JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2014080104289Connector · unsecureONE EMERGENCY LIGHT BULB, INOPERATIVE AT 3C AND ONE EMERGENCY LIGHT BULB, INOPERATIVE AT 10C. REPLACED BULBS AND SECURED CONNECTOR AT 10C. BOTH OPS NORMAL.SDR DALA2014080104288Connector · unsecureFLOOR PROXIMITY EMERGENCY ESCAPE PATH MARKING AT SEATS 3B AND 10C INOPERATIVE. REPLACED THE LAMPS 3C AND SECURED THE CONNECTOR AT 10C. BOTH OPS NORMAL.SDR AALA20140730003Wire · brokenAFT STAIRWELL OVERHEAD LIGHT PANEL HAS BROKEN WIRE. REPAIRED WIRE FOR OVERHEAD EMER LIGHT. OPERATIONS CHECKED NORMAL.SDR USAA2014072800015Connector · not seatedWHILE PERFORMING JOB CARD 26L00025011 DOOR ESCAPE SLIDE & RAFT REPLACEMENT, STEP 6 OPERATIONS TEST OF ESCAPE FACILITIES FAILED. FAULT IN CIDS IS EPSU EXT LOAD AFT LT IAW TSM 33-51-00-810-808-A STEP 4 E 2. FOUND CONNECTOR UNDER VELCRO NOT SEATED, AFTER SLIDE SDR SIMA20140726015Splice · damagedEMERGENCY LIGHTING, EXIT LOCATOR, FWD INDICATOR ON CEILING PANEL INOPERATIVE. REPAIRED SPLICES SP 9208 & SP 9209 ON EMER LIGHTING IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20140726023Wire · brokenLIGHT STRIP NR 5 HAS BROKEN WIRE AT STRIP. REPLACED NR 5 EMER LIGHT STRIP IAW AMM 33-50-08. SEE BOW 161234 FOR FINAL INSTALL & OPERATIONAL CHECK.SDR SIMA20140726016Wire · damagedEMERGENCY LIGHTING, EXIT MARKER, AFT OF RT OVERWING EXIT INOPERATIVE. REPAIRED WIRE ON EMER LIGHTING IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.SDR CALA2014072891558Wire · unsecureEMERGENCY CEILING LIGHT ON THE LT SIDE IN BUSINESS CLASS INOPERATIVE. SECURED & INSTALLED LOOSE WIRE FOR EMER LIGHT.SDR ASAA2014072508692Ground Stud · corrodedDURING AN EMERGENCY LIGHT CHECK, AFT OVERHEAD EMERGENCY LIGHT SIGN BETWEEN LAVS WOULD NOT TURN OFF. ACFT GROUNDED. VERIFIED ALSO FOUND TOTAL OF SIX EMERGENCY LIGHT INOPERATIVE IAW WDM 33-51-14, PG1, M1672 EMERGENCY EXIT LIGHT BATTERY PACK GROUND BLOCK GD3998SDR SIMA20140725006Wire · disconnectedNUMBER 5 EMER LIGHT FLOOR STRIP BY OVERWING EXITS INOPERATIVE. SOLDERED WIRE TO CONNECTOR TO EMER LIGHT FLOOR STRIP IAW SWPM 20-30-00. OPERATIONS CHECKED GOOD IAW WC 33-700-17.SDR HNAA2014072500215Connector · damagedEMERGENCY LIGHT IS INOPERATIVE AT ROW 6. R & R 1 PIN IN CONNECTOR IAW MM 20-45-09. OPS CHECKED GOOD.SDR SIMA20140724003Wire · brokenBROKEN WIRE ON FLOOR PROXIMITY STRIP EMER LIGHTS ROW 14. R & R FLOOR PROXIMITY STRIP EMER LIGHTS ROW 14 IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.SDR CA140728018Wire · shorted(CAN) THE RH ESSENTIAL BUS BEGAN SMOKING AND SHORTED AFTER TAKE OFF.AIRCRAFT RETURNED TO BASE. THE WIRES OFF OF ONE OF THE WHEAT LIGHT LAMPS WERE SHORTING ON EACH OTHER. MAYBE THE COPILOT LEANED ON THE PANEL AND CAUSED THEM TO COME INTO CONTACT. THIS CAUSED SDR REXA2014072300727Ground Wire · out of positionRIGHT WING FWD OVERWING EMERGERNY EXIT LIGHT IS INOPERATIVE. REPOSITIONED GROUNDING WIRE GS846, 6 VOLTS TO LIGHT. OPS CHECKED GOOD IAW AMM 33-51-00.SDR SWIA201438884Connector · damagedFLOOR EMERGENCY LIGHT ON THE WARDROBE INOPERATIVE. R & R CONNECTOR AND PIN IAW ESPM.SDR DALA2014072304202Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THAT THE SEAT MOUNTED EMERGENCY EXIT LIGHT AT THE OVERWING EXIT ROW WAS INOPERATIVE. MAINTENANCE FOUND A CONNECTOR IN THE WIRE HARNESS UNPLUGGED, RECONNECTED IT, AND FUNCTIONALLY CHECKED THE SYSTEM.SDR CALA2014072300990Connector · disconnectedEMERGENCY FLOOR PROXIMITY LIGHT IS INOPERATIVE AT SEAT ROW 30ABC. TROUBLESHOOT & FOUND EMER FLOOR PROXIMITY LIGHT PLUG DISCONNECTED AT SEAT ROW 30ABC. RECONNECTED PLUG & OPERATIONS CHECKED GOOD IAW NG AMM 33-51-11.SDR DALA2014072204174Wire · brokenDURING EMERGENCY LIGHT CHECK . FOUND SEAT LIGHT INOPERATIVE IN SEAT 19 THRU 26 FOUND BROKEN WIRE IN SEAT 26 F. REPAIRED WIRE IAW SWPM 20-30. OPS CHECKED GOOD.SDR DALA2014072204173Connector · unsecureSEATS 11 EMERGENCY LIGHT INOPERATIVE. SECURED CONNECTOR UNDER SEAT 11 IAW AMM 33-51-19. OPS CHECKED OK.SDR DXTA2014072205827Connector · burnedDURING DESCENT, SMOKE EMITTED FROM THE GALLEY AREA. HEARD AN ELECTRICAL SIZZLING & SAW SMOKE COMING OUT OF THE GALLEY AREA ABOVE THE LIQUOR CABINET & ABOVE THE ADJACENT INDIRECT OVERHEAD LIGHT PANEL. TURNED OFF THE INTERIOR MASTER SWITCH & THE SMOKE STOPPSDR SIMA20140721008Connector · looseSERVICE DOOR EMER EXIT SIGN INOPERATIVE. TROUBLE SHOT EMER LIGHT IAW FIM 33-50-00-810-804-A. FOUND CONNECTOR LOOSE, ATTACHED CONNECTOR IAW AMM 33-50-09-400-802-A. OPERATIONS CHECKED GOOD.SDR SIMA20140721007Connector · looseSERVICE DOOR OVERHEAD EMER LIGHT INOPERATIVE. TROUBLE SHOT EMER LIGHT IAW FIM 33-50-00-810-804-A. FOUND CONNECTOR LOOSE, ATTACHED CONNECTOR IAW AMM 33-50-09-400-802-A. OPERATIONS CHECKED GOOD.SDR USAA2014072200002Connector · not seatedTHE OVERHEAD EMER EXIT LIGHTS AT OVERWING STATION ARE NOT ILLUMINATED. RESEATED CONNECTIONS IN CEILING AT OVERWING. RESET EPSU'S. OPERATIONS GOOD, OK FOR SERVICE.SDR ASAA2014072008617Connector · wornDURING AN EMERGENCY LIGHTS OPS CHECK. FOUND ROW 12ABC AREA LIGHT INOPERATIVE. ACFT GROUNDED. REPLACED THE LAMP, NO HELP. CHANGED AREA LIGHT ASSY IAW MM 33-51-03-960-802 STILL INOPERATIVE. FOUND SEAT 12ABC AISLE LIGHT DISCONNECTS D13470 AND D11344 LOCATED SDR CALA2014072291506Connector · brokenSEAT 24AB CEILING EMER LIGHT CONNECTOR BROKEN. REPLACED EMER LIGHT CONNECTOR IN CEILING ABOVE SEAT 24AB. OPERATIONS CHECKED GOOD.SDR SIMA20140720006Wire · brokenCEILING EXIT SIGN NEAR GALLEY IS INOPERATIVE. FOUND WIRE BROKEN ABOVE RT GALLEY BETWEEN CONNECTOR P8525 NAD SP9008. REPAIRED WIRE IAW SWPM 20-21-00 & WM 33-50-50. OPERATION CHECKED GOOD IAW AMM 33-50-00.SDR SWIA201438834Wire · brokenGALLEY EMERGENCY EXIT SIGN HAS TWO BROKEN WIRES. REPAIRED WIRES IAW ESPM.SDR SWIA201438833Wire · brokenFLOOR EXIT SIGN HAS A BROKEN WIRE. REPAIRED THE WIRES IAW ESPM.SDR CALA2014072291510Wire · damagedESCAPE PATH LIGHT INOPERATIVE AT ROW 45ABC. REPAIRED WIRING, LIGHTS CHECKED NORMAL.SDR DALA2014072104170Wire · detachedAFT STAIRWELL FIRST HORIZONTAL EMERGENCY EXIT PATHWAY LIGHT ASSEMBLY INOPERATIVE. CONNECTED WIRES TO LIGHT ASSY AT QUICK DISCONNECT. OPS CHECKED GOOD.SDR SIMA20140718004Wire · brokenFIRST EMER LIGHT STRIP WIRE BROKEN. REPLACED ELEC CONNECTOR, MALE, ON THE POWER SUPPLY HARNESS ACFT SIDE TO THE FLOOR PROXIMITY STRIP LIGHT NR 1 IN THE MAIN CABIN IAW SWPM 20-21-00, 20-50-00 & 20-50-01 & IAW AMM 33-50-12 & 33-50-00, OPERATIONS CHECKED GOOD.SDR SIMA20140718003Wire · brokenNUMBER 1 EMER LIGHT STRIP HAS BROKEN WIRES. INSTALLED CONNECTOR AT NR 1 LIGHT STRIP IAW WM 91-10-02 & SWPM 20-00-03, FOR OPERATIONS CHECK SEE BOW 160456.SDR SWAA2014072130121Connector · disconnectedLEFT OVERWING DOOR LOWER EXIT SIGN INOPERATIVE. RE-CONNECTED CONNECTOR IAW AMM.SDR DALA2014071804160Wire Harness · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTING AT SEAT 27D WAS INOPERATIVE. MAINTENANCE REPLACED THE WIRE HARNESS AND THE SYS RETURNED TO NORMAL OPERATION.SDR AALA20140721010Wire Harness · damagedLIGHTNING STRIKE TO LT WING TIP. REPLACED WIRE HARNESS IN LT WING TIP. OPERATIONS CHECKED NORMAL.SDR PNSA2014071705Pin · damagedLEFT AFT EXTERIOR EMER LIGHT 3LN WILL NOT LIGHT DURING ELPS TESTING. REPAIRED PIN 1 ON AFT EXTERIOR EMER LIGHT 3LN.SDR USAA2014071800007Terminal · defectiveEMERGENCY LIGHT OVER R3 DOOR DOES NOT LIGHT. REPLACED R3 EMER EXIT LIGHT TERMINAL END.SDR DALA2014071704133Wire · damagedDURING EMERGENCY LIGHTS CHECK, FOUND ROW 38 THRU ROW 45 FLOOR LIGHTS INOPERATIVE. FOUND FAULTY SPLICE BETWEEN SEAT ROW 38 DEF AND ROW 40 DEF, REPAIRED SPLICE IAW SWPM. EMERGENCY LIGHTS CHECKED GOOD, OK FOR SERVICE.SDR CALA2014072191484Wire · out of positionSEAT 1A EMER LIGHT STAYS ON AT ALL TIMES. FOUND WIRING IN SEAT 2A FOOT REST SWAPPED. RE-CONNECTED 1A EEL LIGHT CORRECTLY. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.SDR CALA2014072191483Connector · not seatedSEAT 10K EMER LIGHT INOPERATIVE. RESEATED CONNECTOR IAW AMM 33-51-10. OPERATIONS CHECKED GOOD.SDR AALA20140717004Connector · looseSEAT MOUNTED EMER LIGHT AT SEAT 3D INOPERATIVE. SECURED LOOSE WIRE CONNECTORS FOUND ON SEAT MOUNTED EMER LIGHT ASSEMBLY AT SEAT 3D. OPERATIONS CHECKED NORMAL.SDR SIMA20140716004Connector · dirtySERVICE DOOR OVERHEAD EMER EXIT SIGN INOPERATIVE. DISCONNECTED, CLEANED & REINSTALLED SERVICE DOOR OVERHEAD EMER EXIT SIGN IAW AMM 33-50-14. OPERATIONS CHECKED GOOD.SDR DALA2014071604130Wire · brokenEMERGENCY LIGHT AT ROW 1 RT INOPERATIVE. REPAIRED BROKEN WIRE IAW SWPM CH 20-30.SDR DALA2014071504106Wire · brokenWHITE EMERGENCY LIGHT INOPERATIVE AT SEAT 27D. FOUND BROKEN WIRE UNDER THE SEAT. REPAIRED WIRE IAW SWPM 20-30.SDR ASOA2014071810911Connector · disconnectedLT AFT UPPER & LOWER AND RT FWD UPPER & LOWER EMERGENCY LIGHTS AT OVERWING EXITS ARE INOPERATIVE. CONNECTED CONNECTORS FOR EMERGENCY EXIT LIGHTS IAW ESPM 20-26-04. PERFORMED OPS TEST OF THE EMERGENCY EXIT LIGHTS IAW ANN 33-51-00-710-802.SDR REXA2014071400699Connector · unsecureCABIN EMER FLOOR LIGHTS BACK OF ACFT INOPERATIVE. SECURED CONNECTION AT AFT SIDE OF FLOOR OF EMER FLOOR LIGHTING. OPERATIONS CHECKED GOOD IAW 33-51-00.SDR SWAA2014071530010Wire · looseRIGHT EEPLS WIRE LOOSE BETWEEN ROW 25 TO ROW 31. SECURED WIRE IAW MM.SDR SWAA2014091532066Ground Wire · damagedFORWARD LAVATORY EMER EXIT INDICATOR LIGHT GND WIRE INOPERATIVE. REPAIRED WIRE IAW WDM & MM.SDR SIMA20140713005Splice · damagedDURING PS 1 INSPECTION FOUND SECTION 4 FLOOR PROXIMITY EMER LIGHT ASSEMBLY INOPERATIVE. ITEM DEFERRED IAW MEL 33-30. INSTALLED NEW SPLICES AT SECTION 4 FLOOR STRIP IAW WM CH 20-50-01. OPERATIONS CHECKED GOOD IAW MM CH 33-50-00. MEL ITEM RESTORED.SDR DALA2014071404107Connector · disconnectedDURING CHECK, MAINTENANCE FOUND THE EMERGENCY PATH IN SEAT LIGHTS WERE INOPERATIVE AT ROWS 11 AND 16. MAINTENANCE FOUND THE CONNECTORS DISCONNECTED AND THEY RECONNECTED THEM. LIGHTS RETURNED TO AN OPS STATE.
Back to JASC 3397