LIGHT AT MAIN CABIN SEAT ROWS 3 AND 23 INOPERATIVE. TROUBLESHOT AND FOUND LOOSE CONNECTION, SECURED CONNECTORS AT SEAT ROWS 2 AND 23. TESTS WERE NORMAL.SDR SIMA20150521007Wire · brokenNR 6 EMER LIGHT STRIP HAS BROKEN WIRE. R & R NR 6 EMER LIGHT FLOOR STRIP IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.SDR REXA2015052100519Connector · disconnectedFOUND FWD EXTERIOR EMER OVERWING LIGHT INOPERATIVE, RT SIDE. FOUND CONNECTOR J396 DISCONNECTED, CONNECTED IAW AMM 25-26-01. OPS CHECKED GOOD AT THIS TIME IAW AMM 33-51-00.SDR DALA2015052103573Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT SEAT 13DE IN THE CABIN WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYSTEM. LP 6731688.SDR ASOA2015052612909Connector · damagedF/A ADVISES OVERHEAD EMERGENCY LIGHT AT ROW 4 IS INOPERATIVE. REPINNED SOCKET AT ROW 4 FLOOD LIGHT IAW ESPM 20-16-00. OPS CHECK GOOD, DMIL CLEARED PLACARD, REMOVED.SDR CALA2015052693817Pin · backed outPER A CHECK, SEAT EMER EXIT LIGHT AT 19HJK, INOPERATIVE. FOUND ONE PIN ON POWER CABLE COMING FROM WALL PUSHED IN, SECURED PIN. OPERATIONS CHECKED OK.SDR CALA2015052693814Connector · brokenPER A CHECK, SEAT EMER EXIT LIGHT AT 35ABC, INOPERATIVE. FOUND CONNECTOR LOCK BROKEN. REPLACED CONNECTOR & PINS. OPERATIONS CHECKED OK.SDR CALA2015052193808Pin · backed outPER A CHECK SEAT EEL AT 19HJK, INOPERATIVE. FOUND ONE PIN ON POWER CABLE COMING FROM WALL PUSHED IN. SECURED PIN, OPERATIONS CHECKED OK.SDR CALA2015052193805Connector · brokenPER A CHECK, SEAT EEL AT 35ABC, INOPERATIVE. FOUND CONNECTOR LOCK BROKEN. REPLACED CONNECTOR & PINS. OPERATIONS CHECKED OK.SDR CALA2015052693811Connector · unsecureEMERGENCY EXIT FLOOR LIGHT INOPERATIVE, JUST OUTSIDE OF AFT INBD LAVATORY. SECURED CONNECTOR. OPERATIONS CHECKED NORMAL.SDR CALA2015052193802Connector · unsecureEMERGENCY EXIT FLOOR EEL INOPERATIVE JUST OUTSIDE OF AFT INBD LAVATORY. SECURED CONNECTOR, OPERATIONS CHECKED NORMAL.
Back to JASC 3397