JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2015051900408Connector · disconnectedSPT AFT LEFT LAVATORY AFT EMER EGRESS LIGHT INOPERATIVE. CONNECTED CONNECTOR P16 AT LAVATORY D IAW AMM 33-51-14. OPERATIONS CHECKED GOOD.SDR AALA201505199003Connector · looseEMERGENCY LIGHT AT ROW 8 LT INOPERATIVE. SECURED LOOSE UNDER SEAT CONNECTOR. OPERATIONS CHECKED NORMAL.SDR DALA2015051703365Wire · brokenMSP MAINTENANCE FOUND EMERGENCY EXIT AISLE AT 22A INOPERATIVE. MSP MAINTENANCE SPLICED BROKEN WIRE REF SWPM 20, SEAT 22A EMERGENCY LIGHT CHECKED OK.SDR CALA2015051893794Wire · brokenTWO EACH WALL MOUNTED EEL AT AFT GALLEY INOPERATIVE. FOUND BROKEN WIRE AT POWER HARNESS AT PIN ON CONNECTOR. REPLACED PIN. OPERATIONS CHECKED OK.SDR SIMA20150516002Connector · disconnectedRIGHT OVERWING EMER LIGHT IS INOPERATIVE. FOUND CONNECTOR IN BACK OF LIGHT ASSEMBLY TO BE DISCONNECTED, RECONNECTED IT AS REQUIRED. OPERATIONS CHECKED GOOD.SDR AALA20150516001Wire · damagedEMERGENCY LIGHT WIRE W1228-107-22 DAMAGED 6 INCHES FROM CONNECTOR D5660P, ON AE0218 P37 DISCONNECT PANEL. REPAIRED WIRE IAW SWPM 20-30-12 WITH GOOD CONTINUITY. PERFORMED OPERATIONAL CHECKED IAW WDM 33-51-21 & AMM 33-51-00.SDR VNAA2015051400017Wire · pulledCREW REPORTED FLOOR STRIP EMERGENCY LIGHTS INOPERATIVE AFTER ROW 8. MAINTENANCE INSPECTED EMERGENCY LIGHTING AND FOUND WIRING PULLED FROM CONNECTOR BY LAVATORY. MAINTENANCE INSTALLED NEW CONNECTORS ON AFT EMERGENCY LIGHTING STRIP AND PERFORMED CHECKS IAW AMM.SDR SWAA2015061640780Wire · brokenAFT BULLNOSE LIGHTED EXIT SIGN WIRE BROKEN. R & R SIGN IAW AMM.SDR SIMA20150511007Wire · brokenEMERGENCY LIGHT STRIP NR 3 HAS BROKEN WIRE ON LIGHT STRIP SIDE. R & R EMER LIGHT STRIP NR 3 IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.SDR SIMA20150511006Connector · damagedPOWER SUPPLY HARNESS, ACFT SIDE, TO EMER LIGHT STRIP NR 6 HAS A DAMAGED CONNECTOR. INSTALLED CONNECTOR & PIN ON POWER SUPPLY HARNESS, ACFT SIDE, TO EMER LIGHT STRIP NR 6 IAW SWPM 20-21-00, 20-50-00 & 20-50-01. SEE NRTC E450553 FOR OPERATIONS CHECK.SDR DALA2015051403355Ground Wire · looseFORWARD GALLEY EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE FOUND LOOSE GROUND CONNECTION AT GD4730-DC AND RETERMINATED. SYSTEM OPERATION IS NORMAL.SDR SIMA20150511005Connector · missingPOWER SUPPLY HARNESS, ACFT SIDE, TO EMER LIGHT STRIP NR 4 IS MISSING A CONNECTOR. INSTALLED CONNECTOR & PIN ON POWER SUPPLY HARNESS, ACFT SIDE, TO EMER LIGHT STRIP NR 4 IAW SWPM 20-21-00, 20-50-00 & 20-50-01. SEE NRTC E450553 FOR OPERATIONS CHECK.SDR SIMA20150511003Wire · brokenEMERGENCY LIGHT STRIP NR 2 HAS BROKEN WIRE ON LIGHT STRIP SIDE. EMER LIGHT STRIP NR 2 IS INOPERATIVE. R & R EMER LIGHT STRIP NR 2 IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.SDR SWAA2015060340354Wire · deterioratedEMERGENCY EXIT LIGHT ELEC WIRE DETERIORATED AT STATION 907. REPAIRED WIRE IAW SWPM.SDR QXEA2015051000242Wire · shortedAFT LT AND AFT RT DOOR EMERGENCY IDENT SIGNS, FS X699.27, FAIL TO ILLUMINATE WHEN SELECTED TO "ON". REPLACED POWER SUPPLY UNIT. INSPECTED AND FOUND PIN 10 OF CONNECTOR 3351-P6, READING .51 ABOVE TO GROUND. FOUND SHORT IN WIRE 3351-P20. REPAIRED DAMAGED WIRESDR VNAA2015051000014Wire · brokenCREW REPORTED PASSENGER DOOR EMERGENCY EXIT SIGN ON FORWARD CLOSET OUT. MAINTENANCE INSPECTED, FOUND BROKEN WIRE AT CONNECTOR, R & R CONNECTOR AND MULE PIN AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR AALA201505139001Wire Harness · unsecureROW 31, SEAT GH, EMER LIGHT WONT ILLUMINATE. SECURED WIRES GOING TO SEAT 31GH.SDR SWAA2015051539738Wire · brokenDOME LIGHT BEHIND PILOTS SEAT GOING TO EMER EXIT LIGHT FIXTURE, WIRE BROKEN. R & R LIGHT IAW AMM.SDR AALA201505119009Cable · disconnected7A SEAT MOUNTED FLOOR PROX EMER LIGHT INOPERATIVE. CONNECTED THE LOOSE CABLE INSIDE THE SEAT.SDR AALA20150509007Wire · brokenSEAT 3A EMER AISLE LIGHT WIRE BROKEN. REPLACED LIGHT ASSEMBLY IAW 767 33-51-01 WITH GOOD OPERATIONAL CHECK.SDR AALA201505119007Wire · pulledEMERGENCY LIGHT WIRE FOR LT FWD WIND SCREEN PULLED OUT OF WALL. REPLACED THE WIRE ON THE WINDSCREEN.SDR AALA20150508011Wire · shortedFORWARD SECTION OF SEAT EMER LIGHTS SHORTED ON WIRE PAIR. REPLACED EXIT LIGHT AT FWD GALLEY.SDR CALA2015051193757Connector · unsecurePER A CHECK , SEAT 48 LT, SEAT EEL INOPERATIVE. SECURED UNDER SEAT CONNECTION & LIGHT OPERATIONS NORMAL.SDR SWAA2015051139519Connector · looseG1 EMER LIGHT WIRE LOOSE. R & R CONNECTOR IAW WDM.SDR DALA2015050803183Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THE SEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE AT SEAT 14D. MAINTENANCE CONNECTED A DISCONNECTED CONNECTOR AND THE OPS CHECKED GOOD.SDR SIMA20150506003Wire · brokenPROXIMITY LIGHT NR 6 HAS BROKEN WIRES. R & R PROX LIGHT NR 6 IAW AMM 33-50-12. SEE NRTC BOW 188190 FOR FINAL INSTALL & OPERATIONS CHECKS.SDR AALA20150508009Connector · out of positionTWO OVERHEAD EMER AISLE LIGHTS INOPERATIVE. TROUBLE SHOT IAW AMM 33-51-11 & FOUND FASTON TAB CONNECTIONS SWAPPED. REPOSITIONED CONNECTIONS WITH GOOD OPERATIONAL CHECKS IAW AMM 33-51-11.SDR PNSA20150506001Wire · brokenROW 4A OVERHEAD LIGHT INOPERATIVE, 37LN. REPLACED BULB, EXIT MARKER ON LT EMER EXIT INOPERATIVE. FOUND WIRE BROKEN OFF LAMP ASSEMBLY, 45LN. REPLACED LAMP ASSEMBLY. OPERATIONS CHECKED GOOD.SDR CALA2015050600373Wire · brokenFOR SDR REPORTING EMER LIGHT L33946 INOPERATIVE IAW WDM 33-51-03. FOUND WIRE SM0014 TO LIGHT ASSEMBLY BROKEN IAW SWPM 20-10-13. REPAIRED THE WIRE BY USE SPLICE, STATION 1496, WL 221. REINSTALLED THE LIGHT ASSEMBLY & CHECKED SATISFACTORY IAW AMM 33-51-05.SDR DALA2015050703116Wire · brokenDURING NON-ROUTINE CHECK, FOUND CABIN EMERGENCY LIGHTS INOPERATIVE AT SEAT ROW 7AB. T/S AND FOUND BROKEN WIRE AT CABIN SEAT ROW 7 A/B. SPLICED WIRE AND FUNCTIONAL CHECK WAS NORMAL.SDR CALA2015050693663Connector · looseEMERGENCY PATH LIGHT AT SEAT ROW 25H INOPERATIVE. SECURED LOOSE CONNECTOR AT ROW 25H. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00.SDR CALA2015050600372Wire · brokenFOR SDR REPORTING & PLA ID. EMER LIGHT L33946 INOPERATIVE IAW WDM 33-51-03. FOUND WIRE SM0014 TO LIGHT ASSEMBLY BROKEN IAW SWPM 20-10-13. REPAIRED THE WIRE BY SPLICE STATION 1496, WL221, RBL 33.5. REINSTALLED LIGHT ASSEMBLY & CHECKED GOOD IAW AMM 33-51-05SDR ASOA2015060212967Splice · wrong partWARDROBE INBD EMERGENCY EXIT LIGHT HAS 1 EA INCORRECT SPLICE INSTALLED. R & R SPLICE ON WARDROBE FLOOR LEVEL EMERGENCY EXIT SIGN IAW ESPM 20-17-00 AND AMM 33-51-10-400-801. EMERGENCY LIGHT OPS TEST GOOD IAW AMM 33-51-00-710-801.SDR SIMA20150503013Connector · out of positionLEFT AFT EXTERIOR EMER LIGHT IS INOPERATIVE. REPLACED P5230 & J5230, FOUND IT WAS CONNECTED TO P873. CONNECTED TO THE RIGHT PLUGS, ALL WORK DONE IAW ESPM 20-12-00. OPERATIONS CHECKED GOOD.SDR SWAA2015051239585Connector · missingG1 GALLEY EMER EXIT LIGHT CONNECTOR MISSING. INSTALLED CONNECTOR IAW AMM.SDR AALA201505069001Connector · disconnectedSEAT MOUNTED ESCAPE PATH LIGHT AT 5H INOPERATIVE. CONNECTED THE CONNECTOR AT SEAT 5H. EMERGENCY LIGHT AT SEAT 5H OPS CHECKED GOOD.SDR SWAA2015050539301Wire · damagedLEFT DOOR LOWER EMER EXIT LIGHT INOPERATIVE. R & R WIRE IAW SWPM & WDM.SDR DALA2015050403051Wire · exposedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE . FLOOR TRACK LIGHTING WIRES. EXPOSED INTERIOR. TUCKED WIRES, OPS CHECK OK.SDR SIMA20150503006Connector · looseSIDEWALL EMERGENCY LIGHT OF LEFT EXIT ROW INOPERATIVE. SECURED LOOSE CONNECTOR OF EXIT IDENTIFIER IAW AMM 33-50-14-400-801-A. OPS CHECKED GOOD.SDR DALA2015050403042Wire · brokenDURING LINE CHECK , MAINTENANCE NOTED EMERGENCY EXIT SIGN WIRE SPLICES BROKEN AT ROW 19AB. REPLACED BROKEN WIRE CONNECTORS IAW WDM 33-51 AND CHECKS GOOD.SDR IPXA2015050488674Wire · brokenEMERGENCY LIGHTS INOPERATIVE T/S IAW FIM 33-52-01-00, BLOCKS 1-15. FOUND WIRE B362-154-20 SHORTED TO GROUND, REF WDM 33-52-01. REPAIRED WIRE IAW SWPM 20-10-03, EMERGENCY LIGHTS OPS NORMAL. PRIOR TO REPAIRING WIRE, REPLACED POWER SUPPLY IAW MM 33-51-01, NO HELPSDR AALA20150503001Wire · damagedINOPERATIVE EMERGENCY EXIT LIGHT L781 AT LT AISLE CEILING PANEL AT SEAT 12B, BS 681. SPLICED WIRES SMZ90230 & SMZ90229 IAW SWPM 20-30-12 & DWG MZS18711250 REV E. OPERATIONAL CHECKED GOOD IAW AMM 33-51-00-725-247.SDR DALA2015043003072Wire Harness · damagedMAINTENANCE FOUND EMERGENCY LIGHTS INOPERATIVE AT SEAT 21D AND 37D. SEAT HARNESSES IN BOTH LOCATIONS WERE REPLACED AND OPS CHECKED GOOD. LP6504044.SDR CALA2015043000348Wire · shortedON TAKEOFF ROLL FLIGHT CREW REPORTED STRONG SMELL OF RUBBER IN COCKPIT & CABIN. FLIGHT ATTENDANTS REPORTED A STRONG ELECT SMELL, WOULD COME & GO DURING ALL PHASES OF FLIGHT, BECAME STRONG AGAIN ON DECENT AT 4K THROUGHOUT ACFT. NO SMOKE REPORTED. TRACKED ODSDR RAIA201504290001Wire · brokenFLOOR PROXIMITY EMERGENCY PATH LIGHTING HAS BROKEN WIRE AT EMERGENCY EXIT ROW. MAINTENANCE REPAIRED WIRE, OPS CHECK GOOD.SDR CALA2015050193643Wire · damagedOPERATIONAL CHECK ON PAX CABIN LIGHTS & SIGNS. REPAIRED WIRE AT SEAT 40 CTR ON EMER LIGHT PATH LT SIDE. SYS CHECKED NORMAL IAW MM 33-51-00.SDR DALA2015043002972Connector · brokenDURING LINE CHECK, MAINTENANCE FOUND THE SEAT ROW 16ED EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REPAIRED A BROKEN CONNECTOR AND THE LIGHTS TESTED SATISFACTORILY.SDR DALA2015043003073Wire · brokenMAINTENANCE FOUND INTERIOR EMERGENCY LIGHTS INOPERATIVE SEAT 28, 39, 41 AND 44. SAT MAINTENANCE TROUBLESHOT AND FOUND CONNECTORS AND BROKEN WIRES. THEY RE-SECURED THE CONNECTORS AND SPLICED THE BROKEN WIRES. LP7255621.SDR AALA201504299002Wire Harness · shortedSEAT 27 ABC SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE. PLACED SEAT 27 ABC. REPLACED WIRING HARNESS FOR SEAT 27 ABC.SDR DALA2015043003015Connector · detachedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT THE FWD RT GALLEY SIDEWALL WAS INOPERATIVE. MAINTENANCE FOUND A CONNECTOR IN THE WIRE HARNESS AT THE FIRST ROW SEATS UNPLUGGED, RECONNECTED IT, AND FUNCTIONALLY CHECKED THE SYSTEM. LP 6721096.
Back to JASC 3397