JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20150224006Wire Harness · brokenSEAT MOUNTED ESCAPE PATH LIGHTING AT SEATS 32 - 40 LT SIDE FAILED FUNCTIONAL TEST. FOUND BROKEN WIRE AT SEAT 40AB, SEAT INTERFACE HARNESS. REPLACED HARNESS & TESTED IAW AMM 33-51-00. SYS CHECKED NORMAL.SDR DALA2015022401626Wire · broken1 EMERGENCY LIGHT AT ROW 2AB INOPERATIVE, REPAIRED BROKEN WIRE.SDR DALA2015022401621Wire · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE FLOOR MOUNTED EMERGENCY PATHWAY LIGHTING FOR ROWS 1-12 AND THE OVERHEAD LIGHTS AT DOORS L1 & R1 WERE INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE AT ROW 11E WAS SHORTING TO GROUND. WIRE WAS REPAIRED WITH A SPLICESDR DALA2015022401673Connector · damagedDURING NON ROUTINE CHECK, FOUND EMERGENCY EXIT FLOOR PROXIMITY ESCAPE PATH LIGHT AT SEAT ROW 7ABC IS INOPERATIVE. TERMINATED LOCK CONNECTOR AND FUNCTIONAL CHECKED WAS NORMAL.SDR DALA2015022401620Connector · inoperativeDURING INSPECTION, FOUND EMERGENCY LIGHT AT ROW 12 IS INOPERATIVE. MAINTENANCE REPLACED CONNECTOR REF SWPM 20-40-01. OPS CKS GOOD.SDR DALA2015022401619Connector · inoperativeDURING INSPECTION, FOUND EMERGENCY LIGHT AT ROW 24 IS INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSY AND SOCKET CONNECTOR, REF SWPM 20-42-01. OP CKS GOOD.SDR DALA2015022501640Wire · disconnectedDURING NON ROUTINE CHECK, FOUND SEAT 10ABC RED SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE. RECONNECTED WIRES TO FWD RED SEAT EMERGENCY LIGHT AND FUNCTIONAL CHECK WAS NORMAL.SDR SIMA20150220009Connector · missingFOUND EMER LIGHT AFT CABIN CEILING INOPERATIVE DUE TO PULLED WIRE. INSPECTED & FOUND CONNECTOR GONE. INSTALLED NEW CONNECTOR IAW SWPM 20-13-02. OPERATIONAL CHECKED GOOD.SDR CALA2015022093151Cable · defectiveDOOR 3 LAVATORY RT & CTR EEL FOUND INOPERATIVE. R3 DOOR PAX SEAT TO LAVATORY EEL CABLE REPLACED. EMER LT TEST CARRIED OUT & FOUND NORMAL IAW AMM 33-51-13 REV 171.SDR CALA2015022093150Cable · defectiveLAVATORY 111 LT WALL MOUNTED EEL FOUND INOPERATIVE. C ZONE LT LAST SEAT EEL CABLE REPLACED. EMER LT TEST CARRIED OUT & FOUND NORMAL IAW AMM 33-51-13 REV 171.SDR CA150220006Switch · shorted(CAN) SPARKS AND SMOKE SEEN COMING FROM OVERHEAD PANEL. EMERGENCY DECLARED. FOUND TAXI LIGHT SWITCH SHORTED. TAXI AND LANDING LIGHT SWITCHES REPLACED. NO FURTHER ISSUES.SDR SIMA20150218004Wire · nickedFLOOR PROX LIGHT WIRE INSULATION NICKED AT FRAME 49. REPAIRED THE FLOOR PROX LIGHT WIRE INSULATION AT FRAME 49 IAW SWPM 20-21-00.SDR SIMA20150218003Wire · nickedCABIN MOST AFT FLOOR PROXIMITY LIGHT WIRE INSULATION NICKED AT LT OMEGA BEAM. REPAIRED THE CABIN MOST AFT FLOOR PROXIMITY LIGHT WIRE INSULATION AT LT OMEGA BEAM IAW SWPM 20-21-00.SDR USAA2015022000002Wire Harness · brokenEMERGENCY LIGHT FOR SEAT ROW 30 INOPERATIVE, DUE TO BROKEN WIRE HARNESS AT CONNECTOR UNDER SEAT 30A. REPLACED EMER LIGHT HARNESS AT SEAT 30A & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKED IAW AMM 33-51-19 PB 0401.SDR CALA2015022093158Connector · unsecureSEAT MOUNTED EMER EXIT LIGHT INOPERATIVE AT SEAT 37 LT. SECURED CONNECTOR. OPERATIONS CHECKED NORMAL.SDR CALA2015022093154Cable · defectiveUD STAIR WALL MOUNTED EEL FOUND INOPERATIVE. UD STAIR WALL MOUNTED EEL CABLE REPLACED. EMER LT TEST CARRIED OUT & FOUND NORMAL IAW AMM 33-51-12 REV 171.SDR SIMA20150217015Wire · brokenEMERGENCY LIGHT STRIP NR 2 HAS BROKEN WIRES. R & R EMER LIGHT STRIP NR 2 IAW AMM 33-50-12. SEE BOW 181199 FOR OPERATIONS CHECK.SDR SIMA20150217014Connector · not seatedEMERGENCY FLOOR PROX LIGHTS NR 4 & 5, RT & LT EMER EXIT SIGNS INOPERATIVE. RESEATED ELEC CONNECTOR ON EMER LIGHTS POWER SUPPLY NR 3 IAW AMM 33-50-04 & SWPM 20-50-00. OPERATIONAL CHECKED GOOD.SDR SIMA20150217013Wire · brokenEMERGENCY LIGHT STRIP NR 7 HAS BROKEN WIRES. R & R EMER LIGHT STRIP NR 7 IAW AMM 33-50-12. SEE BOW 181199 FOR OPERATIONS CHECK.SDR SIMA20150217008Wire · brokenEMERGENCY LIGHT STRIP NR 8 HAS A BROKEN WIRE ON THE ACFT SIDE. INSTALLED NEW CONNECTOR AT EMER LIGHT STRIP NR 8 IAW SWPM 20-00-03, SWPM 20-21-00 & WM 91-10-02. CRIMPER EASI 6277, POSITIONER SER 7151. FOR OPERATIONS CHECK SEE BOW 181199.SDR AALA20150301001Wire · damagedL645 WING LT SIDE GND ILLUMINATION LIGHT AT STATION 1230, WL 180, LBL 94 IS INOPERATIVE. TERMINATED WIRE W4784-177-14 TO L645. OPERATIONAL CHECK GOOD IAW WDM 33-51-21 & MM 33-51-06-962-201. SYS CHECKED NORMAL.SDR CALA2015022093164Connector · unsecureSEAT MOUNTED EMER EXIT LIGHT INOPERATIVE. AT 33 LT, SECURED UNDER SEAT CONNECTOR. OPERATIONS CHECKS NORMAL.SDR CALA2015022093153Connector · disconnectedL3 DOOR EXIT SIGN IN AISLE OVERHEAD INOPERATIVE. FOUND CONNECTOR D6037P DISCONNECTED. RECONNECTED CONNECTOR D6037P IAW WDM 33-51-23. OPERATIONS CHECK SATISFACTORY IAW AMM 33-51-01, SUBTASK 33-51-01-710-002.SDR SWAA2015021936725Connector · disconnectedL2 DOOR EMER EXIT LIGHT INOPERATIVE. CONNECTED CONNECTOR IAW SWPM & AMM.SDR DALA2015021801382Wire · brokenDURING SERVICE CHECK, FOUND EMERGENCY LIGHT AT SEAT 6C MISSING A LENS AND LIGHTS AT SEATS 24D, 26D, AND 40D INOPERATIVE. INSTALLED LENS AT SEAT 6C AND REPAIRED BROKEN WIRES AT HARNESS CONNECTORS AT SEATS 24, 26 AND 40D. ALL OPS CK OK, REF SWPM 20-30-12.SDR DALA2015021801380Wire · brokenDURING INSPECTION, FOUND ROW 22 EMERGENCY LIGHT INOPERATIVE. REPAIRED BROKEN WIRE AND FUNCTIONAL CHECKED NORMAL.SDR ASOA20150217015HSWire Harness · burnedTHE CREW REPORTED SMOKE AND FIRE ABOVE 5A SEEN AND SMELLED BY LIGHT FIXTURE. THE ACFT WAS FERRIED, WHERE IT LANDED WITHOUT INCIDENT, MAINTENANCE INSPECTED ATHE ACFT AND R & R THE AFFECTED SIDEWALL LIGHT HARNESS, OPERATIONALLY TESTED WITH NO DEFECTS NOTED AND SDR ASOA20150217015Wire Harness · burnedTHE CREW REPORTED SMOKE AND FIRE ABOVE 5A SEEN AND SMELLED BY LIGHT FIXTURE. THE ACFT WAS FERRIED, WHERE IT LANDED WITHOUT INCIDENT, MAINTENANCE INSPECTED ATHE ACFT AND R & R THE AFFECTED CEILING LIGHT WIRING HARNESS, OPERATIONALLY TESTED WITH NO DEFECTS NOTESDR DALA2015030201770Wire · pulledDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTS IN ROWS 13-23DEF OF THE CABIN WERE INOPERATIVE. MAINTENANCE FOUND WIRES PULLED OUT OF A SPLICE AT 13DEF. THE WIRE WAS REPAIRED WITH A NEW SPLICE AND THE SYS RETURNED TO NORMAL OPERATION.SDR CA150217002Connector · melted(CAN) THE LAVATORY VANITY MIRROR HAS 3 LIGHTING ASSEMBLIES POWERED BY SEPARATE BALLASTS, PRECISION WINDING, PN 6900054-003. THEY ARE MOUNTED IN PROXIMITY OF THE HAND SOAP DISPENSER RESERVOIR. AN OVERFLOW OF THE SOAP DISPENSER RESERVOIR TOOK PLACE EITHER DUE SDR FDEA201502140532Wire · damagedCOCKPIT EMER LIGHT INOPERATIVE. REWIRED IAW WDM CH 33-51-12. OPERATIONS CHECKED NORMAL.SDR YENA20150214019Wire Harness · failedON MAINTENANCE CHECK, FOUND CABIN EMERGENCY LIGHT ROWS 5, 15, 23L INOPERATIVE. R & R WALL TO SEAT HARNESS IAW AMM 33-51-19. TESTING OF CABIN EMERGENCY LIGHT CHECK GOOD IAW 33-51-60.SDR AALA20150214005Connector · not seatedSEAT 32D EMER EXIT LIGHT INOPERATIVE. RESEATED CONNECTOR FOR EMER LIGHT AT SEAT 32D. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00. SYS CHECKED NORMAL.SDR AALA20150214003Connector · not seatedSEAT 15D EMER EXIT LIGHT INOPERATIVE. RESEATED CONNECTOR FOR EMER LIGHT AT SEAT 15D. PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00. SYS CHECKED NORMAL.SDR UIEA2015021600122Connector · looseREF MDDR 54771 PATH LIGHT AT L2 JUMP SEAT INOPERATIVE. SECURED LOOSE CONNECTOR AT LIGHT CAPSULE. OPERATIONS CHECKED GOOD IAW AMM 33-51-12. PLACARDS REMOVED MC NOTIFIED.SDR AALA20150215001Connector · disconnectedSEAT MOUNTED EMER PATH LIGHTS INOPERATIVE AT SEATS 32AB & 33AB. SECURED SEAT 32 & 33AB EMER LIGHTS CONNECTOR. PERFORMED OPERATIONAL CHECK SEAT 32 & 33AB IAW AMM 33-51-10. SYS CHECKED NORMAL.SDR SIMA20150212006Connector · brokenEMERGENCY LIGHT STRIP SPLICE CONNECTOR BROKEN AT FS 38. REPLACED CONNECTOR AT SPLICE SP9103 IAW SWPM 20-50-00.SDR SIMA20150212005Wire · brokenNUMBER 1 LT CABIN EMER LIGHT HAS A BROKEN WIRE ON THE FUSELAGE SIDE. REPLACED CONNECTOR AT NR 1 LT EMER LIGHT IAW SWPM 20-50-00.SDR SIMA20150212004Connector · brokenAFT FLOOR EMER LIGHT HAS A BROKEN OFF CONNECTOR. REPLACED CONNECTOR IAW SWPM 20-50-01.SDR CALA2015022000110Connector · damagedEAT 15 ABC EMER LIGHT INOPERATIVE. R & R DAMAGED CONNECTOR AT SEAT ROW 15 ABC OTBD LEG. PN 172343-1 CONNECTOR. OPERATIONS CHECKED OF EMERG LIGHTING GOOD IAW AMM 33-51-00.SDR SWIA2015021340722Wire · brokenFWD TWO RED EMERGENCY LIGHTS INOPERATIVE. REPAIRED THE WIRE FOR THE EMERGENCY LIGHTS AND RELAMPED. OPS CHECKED GOOD.SDR DALA2015021701278Wire · brokenSEAT 43 DEF SEAT MOUNTED EMERGENCY LIGHT IS INOPERATIVE. REPAIRED BROKEN WIRE IAW SWPM 20-64-17, CHECKED GOOD.SDR USAA2015021300003Connector · disconnectedEMERGENCY LIGHT SEAT 14C INOPERATIVE. FOUND CONNECTOR DISCONNECTED & RECONNECTED IT. OK FOR SERVICE.SDR CALA2015021293126Connector · unsecureSEAT 19H EEL INOPERATIVE. SECURED EEL CONNECTOR. OPERATIONS CHECKED OK.SDR DALA2015021201207Wire Harness · damagedMAINTENANCE FOUND EMERGENCY LIGHT INOPERATIVE AT 22D. MAINTENANCE REPLACED THE SEAT WIRE HARNESS IAW AMM 33-53. OPS CHECKED GOOD.SDR ASAA2015021010617Ground Stud · corrodedFOUND EMERGENCY AISLE, BULLNOSE, SPOTLIGHT INOPERATIVE AT ROW 22L, ACFT GROUNDED. FOUND GROUND BLOCK AT 727C+13 CORRODED. R & R GROUND BLOCK AT STA 727C, IAW SRM 51-40-02. R & R LIGHT HOUSING ASSY AND REPLACED THE LAMP. OPS GOOD IAW AMM 33-51-03.SDR DALA2015021101169Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THE SEAT 12DE EMERGENCY LIGHT HARNESS DAMAGED. MAINTENANCE REPLACED THE HARNESS AND THE OPS CHECK WAS SATISFACTORY.SDR ASOA2015021112202Connector · disconnectedLEFT OVERWING EMERGENCY LIGHTS ARE INOPERATIVE. FOUND CONNECTOR TO BE DISCONNECTED. RECONNECTED IAW WM25-28-01. OPS TESTED GOOD IAW 33-51-000-710-801.SDR USAA2015021100006Connector · brokenEMERGENCY LIGHT AT ROW 27 INOPERATIVE. FOUND A BROKEN CONNECTOR. REPLACED EMER LIGHT CABLE ASSEMBLY F1001430-48 IAW IPC 33-51-09-24N. OPERATIONAL CHECKED GOOD.SDR DALA2015021101158Wire · brokenROW 25 EMERGENCY LIGHT INOPERATIVE. SPLICED BROKEN WIRE IAW SWPM, CHAP 20. OK FOR SERVICE.
Back to JASC 3397