JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20140713004Wire · brokenNUMBER 6 EMER LIGHT STRIP HAS BROKEN WIRE. R & R NR 6 PROXIMITY LIGHT IAW AMM 33-50-12.SDR DALA2014071404087Switch · miswiredWHEN EMERGENCY LIGHT SWITCH COVER IS CLOSED IT DISARMS EMERGENCY LIGHTS. REPOSITIONED WIRE TO CORRECT SIDE OF SWITCH. CHECKED OK.SDR SWIA201438835Wire · looseEXIT SIGN ON LOWER CORNER OF WARDROBE HAS A LOOSE WIRE. REPAIRED WIRE IAW ESPM AND AMM.SDR REXA2014071100692Connector · disconnectedEXIT LIGHTS IN CABIN FROM OVERWING EXIT AFT DO NOT LIGHT UP. RECONNECT AFT CONNECTOR & OPERATIONS CHECKED GOOD IAW 33-51-01.SDR F3LA2014071501048Wire · looseEMERGENCY LIGHTS SEAT ROW 10, 11 & 12 INOPERATIVE. TERMINATED WIRING AT TERMINAL BLOCK 7225VT NR 12. OPERATIONAL CHECK OF EMER LIGHTS NORMAL IAW AMM 33-51-00-710-001.SDR SWAA2014072130143Wire · brokenFORWARD LAVATORY EMER LIGHT ASSEMBLY WIRE BROKEN. R & R WIRE IAW SWPM.SDR CALA2014071400917Connector · not seatedSUPPORT TASK AISLE LIGHTING FROM ROW 22ABC TO 25ABC INOPERATIVE, TROUBLESHOOTING. REMOVED LOWER SIDEWALL PNL AT ROW 27ABC FOR ACCESS TO CONNECTOR D14710, FOUND IT WAS NOT SEATED PROPERLY. RESEATED CONNECTOR D14710 IAW SWPM 20-60-06 AISLE LIGHTS. CHECKED GOOSDR ASOA2014071110870Wire · pulledEMERGENCY LIGHT NR 1 BATTERY HAS TWO WIRES PULLED OUT OF CONNECTOR P535P1 INSTALLED NEW SPLICE AT IAW ESPM 20-44-00. OPS CHECK GOOD IAW AMM 33-51-00-710-801.SDR KCSA2014070906Ground Stud · damagedCOCKPIT UPPER AFT FACING DOME LIGHT INOPERATIVE. REPLACE GROUND TERMINAL ON COCKPIT UPPER AFT FACING DOME LIGHT IAW SWPM 20-30-11. LIGHT OPERATIONS CHECK GOOD.SDR SWIA201438661Connector · damagedEMERGENCY EXIT SIGN ON WARDROBE INOPERATIVE. C-CHECK, R & R CONNECTORS ON EMERGENCY EXIT SIGN IAW ESPM.SDR SWIA201438625Wire · brokenFLOOR EMERGENCY LIGHTING INOPERATIVE AT ROW 3. REPAIRED BROKEN WIRE AND PERFORMED OPS CHECK, NO OTHER DEFECTS NOTED.SDR SWIA201438624Ground Wire · damagedFLOOR EMERGENCY LIGHTS INOPERATIVE. REPLACED SPLICE ON THE GROUND WIRE. OPS GOOD.SDR DALA2014071004039Wire · brokenSEAT ROW 41ABC HAS EMERGENCY LIGHT WIRE BROKEN. REPAIRED BROKEN EMERGENCY LIGHT WIRE AT SEAT 41ABC.SDR FDEA201407091671Pin · backed outDURING PREFLIGHT, FOUND L1 DOOR EMER SLIDE LIGHT INOPERATIVE. REMOVED LIGHT ASSEMBLY & CHECKED VOLTAGE TO LIGHT WITH EMER LIGHTS ON, THERE IS NO POWER TO L1 SLIDE LIGHT. DURING TROUBLESHOOTING FOUND PIN 9 OF PLUG D68 PUSHED BACK INTO PLUG BATTERY CHARGER CONSDR SIMA20140708004Connector · unsecureBOTH SIDES AFT OVERWING EXTERIOR EMER LIGHTS INOPERATIVE. SECURED WIRE CONNECTION LT OVERWING EXTERIOR EMER LIGHT IAW SWPM 20-21-00. OPERATIONS CHECKED GOOD.SDR DALA2014070803950Wire · brokenFOUND EMERGENCY LIGHT AT GALLEY 404 DAMAGED AND WIRE BROKEN. SECURED WIRE IAW WDM 20.SDR AALA20140707018Wire Harness · damagedWHITE EMER PATH LIGHT AT SEAT 9C INOPERATIVE. UNDER SEAT CABLE DAMAGED. REPLACED HARNESS FOR EMER PATH LIGHT AT SEAT 9C. OPERATIONS CHECKED NORMAL.SDR AALA20140707013Connector · looseROW 16 & 17 SIDE SEAT EMER EGRESS LIGHTS INOPERATIVE. FOUND SEAT TO WALL CONNECTOR KNOCKED LOOSE. RECONNECTED CONNECTOR. OPERATIONS CHECKED NORMAL.SDR MASA2014070702216Connector · disconnectedSERVICE DOOR OVERHEAD EXIT SIGN INOPERATIVE. RECONNECTED CONNECTOR J336 IN CEILING PANEL.SDR MASA2014070702215Connector · disconnectedPAX DOOR OVERHEAD EXIT SIGN INOPERATIVE. RECONNECTED CONNECTOR J336 IN CEILING PANEL.SDR CALA2014071191411Wire · chafedFOUND SEVEN WIRES CHAFED & SHORTING TO CARBON FIBER PANEL AT APO315, POS 6 D6113J, WIRES W9971-0035, 0036, 0044, 0045, 0058, 0059 & 0060. REPLACED WIRES W9971-0058 -20, -0059-20, -0060-20 IN D9602P IAW DWG A603301-005 PG 47. ROUTED & SECURED WIRES. TERMINATSDR SWIA201438648Wire · brokenBROKEN WIRE ON FORWARD EMERGENCY LIGHTS BATTERY CHARGER CONNECTOR PS35. C-CHECK INSTALLED NEW SPLICE CR124 IAW WDM AND ESPM.SDR YENA20140705125Wire Harness · damagedDURING A MAINTENANCE CHECK, FOUND ROW 15ABC EMERGENCY LIGHT INOPERATIVE. REPLACED WIRE HARNESS IAW CMM 25-25-15. CHECKED NORMAL.SDR AALA20140706002Connector · disconnectedEMERGENCY PATH LIGHTS FROM ROWS 33 TO 45 INOPERATIVE. FOUND PLUG AT SEAT 33B DISCONNECTED. SECURED PLUG. OPERATIONS CHECKED NORMAL.SDR USAA2014070700001Connector · disconnectedCREW REPORTED THE EMER LIGHT ON ROW 16L INOPERATIVE. FOUND SEAT CONNECTOR DISCONNECTED. RECONNECTED CONNECTOR & OPERATIONS CHECKED GOOD IAW AMM 33-51-00-710-009-A.SDR DALA2014070703901Wire · pulledDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHTS AT SEATS 08C-23C INOPERATIVE. MAINTENANCE FOUND WIRE PULLED FROM SPLICE AT EACH LOCATION. SPLICED WIRES BACK TOGETHER AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA2014070303945Wire Harness · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE SEAT MOUNTED EMERGENCY LIGHT WAS INOPERATIVE AT SEAT 31D. MAINTENANCE REMOVED AND REPLACED THE WIRE HARNESS AND OPS CHECKED GOOD.SDR JJBA20140703013Wire · looseCABIN EMER LIGHTS CAME ON IN FLIGHT. REPAIRED LOOSE WIRE ON FLIGHT ATTENDANT PANEL SWITCH.SDR CALA2014070291401Pin · backed outIAW A CHECK SEAT EEL AT 19H INOPERATIVE. FOUND PIN PUSHED IN AT CONNECTOR OF EEL LIGHT.SDR SIMA20140702001Connector · unsecureFORWARD BULKHEAD AT 3BC EMER EXIT SIGN INOPERATIVE. PERFORMED TROUBLESHOOTING IAW WMM 33-50-50. SECURED CONNECTOR P8530 IN FWD GALLEY CEILING PANEL. OPERATIONS CHECKED GOOD IAW 145 AMM 33-50-00.SDR SIMA20140701017Connector · brokenNUMBER 8 EMER LIGHT STRIP WIRING CONNECTORS ON PLANE SIDE BROKEN OFF. INSTALLED NR 8 EMER LIGHT CONNECTORS ON PLANE SIDE IAW SWPM 20-21-00. SEE BOW 159911 FOR OPERATIONS CHECK.SDR SIMA20140701012Wire · brokenEMERGENCY LIGHT STRIP 3 HAS BROKEN WIRES. R & R FLOOR EMER LIGHT STRIP 3 IAW AMM 33-50-12. SEE NRWC BOW 158177 FOR FLOOR EMER LIGHTS OPERATIONAL CHECK. FOUND DURING OPEN UP.SDR SIMA20140701013Wire · brokenEMERGENCY LIGHT LENS NR 2 HAS BROKEN WIRES. R & R FLOOR EMER LIGHT STRIP NR 2 IAW AMM 33-50-12. SEE NRTC BOW 158177 FOR OPERATIONAL CHECK OF EMER FLOOR LIGHTS FOUND DURING OPEN UP.SDR USAA2014070700004Wire · disconnectedSEAT 22C WHITE SEAT MOUNTED LIGHT INOPERATIVE. RECONNECTED WIRE TO SEAT 22F EMER SEAT LIGHT IAW WDM 33-51-11. LIGHT OPERATIONS CHECKED GOOD.SDR DALA2014070203845Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY LIGHTS AT ROW 6DEF WAS INOPERATIVE. MAINTENANCE FOUND WIRES BROKEN AT THE LIGHT RECEPTACLE. REPLACED THE LIGHT ASSEMBLY AND THE SYSTEM RETURNED TO NORMAL.SDR CA140716005Resistor · burned(CAN) EARLY IN THE INVESTIGATION OF THIS INCIDENT, IT WAS DECIDED THAT THIS DID NOT MEET THE REQUIREMENTS NECESSARY TO SUBMIT AN SDR, HOWEVER WE HAVE CHOSEN TO SUBMIT IT. THREE MINUTES AFTER REACHING CRUSE ALTITUDE (14000 FT), AN ELECTRICAL FIRE ODOR WAS NOTICSDR SWAA2014090931759Connector · damagedFORWARD RT SERVICE DOOR EXIT LIGHT PLUG CONNECTOR DAMAGED. R & R CONNECTOR IAW WDM & AMM.SDR HNAA2014063000192Wire · brokenCENTER AISLE OVERHEAD EMERGENCY EXIT SIGN IS INOPERATIVE. REPAIRED BROKEN WIRE AT LIGHT ASSY. OPS CHECKED GOOD.SDR DALA2014070103963Wire · damagedDURING HEAVY CHECK, MAINTENANCE FOUND THAT THE EMERGENCY ESCAPE PATH LIGHTS WERE INOPERATIVE AT G2. THE WIRING WAS REPAIRED AND THE LIGHTS RETURNED TO AN OPERATIONAL STATE.SDR SWIA201438456Feeder Cable · damagedEMERGENCY LIGHTS INOPERATIVE. REPLACED THE RIBBON GOING TO THE EMERGENCY LIGHTS. OPS CHECKS GOOD.SDR ASOA20140629076RConnector · damagedCREW REPORTED THE EMERGENCY EXIT SIGN OVER EXIT ROW INOPERATIVE. MX SECURED CONNECTOR CONTACT PINS WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SWIA201438505Wire · brokenROW 9 EMERGENCY LIGHT IN OVERHEAD BIN DOESN'T WORK, OR FLASHES INTERMITTENTLY. REPAIRED BROKEN WIRE. OPS CHECKED GOOD IAW AMM.SDR DALA2014063003838Ground Stud · damagedEMERGENCY EXIT SIGN AT L4 DOOR WILL NOT ILLUMINATE DURING TEST. REPLACED GROUND STUD GD489-DC IAW WDM 33-51-15 AND SWPM CHAPTER 20-20.SDR CALA2014063091380Connector · missingSEAT 21DEF EMER LIGHT Y CONNECTOR MISSING. REPAIRED SEAT 21DEF EMER LIGHT Y CONNECTOR BY REPINNING IAW BSWPM 20-64-17. EMER LIGHTS OPERATIONS CHECKED GOOD.SDR SIMA20140628017Wire · brokenONE PROX LIGHT WITH ARROWS & ONE PROX LIGHT WITHOUT ARROWS HAVE BROKEN WIRES AT PROX LIGHT. R & R IAW AMM 33-50-12. SEE NRTC BOW 159263 FOR FINAL INSTALL & OPERATIONS CHECK.SDR SIMA20140628009Wire · brokenFORWARD PROXIMITY LIGHT STRIP WIRE BROKEN AT SPLICE CONNECTOR. REPAIRED FWD PROXIMITY LIGHT STRIP WIRE AT SPLICE CONNECTOR IAW SWPM 20-21-00 STEP 6.SDR DALA2014070603875Wire · disconnectedEMERGENCY ESCAPE LIGHT INOPERATIVE AT ROW 11. CONNECTED PIN AT LIGHT ASSY. OPS CHECKED GOOD, OK FOR SERVICE.SDR SWIA201438458Connector · unsecureEMERGENCY EXIT SIGN SEAT 8D INOPERATIVE. SECURED LOOSE CONNECTOR BETWEEN ROW 7 AND 8.SDR SIMA20140628003Wire · brokenNUMBER 2 EMER PROXIMITY LIGHT STRIP HAS BROKEN & DAMAGED WIRES. R & R FWD GALLEY EMER LIGHT STRIP IAW AMM 33-50-12.SDR CALA2014063091376Cable · damagedEEL STRIP & LEAD IN CABLE DAMAGED AT LAVATORY K. REPAIRED EEL CABLE LEAD & OPERATIONS CHECKED IAW AMMM 33-51-96 & AMMM 33-51-00.
Back to JASC 3397