As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND EMERGENCY AISLE, BULLNOSE, SPOTLIGHT INOPERATIVE AT ROW 22L, ACFT GROUNDED. FOUND GROUND BLOCK AT 727C+13 CORRODED. R & R GROUND BLOCK AT STA 727C, IAW SRM 51-40-02. R & R LIGHT HOUSING ASSY AND REPLACED THE LAMP. OPS GOOD IAW AMM 33-51-03.